MODEL NO. H2500
3 Year Limited Warranty
www.guardiantechnologies.com
1-866-603-5900
REV0712
Date Purchased
month
year
E-1
READ AND SAVE THIS MANUAL
PRODUCT SPECIFICATIONS AND PARTS
SPECIFICATIONS
Model Number: H2500
Humidifying Mode: Combination
Power Supply: AC120V, 60Hz
Power Consumption: 140W (40W at cold humidification)
Maximum humidity capacity: About 350cc/Hr. (at highest setting and warm humidification)
Tank Capacity: 1.4 Gallons (5.29 Liter)
Dimensions: Width-14.5 inches; Length-9 inches; Height-12 inches
Weight: 8.8 Pounds (not including packaging)
FUNCTIONS AND FEATURES
Warm or Cool Humidification Selection
Select humidifying temperature based on need. Warm humidity will use more power but will
humidify your room quicker.
Water Shortage Indicator
When the unit is low on water the Refill LED on the front panel will light up, and the unit will
shut off. Simply add more water to continue use.
Humidity Adjustment
The humidity volume may be adjusted based on need by using the humidity dial on the
front panel.
PARTS
Tank Lid
*Cleaning brush is
located in base of unit.
Cleaning
Brush
Power Plug
Night Light Button
Humidity Dial
Mode Dial
Night Glow
Body
Humidity Spray Spout
Handle
Water Tank
Spout Guide
Power LED
Refill LED
Air-Cleaning
Filter
Silver Clean Technology
Unlike other humidifiers that grow slimy mold and mildew, this Ultrasonic Humidifier uses
Silver Clean™ Technology embedded in the tank to fight the growth of mold and mildew on the
surface of the water tank.
Night Light
Provides soft light with on/off switch.
WARNINGS
This product should be used only in accordance with the specifications outlined in this
!
manual. Usage other than what has been specified here may result in serious injury.
· Disassembly, repair or remodeling by an unauthorized person may result in serious harm.
· Do not use if plug is damaged or loose.
· Keep this product out of the reach of children and pets.
· Be careful not to put water in the humidity spout.
· Before filling or cleaning the unit, make sure it is unplugged.
· Once the humidifier has been turned on, do not move it.
· Do not remove the water tank from the unit while it is on.
· Do not handle the plug with wet hands.
· Do not excessively bend, twist or pull the power cord.
· Avoid placing this product where the humidity spout is pointed directly at an object.
· Do not directly inhale the mist from the humidity spray spout.
· Do not place this product on a sloped or unstable surface.
· When not in use, unplug the unit.
· Do not fill the water tank with hot or boiling water.
· Do not use this product in direct sunlight, or near a gas stove or heater.
· If the water tank becomes cracked or damaged, do not use.
· Do not keep this product running for an extended period of time without proper maintenance.
· Do not clean the unit or water tank with detergents or chemicals of any kind.
· Do not use this product near any other electronic device.
· Do not cover the humidity opening at any time during use.
· Do not use this product near a sink.
· Do not drink water from tank.
· Do not place this product on an absorbent surface.
E-2E-3
WARNINGS (cont.)
H
U
M
I
D
I
T
Y
NIGHT LAMP
· Do not pour anything but water into the water tank.
· Children cannot recognize the hazards associated with the usage of electrical appliances.
For this reason, always supervise children when they are near the humidifier.
· If the mist comes in contact with the floor prior to evaporating, the floor surface may be damaged.
We do not accept any liability for damage in the case of the unit being placed incorrectly.
· The use of water additives, such as ethereal/essential oils, fragrances, eucalyptus, water
conditioners, etc. will damage the appliance materials and as a consequence the whole unit. Any
use of such additives will void the manufacturers warranty.
· IMPORTANT: Neither humans nor animals can hear the high frequency vibrations.
Failure to comply with the warnings listed above may result in electric shock or serious injury.
DIRECTIONS FOR USE
Make sure the unit is unplugged.
DIRECTIONS FOR USE (cont.)
5. Attach the water tank to the body of the
unit and plug in.
6. Turn the Mode dial to either cool or warm.
The Power LED will light up.
1. Separate the tank from the body of the unit.2. Turn water tank over. Open tank lid,
twisting the cap to the left.
3. Pour cool, clean water directly into the tank.
4. Close the tank lid, turning it to the right.
Do not pour anything but water into the
water tank.
7. Turn the Humidity dial to the desired
volume of humidity. Toward the right and
the humidity level increases, toward the left
and the humidity level decreases.
9. To turn night light on or off, press button.
8. As soon as the Refill LED lights up, turn the
unit off and refill the water tank.
E-4E-5
MAINTENANCE
· Always unplug the unit before servicing it in any way.
· The water temperature of the water remaining in the unit after use may be high.
· Do not submerse the unit in water, or allow water to enter the inside of the unit.
TROUBLESHOOTING GUIDE
PROBLEMSOLUTION
INSIDE THE BODY OF THE UNIT
Pour excess water out of the unit, but do not allow it to enter the spout guide. Wash out the
unit with fresh water, using ONLY the cleaning brush and a soft cloth as needed.
OUTER SURFACE OF THE UNIT
Wipe the surface of the unit with a soft damp cloth if needed.
WATER TANK
If water spots remain in the water tank, wipe the inside down with a soft cloth. Do not use
soap or detergents.
AIR FILTER
Gently wipe away debris from the filter with a soft cloth.
ULTRASONIC DISK
Remove spray spout (Fig. 1) and use the enclosed cleaning brush to regularly remove build up
and deposits from this area (Fig. 2). Diluted white vinegar will help to prevent this build up.
*Clean the disk with
the brush only. No
other cleaning tool
should be used.
Brush only. (Fig. 2)
Fig. 1Fig. 2
Water mist & humidity are not
produced.
Air blows but water mist is
not produced.
Humidity level is low.The surface of the ultrasonic disk is dirty. Clean with
Warm humidity is not produced.It may take 10-15 minutes before warm humidity is
Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try again.
Water Tank Installation: Make sure the water tank is
correctly attached. Make sure spring on tank cap moves
freely when pushed.
Excessive Water: Remove water tank. Empty a small
amount of water from the base of the unit.
The desired humidity is lower than the current
temperature: increase the desired humidity.
Detergent residue in the water tank: Wash the water tank
out and try again.
white vinegar.
The water in the unit is too cold: Replace with cool, but
not cold water.
If ultrasonic disk is damaged contact customer service
at 866-603-5900.
created. The mist may not feel warm to the touch. Check
to see if base of unit feels warm to the touch. If so then
warm mist is being produced.
STORAGE
· Fully dry the inside and outside of the unit before storing it.
· DO NOT leave water in the unit.
· Store in a cool dry place.
The humidity has a bad smell.Poor maintenance or dirty water: Clean the product
White dust is forming on nearby
furniture.
thoroughly, and fill it with fresh water.
Hard water may deposit a certain amount of dust. Dust in
the air also settles because of added humidity in the room.
*Use distilled water if this becomes a nuisance.
Or order a Decalcification Filter (FLTDC) by calling
1-866-603-5900 or visiting www.guardiantechnologies.com
E-7E-6
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.