GUANGDONG EAST POWER EA-IVS6000 Series User Manual

EA- IVS6000 user manual
Page 1 of 15 GUANGDONG EAST POWER CO.,LTD
EA- IVS6000 Series Sine-Wave Inverter
USER MANUAL
EA- IVS6000 user manual
Page 2 of 15 GUANGDONG EAST POWER CO.,LTD
INDEX
I EA-IVS6000 Series Model Notes……………………………………3
IIEA -IVS6000 Series Model table……………………………………4
IIIEA-IVS6000 Series Model Functions………………….……………5
IVEA-IVS6000 Series Model Technical Specifications….……….………7
V、 EA-IVS6000 Series Model Use Method………………………………8
VIEA-IVS6000 Series Maintenance Information……………….………9
VII EA- IVS6000 Series LCD Information……………….………11
VIII EA-IVS6000 Series Model Mechanical Information….……………11
IXAttached Accessories…………………………..……………………15
EA- IVS6000 user manual
Page 3 of 15 GUANGDONG EAST POWER CO.,LTD
IMPORTANT SAFETY NOTES
l Please keep this manual for future use. l Please read this manual carefully at the first time, and install, operation and maintain as per
u the manual instructions.
l AC input voltage of the series is 220V/50Hz, DC input voltage
12VDC/24VDC/48VDC/110VDC/220VDC,please connect as per the instructions, avoiding the possible damage.
l Please turn off the inverter and disconnected all cables before moving. l For avoiding the damage and hurt to people and inverter, please don’t open cover by
yourself.
l Do not use it with overload which can effect inverter life. l Please put the inverter in the dry place, at least 10cm away from the wall. l Protecting from direct sunlight, rain and moisture. l Please put it far away from fire and high temperature. l Please do not put things on the top of inverter.
l Please contact dealer or manufacturer service center for any problem, do not open the cover
avoiding any further damage and risk.
Warning
The  product  can  be  effected  by  the  radio  under  certain 
circumstances, further protection equipment is needed. 
EA- IVS6000 user manual
Page 4 of 15 GUANGDONG EAST POWER CO.,LTD
I. EA -IVS6000 Series Model Notes:
SET XX/220-XXXX L/W
W…………Desk Type
L………..19 Inch Rach Type
XXXX…….Power (VA)
220……..AC Output Voltage
XX……….DC Input Voltage
SET……..SETEC Company
II. EA-IVS6000 Series Model Table
Chart1EA-IVS6000 Series Table
EA 12 Series EA 24 Series EA 48 Series EA 110 Series EA 220 Series
EA 12/220-500L EA 24/220-500L EA48/220-500L EA 110/ 220- 500L EA 220/220- 500L
500VA
EA 12/220-500W EA 24/220-500W EA 48/220-500W EA 110/ 220- 500W EA 220/220-500W EA 12/220 -1000L EA 24/220 -1000L EA 48/220-1000L EA110/220-1000L EA 220 /220 -1000L
1000VA
EA 12/220-1000W EA 24/220-1000W EA 48/220- 1000W EA 110/ 220- 1000W EA 220/220-1000W
EA 24/220 -2000L EA 48/220-2000L EA110/220-2000L EA 220 /220 -2000L
2000VA
WITHOUT
EA 24/220-2000W EA 48/220- 2000W EA 110/ 220- 2000W EA 220/220-2000W EA 24/220 -3000L EA48/220-3000L EA110/220-3000L EA 220 /220 -3000L
3000VA
WITHOUT
EA 24/220-3000W EA 48/220- 3000W EA 110/ 220- 3000W EA 220/220-3000W
EA 48/220-4000L EA110/220-4000L EA 220 /220 -4000L
4000VA
WITHOUT WITHOUT
EA 48/220- 4000W EA 110/ 220- 4000W EA 220/220-4000W EA 48/220-5000L EA110/220-5000L EA 220 /220 -5000L
5000VA
WITHOUT WITHOUT
EA 48/220- 5000W EA 110/ 220- 5000W EA 220/220-5000W EA 48/220-6000L EA110/220-6000L EA 220 /220 -6000L
6000VA
WITHOUT WITHOUT
EA 48/220- 6000W EA 110/ 220- 6000W EA 220/220-6000W
EA- IVS6000 user manual
Page 5 of 15 GUANGDONG EAST POWER CO.,LTD
III. EA-IVS6000 Series Functions
With the development of information and network technology, the new generation DC -AC power supply, sine -wave inverter, are widely used in telecom, mobile, air field, banking, office, industry, hospitals, military and research fields. By using battery as DC input, and sine-wave AC output after inverter, the output voltage and frequency of Sine-wave inverter are very steady and can work continuously, avoiding the problems of power break, voltage unsteady, noise and lightning invasion. With the sine-wave inverter can guarantee the utility and equipment reliable work and system safety.
Sine-wave Inverter is a kind of DC-AC power supply, the output wave is pure sine-wave by SPWM technology, with the features of fast reaction, low wave distortion, output voltage and frequency steady. This inverter is also equipped with the protections of over DC input, low voltage, over AC output, overload, circuit shortage and internal over heat, these can guarantee good performance, working reliability and other technical specifications.
Sine-Wave inverter is designed based on center control system to meet the power supply requirements of computer and other terminals, mainly applying for: l Various managing equipment of digital communication system, including terminal, monitor
and cashier equipment.
l Server, intelligent platform of information network system, power system and instrument. l Suitable for system which has main power of DC and require AC power system.
Features of Inverter:
a) With micro-CPU control, EA-IVS6000 Series inverter is an intelligence model
product, good designing and reliability are the advantages.
b) EA-IVS6000 series inverter is adopting SPWM technology, with the output of
stabilized voltage and frequency, pure sine-wave.
c) EA-IVS6000 series inverter has good compatibility, built-in by-pass switch, high
overload feature for reliable and continuous power supply.
d) EA-IVS6000 series inverter can be AC power type and DC power type:
AC power type means the city power supply is main when the city power is normal, when city power is off, inverter comes into work state. DC power type means the inverter power supply is main when the city power is normal, when inverter power is off, city power comes into work state automatically.
e) With the excellent designing, EA-IVS6000 series inverter can be auto switched to
bypass on the running state, its easy to maintain and replace the battery without effecting load power supply.
f) In case there is battery voltage high/low or overload, the overload warning shutdown
output, when battery voltage recovers normal, battery voltage recovers; power supply