3.1 Test Setup..........................................................................................................................................4
4 Set IP-Address Dialogue...........................................................................................................................8
4.1 To set the reader IP-Address..............................................................................................................8
5 Set Password Dialogue..............................................................................................................................9
5.1 To set a password...............................................................................................................................9
5.2 To reset the password ( to default )...................................................................................................9
6 Set Power Dialogue.................................................................................................................................10
6.1 To set the power level......................................................................................................................10
Congratulations on purchasing a GTSYS Integraded RFID Reader. The reader can be delivered for 860 – 960
MHz (subject to regulatory region). The supported protocols are EPC Class1Gen2 / ISO18000-6C.
It has been verified to work with tags from:
•Alien
•Avery Dennison
•Impinj
•Mikoh
•RSI/Sirit
•TI
•UPM Raflatac
•Star Systems International
The read range is up to 10m, depending on the tag used and power setting.
Use this guide for more information on setting up your RFID Reader and learning how it works.
Next Chapter: Installing the IR-U-POE/IR-E-POE
Install the APToolUniversal software. The software program can be copied from the CD to your PC.
GTSYS LTD. R07 9/F Kwai Shing Ind. Bld Phase 2, 42-46 Tai Lin Pai Road, Kwai Chung, HONG KONG SAR – Email: sales@gtsys.com.hk
For the reader to work properly, install the programs on your computer before you connect your Reader to your
computer.
1. Insert the accompanying CD into the CD tray of your computer.
2. Start the APToolUniversal.msi program from the CD and follow the instructions in the installation wizard.
3. Make sure your PC is connected to the same network as the Integrated RFID Reader.
4. Install the Integrated RFID Reader to a proper mounting pole and connect the Ethernet port with the
PoE-Injector. The Injectors data port must connected to the network with DHCP service available.
Power-up the PoE-Injector.
RFID Reader
Access point
PoE-Injector
PC (running Windows 7)
Next chapter: 3Start APToolUniversal
GTSYS LTD. R07 9/F Kwai Shing Ind. Bld Phase 2, 42-46 Tai Lin Pai Road, Kwai Chung, HONG KONG SAR – Email: sales@gtsys.com.hk
GTSYS provides a testtool: APToolUniversal. It is available from the Start menu after the
installation process has sucessfully finished. The path to the program is: Start -> Program ->
APToolUniversal
APToolUniversal can't discover the reader automatically. After the reader had completely
started the LED show a static green in combination with a heart-beat blue. At this stage the
reader had retrieved a IP address from the DHCP server or use the Discovery-tool comes with
the software installation. The MAC address is written on a label next to the RJ45 Ethernet port.
Connect the tool to the reader using the Settings menu tab and select "Set IP Address" see
chapter 8 for details.
Illustration 1: APToolUniversal Start-up Screen
Illustration 2: Reader Discovery
GTSYS LTD. R07 9/F Kwai Shing Ind. Bld Phase 2, 42-46 Tai Lin Pai Road, Kwai Chung, HONG KONG SAR – Email: sales@gtsys.com.hk
Test the frequency hopping behavour of the RFID reader. In this mode the reader change the
frequency and hopping over the channels defined per selected region.
FCC: 50 channels, ETSI: 4 channels, India: 3 channels
To proceed with the frequency hopping test:
•Select the tab 'Hopping Test'
•Set the power if needed (see page 10 - 6.1To set the power level)
•Click the 'Start' button to make the RFID reader run the test mode.
The carrier indication Icon change from 'Carrier off' to 'Carrier on'
•Click the 'Stop' to stop the test.
The carrier indication Icon change from 'Carrier on' to 'Carrier off'
GTSYS LTD. R07 9/F Kwai Shing Ind. Bld Phase 2, 42-46 Tai Lin Pai Road, Kwai Chung, HONG KONG SAR – Email: sales@gtsys.com.hk
To connect the APTool with the integrated RFID reader via TCP/IP you must know the readers IPAddress. This can be determined from the leases table of the DHCP server. The readers MAC address is
written on a label close to the RJ45 Ethernet connector
4.1 To set the reader IP-Address
•Select “Settings->Set IP-Address” from the top menu bar
•Type a IPv4 dotted decimal address to the input field
•Click on “OK”
Illustration 5: Set IP-Address
Notice:
If a connection had been established, the network icon in the status bar changed
from
→
and the current IP address is show.
GTSYS LTD. R07 9/F Kwai Shing Ind. Bld Phase 2, 42-46 Tai Lin Pai Road, Kwai Chung, HONG KONG SAR – Email: sales@gtsys.com.hk
The EPC/Gen2 RFID tags have a feature to protect information with a password this dialogue
allows you set a password while reading or writing onto a RFID tag.
5.1 To set a password
•Select “Settings->Set Password” from the top menu bar
•Type a 8 charter hexadecimal password
•Click on “OK”
5.2 To reset the password ( to default )
•Select “Settings->Set Password” from the top menu bar
•Type “00000000” into the input line
•Click on “OK”
GTSYS LTD. R07 9/F Kwai Shing Ind. Bld Phase 2, 42-46 Tai Lin Pai Road, Kwai Chung, HONG KONG SAR – Email: sales@gtsys.com.hk
Notice: High power values can have a negative effect to the read/write results – it is recommend to start
from low (min) to high (max) power values in small steps to find the optimal setting.
Illustration 7: Set Power Dialogue
Quick Reference Guide
7Menu
APTool menu and shortcuts.
7.1 Main menu
APTool comes with 3 menu items:
•File
* Exit application
•Settings
* Set IP-Address
* Set Power
* Set Password
•Help
* About
7.2 Application short-cuts
APTool SoftwareFunctions
Alt-FFile Menu
Alt-SSettings Menu
Alt-HHelp / About
Alt-RActivate Read Tab
Alt-WActivate Write Tab
Alt-TSet/unset TID read
Alt-SSet/unset Bank3 read
Ctrl-XExit program
Ctrl-HAbout
Ctrl-ISet IP-Address
Ctrl-PPower Dialogue
Ctrl-APassword Dialogue
GTSYS LTD. R07 9/F Kwai Shing Ind. Bld Phase 2, 42-46 Tai Lin Pai Road, Kwai Chung, HONG KONG SAR – Email: sales@gtsys.com.hk
GTSYS and the GTSYS logo are trademarks of GTSYS Ltd. in Hong Kong and other countries.
Microsoft, Windows, the Windows logo are trademarks of Microsoft Corporation in the U.S.
and other countries. All other products names mentioned herein may be trademarks of their
respective companies.
GTSYS Ltd. shall not be liable for technical or editorial errors or omissions contained herein of
for incidental or consequential damages in connection with the furnishing, performance, or use
of this material. The information in this document is provided “as is” without warranty of any
kind, including, but not limited to, the implied warranties of merchantability and 4tness for a
particular purpose, and is subject to change without notice. The warranties for GTSYS products
are set forth in the express limited warranty statements accompanying such products. Nothing
herein should be construed as constituting an additional warranty.
This document contains proprietary information that is protected by copyright. No part of this
document may be photocopied, reproduced, or translated to another language without the
prior written consent of GTSYS Ltd.
GTSYS LTD. R07 9/F Kwai Shing Ind. Bld Phase 2, 42-46 Tai Lin Pai Road, Kwai Chung, HONG KONG SAR – Email: sales@gtsys.com.hk
§ 15.19 Labelling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
§ 15.21 Changes or modification warning
Any Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
§ 15.105 Information to the user.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and can
radiate radio frequency energy
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between thee quipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
* RF warning :
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the
radiator & your body.
and, if not installed and used in accordance with the instructions,