Guardian RAC4825, RAC5110CS, RAC5000 Use & Care Instructions Manual

Page 1
USE & CARE INSTRUCTIONS
Guardian Technologies LLC
26251 Bluestone Blvd. | Euclid, Ohio 44132
1.866.603.5900 | www.guardiantechnologies.com
©20015 Guardian Technologies LLC
Refurbished
Air Cleaning System
30 -Day Limited Warranty
www.guardiantechnologies.com • 1.866.603.5900
REV1115
Replacement Filter/RAC4825 22" Model: Filter (FLT4825) Replacement Filter/RAC5000/RAC5110CS 28" Model: (FLT5000)
To order Contact Customer Service
1.866.603.5900 or log on to www.guardiantechnologies.com
B
C
E-1
Page 2
Page 3
Control Panel
PRODUCT PARTS
Carrying Handle
AIR CLEANING SYSTEM
Improve your indoor air quality with your new Germ Guardian® Air Cleaning System. Multiple levels of cleaning include a combination filter that captures allergens, and Charcoal filter to remove odors. UV-C light technology enhances germ-killing.
PRE-FILTER*
Captures initial dust and allergen particles.
Air Outlet
Base
Air Inlet
Unit Body
FRONT OF UNIT BACK OF UNIT
CONTROL PANEL
-C Bulb Button/
UV
Power Knob
Filter/UV Bulb
Reset
Lock & Release Button
(for accessing Filter and Bulb)
Filter Access Cover
CHARCOAL FILTER*
Contributes to the control and prevention of the growth of bacteria, germs and mold.
FILTER
Reduces allergens.
UV-C LIGHT
UV-C light technology works with filters to enhance the elimination of airborne germs Titanium Dioxide is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.
*Pre-Filter and Charcoal Filter are combined into one layer that attaches to the Filter.
AIR CLEANING LAYERS
AC4825 SERIES
Lock & Release Button
UV-C Bulb
UV-C Metal Shield
Power Indicator/ Change Filter Indicator
Main Unit
Combination Filter B
includes Pre/ Charcoal & filter
Rear Cover
with Air Inlet Grill
E-5E-4
Page 4
AIR CLEANING LAYERS
INSTALLING & REMOVING COMBINATION FILTER
AC5000 SERIES
Main Unit
OPERATING INSTRUCTIONS
UV-C Bulb
UV-C Metal Shield
Combination Filter C
includes Pre/
harcoal &
C
filter
Lock & Release Button
Rear Cover
with Air Inlet Grill
CHANGE FILTER INDICATOR
The green power light on the air cleaner will turn red and flash continuously indicating that it is time to replace the filter. Replace the filter according to the directions then press the UV control button and hold for 5 seconds to restart the system. The light will turn back to green. Depending on usage, filter will last approximately 6 months.
REPLACE FILTER
1. Turn off and unplug the unit.
2. Press the Lock & Release Button and remove the Rear Cover from the unit.
3. Remove the used Combination Filter.
4. Insert new Combination Filter into the unit. Consult the arrow on the filter for correct installation direction.
BEFORE OPERATING THE AIR PURIFIER:
1. Carefully remove your air purifier from box and bag.
2. Select a firm, level and flat location for the air purifier. * For proper air flow, locate the unit at least 1 foot from any wall or furniture. * Make sure none of the grills are blocked.
3. Plug the power cord into a 120V AC outlet.
IMPORTANT: When moving the air purifier, always lift unit by the carrying handle located on back.
5. Reattach the Rear Cover of the unit and securely latch into place.
6. Push and hold UV Control Button for 5 seconds to reset Filter Change Indicator.
OPERATING THE AIR PURIFIER:
1. Turn the air purifier ON by rotating POWER KNOB clockwise.
2. Upon turning the air purifier ON, the power indicator will be lit (green) and the unit will
be in LOW mode ( ).
3. Rotate the POWER KNOB clockwise to set the air purifier to MEDIUM ( ) or
High mode ( ).
4. To activate the UV-C Bulb, press the UV button. Press the button again to turn OFF the
UV-C Bulb.
5. To turn the unit OFF, rotate the POWER KNOB counter-clockwise to OFF mode (•).
E-6 E-7
Check out our on-line Filter Reminder and Replacement program.
www.guardiantechnologies.com
Page 5
CLEANING & MAINTAINING
AC4825 SERIES
THE COMBINATION FILTER
The air purifier should be cleaned at least once every month and the outer Pre-/Charcoal Filter attached to the Filter should be cleaned every month. More frequent cleaning may be required depending on environmental conditions.
PRE-/CHARCOAL FILTER
Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt.
Filter Package includes:
1
-Piece Filter
1-Piece Pre-/Charcoal Filter
Filter lasts approximately 6-8 months depending on use
F
ILTER
Remove the Combination Filter from the back of unit. Remove the Pre-/Charcoal Filter to expose the filter. When the Filter turns from white to grey or black it should be replaced with a new one. If the filter is still white, it does NOT need to be replaced.
Create ONE COMPLETE COMBINATION FILTER
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
This air cleaner is suggested for use in a single, closed room up to 155 square feet.
Higher CADR rates provide improved performance in all room sizes. Portable air cleaners will be much more effective in rooms when all the doors and windows are closed.
TOBACCO SMOKE: 100+ AC4825
This value represents performance that can be expected within the first 72 hours of operation. Subsequent use may vary with use.
Tested per ANSI/AHAM AC-1 National Standard
AC5000 SERIES
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
This air cleaner is suggested for use in a single, closed room up to 193 square feet.
Higher CADR rates provide improved performance in all room sizes. Portable air cleaners will be much more effective in rooms when all the doors and windows are closed.
TOBACCO SMOKE: 125+ AC5000
This value represents performance that can be expected within the first 72 hours of operation. Subsequent use may vary with use.
Tested per ANSI/AHAM AC-1 National Standard
IMPORTANT: Do NOT try to wash and re-use the Combination Filter. Please contact Customer
Service at 1.866.603.5900 or visit us at www.guardiantechnologies.com to purchase a replacement filter.
What is CADR?
CADR stands for “Clean Air Delivery Rate,” which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particules from things like tobacco smoke and plant pollens from the room.
AC4825 Series Replacement Filter FILTER B (FLT4825) AC5000 Series Replacement Filter FILTER C (FLT5000)
NOTE: Do NOT stick any foreign objects or your fingers inside of the unit. CAUTION: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in
NO
TE: The Combination Filter is one filter system. The multiple layers include:
the Pre-/Charcoal Filter and the Filter.
the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.
AIR PURIFIER
Use a clean, dry, soft cloth to wipe the external surface of the unit.
E-8 E-9
Page 6
INSTALLING & REMOVING UV-C BULB
INSTALLING & REMOVING UV-C BULB
CHANGE BULB INDICATOR
The blue light on the front of air cleaner will begin to flash continuously when it is time to replace the UV-C bulb. Replace the bulb according to the directions then press the UV control button and hold for 5 seconds to restart the system. The light should remain a constant blue.
REPLACE BULB
Continue reading below for remaining instructions on how to Install & Remove the UV-C Bulb for the AC4825 Series and the AC5000 Series.
1. Remove the Rear Cover
of the unit by pushing Lock & Release Button.
2. After removing the Rear Cover from the unit, remove the Combination Filter.
AC4825 SERIES
AC5000 SERIES
TWIST BULB 1/4 TURN TO REMOVE BULB
3. After removing the Combination Filter, use a Philips head screwdriver to remove four (4) screws and detach the UV-C Metal Shield.
5. The UV-C Bulb is reinstalled by reversing the process in Step 4.
6. Push and hold UV Control Button for 5 seconds to reset UV Bulb Change Indicator.
REPLACEMENT BULB: LB5000
AVAILABLE AT 866.603.5900 OR WWW.GUARDIANTECHNOLOGIES.COM
4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and twisting the bulb 1/4 turn. Remove from unit.
Bulb is NOT visible until the UV-C METAL SHIELD has been removed.
IMPORTANT: The UV-C Bulb should be replaced every 10 - 12 months depending on use.
Please contact Customer Service at 1.866.603.5900 or visit us at
PULL UV-C BULB STRAIGHT OUT OF UNIT
Bulb is NOT visible until the UV-C METAL SHIELD
3. After removing the Combination
Filter, use a Philips head screwdriver to remove two (2) screws and detach the UV-C Metal Shield.
5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit.
6. Push and hold UV Control Button for 5 seconds to reset UV Bulb Change Indicator.
REPLACEMENT BULB: LB4000
AVAILABLE AT 866.603.5900 OR WWW.GUARDIANTECHNOLOGIES.COM
E-10 E-11
4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit.
has been removed.
www.guardiantechnologies.com to purchase a replacement bulb.
Page 7
TROUBLESHOOTING GUIDE
LIMITED WARRANTY
PROBLEM SOLUTION
Unit does not operate. Check that the unit is plugged in.
Call Customer Service 1.866.603.5900.
Unit shuts off unexpectedly.
No air circulating from unit.
Increase in noise level. Make sure the filters are clean. Replace if necessary. Power light is red and flashing. Replace filter and reset system. See E-7. Blue UV-C light is flashing. Replace bulb and reset. See E-10, E-11.
heck that the unit is plugged into a working
C electrical outlet. Check that the Filter is firmly in place. Check that the Rear Cover is latched firmly in place. Call Customer Service 1.866.603.5900.
plug unit. Check Pre-/Charcoal Filter.
Un Clean Pre-/Charcoal Filter if necessary. Replace Filter if necessary.
REPLACEMENT PARTS
To Purchase Contact Customer Service at
1.866.603.5900 or visit www.guardiantechnologies.com
AC4825 SERIES AC5000 SERIES
To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. Save your original sales
receipt to validate start of warranty period. Warranty is not valid without receipt. If this product should become defective within the warranty period, we will repair or replace any
defective parts free of charge. All warranty repairs must be completed by Guardian Technologies LLC. This warranty does not cover unauthorized repairs. The warranty does not include unusual wear, damage resulting from accident, or unreasonable use of the product. This warranty only covers the product when used with genuine Guardian Technologies accessories. This warranty covers product that was purchased from authorized distributors. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in
the U.S.A.)
The product warranty registration can be completed online at www.guardiantechnologies.com. We consider the registration process important to ensuring
superior service to our customers, however submitting the warranty registration is optional and does not affect your rights to utilize this warranty according to the conditions stated above. To submit product under warranty the complete machine must be delivered pre-paid to Guardian Technologies LLC. Please include complete information including: the problem, the model number of the product, the day of purchase, and a copy of the original sales receipt along with your name, address, and telephone (email optional). Address returns to the attention of: Customer Service, at the address below. Additional questions or comments can be made toll free to the number listed below.
Guardian Technologies LLC
26251 Bluestone Blvd.
Euclid, Ohio 44132
1.866.603.5900
www.guardiantechnologies.com
Replacement UV-C Bulb
Model No. LB4000
FILTER B or FILTER B PET Replacement Filter
Model No. FLT4825
FILTER C or FILTER C PET Replacement Filter
Model No. FLT5000
Replacement UV-C Bulb
Model No. LB5000
This warranty can be registered online at www.guardiantechnologies.com.
Additional copies of the instruction manual can be obtained by accessing and
printing directly from our website or calling customer service.
Check out our on-line Filter Reminder and Replacement program.
www.guardiantechnologies.com