FEATURES
Alkaline battery supply 9V 6LR61/MN1604/1604A (included) Consumption <10 µA (monitor) about 50 mA (during alarm) Battery autonomy about 3 years with alkaline battery (extreme environmental conditions
can significantly reduce the battery autonomy)
Operating temperature -10° ÷ +60° Indoor installation, on wall Acoustic alarm with buzzer 105dB @10cm (3400Hz) Light indication with red LED lights, 600 mcd Sizes (H x ø) 40 x 150 mm Weight about 135g without battery Material and color ABS white (cover) | ABS grey (bottom) | PMMA transparent (button)
SPECIFICATIONS
Acoustic alarm mode: intermittent sound, duration 2 minutes or manual interruption Light indication mode: intermittent flash, duration 5 minutes or manual interruption Functional Test: hit several times the plastic cover with the knuckles until a false alarm is
generated
Status indicator every 30 secondss Check low battery every 6 hours (verify), every 30 minutes (state) 'Tilt' signaling every 5 minutes Duration of the inactivity state about 15 seconds