Guangzhou J&J Sanitary Ware SPA-8218 Operating Instruction

HOT TUB
Model SPA-8218
OPERATING INSTRUCTION
1
I
Fig.1
Control Panel
MIN
Frequency up- searching / Minute
On-off/Setting confirm
HOUR
Frequency down- searching/ Hour
Radio or DVD/TV Switch/ On-off
+
Volume up/ Set switch
Blower On-off
/℉ or ℃ Switch
-
Volume down/ Open
Spa Light On-off
MEM
Radio channel Memory/ Lock
Surfing pump 1 On-off
SET
Radio channel read / Close
Surfing pump2 On-off
Lasting Circulation Cleaning On-off
Surfing pump3 +circulation pump On-off/Set
Circulation Cleaning Time
Heating On-off
/ Set Pre-heating
Set Temperature
Note
.The functions listed with blue letters only works on the condition of on-off
IIFunction Summary
1、Max. with 6 KW heating system, set pre-heating, set and display temperature
2
2、With 3 surfing pumps,1 circulation pump, 1 view pump, and 1 blower.
3、Ozone, Spa lights.
4、CD audio-input / Display of radio frequency and preserve 10 channels
5、Volume display and 87 frequency adjustment
6、Circulation cleaning and time set of circulation cleaning
7、24 hours display and time set
8、Memory preserve once power off
9、Fahrenheit & Celsius degree switch
10、Antifreezing functions
11Keys with backlight
12Lock setting
13Three-phase or single-phase, available of 110-120VAC or 220-240VAC 14Choice with “CD” function, offering a AC supply for circumscribing DVD or TV 15Choice with power control 16Choice with galvanoscope device 17、In the status “Power off " ,the spa only can be operated the function for presetting
.
18、When start the circulation pump, the massage pump will start at the same time, and it will stop automatically after working 30seconds. but the heater will not start. 19、Configuration for 3kw heater: when the heater start, and switch on three pcs massage pumps, the heater will stop automatically. but if you switch off one pc from the three pcs massage pumps, the heater will resume working automatically. 20、Configuration for 6kw heater: when the heater start, and switch on two pcs massage pumps, the heater will stop automatically. but if you switch off one pc from the three pcs massage pumps, the heater will resume working automatically. 21、Massage pump will stop automatically after after working 25minutes, if you want it to go on to work, you need to start it again. 22、All circuit boards can adapt 220V and 380V which are both compatible with dual-use
IIIOperation
Fig.3Temperature Normal Display Fig.4Senor on/short circuit display
1When you first start the spa, the backlight will be dimmed and the LCD will show the current time and
temperature. If there is a problem with the circuit board the controller will display the code “E1”. When the radio frequency is displayed as “---” it indicates that the spa is in “power off” model, and pre-heating and circulation cleaning function is off.
2Lock memory Mode(optional function)
The memory lock will start work by pressing
MEM
” key
in the status of “power off”when the spa
3
has not been adjusted for a period of 30 minutes. When the memory locked key is pressed TWICE
MEM
the spa will become unlocked and the word
LOCKED”will disappear.
3Adjusting Time
In the status “Power off” and the pre-heating and circulation cleaning are not starting. Pressing
MIN
”or“
HOUR
adjust time . The Minute and Hour display flash at this time. It will add 1 hour when
pressing
HOUR
each time and the hours can be adjusted continually when pressing the
HOUR
without stopping. The hour adjustment range is 0-23.
In the status of time setting It will add 1 minute when pressing
MIN
each time and the minutes
could be added continually when pressing the
MIN
without stopping. The minute adjustment range is
0~59
The system will quit the time-setting status automatically after 6 seconds without pressing any buttons
4
Set pre- circulation-cleaning
In the pre-set mode circulation will be automatic once per day. The display will show clearly whether
circulation is in action or not. See following Fig 5-6
AM
AM
Fig.5Circulation-cleaning off Fig.6Circulation-cleaning on
When setting the Circulation-cleaning the display must be in the “Power off” status and the LCD display “---”
1
Press“ to enter Circulation-cleaning setting mode and the LCD shows and flashes ”,and
then the circulation works on. Press “ ” again to off the circulation cleaning, and the “ ” will
disappear.
2)、Press“ ”(minutes)and“ ”(hours
to adjust the time.
It will add 1 minute when pressing
MIN
each time and the minutes could be added continually.
The adjustment range is 0~59.
It will add 1 hour when pressing
HOUR
each time and the hours could be added continually. The
adjustment range is
0-23.
After setting the circulation cleaning pre-set timing, go to next step
.
4
1)
circulation
2)
Set start of circulation
3)
Set lasting time for circulation
4)
Finished
3)、Press“ to set the circulation times; it will show the minimum(5 minutes) on the LCD and this time will
not flash. It will add 5 minutes by pressing each time. It will add 1 hour by pressing“ ”each
time。The maximum working time is 19hours and 55 minutes. When you have completed this procedure continue
to the next setting.
4)
If all settings have been correctly, set Press ” for confirmation , the system will quit this mode
automatically(press key “ ” to clear settings and exit).
***Notice***
1 All the setting of Circulation-cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation
cleaning.
5Set preheating (if required)
Only one pre-heating setting is allowed each day if required.The LCD can show clearly in the following
figures whether pre-heating settings are set or not
See following Fig.7-8
5
Loading...