Guardian H1000 Owner's Manual

USE & CARE INSTRUCTIONS
Guardian Technologies LLC
7700 St Clair Avenue | Mentor, Ohio 44060
1.866.603.5900 | www.germguardian.com
©2007 Guardian Technologies LLC
Table Top Ultrasonic
Model No. H1000
3-Year Limited Warranty www.germguardian.com
1.866.603.5900
Humidier
English E - 1 French F - 1 Spanish S - 1
Date Purchased
month ________ year _________
E-1
PRODUCT SPECIFICATIONS AND PARTS FUNCTIONS AND FEATURES
SPECIFICATIONS
Model Number: H1000 Humidifying Mode: Ultrasonic Power Supply: AC120V, 60Hz (Adapter AC120V / AC 24V) Power Consumption: 18W Humidity Capacity: About 110cc/hr Tank Capacity: 0.23 gallons Successive Humidity Hours: 8 hours or more depending on environmental conditions Dimensions: Width 7.9 inches - Height 8.5 inches - Depth 3.5 inches Weight: 1.32 pounds (Not including packing adapter)
PARTS
Water Shortage Indicator
When the unit is low on water, the Rell Indicator LED on the body will change from green to red, and the unit will shut off. Simply add more water to continue use.
Mist Director
The mist director can be selected through 360° by turning the spout.
Cleaning Brush Storage
E-2 E-3
Failure to comply with the warnings listed above may
result in electric shock or serious injury.
WARNINGSWARNINGS
Failure to comply with the warnings listed above may
result in electric shock or serious injury.
This product should be used only in accordance with the specications outlined in this manual. Usage other than what has been specied here may result in serious injury.
WARNING: THE CORDS, WIRES AND/OR CABLES SUPPLIED WITH THIS PRODUCT CONTAIN CHEMICALS, INCLUDING LEAD OR LEAD COMPOUNDS, KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARMS, WASH HANDS AFTER USING.
Disassembly, repair or remodeling by an unauthorized person may result in serious harm.• Do not use if adapter plug is damaged or loose.• Keep this product out of the reach of children and away from pets.• Be careful not to put water in the humidity spout.• Before lling or cleaning the unit, make sure it is unplugged.• Once the humidier has been turned on, do not move it and do not disassemble the water tank.• Do not move when in operation.• Do not remove the water tank from the unit while it is on.• Do not handle the adapter plug with wet hands.• Do not excessively bend, twist or pull the adapter cable.• Avoid placing this product where the humidity is pointed directly at an object.• Do not directly inhale the humidity.• Do not place this product on a sloped or unstable surface.• When not in use, unplug the unit.• Do not ll the water tank with hot or boiling water.• Do not use this product in direct sunlight, or near a gas stove or heater.• If the water tank becomes cracked or damaged, do not use.• Do not keep this product running for an extended period of time.• Do not clean the unit or water tank with detergents or chemicals of any kind.• Do not use this product near any other electronic device.• Do not cover the humidity opening at any time during use.• Do not use this product near a sink.• Do not place this product on an absorbent surface.• Do not pour anything but water into the water tank.• Children cannot recognize the hazards associated with the usage of electrical appliances. For this •
reason, always supervise children when they are near the humidier. If the mist comes in contact with the oor prior to evaporating, the oor surface may be damaged. •
We do not accept any liability for damage in the case of the unit being placed incorrectly. The use of water additives, such as ethereal/ essential oils, fragrances, eucalyptus, water condi-•
tioners, etc. will damage the appliance materials and as a consequence the whole unit. Any use of such additives will void the manufacturer's warranty.
IMPORTANT: Neither humans nor animals can hear the high frequency vibrations.•
Do not tilt or move the unit when unit is plugged into outlet.• When unplugging from outlet hold humidier securely.• Do not put water in the spout.• Do not damage the adapter cord.• Do not place adapter cable over objects.• Be careful not to get water in or on the power cord adapter or where it connects to the product.• Do not touch water tank during operation.• Do not submerse the unit in water or pour water on the unit.• When emptying water from water tank, pour on drain side.• Be careful not to put any detergent, any oils, any chemicals into water reservoir and/or tank.• Do not place this product on cloth, carpet or vinyl. This may block air inlet.• Unplug the adapter when unit is not in use for an extended period of time and/or when no one is • present in the home. Do not drink the water from the tank.• Do not cover the spout with a cloth or your hand and do not use without the spout.• Do not keep water in the tank when not in use for an extended period of time.• Do not put anything in the tank.• Do not use the product near a gas oven range.• Use clean or distilled water in the tank.• Do not place anything on water tank or damage product by dropping.•
Failure to comply with the warnings listed above may result in electric shock or serious injury.
E-4 E-5
Make sure the unit is unplugged.
1. Separate the tank from the body of the unit.
F
A
N
S
E
T
S
E
O
N
O
L
2. Open the tank lid, turning it to the left.
F
A
N
S
E
T
S
E
O
N
O
L
Always unplug the unit before servicing it in any way.• Do not submerse the unit in water, or allow water to enter the inside of the unit.•
INSIDE THE BODY OF THE UNIT
Pour excess water out of the unit. Wash out the unit with fresh water, using the cleaning brush and a soft cloth as needed.
OUTER SURFACE OF THE UNIT
Wipe the surface of the unit with a soft damp cloth if needed.
WATER TANK
Fill water tank with clean water and shake to remove water scaling.
ULTRASONIC DISK
Remove the water tank (Figure 1) and use the enclosed cleaning brush regularly to remove build up and deposits from this are (Figure 2).
Do not use any detergents or soap as this may damage the ultrasonic disc. This may also disperse detergent or soap residue with mist causing bodily harm.
Do not scrub with nger tips or any sharp objects as this may cause damage to the ultrasonic disc.
If there is red color build up on ultrasonic disk, gently clean with soft cloth and 1-2 drops of white vinegar. Rinse with clean water.
3. Pour cool, clean water directly into the tank. Do not pour anything but
4. Close the tank lid, turning it to the right.
water into the tank.
5. Attach the tank to the body of the
6. Press the button to turn on.
unit and plug in.
Fully dry the inside and outside of the unit before storing it.• DO NOT leave water in the unit.• Store in a cool, dry place.•
E-6 E-7
PROBLEM SOLUTION
Water vapor & humidity are not produced. Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try again. Make sure the water is in the tank and the tank is correctly attached. Clean the ultrasonic disc and its periphery.
Air blows but water vapor is not produced. Excessive Water: Remove a certain amount
of water from the tank. Detergent residue and/or oil ingredients from cosmetics, etc may be in tank; wash out tank and try again. Clean the ultrasonic disk and its periphery. If you use hard water, replace with softer water.
Humidity level is low. The surface of the ultrasonic disc is dirty:
Clean the ultrasonic disc and its periphery. The water in the unit is too cold: Replace with cool, but not cold water.
The humidity has a bad smell. Boil clean water and let cool. Use water
after 24 hours. Poor maintenance or dirty water: Clean product thoroughly and ll with fresh water.
White dust forming on nearby furniture. Hard water deposits a certain amount of
dust. Use distilled water if this becomes a nuisance.
To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials and workmanship commencing the date of the original purchase. Save your original sales receipt to validate start of warranty period.
If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. The complete machine must be delivered pre-paid to any authorized Guardian Technologies LLC warranty service center. Please include complete information on the problem, day of purchase, copy of original sales receipt and your name, address and telephone number. If you are not near a warranty station, call the factory for assistance in the US and Canada at 1.866.603.5900. Use only genuine Guardian Technologies replacement parts.
The warranty does not include unusual wear, damage resulting from accident or unreasonable use of the product. This warranty does not cover unauthorized repairs. This warranty gives you specic legal rights and you may also have other rights (other rights may vary from state to state in the U.S.A).
We consider the registration process important to ensuring superior service to our customers, however submitting this card to Guardian Technologies LLC is optional and does not affect your rights to utilize this warranty according to the conditions stated above. If you have any questions or comments about our product call toll free at 1.866.603.5900 or send comments to:
ATTN Customer Service Guardian Technologies LLC 7700 St Clair Avenue Mentor, Ohio 44060
Guardian Technologies LLC
7700 St Clair Avenue | Mentor, Ohio 44060
E-8 E-9
1.866.603.5900 | www.germguardian.com
©2007 Guardian Technologies LLC
Loading...
+ 9 hidden pages