Guardall PX18, PX34, PX80, PX500 User Manual

PX Control Panel
User Manual
Issue C
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 2 -
CONTENTS...............................................................................................................................................................................2
INTRODUCTION.....................................................................................................................................................................5
EVENT LOG.............................................................................................................................................................................5
AREAS & SET G ROUPS.........................................................................................................................................................5
CIRCUITS................................................................................................................................................................................5
USER , SET GROUP AND CIRCUIT IDENTIFICATION ........................................................................................................6
USER CODES...........................................................................................................................................................................6
OPERATOR CONTROLS AND DISPLAYS ......................................................................................................................6
SYSTEM KEYPADS................................................................................................................................................................6
Electronic Keys................................................................................................................................................................7
Proximity Tokens.............................................................................................................................................................7
KEYSWITCH ...........................................................................................................................................................................7
USING THE SYSTEM..............................................................................................................................................................7
LOGGING ON ...........................................................................................................................................................................7
MENU FORMAT .....................................................................................................................................................................8
MENU LAYOUT........................................................................................................................................................................9
MENU LAYOUT.....................................................................................................................................................................10
INVALID USER CODES.........................................................................................................................................................11
USER ACCESS TIME.............................................................................................................................................................11
ENGINEER ON SITE.............................................................................................................................................................11
MENU RESTRICTIONS ........................................................................................................................................................11
LOGGING OFF.......................................................................................................................................................................12
HELP .....................................................................................................................................................................................13
Remote Service..............................................................................................................................................................13
Contract.........................................................................................................................................................................13
Product Info...................................................................................................................................................................13
KEYPAD BACKLIGHT.........................................................................................................................................................13
LOG ON MESSAGES ..............................................................................................................................................................13
DUAL USER CODE OPERATION ........................................................................................................................................14
UNSET .....................................................................................................................................................................................14
UNSETTING METHODS ......................................................................................................................................................14
Unsetting from a keypad.............................................................................................................................................14
Unsetting from a keyswitch.........................................................................................................................................16
Automatic Unsetting....................................................................................................................................................16
UNSETTING WARNINGS.....................................................................................................................................................16
UNSETTING AFTER AN ALARM.......................................................................................................................................16
SET...........................................................................................................................................................................................17
SETTING FROM A KEYPAD................................................................................................................................................17
KEYSWITCH SETTING........................................................................................................................................................17
AUTOMATIC SETTING ......................................................................................................................................................18
Aborting The Setting Procedure................................................................................................................................18
SETTING WITH WARNINGS...............................................................................................................................................18
SETTING FAULTS................................................................................................................................................................18
FAILURE TO SET AFTER EXIT TIME ...............................................................................................................................19
RESET......................................................................................................................................................................................20
CUSTOMER RESET ..............................................................................................................................................................20
ENGINEER RESET ................................................................................................................................................................20
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 3 -
MANAGED RESET ...............................................................................................................................................................20
TEST........................................................................................................................................................................................21
SOUNDER..............................................................................................................................................................................21
STROBE.................................................................................................................................................................................21
AUDIO...................................................................................................................................................................................21
WALK TEST .........................................................................................................................................................................21
COMMS TEST .......................................................................................................................................................................23
ENGINEER ..............................................................................................................................................................................23
CODE.......................................................................................................................................................................................23
USER........................................................................................................................................................................................24
NAME ....................................................................................................................................................................................24
CODE .....................................................................................................................................................................................25
AUTHORITY ........................................................................................................................................................................25
CODE CHANGE.....................................................................................................................................................................26
LOGON/SET ..........................................................................................................................................................................26
SCHEDULE 1-2 (PX18/34)...................................................................................................................................................28
SET G ROUP 1-MAX .............................................................................................................................................................28
DOOR 1-2 (PX18/34)............................................................................................................................................................28
SCHEDULE (PX80/500).......................................................................................................................................................28
DOOR ACCESS (PX80/500)..................................................................................................................................................28
Challenged....................................................................................................................................................................28
LOCKOUT (PX80/500).........................................................................................................................................................28
EXPIRY DATE (PX80/500)..................................................................................................................................................28
LOGS .......................................................................................................................................................................................30
EVENT LOG MESSAGES.......................................................................................................................................................30
PRINTED LOG.......................................................................................................................................................................30
LOG-FULL .............................................................................................................................................................................31
LOG-CCT ...............................................................................................................................................................................31
LOG-USER.............................................................................................................................................................................31
LOG-KP.................................................................................................................................................................................31
LOG-DATE............................................................................................................................................................................31
LOG-ALARM.........................................................................................................................................................................31
A/LOG-FULL........................................................................................................................................................................31
A/LOG-USER .........................................................................................................................................................................31
A/LOG-DOOR.......................................................................................................................................................................31
LOG MESSAGES....................................................................................................................................................................32
TIME.........................................................................................................................................................................................36
HOLIDAY ................................................................................................................................................................................37
START...................................................................................................................................................................................37
END........................................................................................................................................................................................37
SET G ROUP (PX80/500) ......................................................................................................................................................37
SET G ROUP 1-8 (PX34) .......................................................................................................................................................37
SCHEDULE (PX18 & 34) .....................................................................................................................................................38
SCHEDULE.............................................................................................................................................................................38
START TIME ........................................................................................................................................................................38
STOP TIME...........................................................................................................................................................................38
MON-SUN .............................................................................................................................................................................38
HOLIDAY ..............................................................................................................................................................................38
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 4 -
SCHEDULE (PX80 & 500)..................................................................................................................................................39
SET GROUP ...........................................................................................................................................................................39
BYPASS..................................................................................................................................................................................40
KEYPAD OFF.........................................................................................................................................................................40
CHIME.....................................................................................................................................................................................40
PRINT TEXT .........................................................................................................................................................................41
PRINT HOLS.........................................................................................................................................................................41
ACCESS FEATURES ............................................................................................................................................................42
SECURITY SYSTEM INTEGRATION ..................................................................................................................................42
ADD USER............................................................................................................................................................................43
DELETE USER......................................................................................................................................................................43
IDENTIFY USER...................................................................................................................................................................43
DOOR UNLOCK....................................................................................................................................................................43
DOOR LOCKOUT..................................................................................................................................................................44
DOOR TEXT .........................................................................................................................................................................44
ISOLATE CCT .......................................................................................................................................................................44
ISOLATE CONC....................................................................................................................................................................44
CCT STATUS.........................................................................................................................................................................45
SYSTEM DETAILS ...............................................................................................................................................................46
KEYPADS..............................................................................................................................................................................46
SET G ROUPS.........................................................................................................................................................................46
CIRCUITS..............................................................................................................................................................................48
USERS....................................................................................................................................................................................50
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 5 -
Introduction
The PX Electronic Intruder Alarm System is designed to provide secure protection for the installation. The system is highly versatile, permitting individual systems to be installed and programmed to meet the particular security requirements of each installation.
The system comprises a main control panel, normally located out of sight in a secure area, and at least one keypad.
The panel has a wide range of features, which are programmed by the engineer on installation, to suit the security requirements of the particular installation. Some of the features may be reprogrammed, edited, or viewed as required by an authorised user.
Event Log
The system incorporates an event log capable of recording the at least 250 events. The actual number of event stored is dependent on the panel type as shown in the table.
Feature PX18 PX34 PX80 PX500
Security event log 250 250 500 1000 Access Log 1000 1000 1000 1000
The event log will record all events, for example, user log-on times and user numbers, keypad numbers, setting and unsetting times, alterations made to programmed settings, fault conditions, etc. When the event log is full, the oldest event will be automatically removed when the next event occurs.
All log events are date and time stamped and may be viewed, or printed if a printer is fitted to the system.
Areas & Set Groups
For protection purposes, the premises may be divided into a number of areas. Individual areas may be grouped together into a setting group which provides the user with a convenient way of setting and unsetting more than one area at the same time.
The installation company engineer will have configured your system for the appropriate number of areas and groups to comply with your specific security requirements.
Where more than one area is incorporated in the system, an area(s) can be configured by the installation engineer as a common area. A common area will automatically set if all other areas of the system are set and will automatically unset if any one of the other areas is unset.
Circuits
Each detector or sensor in the installation is allocated a unique circuit number. The installation engineer will have programmed each circuit to respond in a certain way when the circuit is activated, when the area is set and unset. The way in which the circuit is programmed to respond will depend on the type of circuit and its location and purpose.
If a circuit is faulty, the alarm response may be turned off by an authorised user. This process is referred to as bypassing.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 6 -
User, Set group and Circuit Identification
Each user, set group, and circuit can be programmed with a text description. An authorised user can change a user text descriptor.
User Codes
Each user of the system is identified by a unique code. This code can be a PIN code, an electronic key or proximity token. An electronic key can only be used on a keypad variant with an electronic key interface. A proximity token can only be used on a keypad variant with a proximity interface.
Throughout this manual user codes are only referred to as codes.
Operator Controls and Displays
System Keypads
2 x 16 character LCD backlit display
Mains indicator
Optional electronic key socket
The operator keypad unit incorporates a backlit liquid crystal display (LCD) comprising 2 lines of 16 characters, and a backlit keypad to gain access to the system and to perform all authorised user functions. Keypads may be fitted with an electronic key socket or an internal proximity reader. The keypad incorporates a mains power indicator. This indicator will flash if the system is operating on standby battery power.
12:00 Mon 20 Dec
Guardall
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 7 -
Electronic Keys
A user PIN code can be replaced by an electronic key. To use the facility at least one keypad in the system must have the optional electronic key interface fitted.
All Guardall electronic keys are manufactured with a unique code and duplicate keys cannot be obtained. Spare or replacement keys can be obtained from the installation company.
Proximity Tokens
A user PIN code can be replaced by a proximity token if the keypad is fitted with the optional proximity reader. There are 2 types of token available; a card or key fob.
All Guardall proximity tokens are manufactured with a unique code and duplicate tokens cannot be obtained. Spare or replacement tokens can be obtained from the installation company.
Keyswitch
As an alternative method of setting and unsetting, a simple On/Off keyswitch may be fitted to the system.
Using the System
When no user is logged on to a keypad, the time, date and company will normally be displayed.
12:00 Mon 27 Sep
Guardall
The LCD keypad will normally display the time, date and company name.
Logging on
A user logs on to the system by either:
1. Entering a user PIN code followed by 4
2. Inserting an electronic key
3. Presenting a proximity token
The system will check that the entered user code is valid before permitting access to the system user functions.
12:00 Mon 27 Sep
Enter-
****
When a PIN code is entered the display will show an asterisk for each digit.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 8 -
Menu Format
User Menu
01=Unset 02=Set
03=Reset 04=Test 05=Engineer 06=Code 07=User 10=Log-Full 11=Log-Cct 12=Log-User 13=Log-KP 14=Log-Date 15=Log-Alarm
The user menu shown has all possible options available. The actual options available to a user will depend on the user authority, the system configuration and the current system status.
Only 2 options will be visible on the display but all available options can be selected by entering the 2-digit code without viewing the actual option number.
16=A/Log-Full 17=A/Log-User 18=A/Log-Door 20=Time 24=Holiday 25=Schedule 26=SetGroup 30=Bypass 31=KP Off 32=Chime 40=Print Text 42=Print Hols. 50=Add User 51=Delete User 52=Identify User 53=Door Unlock 54=Door Lockout 55=Door Text 71=Copy User 73=Copy A/User 86=Isolate Cct 87=Isolate Conc 89=Cct Status
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 9 -
PX 18/34
Menu Layout
The menu map shows all possible menu options and, where appropriate, sub menus.
01=Unset 02=Set 03=Reset 04=Test 05=Engineer 06=Code 07=User 10=Log-Full 11=Log-Cct 12=Log-User 13=Log-KP 14=Log-Date 15=Log-Alarm 16=A/Log Full 17=A/Log User 18=A/Log Door 20=Time 24=Holiday 25=Schedule 26=Set Group 30=Bypass 31=KP Off 32=Chime 40=Print Text 42=Print Hols. 50=Add User 51=Delete User 52=Identify User 53=Door Unlock 54=Door Lockout 55=Door Text 71=Copy User 73=Copy A/User 86=Isolate Cct 87=Isolate Conc 89=Cct Status
1=Group 1 2=Group 2 . . . 8=Group 8
Area Number-?
User Number- _ _
1=Display 2=Print
Engineer Guardall
Circuit Number-__
Time 00:00
Holiday Number-__
Circuit Number-__
01 04 05
30, 322420
02
1=Sounder 2=Audio 3=Strobe 4=Walk Test 5=Comms Test
1=Silent Set 2=Instant Set
?
07
New Code Enter-
06
11
User Number-__
12, 1710, 15, 16
Keypad Number-_
13
Filter Date EnterDDMMYYYY
14
Holiday 1 Start-Off End-Off Set Group-00
Keypad Number-_
31
Printing Text
Printing Holiday
4240
Schedule Number-__
25
Schedule-n Start Time- 00:00 Stop Time- 00:00 Mon-Off Tue-Off Wed-Off Thu-Off Fri-Off Sat-Off Sun-Off Holiday-Off
User-xx "Descriptor" Manager Code Change-On LogOn/Set-On Schedule 1-0 Schedule 2-0
Group 1-Off Group 2-Off
. . .
Group 8-Off Door 1-Off Door 2-Off
3
1=Group 1 2=Group 2 . . . 8=Group 8
1=Name 2=Code 3=Authority
Door Number-__
18
User n Present Card/Fob
Delete Users ___-___
Present Card/Fob
50 51 52
Door Number-_
53, 54, 55
Copy User __ __-__
Copy A/User ____ ____-____
71 73
Concentrator Number-_
87
Circuit Number-__
86
Set Group Number-__
26
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 10 -
PX 80/500
Menu Layout
The menu map shows all possible menu options and, where appropriate, sub menus.
01=Unset 02=Set 03=Reset 04=Test 05=Engineer 06=Code 07=User 10=Log-Full 11=Log-Cct 12=Log-User 13=Log-KP 14=Log-Date 15=Log-Alarm 16=A/Log Full 17=A/Log User 18=A/Log Door 20=Time 24=Holiday 25=Schedule 26=Set Group 30=Bypass 31=KP Off 32=Chime 40=Print Text 42=Print Hols. 50=Add User 51=Delete User 52=Identify User 53=Door Unlock 54=Door Lockout 55=Door Text 71=Copy User 73=Copy A/User 86=Isolate Cct 87=Isolate Conc 89=Cct Status
01=Group 1 02=Group 2 . . . 32=Group 32
Area Number-?
User Number- _ ___
1=Display 2=Print
Engineer Guardall
Circuit Number-__
Time 00:00
Holiday Number-__
Circuit Number-__
01
04
05
30, 32
24
20
02
1=Sounder 2=Audio 3=Strobe 4=Walk Test 5=Comms Test
1=Silent Set 2=Instant Set
?
07
New Code Enter-
06
11
User Number-____
12, 1710, 15, 16
Keypad Number-__
13
Filter Date EnterDDMMYYYY
14
Holiday 1 Start-Off End-Off Set Group-00
Keypad Number-_
31
Printing Text
Printing Holiday
4240
Schedule Number-__
25
User-xx "Descriptor" Manager Code Change-On LogOn/Set-On
Group 1-Off Group 2-Off
. . . Group 32-Off
3
1=Mon 2=Tue 3=Wed 4=Thu 5=Fri 6=Sat 7=Sun 8=Hol
Schedule-n Mon Start 1- 00:00 Stop 1- 00:00 Start 2- 00:00 Stop 2- 00:00
01=Group 1 02=Group 2 . . . 32=Group 32
1=Name 2=Code 3=Authority 4=Door Access 5=Schedule 6=Lockout 7=Expiry Date
User-xx Enable-Off
Door 1-Off Door 1-Off
... Door 1-Off Challenged-Off
4
Expiry Date Enter DDMMYYYY
7
Door Number-__
18
User n Present Card/Fob
Delete Users ___-___
Present Card/Fob
50 51 52
Door Number-__
53, 54, 55
Copy User ____ ____-____
Copy A/User ____ ____-____
71 73
Concentrator Number-_
87
Circuit Number-__
86
Set Group Number-__
26
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 11 -
Invalid User Codes
12:00 Mon 27 Sep
Incorrect Code
If an incorrect user code is entered, the incorrect code message will be displayed for 4 seconds or until another key is pressed.
If more than the programmed number of code attempts are made to enter a valid user code, the keypad will be locked out and the display will show Out of Service for a period of 5 minutes.
12:00 Mon 27 Sep
Out Of Service
Any attempt to enter a user code during the locked out period will extend the period by another 5 minutes
User Access Time
When a user logs on to the system a selection must be made from the user menu within two minutes of log on, otherwise they will be automatically logged off.
Engineer On Site
Engineer
Out Of Service
When an engineer logs on to a keypad, all other keypads in the system will be inoperable and the display will show Out of Service.
Menu Restrictions
If a menu number is entered and the option is not available, then a reason will be displayed. For example if no area is set and you select unset the panel will prompt with the reason the unset option is not available.
Not Available No Set Area
This indicates that there is no set area available to the user.
There are many reasons why an option is not available. If you think an option should be available but the prompt is not on display then enter the menu number and the panel will display an appropriate message. The following table shows the reasons why a menu option is not available:
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 12 -
Not Available Message Where Used
No Authority User tries to select an option that is not allowed with their programmed
authority level.
No Set Area User selects unset when all areas that can be unset from the keypad are
already unset. Timer Control On User attempts to log on outwith the schedule times. No Unset Area User selects set when all areas that can be set from the keypad are already
set. Set Area User attempts to access test when an area is set. Test in Progress User attempts to set an area that is being tested (on another keypad). System Not Unset User attempts to access an option that is only available when the system is
unset, for example the event log. Unset Area User attempts to unset an unset area. Key Not Used The key (button) which has been pressed is never used in the current menu. Printer Busy User attempts to print and the printer is in use. Not Programmed The option selected is not programmed. Keypad Busy User attempts to turn off a keypad that is being used. Not Applicable User attempts, for example, to reset when there are no alarms logged. Option in Use User selects an option, such as test, which is in being used by another
user. At Bypass Limit User attempts to bypass a circuit when the number of bypassed circuits is
at the programmed bypass limit. Call Engineer User attempts to set when an engineer reset is required.
Logging Off
02=Set 05=Eng
Press 7to log off from the main menu.
4=Confirm LogOff Press 4 to confirm log off.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 13 -
Help
The system will display context sensitive help for menu and programming options. When the main menu is on display press the help button (?) to display information about the system.
02=Set The normal log on menu 05=Eng
Press the ? button to display the customer help menu.
Help Menu
0=Remote Service 1=Contract
2=Product Info
Help Menu
Remote Service
The remote service option is only required if your alarm company offers this service. Before using the remote service option you must obtain a number from your alarm company. When you need to use the remote service, you will be prompted to enter this number, and the panel will dial the alarm company. The alarm company will then be able to check the condition of your system and identify and resolve problems.
Help Menu
Contract
The contract number uniquely identifies the system.
Contract
123456
The customer contract number is a 6-digit number programmed by the installation engineer.
Help Menu
Product Info
W73797 v1.00 The panel order code and firmware version number S.Dial v4.0x The SmartDial version number (if fitted)
Press the quit button (7) to return to the normal menu.
Keypad Backlight
The LCD keypad incorporates backlighting. The backlighting will be turned on during the entry time, during code entry and while a user is logged on. It may also be turned on using any button except 4 and 7and turned off using the 4 or 7 buttons.
Log On Messages
When a user logs on, the system may display a special message(s) before the normal menu is displayed. The special messages include:
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 14 -
Message Reason
Alarm Abort User logs on within the alarm abort period (programmable option) Setting Stopped User logs on during the setting exit period Group Unset A group(s) is set and is programmed to automatically unset when a user logs on. Cannot Set The system cannot set, the reason(s) will then be displayed. Unset Alarm An unset alarm has occurred, the details will then be displayed. Mult.Alarm A circuit(s) has alarmed the maximum number of times allowed (programmable).
The circuit details will then be displayed.
Code Known
Another user has chosen your code. You will then be given the option of
immediately changing your code. This message will always be displayed on log
on until the code is changed. Call Engineer You should call the installation company. The details will then be displayed. Reset OK A managed reset code has been accepted Set 4=Confirm
The user is configured for the log on set option. If confirmed the system will start
setting (if only one group is authorised) or display the set group menu. Soak Cct Fails Circuits which have been put on special test by the installation engineer have
alarmed.
Dual User Code Operation
Where a higher level of security is required a keypad may have been programmed to require two user codes to be entered before logging a user on to the system. Both user codes must be authorised and are logged by the system. The authority of the second user code entered is used by the system.
Unset
Code-01
The system will have been partitioned by the installation engineer into a number of set groups. The user authority will determine the choice of groups, which can be unset. There are several methods of unsetting available to the user. These methods are discussed in the following section.
Unsetting Methods
If a set group incorporates an entry route in the unsetting procedure then opening a final entry door to the area will start a pre-programmed entry timer. The user must proceed directly to the keypad or keyswitch via a pre-determined entry route and unset the group as described.
If the group is not unset before the entry time has expired a warning period, equivalent to 50% of the programmed entry time, will be allowed. This is to warn the user that an alarm condition will occur if the group is not unset by the end of the warning period. If the group is not unset by the time that the total entry time and warning time has expired, an alarm condition will be initiated.
During the entry time, if a user deviates from the prescribed entry route into an armed area, the entry time is immediately cancelled. If programmed, a fixed pre-warning period of 45 seconds will be given, otherwise an immediate alarm will be given. If the user enters an armed area during the entry warning period, the warning period is cancelled and an immediate alarm will be given.
Unsetting from a keypad
To unset, log on to the keypad. If an authorised group is configured for automatic logon/unset then the unset group descriptor will be displayed.
Workshop Unset
If more than 1 group is configured for logon/unset then only the first descriptor will be displayed.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 15 -
If automatic logon/unset is not configured then choose the unset option manually.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 16 -
01=Unset 05=Eng
Press 01 to unset
If more than 1 authorised group is set then the available options will be displayed.
1=Workshop 2=Office
Choose the group to unset.
The keypad may be configured to automatically log the user off from the system after unset.
Unsetting from a keyswitch
To unset an area from a keyswitch, turn the keyswitch to the unset position. The area under the control of the keyswitch will immediately unset.
Automatic Unsetting
The system may have been programmed by the installation engineer to automatically unset all or parts of the system according to a pre-programmed schedule. The schedule will have been programmed to take into account the normal opening time, non-working days and holidays.
Unsetting Warnings
When unsetting from a keypad, the user is informed on the display of any warnings, e.g. circuits isolated or on soak. The warning display will appear for approximately 4 seconds during the unsetting procedure. If more than one warning exists, the display will automatically scroll through the list of warnings
Loading Door Isolated
An example of an isolated circuit warning after unsetting.
Unsetting After an Alarm
If an alarm condition has occurred when set, the alarm message will be displayed when the group is unset.
Alarm PIR in Office
An example of an alarm message after unsetting.
If more than one alarm has occurred the display will automatically scroll through the list of alarms. After the last alarm is displayed the reset prompt will be displayed.
4=Reset Press 4 to reset the alarm
If the system is programmed for engineer or managed reset then a special message will displayed. Refer to the reset section for details.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 17 -
Set
Code-02
The system can be partitioned into a number of parts called set groups, each of which can be individually set. The programmed user authority level must allow setting and the programmed user area access will determine which set groups are available to a user.
Setting can be started by:
1. A user request on a keypad
2. A user activating a keyswitch
3. Automatically by a timer schedule
4. Remotely from a PC using the Guardall GuardStation software
5. A user request on an Access module Proximity Reader.
Setting modes include:
1. Instant, where setting is completed immediately
2. Timed, where setting is completed at the end of the programmed exit time
3. Exit point, where setting is completed by opening and closing the final exit circuit
4. Push button, where setting is completed by pushing the external PB circuits after opening and closing the final exit circuit
Setting from a keypad
To set log on and select the set option.
02=Set 05=Eng
Press 02 to set.
If more than 1 authorised group is unset then the available groups will be displayed.
1=Workshop 2=Office
Choose the group to set.
Workshop Setting
The setting message will be displayed
Workshop Seconds Left-005
If timed setting is configured for the group the remaining exit time will be displayed
Workshop Set
When the groups set the set confirm message will be displayed.
If the ? button is pressed while the set group menu is on display the set options will be displayed.
1=Silent Set 2=Quick Set
Choose silent set to set with no exit tone. Choose quick set to ignore the programmed exit time and set instantly.
Keyswitch Setting
As an alternative to setting and unsetting from a keypad, your system may be fitted with an optional keyswitch, which permits setting and unsetting of a group by operating a keyswitch. The keyswitch may be configured for any set mode.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 18 -
Automatic Setting
The system may have been programmed by the installation engineer to automatically set all or parts of the system according to a pre-programmed schedule. The schedule will have been programmed to take into account the normal closing time, non-working days and holidays. The schedule may be configured for any set mode.
Aborting The Setting Procedure
The setting procedure can be aborted at any time during the exit time by pressing 7on the keypad that was used to start setting, logging on to any other keypad or turning a keyswitch to the unset position.
Setting Stopped
If setting is aborted by logging onto a keypad the setting aborted message will be displayed.
Setting with Warnings
The system will automatically display any conditions which the user should be aware of before setting the system. These conditions are described as set warnings and do not prohibit the user from setting the system in the normal way. The user however may wish to change a condition before setting the area(s) or system, where appropriate.
When a user selects set, and warnings exist, the set warning prompt will be displayed.
Set Warning 4=Report Press the 4 button to display the setting warning(s).
Loading Door Isolated
The display will automatically scroll through the list of warnings
Workshop 4=Set Press 4 to proceed with setting or press 7 to cancel setting
The set warnings include:
1. Bypassed circuits
2. Circuits On Soak (a special circuit test mode set up by the installation engineer)
3. Isolated circuits
4. Line Fault (only when setting with telephone line fault is allowed)
Setting Faults
The system will not permit setting with faults or with any circuit open or activated, with the exception of exit route circuits or circuits which have been bypassed or isolated.
When a user selects set, and faults exist, the set warning prompt will be displayed.
Cannot Set
Tamper Rear Door
The display will automatically scroll through the list of faults
The system may have been programmed to allow the user to force set if circuit faults exist.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 19 -
4=Force Set Press the 4 button to try to force set.
If the circuits in fault can be bypassed then the system will report the bypassed circuits and then prompt the user to confirm setting.
Failure to Set after Exit Time
If the group fails to set at the end of the exit period, the exit tone will change to warn the user that the system has not set. Log on to the keypad to display the fault condition(s). The external sounder may also have been programmed by the installation engineer to activate in the event of a failure to set.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 20 -
Reset
Code-03
The resetting method programmed by the alarm company engineer for each area and the system will depend on the particular security requirements of the area or system. There are 3 types of reset:
1. Customer reset, where the customer can reset any alarm
2. Engineer reset, where the alarm company engineer must reset all alarms
3. Managed reset, where the customer can reset an alarm after reporting the event to the alarm company
Customer Reset
If an alarm condition has occurred when set, the alarm message will be displayed when the group is unset.
Alarm PIR in Office
An example of an alarm message after unsetting.
If more than one alarm has occurred the display will automatically scroll through the list of alarms. After the last alarm is displayed the reset prompt will be displayed.
4=Reset Press 4 to reset the alarm
If an alarm condition cannot be reset then a message will be displayed.
Engineer Reset
If the system is configured for engineer reset then after the alarm(s) information is displayed a special prompt will be displayed.
01313333802 Code:123456
The number to call for a service engineer Quote your customer contract number
When an engineer reset is required, it will not be possible to set the system until an engineer has been to the site.
Managed Reset
If the system is configured for managed reset then after the alarm(s) information is displayed a special prompt will be displayed. This feature operates in a similar way to engineer reset. After the call engineer prompt the telephone and code numbers will be displayed.
01313333802 Code:12345
The number to call for a service engineer Quote your code number
The alarm company will issue a special 5-digit PIN code. This PIN code can be used only once to reset the system.
Reset OK Log on using the 5 digit reset code. If the code is accepted this message
will be displayed.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 21 -
Test
Code-04
Each area of the system can be tested individually or all areas can be tested at the same time. The test time is limited to 1 hour. If the user does not end the test by the end of the test time then the panel will exit test mode automatically. When the test option is selected the area test menu will be displayed.
Test Areas Menu
Area Number-?
Enter the area number to test (area 0 for the system).
When an area(s) is selected the test options menu will be displayed.
Test Options Menu
1=Sounder 2=Strobe
3=Audio 4=Walk Test 5=Comms Test
Choose the item that you want to test from the test menu.
Test Options
Sounder
Code-1
The external sounder(s) will be turned on until the user presses the 7button.
Test Options
Strobe
Code-2
The external strobe(s) will be turned on until the user presses the 7button.
Test Options
Audio
Code-3
The internal sounder(s) will be turned on until the user presses the 7button.
Test Options
Walk Test
Code-4
The panel records all activations from sensors during the unset period. When walk test is selected the panel will display all circuits which have not alarmed since the panel was last unset. If all circuits are to be tested then select walk test, then press the 7button and select walk test a second time.
When walk test is selected the keypad will automatically scroll through the list of circuits which have not been tested.
Hall PIR Not Tested
All circuits still to be tested will be displayed.
When all circuits have responded then “All Tested” message will be displayed and the panel will exit walk test:
Walk Test
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 22 -
All Tested
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 23 -
When the panel exits test mode, either manually or automatically at the end of the test time then:
1. Any fire sensor still in alarm will give a normal alarm response.
2. Circuits with a 24-hour response, which are still in alarm, will be temporarily bypassed.
3. A warning will be displayed if any PA sensor is still in alarm.
Test Options
Comms Test
Code-5
If the comms test is selected then the panel will make a test call to all telephone numbers that have been programmed for test by the installation engineer.
Engineer
Code-05
The Eng option will only be available if the system is configured for user authorised engineer access. This option applies to both local and remote engineer access.
When the Eng option is selected the system will prompt for the engineer PIN code to be entered.
Engineer
Guardall
The engineer must log on within 2 minutes. Press 7to cancel the engineer log on authorisation.
Once logged on the engineer working time is limited to 8 hours.
Code
Code-06
All users on the system are identified by a user code. A user code can be a PIN code, an electronic key or proximity token. To change user code, log on to the keypad using your current code and choose the code option. Then follow the display prompts. All user code changes are recorded in the system event log.
Note: If the code option is not available this means that the system has been programmed to prevent you from changing your user code, and a new code must be allocated by the security system manager.
New Code Enter-
The chosen code may be any unique 4, 5 or 6 digit code.
If the entered code is not available the a warning message will be displayed.
New Code Not Available
Re-enter Code Enter-
The new code must be re-entered before being accepted by the system
New Code Does not Match
If the re-entered code does not match a message will be displayed and the system will prompt again for a new code.
New Code Not Available
If the new code is not available you must choose another new code.
If a suitable keypad is used then the user code may be changed to either an electronic key or proximity token. If you are changing code to an electronic key then insert the key when the system prompts for a code. If you are changing code to a proximity token then present the token when the system prompts for a code. When using a proximity token you will not be prompted to re-enter the code.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 24 -
User
Code-07
Feature PX18 PX34 PX80 PX500
Max. Users 20 40 1000 1000 Max. Security 20 40 100 200
A manager user can change the name, user code and authority for any user except the engineer. To modify a user’s details enter the user number in the range 2-max users. The user menu will then be displayed.
The user 2 configuration may only be changed by user 1 or user. Access system users be added quickly using the “Add User” menu option (50).
User Menu
1=Name 2=Code 3=Authority 4=Door Access 5=Schedule 6=Lockout 7=Expiry Date
Choose the required option.
This option is not available on the PX18/34. This option is not available on the PX18/34. This option is not available on the PX18/34. This option is not available on the PX18/34.
User
Name
Code-1
When the name option is selected the current user descriptor will be displayed. Names can be up to 10 characters long and may contain any of the following characters.
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz .-/+#%^&*@<>:!$?_0123456789
By default all names are “User” followed by the user number, for example User 2.
User Number-03 J Smith The first character of the text descriptor will be flashing.
When you edit a name the first letter will be flashing. You can either use the é or ê buttons to select the required character or use one of the numeric keys to quickly access a particular character.
Fast character access buttons
Button 1 2 3 4 5 6 7 8 9
Character A M Z a m z 1 9 space
Use the 4 button to move to the next character position on the right. Press 7to save the descriptor and exit. To clear all characters to the right of the cursor press 0.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 25 -
User Menu
Code
Code-2
For details of changing a code refer to the section on code change on page 23. The default user codes are shown in the table.
Default Codes
User Number PIN
2 0202 3-last user Off
User Menu
Authority
Code-3
Users can be programmed with a number or options including authority level, area access and timed access.
When the authority option is selected the user authority menu is displayed.
User Options
User-nnnn nnnn=User number
User Name
Manager Press ? for list of user authorities Code Change-On On/Off LogOn/Set-On On/Off Schedule 1-Off On/Off (PX18/34 only) Schedule 2-Off On/Off (PX18/34 only) Group 1-Off On/Off Group 2-Off On/Off … Group 32-Off On/Off, the number of groups depends on the panel type
On/Off (PX18/34 only)Door 1-Off
Door 2-Off On/Off (PX18/34 only)
The available menu options are dependent on the programmed user authority.
User Auth Help
0=Off 1=Manager
2=Ordinary 3=Set/Uns 4=Set 5=Unset 6=Cleaner 7=Access 8=Reset 9=Duress
Refer to the user authority option table for full details of options available for each user type.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 26 -
The menu options available to each authority level are shown in the table.
Menu Option User Authority Level
Code Text Man Ord Set/
Uns
Set Unset Cleaner Access Reset Duress
01 Unset
3 3 3 7 3 3 7 7 3
02 Set
3 3 3 3 7 3 7 7 7
03 Reset
3 3 3 7 7 7 7 3 3
04 Test
3 3 7 7 7 7 7 7 7
05 Engineer 1 1 1 1
7 7 7 7 7
06 Code
3
2 2 2
7 7 7 7
2
07 User
3 7 7 7 7 7 7 7 7
10 Log-Full
3 7 7 7 7 7 7 7 7
11 Log-Cct
3 7 7 7 7 7 7 7 7
12 Log-User
3 7 7 7 7 7 7 7 7
13 Log-KP
3 7 7 7 7 7 7 7 7
14 Log-Date
3 7 7 7 7 7 7 7 7
15 Log-Alarm
3 7 7 7 7 7 7 7 7
16 A/Log-Full
3 7 7 7 7 7 7 7 7
17 A/Log-User
3 7 7 7 7 7 7 7 7
18 A/Log-Door
3 7 7 7 7 7 7 7 7
20 Time +/-75m 3 3
7 7 7 7 7 7 7
24 Holiday
3 7 7 7 7 7 7 7 7
25 Schedule
3 7 7 7 7 7 7 7 7
26 Set Group
3 7 7 7 7 7 7 7 7
30 Bypass 4 4
7 7 7 7 7 7 7
31 KP Off
3 7 7 7 7 7 7 7 7
32 Chime
3 3 7 7 7 7 7 7 7
40 Print Text
3 7 7 7 7 7 7 7 7
42 Print Hols.
3 7 7 7 7 7 7 7 7
50 Add User
3 7 7 7 7 7 7 7 7
51 Delete User
3 7 7 7 7 7 7 7 7
52 IdentifyUser
3 7 7 7 7 7 7 7 7
53 Door Unlock
3 7 7 7 7 7 7 7 7
54 Door Lockout
3 7 7 7 7 7 7 7 7
55 Door Text
3 7 7 7 7 7 7 7 7
71 Copy User
3 7 7 7 7 7 7 7 7
73 Copy A/User
3 7 7 7 7 7 7 7 7
86 Isolate Cct 5
7 7 7 7 7 7 7 7
87 Isolate Conc 5
7 7 7 7 7 7 7 7
89 Cct Status
3 7 7 7 7 7 7 7 7
Notes: Items marked 1-5 will only be available if programmed by the installation engineer.
User Authority Menu
Code Change
On/Off
Some user types are allowed by default to change their own code (refer to authority table). This feature can be disabled for any user without manager authority.
User Authority Menu
LogOn/Set
On/Off
If this option is on, a set prompt will be displayed in place of the normal log on menu, when the user logs on. If the user has only the set option available then either a list of the groups, which can be set, will be
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 27 -
displayed when logging on or, if there is only one set group available, setting will start when the user logs on.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 28 -
User Authority Menu
Schedule 1-2 (PX18/34)
On/Off
A user can be programmed with schedules 1 and/or 2 to control access times. The timer and holiday schedules may also be programmed.
User Authority Menu
Set Group 1-max
On/Off
If the Set Group option is on the user can be programmed any combination of set groups.
User Authority Menu
Door 1-2 (PX18/34)
On/Off
If access modules are fitted to the system then a user can be authorised for access through doors 1 and/or 2.
User Menu
Schedule (PX80/500)
Code-5
A user can be programmed with a schedule to control access times. Program 0 to allow 24hr access.
User Menu
Door Access (PX80/500)
Code-5
Each user can be programmed for any combination of the available doors.
User Options
User-nnnn nnnn=User number Enable-Off On/Off, this option must be on to view other options
Door 1-Off On/Off . . . Door 32-Off On/Off Challenged-Off On/Off
Door Options
Challenged
On/Off
If a user is programmed as challenged then the door release and open times will be automatically doubled for the user.
User Menu
Lockout (PX80/500)
Code-6
A user can be locked out of the system at any time. All user configuration is retained while a user is locked out.
User-nnnn The user number Lockout-Off On/Off
User Menu
Expiry Date (PX80/500)
Code-7
Expiry dates can now be programmed for all users (panel and access). This option is available even if no access module is fitted to the system.
Expiry Date
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 29 -
Off No expiry date is programmed, press enter to change
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 30 -
Expiry Date Enter DDMMYYYY Enter the day, month and year.
To delete an expiry date enter the day and month of 0000 and the current year.
Logs
The panel logs all events that occur in the system. All events stored in the event log are numbered in the range 0-65535. The event number is only used when printing the log. The event number will be the same even if the event is printed as part of a filtered log. The event number will only be reset if more than 65535 events have been recorded.
The event log may be displayed or printed in full or in filtered form. Printing will only be available if a printer interface is fitted to the system. When a log option is selected the display or print choice menu will be displayed.
1=Display 2=Print
Press 1 to display or 2 to print the selected log items. The print option will only be available if a printer is fitted to the system
Logs
Event Log Messages
Log messages are constructed using the event time, the event type and the additional information specified by the event type. Each event is time stamped to the nearest 2 seconds. If a text description has been programmed it will be used in the printed log. When the log is displayed abbreviations are used.
The displayed log format is:
PIR in Hall the circuit description Bypassed the event type
The event time and circuit number may be displayed in place of the normal top line information by pressing the ? button.
12:00:00 Cct 1 the event time and additional data Bypassed the event type
Press the ? button again to display the user number.
U xxxx Cct 1 the event time and additional data Bypassed the event type
You can set the display mode you prefer or use the ? button to switch between display modes as you scroll through the logged events. You can use the é and ê buttons to step through the events.
In the table below all messages logged by the panel are shown. Some message types are stored in both the alarm and event logs and some are stored in the event log only.
Logs
Printed Log
If the log is printed then the log index number, text descriptors and the date will be printed for each event.
00001 Sat 02 Jan 00:00:02 User 2 (Mr Smith) Logged On on KP 0
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 31 -
Logs
Log-Full
Code-10
All logged events may be displayed or printed.
Logs
Log-Cct
Code-11
All logged events for a particular circuit number may be displayed or printed.
Logs
Log-User
Code-12
All logged events for a particular user may be displayed or printed.
Logs
Log-KP
Code-13
All logged events for a particular keypad may be displayed or printed.
Logs
Code-14
All logged events for a particular date may be displayed or printed.
Logs
Log-Alarm
Code-15
All logged alarm events may be displayed or printed.
Access Log
A/Log-Full
Code-16
The access log capacity of the system is 1000 events. This log contains the most recent 1000 events for all doors in chronological order. All log options are configurable for each door. The Access log options are only accessible to users with manager authority.
The full access log may be displayed or printed.
Access Log
A/Log-User
Code-17
Events for a single access user may be displayed or printed. Select option 17, then enter the user number.
Access Log
A/Log-Door
Code-18
Events for a single door may be displayed or printed. Select option 18, then enter the door number.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 32 -
Logs
Log Messages
Alarm & Event Log messages
Log Text Additional Data Display Text Event Description
Alarm Circuit nnn Cctnnn A Circuit alarm Anti mask Circuit nnn Cctnnn A Circuit program with the anti-
mask option has alarmed
Bat.Monitor Fail NONE (see note) NONE Battery voltage is low or not
present during a battery test
Battery Low NONE (see note) NONE The battery has reached the low
volts threshold (after a mains fail)
Comm Fail NONE NONE Control panel comm fail input
active.
Entry Alarm Area n An The area is not unset before the
end of the entry warning period Fire Circuit nnn Cctnnn A fire type circuit alarm Panel Tamper NONE NONE Panel case or off the
wall tamper Personal Attack Circuit nnn Cctnnn A PA type circuit alarm Rmt.Auth Fail NONE NONE Repeated attempt to log on by a
remote host Sndr Tamper NONE NONE Panel sounder tamper Tamper n n Concentrator Tamper Tamper Circuit nnn Cctnnn A circuit tamper Tamper Keypad n KPn A keypad tamper Tamper SM n SMn A serial module tamper Tamper OM n OMn An output module tamper Tamper Door n Doorn An access module tamper
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 33 -
Event log only messages
Log Text Additional Data Display Text Event Description
230v Fault NONE (see note) NONE Mains supply failed 230v OK NONE (see note) NONE Mains supply restored Active Circuit Circuit nnn Cctnnn User selected active circuit test Alarm (master shunt) Circuit nnn Cctnnn Master shunt type circuit alarms Alarm Abort User nn, Keypad m Usnn, KPm Alarm abort signal transmitted. Auto Check Fail Circuit nnn Cctnnn A Circuit has failed to activate
during the auto check period. Auto Check OK NONE NONE Circuit Auto Check was OK Bypass User nn, Circuit mmm Usnn Cctmmm Circuit bypassed Cannot set User nn, Area m Usnn, Am User was not able to set an area Cct Tested Circuit nnn Cctnnn Circuit responded in walk test Changed Code User nn, Keypad m Usnn, KPm User changes own code Changed Code User nn, User mm Usnn, Us mm Manager or GSR user changes
code for another user Changed Time User nn, Keypad m Usnn, KPm Time modified, old time and new
time are logged Check Fuse n N Panel fuse number Check Fuse Conc n Conc n Concentrator fuse Check Fuse OPM n OPM n Output module fuse Check Fuse Door n Door n Access module fuse Clear Circuit nnn Cctnnn Master shunt type circuit clears Code Clash User nn, User mm Usnn, Us mm User has chosen a new code
which is the same as another
user Comm Acknowledge n N Central station acknowledge
alarm report Comm Fail n N Central station fails to
acknowledges alarm report Comm Test User nn, Keypad m Usnn, KPm User or the panel tested the
communicator(s) Duress Alarm User nn, Keypad m Usnn, KPm User enters a duress code Engineer Reset Circuit nnn Cctnnn Engineer reset type circuit
alarms Entry Started Circuit nnn Cctnnn Entry circuit opens Failed Auto Set User nn, Area m Usnn, Am Event programmer failed to auto
set due to circuits in alarm Fault Circuit nnn Cctnnn A Circuit short circuit when unset
or in alarm when trying to set Fault Keypad n KPn Failed poll when unset Fault Conc nn Conc nn Failed poll when unset Fault OPM nn OPM nn Failed poll when unset Fault SM n SM n Failed poll when unset Fault Door nn Door nn Failed poll when unset First code User nn, Keypad m Usnn, KPm User entered code on Dual code
keypad Head Count Number Number of activations of all
circuits programmed with the
head count option while the panel
was unset. Isolate User nn, Circuit mmm Usnn Cctmmm Circuit isolated by user Isolate User nn, Conc m Usnn, m Concentrator isolated by user Key Set Req. Circuit nnn Cctnnn Key type circuit alarms Key Unset Req. Circuit nnn Cctnnn Key type circuit clears
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 34 -
Event log only messages
Log Text Additional Data Display Text Event Description
Knock Circuit nnn Cctnnn Circuit first knock Line Block NONE NONE SmartDial has reported a line
blocked condition Line Fault
1 - 50 volts not present 2 - Line block test failure 3 - No acknowledge from central station 4 - Main PCB LF input 5- SmartDial Fault
NONE Communicator has reported a
line fault
Lockout Keypad n KPn Incorrect code attempt limit
reached on the keypad Logged Off User nn, Keypad m Usnn, KPm User logged off keypad Logged On User nn, Keypad m Usnn, KPm User logged on keypad Managed Rst Keypad m KPm Managed reset code entered Marginal Circuit nnn Cctnnn A Circuit is marginal Mult. Alarm Circuit nnn Cctnnn Circuit has alarmed up to the
multiple alarm limit Normal User nn, Conc m Usnn, m Isolate removed from a
concentrator Normal User nn, Circuit mmm Usnn Cctmmm Bypass or isolate removed from a
circuit PC Access User 00 Usnn A GSR user has logged on
remotely. Power Fail NONE (see note) NONE Supply voltage has
fallen to the power fail threshold Pre-Warning Circuit nnn Cctnnn A circuit has been alarmed during
the entry period Reprogrammed User nn, Keypad m Usnn, KPm A configuration option(s) has
been changed Reset Circuit nnn Cctnnn An area has been reset Reset User nn, Area m Usnn, Us nn An area has been reset Clear Circuit nnn Cctnnn A Circuit alarm has cleared. Restored Code(s) User nn, Keypad m Usnn, KPm All codes have been restored to
default Set User nn, Area m Usnn Am Area has been set by a user Shunt Off Circuit nnn Cctnnn A master shunt circuit or the
event programmer schedule has
removed the shunt from a circuit Shunt On Circuit nnn Cctnnn A master shunt circuit or the
event programmer schedule has
shunted a circuit Soak Alarm Circuit nnn Cctnnn A circuit on soak test has
alarmed Soak Failed Circuit nnn Cctnnn At the end of the soak period any
circuit which has alarmed is
logged as failed Soak Off Circuit nnn Cctnnn A circuit has been taken off soak Soak On Circuit nnn Cctnnn A circuit has been put on soak Software Error N N A software error has been logged Temp Bypass Circuit nnn Cctnnn A circuit has been temporarily
(until clear) bypassed TX On N N TX channel N on TX Off N N TX channel N off Unset User nn, Area m Usnn Am A user has unset the area
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 35 -
Event log only messages
Log Text Additional Data Display Text Event Description
Verify Alm Area n An A verified alarm has occurred Watchdog NONE NONE Software watchdog active
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 36 -
Note: If the software versions supports auxiliary PSUs then the following messages will be logged with a number:
Battery Low
230v Fault
230v OK
Power Fail
Bat.Monitor Fail
The number represents the PSU device:
Logged Number Device
0 Control Panel 1-max concs Concentrator number Max concs-max concs + max access modules
Access module number
Access log only messages
Log Text Additional Data Display Text Event Description
Access User nn, Door m Usnn, Doorm User accessed door m Denied User nn, Door m Usnn, Doorm User denied access door m Set Req. User nn, Door m Usnn, Doorm User request to set from door m Unset Req. User nn, Door m Usnn, Doorm User request to unset from door
m Exit User nn, Door m Usnn, Doorm User exit by door m Door Open Door m Doorm Door held open Forced Door m Doorm Door forced open Unlock Door m Doorm Door unlocked Lock Door m Doorm Door lock Pending Door m Doorm Schedule unlock pending RTE Door m Doorm Door RTE button active
Time
Code-20
The clock can only be set by the engineer. Some users have the authority to change the time by up to 75 minutes from the time set by the engineer if the user clock edit option is programmed.
Time 12:00 To change, start entering the new time
Time Enter HH:MM Enter the new time
The old and new times will be recorded in the event log.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 37 -
Holiday
Code-24
Feature PX18 PX34 PX80 PX500
Max. Holidays 0 14 14 14
This option is used in conjunction with the programmable schedules. To program a holiday, select the holiday option from the main menu followed by the holiday number. The holiday menu will then be displayed.
Holiday Options
Holiday-x x=holiday number Start-DD:MM DD:MM
End-DD:MM DD:MM Set Group-1 1 – Max Set Groups
Note: The holiday date format is day and month only. No year is entered therefore the entered date will remain programmed as a holiday for all subsequent years, or until it is removed from the holiday schedule. It is not possible to program a holiday period that starts in December and ends in January. To achieve this 2 holiday periods must be programmed.
Holiday Menu
Start
DD:MM
Enter the holiday start day and month. To disable a holiday enter a date of 00:00. The date entered must be before the programmed end date.
Holiday Menu
End
DD:MM
Enter the holiday end day and month. To disable a holiday enter a date of 00:00. The date entered must be after the programmed start date.
Holiday Menu
Set Group (Px80/500)
1 – Max Set Groups
A holiday can be programmed for a single set-group
Holiday Menu
Set Group 1-8 (Px34)
On/Off
If the Set Group option is on the holiday can be programmed any combination of set groups.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 38 -
Schedule (PX18 & 34)
Code-25
Feature PX18 PX34
Max. Schedules 4 8
A schedule can be used to:
1. Auto set and unset parts of the system
2. Control outputs
3. Enable/disable keypads
4. Enable/disable user access
To program a schedule, select the schedule option from the main menu followed by the schedule number. The schedule menu will then be displayed.
Schedule Options
Schedule-x x=Schedule number Start Time-00:00 HH:MM
Stop Time-00:00 HH:MM Mon-Off On/Off Tue-Off On/Off . . . Sun-Off On/Off Holiday-Off On/Off
Schedule Menu
Start Time
HH:MM
To disable a schedule the start and stop times should be set to 00:00.
Schedule Menu
Stop Time
HH:MM
To disable a schedule the start and stop times should be set to 00:00.
Schedule Menu
On/Off
Each schedule can be configured for any combination of days, if the start or stop times are non zero. The programmed schedule function will not operate on days that are programmed as off.
Schedule Menu
Holiday
On/Off
If the holiday option is on, then the schedule operation will be suspended on dates that are programmed as holidays.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 39 -
Schedule (PX80 & 500)
Code-25
Feature PX80 PX500
Max. Schedules 16 32
A schedule can be used to:
1. Auto set and unset parts of the system
2. Control outputs
3. Enable/disable keypads
4. Enable/disable user access To program a schedule, select the schedule option from the main menu followed by the schedule
number. The day menu will then be displayed.
Schedule Options
1=Mon 2=Tue
3=Wed 4=Thu 5=Fri 6=Sat 7=Sun 8=Hol
Select the day or holiday (Hol) to program the schedule times:
Schedule Options
Schedule-nn Day nn=Schedule number, Day= selected day or holiday Start 1-00:00 HH:MM
Stop 1-00:00 HH:MM Start 2-00:00 HH:MM Stop 2-00:00 HH:MM
Two sets of times may be programmed for each schedule day. This allows, for example, 2 access periods to be configured for a user or 2 auto set/unset times.
Set Group
Code-26
A descriptor of up to 10 characters may be entered for each set group. Refer to the user name section for details of how to change a descriptor.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 40 -
Bypass
Code-30
The bypass option will only be available if a circuit(s) has been programmed as bypassable by the installation engineer.
The bypass circuit option allows the user to bypass a circuit that is in a fault condition. When bypassed the alarm condition of a circuit is ignored.
Circuit Number-x
To bypass a circuit select the bypass option from the main menu, followed by the circuit number.
Circuit -x Normal The current state will be displayed
When a circuit is bypassed it is ignored until the bypass is automatically removed when the circuit is next unset or until a user removes the bypass. All bypass actions are stored in the event log.
A bypass limit will have been programmed by the installation engineer to limit the number of circuits that can be bypassed at any one time. The system will display an error message if you try to exceed this limit.
Keypad Off
Code-31
A keypad can be disabled by an authorised user if required. Disabling a keypad will render all buttons on the keypad inoperative, however the keypad display will continue to operate normally.
To disable a keypad, enter the keypad number.
Keypad-x On Press 0 to turn off or 1 to turn on.
12:00 Mon 27 Sep
Out of Service
A keypad that is turned off will show the time/date and out of service message.
Not Available: Keypad Busy
You cannot turn off a keypad which is being used. If this is attempted a warning message will be displayed.
The installation engineer may also have programmed the system to turn off a keypad(s) at various times of day. This allows, for example, a keypad in a public area to be turned off while the area is unset.
Chime
Code-32
Certain circuit types can be selected as chime circuits when unset. To select the chime function for a circuit, enter the circuit number.
Circuit -x The circuit descriptor will be displayed. Front Door Press any button to display the current chime status of the circuit.
Circuit -x Chime-Off Press 0 to turn off or 1 to turn on.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 41 -
Printing
Print Text
Code-40
The print text option will print all text descriptors for users, circuits, set groups, and the company name.
Printing
Print Hols.
Code-42
The print holiday option will print all holiday periods.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 42 -
Access Features
The number of Access Modules that can be connected depends on the panel variant:
Feature PX18 PX34 PX80 PX500
Access Modules 2 2 16 32
The table shows the access features across the panel range.
Feature PX18 PX34 PX80 PX500
Doors 2 2 16 32 Panel Users 20 40 100 200 Access Users 20 40 1000 1000 User expiry dates
7 7 3 3
Challenged user option
7 7 3 3
User lock out from keypad
7 7 3 3
Door lock/unlock from keypad
3 3 3 3
Programmable unlock time
3 3 3 3
Programmable Aux. relay time
3 3 3 3
Anti pass back
3 3 3 3
Access log events 1000 1000 1000 1000 Access log real time print
3 3 3 3
Set & unset
3 3 3 3
Note: The panel users must be the first users in the system. For example on the PX 500 users 2-200 may be access or panel users, users 201-1000 can only be access users and user 1 is always the engineer.
The PX access control system can be configured through a security system keypad or a PC running GuardStation™ Access. Guardall PX proximity tokens may only be introduced to the system through a PX keypad with an integrated proximity reader.
The Access Module door input may be programmed as a circuit. Refer to the Input Map option for details.
Access System
Security System Integration
1. The door contact may be programmed as a security panel entry/exit circuit or be given any other circuit response.
2. An access system user can be programmed as a security system user.
3. The door may not be unlocked while the access module area is set. The access module area is the area that the door circuit is programmed for.
4. All doors may be programmed to open if a fire alarm is reported from the security system.
5. The door area may be set and unset from a Proximity reader.
Outputs on the security system may be programmed to follow the state of a door circuit.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 43 -
Add User
Code-50
When the Add User option is selected, the first free user number will be selected by the system and the normal user programming menu will be displayed.
User xxxx Present Card/Fob Present the card or fob for the new user
The user authority is automatically set to Access for all doors and the user text descriptor will be defaulted.
Delete User
Code-51
When the Delete User option is selected, a range must be entered:
Delete User Frst ____ Lst ____ Enter the first and last users number in the range 2-max user
Identify User
Code-52
This option allows a user to be identified by presenting the card/fob.
Present Card/Fob Present the token or press 7to exit.
If the card/fob is not used then a message will be displayed.
Code Not Used Present another token or press 7to exit.
If the token is used then a message will be displayed.
User X The user number “User Descriptor”
Further card/fobs may be presented and identified at any stage.
Door Unlock
Code-53
Enter the door number:
Door Lock Menu Options
Door-nn Door Unlock-Off On/Off
A door can be manually unlocked from a keypad. The door unlock off command is required to lock the door after indefinite unlock. If the door is locked it can still be opened by presenting a valid user card.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 44 -
Door Lockout
Code-54
Enter the door number:
Door Lock Menu Options
Door-nn Door Lockout-Off On/Off
The locked out door will remain locked and will refuse all access attempts until the lockout is removed. The door lockout can only be removed through this programming option. The door lockout will over-ride any user/door schedule permissions or otherwise immediately, and for the applied duration. Upon removal the door will be returned to its previous state (if that state still applies). Proximity reader LED’s will show the door as locked out for the applied duration.
Door Text
Code-55
A descriptor of up to 10 characters may be entered for each door. Refer to the user name section for details of how to change a descriptor.
Isolate Cct
Code-86
The isolate circuit option will only be available if programmed by the installation engineer. The isolate circuit operation enables a circuit to be isolated in case of a fault. When isolated the alarm
and tamper condition of a circuit are ignored.
Circuit Number-x Enter the circuit number
Circuit -x Normal The current state will be displayed
When a circuit is isolated it is ignored until the isolate is removed. Isolate can only be removed if the circuit is in a clear condition.
Isolate Conc
Code-87
The isolate concentrator option will only be available if programmed by the installation engineer. This option enables a concentrator tamper to be isolated if a fault occurs.
Concentrator Number-x Enter the concentrator number
Isol Conc-x Off The current state will be displayed
When a concentrator is isolated it is ignored until the isolate is removed. Isolating a concentrator does not isolate circuits connected to the concentrator.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 45 -
Cct Status
Code-89
The circuits that are on soak, bypassed or isolated can be displayed.
Cct Status Normal
The display will scroll all circuits that are bypassed, isolated or shunted.
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 46 -
System Details
Number of Areas
Number of keypads
Number of Circuits
Number of Users
Service Number
Contract Number
Keypads
Number Location
1
2
3
4
5
6
7
8
Set Groups
AreasNumber Description
1 2 3 4 5 6 7 8
1
2
3
4
5
6
7
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 47 -
AreasNumber Description
1 2 3 4 5 6 7 8
8
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 48 -
Circuits
Number Description Location
Cct 1
Cct 2
Cct 3
Cct 4
Cct 5
Cct 6
Cct 7
Cct 8
Cct 9
Cct 10
Cct 11
Cct 12
Cct 13
Cct 14
Cct 15
Cct 16
Cct 17
Cct 18
Cct 19
Cct 20
Cct 21
Cct 22
Cct 23
Cct 24
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 49 -
Number Description Location
Cct 25
Cct 26
Cct 27
Cct 28
Cct 29
Cct 30
Cct 31
Cct 32
Cct 33
Cct 34
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 50 -
Users
Areas or Set GroupsNumber Name Authority Level
1 2 3 4 5 6 7 8
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Intelligent Security & Fire Ltd
PX Control Panel User Manual – Issue C
- 51 -
Areas or Set GroupsNumber Name Authority Level
1 2 3 4 5 6 7 8
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Intelligent Security & Fire Ltd
Guardall Limited
Lochend Industrial Estate
Newbridge
Edinburgh EH28 8PL
Tel: 0131-333-2900
FAX: 0131-333-4919
Technical Hotline: 0131-333-3802
Part Number: 320680-0C
Intelligent Security & Fire Ltd
Loading...