1. I、Illustration to buttons
Fig.1:Control Panel
”Frequency up- searching / Minute
“ ” On-off/Setting confirm
” Frequency down- searching/ Hour
“ ” Radio or DVD/TV Switch/ On-off
“ ” Blower On-off/℉ or ℃ Switch
” Radio channel Memory/ Lock
” Radio channel read / Close
“ ” Lasting Circulation Cleaning On-off
“ ”Surfing pump3 +circulation pump On-off/Set
Circulation Cleaning Time
“ ” Heating On-off / Set Pre-heating
Note:
.The functions listed with blue letters only works on the condition of on-off
II、Function Summary
1、Max. with 6 KW heating system, set pre-heating, set and display temperature
2、With 3 surfing pumps,1 circulation pump, 1 view pump, and 1 blower.
3、Ozone, Spa lights.
![](/html/68/68de/68dee58eda787ab0f972b0c77ac2634e3eb1c37185528a2f2b347626de7f5dd8/bg3.png)
4、CD audio-input / Display of radio frequency and preserve 10 channels
5、Volume display and 87 frequency adjustment
6、Circulation cleaning and time set of circulation cleaning
7、24 hours display and time set
8、Memory preserve once power off
9、Fahrenheit & Celsius degree switch
10、Antifreezing functions
11、Keys with backlight
12、Lock setting
13、Three-phase or single-phase, available of 110-120VAC or 220-240VAC
14、Choice with “CD” function, offering a AC supply for circumscribing DVD or TV
15、Choice with power control
16、Choice with galvanoscope device
III、Operation
Fig.3:Temperature Normal Display Fig.4:Senor on/short circuit display
1、When you first start the spa, the backlight will be dimmed and the LCD will show the current time and
temperature. If there is a problem with the circuit board the controller will display the code “E1”. When
the radio frequency is displayed as “---” it indicates that the spa is in “power off” model, and
pre-heating and circulation cleaning function is off.
2、Lock memory Mode(optional function):
The memory lock will start work by pressing “
” key in the status of “power off”when the
spa has not been adjusted for a period of 30 minutes. When the memory locked key is pressed TWICE
“
” the spa will become unlocked and the word “LOCKED”will disappear.
3、Adjusting Time:
In the status “Power off” and the pre-heating and circulation cleaning are not starting. Pressing
“
” adjust time . The Minute and Hour display flash at this time. It will add 1 hour when
pressing “
” each time and the hours can be adjusted continually when pressing the “
”
without stopping. The hour adjustment range is 0-23.
In the status of time setting It will add 1 minute when pressing “
” each time and the minutes
could be added continually when pressing the “
” without stopping. The minute adjustment range is
![](/html/68/68de/68dee58eda787ab0f972b0c77ac2634e3eb1c37185528a2f2b347626de7f5dd8/bg4.png)
0~59
The system will quit the time-setting status automatically after 6 seconds without pressing any buttons
4、Set pre- circulation-cleaning:
In the pre-set mode circulation will be automatic once per day. The display will show clearly whether
circulation is in action or not. See following Fig 5-6:
Fig.5:Circulation-cleaning off Fig.6:Circulation-cleaning on
When setting the Circulation-cleaning the display must be in the “Power off” status and the LCD display “---”
1) 、Press“ ” to enter Circulation-cleaning setting mode and the LCD shows and flashes “ ”,and
then the circulation works on. Press “ ” again to off the circulation cleaning, and the “ ” will
disappear.
2)、Press“ ”( minutes)and“ ”( hours) to adjust the time.
It will add 1 minute when pressing “
” each time and the minutes could be added continually.
The adjustment range is 0~59.
It will add 1 hour when pressing “
” each time and the hours could be added continually. The
adjustment range is 0-23.
After setting the circulation cleaning pre-set timing, go to next step.
![](/html/68/68de/68dee58eda787ab0f972b0c77ac2634e3eb1c37185528a2f2b347626de7f5dd8/bg5.png)
1) circulation
2)
Set start of circulation
3) Set lasting time for circulation
4)
Finished
3)、Press“ ” to set the circulation times; it will show the minimum(5 minutes) on the LCD and this time will
not flash. It will add 5 minutes by pressing “ ” each time. It will add 1 hour by pressing“ ”each time。
The maximum working time is 19hours and 55 minutes. When you have completed this procedure continue to the
next setting.
4)、If all settings have been correctly, set Press “ ” for confirmation , the system will quit this mode
automatically(press key “ ” to clear settings and exit).
***Notice***
1 All the setting of Circulation-cleaning must be set on Power OFF status
2 Circulation PUMP and OZONE are not working while setting the circulation
cleaning.
5、Set preheating (if required):
Only one pre-heating setting is allowed each day if required.The LCD can show clearly in the following
figures whether pre-heating settings are set or not
See following Fig.7-8: