GUANGDONG BIOLIGHT MEDITECH WT3 User Manual

WT3 Electronic Thermometer
Users Manual
Guangdong Biolight Meditech Co., Ltd.
1
Product Model: WT3 Product Name: Electronic Thermometer Manufacturer Name: Guangdong Biolight Meditech Co.,Ltd. After Service Contact Information:
Address: No.2 Innovation First Road, Technical Innovation Coast, Hi-tech
Zone, Zhuhai, P.R. China Fax: +86-756-3399919 Post code: 519085 Toll-free consultation hot line: +86-400-8818-233
Revision History
This manual has a revision number. This revision number changes whenever the manual is updated due to software or technical specification change. Contents of this manual are subject to change without prior notice.
Document No.: J/ WT3CE -A-008 Revision number: V1.0 Release time: April, 2017
Copyright © 2017 Guangdong Biolight Meditech Co., Ltd. All rights reserved.
CE mark
EC Representative Name:
Shanghai International Holding Corp. GmbH Europe)
EC Representative Address:
Eiffestrasse 80, 20537 Hamburg Germany
2
Statement
Manufacturer holds the copyright of this manual, and we are also entitled to deal with this manual as confidential files. This manual is only used for operation, maintenance and service of product, someone else can not publish the manual.
This manual contains exclusive information protected by copyright laws and we reserve its copyright. Without written approval of manufacturer no parts of this manual shall be photocopied, Xeroxed or translated into other languages.
The contents contained in this manual are subject to amendments without
notification.
Manufacturer's Responsibility
Only under the following circumstances will manufacturer be responsible for the
safety, reliability and performance of the instrument: All the installation, expansion, readjustment, renovation or repairs are conducted
by the personnel certified by manufacturer.
The storage condition, operation condition and electrical status of the instrument
conform to the product specification.
The instrument is used in accordance with the users manual.
About this manual
This manual contains the instructions necessary to operate the product safely and in accordance with its function and intended use. Observance of this manual is a prerequisite for proper product performance and correct operation. This manual is based on the maximum configuration and therefore some contents may not apply to your product. If you have any question, please contact us. This manual is an integral part of the product. It should always be kept close to the equipment so that it can be obtained conveniently when needed.
Illustrations are for reference only. They may be not in conformity with your
products.
3
Signs in this manual
Warning: Indicates a potential hazard or unsafe practice that, if
not avoided, will result in death or serious injury.
Caution: Indicates a potential hazard or unsafe practice that, if not avoided, could result in minor personal injury or product/property damage.
Note: Provides application tips or other useful information to ensure that you
get the most from your product.
I
Contents
1. Intended Use ............................................................................................................................. 1
2. Application ................................................................................................................................ 1
3. Contraindication ........................................................................................................................ 1
4. Product Component ................................................................................................................... 1
5. Safety Information .................................................................................................................... 1
6. Appearance ............................................................................................................................... 4
7. Download and Install The Software .......................................................................................... 4
8. Operation Instructions ............................................................................................................... 5
9. Normal Body Temperature ........................................................................................................ 8
10. Maintenance and Cleaning .................................................................................................... 9
11. Accessory and Specifications .............................................................................................. 10
12. Troubleshooting .................................................................................................................. 11
13. Equipment Symbols ............................................................................................................ 12
Appendix A Guidance and Manufacturer’s Declaration of EMC ................................................... 13
1
1. Intended Use
The device is intended to be used for measuring and monitoring human temperature continuously. It can store and manage the temperature data. It can be used to measure armpit temperature for the adult and pediatric people.
2. Application
The device is intended for measuring human temperature. It can be used in
hospital and at home.
3. Contraindication
People whose armpit skin are damaged or have inflammation of the skin are
forbidden.
4. Product Component
The product is composed of main unit and temperature patch, mobile terminal
and PC terminal software.
5. Safety Information
Warning
Any form of modification to this device is forbidden; Dont used the device together with MRI or CT equipment; Explosion danger: dont use the device in flammable anesthetic gas; Dont squeeze the device. If the housing is broken, please stop using the
device.
2
Caution
Please check device regularly to make sure that it contacts skin tightly;
otherwise the data may be inaccurate.
The device is for indoor use only; Please pay attention to the operation temperature and humidity. Using the
device in a condition that does not satisfy the requirement may lead measurement error;
The effective wireless transmission distance is no less than10m. If more than
this distance, the product might not work. Please use this product within effective wireless transmission distance;
After measuring temperature, please take the temperature patch off the
main unit to avoid the main unit keep starting up all the time and reduce the electric quantity.
Muscle and fat affect wireless transmission, so the transmission range would
be weaken when adult or obese child use the device.
Magnetic and electrical fields are capable of interfering with the proper
performance of the device. For this reason make sure that all external equipments operated in the vicinity of the device comply with the relevant EMC requirements. Mobile phone, X-ray equipment or MRI devices are a possible source of interference as they may emit higher levels of electromagnetic radiation.
Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference; (2) This device must accept any interference received, including interference
that may cause undesired operation.
The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment
FCC STATEMENT:
This equipment has been tested and found to comply with the limits for a
Loading...