![](/html/a4/a4a8/a4a80880afd8141955e39aaa080d13d1039a261faf6dfd9988b1386fd75be564/bg1.png)
Industrial Communications Worldwide
Industrial Telephone
Model HR60
Installation & Operation
7552 - 10th Street N.E. Calgary, Alberta, Canada T2E 8W1
Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com
P002781 Rev. E 11/23/2004 10:05
![](/html/a4/a4a8/a4a80880afd8141955e39aaa080d13d1039a261faf6dfd9988b1386fd75be564/bg2.png)
Guardian Telecom Inc.
Installation and Operation
Model HR60
Table of Contents
Package Contents.................................................................................2
HR60 Models and Options....................................................................2
Accessories...........................................................................................2
Overview...............................................................................................3
Features................................................................................................3
Installing the HR60................................................................................5
Field Repairs.........................................................................................6
Maintenance..........................................................................................6
Engineering Specifications....................................................................7
Warranty................................................................................................8
Disclaimer .............................................................................................8
Warning.................................................................................................8
Service Telephone Number ..................................................................8
Feedback ..............................................................................................8
Guardian Product Return......................................................................9
Table of Figures
Figure 1 - Mounting...............................................................................4
Figure 2 - Dimensions...........................................................................4
Figure 3 - Internal Layout & Wiring .......................................................4
Package Contents
(1) HR60 Telephone
(1) Installation & Operation Manual
HR60 Models and Options
• P6260 - Standard telephone with 7/8” Knock out
• P6264 - Standard telephone with ½” NPT conduit hub
Accessories
• P7225 - Weatherproof ring detect relay
• P7229 - Weatherproof off-hook detect relay (24V)
Page 2
![](/html/a4/a4a8/a4a80880afd8141955e39aaa080d13d1039a261faf6dfd9988b1386fd75be564/bg3.png)
Guardian Telecom Inc.
Installation and Operation
Model HR60
Overview
HR60 Severe Environment Telephone
The HR60 Telephone is designed to provide safe, reliable communication in harsh environments
such as refineries, mills, plants, warehouses and areas prone to high humidity.
Features
Enclosure
• 16 AWG steel, zinc dichromate plated and powder coated
Keypad
• durable standard 3 x 4 keypad
Hook Switch
• magnetic reed hook switch; no moving parts
Surge Arrestor
• prevents damage to the electronic circuits in the event of a high
voltage spike on the telephone line
Noise Reducing Microphone
• aids in clarity of transmission in noisy areas
Tone (DTMF) Operation
• factory set to tone (DTMF) dialing
• pulse dialing can be ordered or configured in the field
Heavy Duty Handset Cord
• withstands severe use
Hearing-Aid Compatible
• compatible with inductively coupled hearing-aid devices
Page 3
![](/html/a4/a4a8/a4a80880afd8141955e39aaa080d13d1039a261faf6dfd9988b1386fd75be564/bg4.png)
Guardian Telecom Inc.
Installation and Operation
Model HR60
2.7" [69mm]
]
m
m
3
6
1
[
"
4
.
6
for #10 or M5
Figure 1 - Mounting
5.0" [127mm] 5.1" [130mm]
]
m
m
9
2
2
[
"
0
.
9
Figure 2 - Dimensions
2.2" [56mm]
HOUSING
SURGE ARRESTOR
HS
HK
RINGER
1/4A, 250V
FUSE
TIP
RING
TERMINAL STRIP
GROUND
TONE/PULSE
JUMPER
Figure 3 - Internal Layout & Wiring