80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz. Input AC Current Waveform (ITHD = 7.19%, 50% Load)
I
PF
RMS
A
1.54 0.98 10.20% 20%
3.63 0.99 7.19% 50%
7.37 1.00 5.08% 100%
900.00
800.00
700.00
600.00
500.00
400.00
300.00
Power (Watts)
200.00
100.00
0.00
2827
GUANGDONG SOHOO TECHNOLOGY CO., LTD.
GM-700
N/A
2011
ATX12V
10/20/2011
Input Voltage
Input Current
Input Frequency
Rated Output Power
I
(%) Load
THD
(%)
Input and Output Power
Input Watts
Loading (% of Rated Output Power)
Input
of Load
Watts
173.06 12.1/0.1 3.3/3.2 5.1/3.2 5/0.5 143.25
Light
414.80 12.1/0.3 3.3/7.9 5.1/7.9 5/1.2 357.29
Typical
844.80 12.1/0.5 3.3/15.7 5/15.8 4.9/2.5 708.89
Full
Output Watts
110-240 Volts
8-4 Amps
50-60 Hz
700 Watts
12V (cumulative of 12V1, 12V2, etc.)
86.14%
84.27%
YES
200
150
100
50
0
0 0.003 0.006 0.009 0.012 0.015
-50
Voltage (V)
-100
-150
-200
DC Terminal Voltage (V)/ DC Load Current (A)
12.3/9.2
12.3/23
12.2/45.9
100%
90%
80%
70%
60%
50%
40%
Efficiency (%)
30%
20%
10%
0%
Loading (% of Rated Output Power)
Input Current and Voltage Waveforms
Time (s)
Voltage Current
Efficiency of the Power Supply
Output
Watts
Efficiency %
Efficiency
%
82.77%
86.14%
83.91%
6
4
2
0
-2
Current (A)
-4
-6
These tests were conducted by a third party independent testing firm on
behalf of the 80 PLUS Program. 80 PLUS is a certification program to
promote highly-efficient power supplies (greater than 80% efficiency in the
active mode) in technology applications. http://www.80plus.org/