Guardall DTX 15, DTX 18 Installation Instructions Manual

Installation Instructions
Part No. 320902-0E
DTX 15 / 18
3
5
7
1
2
4
8
6
Diagram 1 - Description
1. Coin slot
2. Off the wall tamper (using this mounting hole provides off the wall tamper)
3. Detector mounting holes
4. Cable entry knock-outs
5. Mirror adjustment and fi xing screw
6. Pyro Detector (Do not touch)
7. Microwave range control
8. Cover screw (Loosen only - do not remove)
Guardall Limited
Lochend Industrial Estate
Newbridge, Edinburgh EH28 8PL
Technical Hotline: 0131- 333-3802
Website: www.guardall.com
Volumetric Plan View 15m / 18m
Volumetric Side View 15m / 18m
7.5m/9m
0m
7.5m/9m
2.3m
Diagram 3 - Coverage Patterns
0 4m/4.5m 7.5m/9m 12m/13.5m 15m/18m
0 4m/4.5m 7.5m/9m 12m/13.5m 15m/18m
Voltage: 12 V (9 V to 16 V dc) Current: Quiescent – 17 mA @ 12V
Max – 22 mA @12V (All LED’s ON)
Alarm, Aux & Tamper:
Normally closed (NC). Rated at 24 V dc, 50mA
Test Input: Positive supply to enable LEDs and control
Remote Self Test
Control Input: Positive supply for system Set. Otherwise
Unset
Microwave range: 50% to 100% of range via potentiometer
1. Technical Specifi cation
See datasheet for full information
Use in EN50131 Complaint Systems:
DTX 18 meets the requirements of TS50131-2-4:2004, Grade 3, Class II with SW4 and SW9 ON and SW3 OFF. DTX 15 meets the requirements of TS50131-2-4:2004, Grade 2, Class II and is suitable for use on PD6662 Grade 3 systems with SW4 ON and SW3 OFF.
Diagram 2 - Terminal block
10 9 8 7 6 5 4 3 2 1
NC Aux
Ctrl
12 V
Test
+ -
NC Alarm
NC
Tamper
Red Green Yellow
SW1 Test
ab
Fault
Other
Fault
Other
OFF Low
-
-
-
ON x
xHigh
x =don’t care
-
-
Coverage shown applies with unit mounted 2.3m high, SW2 OFF, micro­wave at max and mirror at factory set position. Changing these may affect approval compliance.
Declaration of Conformity :
Hereby Guardall Ltd, declares that DTX18/100 and DTX15/100 are approved for use in UK, Italy & Eire and that DTX18/2500, DTX15/2500, are approved for use in Portugal and all are in compliance with the essential requirements and other relevant provisions of EU Directive 1999/5/EC.
Intended use: Within a building as an intruder detection device. Safety Information: The power feed must be fused at 5A or less.
2. Installation Location
The recommended mounting height of the detector is 2.3m. Ensure the detector’s fi eld of view is not obscured. Please refer to Installation Guidance Notes available on our website or call the Technical Hotline for further information.
3. Walk testing
Select switch 1 to ON. The yellow LED displays PIR activity. The PIR coverage is adjusted by loosening the two mirror locking screws, moving the mirror up or down, then re-tighten the locking screws. Position B=18m and C=12m.
The green LED displays microwave activity. Range is adjusted via the microwave range control (7 in Diagram 1). The microwave should be set to the minimum necessary to give the required coverage. Note that coverage under the unit may also change.
The red LED displays unit alarms. Walk test the area checking that alarms are indicated at the control
panel. Check tamper operation if wired.
4. Operating Feature Selection
SW1: LED enable - See LED indications section SW2: Pulse Count
In harsh environments select switch 2 ON (pulse count).
SW3: Microwave Day Disable
OFF - the microwave will be permanently active. ON - microwave is disabled when system Unset.
SW4: Anti-mask / Fault Output
SW4 Faults Mask Signalled On
ON Aux + LED (if enabled) Alarm + Aux + LED (if enabled) OFF LED Aux + LED
To reset a mask: Remove the mask, wait 30 secs, generate an alarm. If Switch 3 (UW day disable) is ON the Anti-mask is disabled.
SW5, SW6 & SW7: Enable built-in EOL resistors for Guardall panels
SW5 SW6 SW7 EOL Connection
No EOL OFF OFF OFF Terminal 3 to 10 Alarm / Tamp ON ON OFF Terminal 3 to 10 (*1) Alarm / Tamp
/ Aux
ON ON ON Terminal 8 to 10 (*2) (*3)
(*1) To monitor Aux output on a separate zone fi t external EOL resistors. (*2) Only Px/Qx V3.2 or above, with Fault EOL option enabled. (*3) Note: add a link between terminal 3 and 7
SW9: Anti-Mask Sensitivity In harsh environments select switch 9 OFF.
SW10: Anti-Stealth
SW10 ON - Enhances detection for high security applications. Please refer to Installation Guidance Notes available on website or call the Technical Hotline for further information.
5. Remote Self Test
With switch 4 ON, a self test is generated when the TEST Input is taken high to low. The alarm output will signal a successful remote self test. A failure will generate a fault condition. This is only reset by a successful remote self test.
6. Alarm Memory
* System Set Should an alarm occur the alarm will be memorised.
* System Unset and SW1 OFF TEST Input Low : the red LED will remain ON (if an alarm is memorised). TEST Input High: the LEDs display normally without losing alarm memory.
Memory reset occurs the next time the system is set.
7. LED Mode Setting System Set: None System Unset:
With SW4 OFF, the following table applies. With SW4 ON, SW1 OFF and TEST low , the following table applies except No Faults are displayed.
8. LED Indications
Red LED Indications: a) Latched Alarm : ON constant.
Anti-Mask Fault: With latched alarm: Flicker...ON..Flicker..ON..etc. No latched alarm:Flicker..OFF..Flicker..OFF..etc Low Voltage : One Flash every second.
b) Low Voltage : One Flash every second. Unit Alarm : ON for 3 secs. Anti-Mask Fault : Flicker..OFF...Flicker..OFF..etc.
Green LED Indications:
Microwave Alarm : ON for 3 secs. Microwave detection : One Flash. Microwave Masked : 2.5 Flashes every second. Microwave Fault : ON Dull (while Faulty).
Yellow LED Indications:
PIR Alarm : ON for 3 secs. PIR Alarm event : One Flash. (pulse count only) PIR Masked : 2.5 Flashes every second. PIR Fault : ON Dull while Faulty.
9. Warranty
All Guardall products are warranted against defects in workmanship in materials (details available on request). In the interests of improving quality and design, Guardall reserve the right to amend specifi cations without giving prior notice. Faulty product should be returned to your supplier.
Note: Guardall recommend that the detector is regularly walk tested back to the control panel and that installers advise their customers to do this.
Enabled Disabled
ON OFF
Enabled Disabled
Faults on Aux AM on Aux
Connected OFF
Connected OFF
Connected OFF
- -
High Sensitivity Standard
Enabled Disabled
Diagram 4 : Factory Defaults
No. Function
1 LED Enable 2 Pulse Count 3 UW Day disable 4 AM / Faults O/P 5 *EOL 1 6 *EOL 2 7 *EOL 3 8 Not used 9 Anti-Mask Sensitivity
10 Anti-Stealth * See below
OFF
ON
1 2 3 4 5
6 7 8 9 10