GTO SW-2000XL Installation Manual

Page 1
Installation Manual for the
®
1-800-543-GATE (4283) • www.gtopro.com
SINGLE Gate Operator System
FOR PROFESSIONAL INSTALLATION ONLY!
WARNING!
This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO, Inc. from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic gate operator. This gate operator produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on vehicular gates only.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety,
as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
3121 Hartsfield Road • Tallahassee, Florida, USA 32303
Telephone GTO Sales: 1-800-543-GATE (4283) or (850) 575-0176 • Fax (850) 575-8912
or GTO Technical Service: 1-800-543-1236 or (850) 575-4144 • Fax (850)575-8950
www.gtopro.com
©
2007 GTO, Inc.
R2000XL INST
rev - 2/22/07
Page 2
The GTO/PRO® 2000XL Gate Operator is intended for use with vehicular swing gates. The operator can be used in Class I, Class II, Class III and Class IV applications.
VEHICULAR GATE OPERATOR CLASS CATEGORIES
Residential Vehicular Gate Operator-Class I: A vehicular gate operator (or system) intended for use in a home
of one-to-four single family dwelling, or a garage or parking area associated therewith.
Commercial/General Access Vehicular Gate Operator-Class II: A vehicular gate operator (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public.
Industrial/Limited Access Vehicular Gate Operator–Class III: A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
Restricted Access Vehicular Gate Operator–Class IV: A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
Conversion Chart
Converting Metric Units to English Equivalents
When You Know Multiply By To Find Symbol
centimeters 0.3937 inches in. (or ") meters 3.2808 feet ft. (or ') kilograms 2.2046 pounds lb. (or #)
Converting English Units to Metric Equivalents
When You Know Multiply By To Find Symbol
inches 2.5400 centimeters cm feet 0.3048 meters m pounds 0.4535 kilograms kg
Converting Temperature
deg. Celsius (ºC x 1.8) + 32 deg. Fahrenheit ºF deg. Fahrenheit (ºF-32) ÷ 1.8 deg. Celsius ºC
FOR YOUR RECORDS
Please record the product serial number (located on the right hand side of the control box), and the date and place of purchase in the spaces provided below. Refer to this information when calling GTO for service or assistance with your automatic gate
Serial Number ____________________ Date of Purchase ____________________
Place of Purchase ____________________
Remember to keep all receipts for proof of purchase.
Page 3
Table of Contents
Gate Operator Class Categories ------------------------------------------------------------inside cover Units and Standards Conversion Chart ---------------------------------------------------inside cover
PLEASE READ THIS FIRST! --------------------------------------------------page iii
Important Safety Instructions --------------------------------------------------page 1
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Disconnecting the Operator ----------------------------------------------------------- page 1 Important Safety Instructions for the Consumer ------------------------------------ page 2 Secondary Means of Protection Against Entrapment ------------------------------ page 5 Required Safety Precautions for Gates -----------------------------------------------page 6 Warning Signs and Labels -------------------------------------------------------------page 7
Installation --------------------------------------------------------------------------page 8
Parts List ---------------------------------------------------------------------------------page 8 Technical Specifications -------------------------------------------------------------page 10
Installation Overview ------------------------------------------------------------------page 11
Installation of the Mounting Hardware ----------------------------------------------page 12 Mounting the Operator ----------------------------------------------------------------- page 16 Installation of the Closed Position Stop ---------------------------------------------page 16 Mounting the Control Box ------------------------------------------------------------- page 17 Connecting the Power Cable --------------------------------------------------------- page 18
Powering the System --------------------------------------------------------------page 19
Solar Chart -------------------------------------------------------------------------------page 19 Connecting the Transformer -----------------------------------------------------------page 19
Control Board Settings ----------------------------------------------------------page 22
DIP Switches ----------------------------------------------------------------------------page 22 Setting the Closed Position ------------------------------------------------------------ page 23 Obstruction Sensitivity -----------------------------------------------------------------page 24
Setting Your Personal Transmitter Code -------------------------------------page 25
Installing the Receiver -----------------------------------------------------------page 26
Connecting Additional Safety Devices ----------------------------------------page 27
Connecting Accessories ----------------------------------------------------------page 29
Push to Open Installation --------------------------------------------------------page 31
Maintenance & Troubleshooting Guide --------------------------------------page 33
Repair Service ---------------------------------------------------------------------page 36
Accessory Catalog ----------------------------------------------------------------page 37
Page 4
PLEASE READ THIS FIRST!
®
Thank you for purchasing a GTO/PRO® 2000XL When correctly installed and properly used, your GTO/PRO® 2000XL Operator will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. This manual will enable you to properly install your GTO/PRO® 2000XL Automatic Gate Operator.
The GTO/PRO® 2000XL Operator is designed for installation on a pull-to-open single leaf gate (gates that open into the property). By purchasing an accessory bracket, the GTO/PRO® 2000XL Operator can accommodate a
push-to-open single leaf gate (gates that open out from the property). The gate must not exceed 12 feet in length (per leaf) nor weigh more than 400 pounds (per leaf) (please see Technical Specifications on page 10). The GTO/PRO® 2000XL Operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates. Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind. If the wind is strong enough, the operator will obstruct and stop.
The GTO/PRO® 2000XL Operator accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories (see the enclosed GTO/PRO® Accessory Catalog) are available.
The GTO/PRO® 2000XL Operator features adjustable obstruction sensing. This safety feature makes the gate stop and reverse direction within 2 seconds when it comes in contact with an obstruction. MIN is the factory setting; meaning the gate will exert the minimum force on an obstruction before it stops and reverses direction.
The GTO/PRO® 2000XL Operator also has an adjustable auto-close feature. After the gate reaches the fully open position, it can be set to remain open up to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate opens fully will cause it to close immediately. OFF is the factory setting; meaning the gate will stay open until you press the transmitter (or keypad, etc.) again.
Please call GTO at (800) 543-GATE [4283] or (850) 575-0176 for more information about our GTO/PRO® professional line of gate operators and accessories. Our Sales Department will be glad to give you the name and phone number of a GTO/PRO® dealer near you.
BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:
Read these instructions carefully and completely to become
familiar with all parts and installation steps.
You must read the installation manual for detailed instructions on
gate operator safety and proper use of the gate operator.
iii
Page 5
IMPORTANT SAFETY INSTRUCTIONS
Clevis Pin
Hairpin Clip
Gate Bracket
Front Mount
Bushing
Because automatic gate operators produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate operator systems. Keep in mind that the gate operator is just one component of the total gate operating system. Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the consumer. Because there are many possible applications of the gate operator, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product.
CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.
Precautions and warnings in this manual are identified with this warning symbol. The symbol identifies conditions that can result in damage to the operator or its components, serious injury, or death.
Because GTO automatic gate operators are only part of the total gate operating system, it is the responsibility of the consumer to ensure that the total system is safe for its intended use.
To Manually Open and Close the Gate, Follow the Procedure Below:
CAUTION: The gate will move freely and uncontrolled when the gate operator is removed from the gate. ONLY disconnect the operator when the control box power
switch is OFF and the gate is NOT moving.
Disconnecting the Operator
1. Turn control box power switch OFF.
2. Remove hairpin clip, clevis pin, and bushing from either the front or rear mounting point.
3. Remove the opener from the mount.
The gate can be opened and closed manually when the operator is disconnected.
NOTE: Substitute a Pin Lock for the clevis pin on the front mount of the gate operator to prevent unauthorized removal of the operator from the gate (see Accessory Catalog).
1
Page 6
IMPORTANT SAFETY INSTRUCTIONS
5ObSW\bVS =^S\>]aWbW]\
ZONE 2
ZONE 3
ZONE 4
ZONE 5
2`WdSeOg
ZONE 1
For The Consumer
WARNING: To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction
manual could cause severe injury and/or death, for which the manufacturer cannot be held responsible.
2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed far enough from the road to prevent traffic congestion.
3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates must not open into public access areas.
4. The gate and gate operator installation must comply with any applicable local codes.
I. Before Installation
1. Verify this operator is proper for the type and size of gate, its frequency of use and the proper class rating.
2. Make sure the gate has been properly installed and swings freely in both directions. Repair or replace all worn or damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance the performance of the operator and safety devices used with the system.
3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the operator for manual gate operation (see page 1).
4. This gate operator is intended for vehicular gates ONLY. A separate entrance or gate must be installed for pedestrian use (see page 6).
5. Always keep people and objects away from the gate and its area of travel. NO ONE SHOULD CROSS THE
PATH OF A MOVING GATE.
6. Pay close attention to the diagram below and be aware of these areas at all times.
Entrapment Zones for a Pull-To-Open Application
2
Page 7
IMPORTANT SAFETY INSTRUCTIONS
Moving Gate
Area
2`WdSeOg




NEVER INSTALL
any control device
within gray area
Entrapment Zones for a proper Pull-To-Open installation: Zone 1 – leading edge of the gate and the fence post. Zone 2 – between the gate and the gate post. Zone 3 – the path of the gate. Zone 4 – the space between the gate in the open position and any object such as a wall, fence, tree, etc. Zone 5 – pinch points between the opener and gate or post.
II. During Installation
1. Install the gate opener on the inside of the property and fence line. DO NOT install an opener on the outside of the
gate where the public has access to it.
2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched.
3. Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide additional protection against entrapment.
4. If push buttons or key switches are installed, they should be within sight of the gate, yet located at least 10 feet from any moving part of the gate (see diagram below). Never install any control device where a user will be tempted to reach through the gate to activate the gate opener.
5. Do not activate your gate opener unless you can see it and can determine that its area of travel is clear of people, pets, or other obstructions. Watch the gate through its entire movement.
6. Secure outdoor or easily accessed gate opener controls in order to prohibit unauthorized use of the gate.
Pull-To-Open Application
3
Page 8
IMPORTANT SAFETY INSTRUCTIONS
III. After Installation
1. Attach the warning signs (included) to each side of the gate to alert the public of automatic gate operation. It is your responsibility to post warning signs on both sides of your gate. If any of these signs or warning decals become
damaged, illegible or missing, replace them immediately. Contact GTO for free replacements.
2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in contact with the gate when it is moving or stationary.
3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.
4. Do not attempt to "beat the gate" while the gate is closing. This is extremely dangerous.
5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep the remote controls away from children and unauthorized users; store controls where children and unauthorized users do not have access to them.
6. KEEP GATES PROPERLY MAINTAINED. Always turn power to operator OFF before performing any maintenance. Clean the push-pull tube with a soft, dry cloth and apply silicone spray to it at least once per month.
7. Service the gate and gate operator regularly. Grease hinges, spray push pull tube with high quality silicone spray and replace the battery every 3-5 years.
8. To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation
(see page 1). If you have read the instructions and still do not understand how to disconnect the operator, contact the
GTO Service Department.
9. Disconnect the operator ONLY when the power is TURNED OFF and the gate is NOT moving.
10. Make arrangements with local fire and law enforcement for emergency access.
11. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS section of this manual with all persons authorized to use your gate.
12. IMPORTANT: Save these safety instructions. Make sure everyone who is
using or will be around the gate and gate operator are aware of the dangers associated with automated gates. In the event you sell the property with the gate operator or sell the gate operator, provide a copy of these safety instructions to the new owner.
Should you lose or misplace this manual, a copy can be obtained by
downloading one from the GTO/PRO® web site (www.gtopro.com), by contacting GTO, Inc., at 3121 Hartsfield Road, Tallahassee, Florida 32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge.
4
Page 9
IMPORTANT SAFETY INSTRUCTIONS
Vehicular Gate
Leading Edge Contact Sensor
on both sides of the gate
Bottom Edge Contact Sensor
on both sides of the gate
Post Edge Contact Sensor
on both sides of the gate
Secondary Means of Protection Against Entrapment
As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary means to protect against entrapment. The GTO/PRO® 2000XL utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the primary type of entrapment protection. Also, the GTO/PRO® 2000XL has provisions for the connection of Type B2 protection to be used as the secondary type of entrapment protection, if desired.
1. For gate operators utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4 [i]):
A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and
outside of a vehicular swing gate system.
B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the
sensor and the gate operator is not subjected to mechanical damage.
C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for
entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
ENTRAPMENT ALARM (UL 325; 30A.1.1A)
The GTO/PRO® 2000XL Automatic Gate Operator is designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these operators are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the operator receives an intended signal from a hardwired entry/exit source (e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm.
5
Page 10
IMPORTANT SAFETY INSTRUCTIONS
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or play in gate area.
3. This gate is for vehicles only. Pedestrians must use a separate entrance.
Moving Gate Can Cause
Injury Or Death
WARNING
!
Warning Sign
Pedestrian Gate
Bulldog Pedestrian
Gate Lock
Vehicular Gate
Contact Sensor
(recommended, not included)
Contact Sensor
(recommended, not included)
Contact Sensor
(recommended, not included)
(recommended, not included
)
Required Safety Precautions for Gates
Install Warning Signs
Warning signs alert people of automatic gate operation and are required when installing the GTO/PRO® 2000XL Automatic Gate Operator. Furthermore, a walk-through gate must be installed if pedestrian traffic is expected near the vehicular gate. We recommend using the GTO Bulldog Pedestrian Gate Lock (Call the GTO Sales Department) for controlled access.
Entrapment Protection
GTO’s inherent obstruction settings, even when properly adjusted, may not be sensitive enough to prevent bodily injury in some circumstances. For this reason, safety devices such as safety edge sensors (or photoelectric sensors), which stop and
reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment.
Warning Signs
The warning signs (at right) must be installed on both sides of the gate (see page 7 for details).
6
Page 11
!
Warning signs (2 enclosed) to be installed on each side of the gate (3–5 feet above the bottom of the gate)
Maximum Gate: 400 lb. (294.8 kg); 12 ft. (4.8 m) Voltage: 12 Vdc; Frequency: 0 Hz; Power: 25 W Class I, II, III and IV Vehicular Swing Gate Operator. Serial Number: XXXXXXXXXX
#xxxxxxx
Conforms to UL 325 STANDARDS
TO MANUALLY OPEN AND CLOSE THE GATE:
1. Turn control box power switch OFF.
2. Disconnect front or rear mount from gate bracket.
3. Pull operator away from front or real mounts.
DC SW-2000XL SERIES
GTO, Inc. Tallahassee, Florida USA
Disconnect operator ONLY when the control box power switch is OFF and the gate is NOT moving.
L
I
S
T
E
D
US
C
Product identification and manual operation instruction label (1) installed on right hand side of control box.
Logo and warning labels (2) installed on each side of operator housing.
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or play in gate area.
3. This gate is for vehicles only. Pedestrians must use separate entrance.
WARNING
!
MOVING GATE
Can Cause Injury or Death
1-800-543-GATE (4283) • www.gtopro.com
IMPORTANT SAFETY INSTRUCTIONS
These warning labels should be found
at the locations specified below.
If any of them are missing,
immediately contact GTO for
replacements.
7
Page 12
Single Gate Operator Parts List
6OW`^W\1ZW^ 
!&f"1ZSdWa>W\ 
#$f!"0]Zb
!&f 0]Zb
!&f!0]Zb 
!&f&0]Zb"
&<gZ]\1OPZSBWS"
!&EOaVS`'
!&:]QYEOaVS`%
#$EOaVS`
!&<cb%
#$<cb
6O`ReO`S
5ObS=^S`Ob]`/`[ e$>]eS`1OPZS
5ObS0`OQYSb
>]ab>Wd]b0`OQYSb
1cab][S`Ac^^]`b1O`R
>]ab0`OQYSb 
1Z]aSR>]aWbW]\ Ab]^>ZObS
@SQSWdS`;]c\bW\UAQ`Se#
®
E-Z GATE OPENER
!&0caVW\Ua 
 f !"0]Zb 
 EOaVS`"
!&f!"0caVW\U
 :]QY<cb"
!&f!"1ZSdWa>W\
Operator and Mounting Hardware
8
Page 13
Single Gate Operator Parts List (continued)
ON/OFF
Transformer (1)
Battery (1)
Control Box (1)
Warning Signs (2)
GTO Transmitter(1)
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or play in gate area.
3. This gate is for vehicles only. Pedestrians must use a separate entrance.
Moving Gate Can Cause
Injury Or Death
WARNING
!
Receiver (1)
Control Box and Electrical Components
YOU MAY ALSO NEED THESE ITEMS BEFORE YOU BEGIN THE INSTALLATION (Some of these items can be found in the Accessory Catalog page 38):
Low voltage wire (RB509 Series) will be needed to run from the transformer to the control box; length depends
PVC conduit.
If your gate is more than 1000' away from an ac power source you will need to use at least 5 watts of solar charging
If your fence post is made of wood and is less than 6" in diameter or 6" square, see page 12.
If your fence post is larger than 6" in diameter you will need threaded rods or carriage bolts longer than 8". See
If you have thin walled tube or panel gates, see Recommended Reinforcement Examples on page 12.
Depending on the type of gate, a horizontal cross member or mounting plate may be needed to mount the front of
Surge protection for transformer.
Some types of installations require U-Bolts.
Tools Needed
• Power Drill
• Open End Wrenches — 3/8", 7/16", 1/2", and 9/16"
• 3/8" Drill Bit
• Hacksaw or Heavy Duty Bolt Cutters
• Small (Flat Bladed) Screwdriver
• Phillips Screwdriver
• Tape Measure
• Level
• Wire Strippers
• C-Clamps — small, medium, and large
• Center Punch
• Extra person will be helpful
upon the distance between the transformer power supply and the control box. See Powering the System on page 19, and the Accessory Catalog.
power to trickle charge the battery. See the Accessory Catalog.
page 15.
the opener and gate bracket to the gate. See page 11, step 2; page 15, step 10.
Push-to-open applications will require Push-to-open bracket (347 IH).
9
Page 14
Technical Specifications
Number of Cycles Per Day
GTO/PRO 2000XL Gate Capacity /Cycle Chart
Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.
Gate Weight
Gate Length
400 lbs. 300 lbs. 200 lbs. 150 lbs. 100 lbs.
50 lbs.
145 155 165 175 185
5’ - 6’
135
125
115 105 135 145 155 165 175
8’
125
135
145
155
165
10’
115 125 135 145 155
12’
GTO/PRO® 2000XL AUTOMATIC GATE OPERATOR
DRIVE
• Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21 ºC to +71 ºC). Use of heater bands on arm and control box will enhance performance in extreme cold temperatures.
• Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm.
• Maximum opening arc of 110º. Approximate opening time (90º): From 15 seconds, depending on weight of gate.
• Generates 330 ft lbs of torque at 12v.
POWER
• The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
• Battery charge is maintained by a 120 Vac, 18 Vac output transformer rectified to 14.5 Vdc (40 VA) through the GTO control board. Blade-style control board fuse is rated for 15 A.
NOTE: The transformer should not be directly connected to any battery. Do not replace fuses
with higher ampere rated fuses; doing so will void your warranty and may damage your control board.
• Battery charge is maintained by GTO Solar Panel Charger: float voltage of 14.5 Vdc output from solar panel. A gated diode on the control board prevents battery discharge.
CONTROL
GTO microprocessor-based control board is set for pull-to-open gate installations. DIP switches can be
adjusted to accommodate an optional kit for push-to-open gates (see Accessory Catalog).
• Control board has temperature compensated circuits.
• A circuit on the control board regulates charging. "Sleep draw" is 15 mA; "active draw" is 2 to 5 A.
• Auto-memorization of digital transmitter code.
• GTO remote-mounted RF receiver tuned to 318 MHz.
• Operator length with push-pull tube fully retracted is 33¾", mounting point to mounting point. Max stroke is 13".
• Adjustable auto-close timer (OFF to 120 s), and obstruction sensitivity.
• Power terminal bock accommodates a transformer and solar panels.
• DIP switches simplify setup of gate operator.
• Accessory terminal block fully compatible with push button controls, digital keypads, safety loops, etc.
• Control board allows connection of safety edge sensors and photoelectric sensors.
• Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
OPERATIONAL CAPACITY
• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO/PRO® 2000XL Auto­matic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation.
NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
To determine the number of cycles the gate operator will perform using solar panels, please see the specifications
listed on page 19 or call (800) 543-1236 or (850) 575-4144 for more information.
* An operation cycle is one full opening and closing of the gate.
These specifications are subject to change without notice.
10
Page 15
Installation Overview
Horizontal Cross Member
Vertical Cross Member
Horizontal Cross Member
Gate Swings Evenly and Freely Hung Firmly and Plumb
Receiver
Post Bracket Assembly
Control Box with Battery
Gate Bracket
Single Gate Opener
Fence Post Set in Concrete Run 1000' (max.) of low voltage wire to control box from transformer (wire not included).
Power Cable
Closed Position Positive Stop Plate
120 Volt indoor Transformer
(surge protector
not supplied)
PVC conduit (not included)
to protect wire from lawn
mowers and weed eaters.
Warning Sign
Pull-to-Open Gates (Gate Opens into the Property)
The diagram shown below is an example of a pull-to-open installation on a chain link fence and single gate. Furthermore, if you have a push-to-open gate, you will need to purchase a push-to-open bracket (see Accessory Catalog) to properly configure your system. See Push to Open Installation on page 31 before proceeding.
Preparation of the Gate
Step 1
The gate must be plumb, level, and swing freely on its hinges. Wheels must not be attached to the gate. The gate must move throughout its arc without binding or
dragging on the ground. Note that gates over 250 lb. should have ball bearing hinges with grease fittings.
Step 2
The fence post must be secured in the ground with
concrete so it will minimize twist or flex when the operator is activated. We recommend you position the operator near the centerline of the gate to keep the gate from twisting and flexing. The addition of a horizontal or vertical cross member (if one is not already in place) to provide a stable area for mounting the gate bracket is also important.
11
Page 16
Installation of Mounting Hardware
Post  Bracket
Post  Pivot Bracket
Metal Plate
Wooden Post
Post Bracket
Post Pivot Bracket
Metal Plate
Wooden Post
Thin Walled Tube Gate
Steel Pipe Cut in Half
Gate Bracket
Gate Bracket
Wood or Metal Reinforcement
Gate Bracket
Panel Gate
1" x 6" Wood Reinforcement
(not supplied)
(not supplied)
The position of the post bracket determines the leverage and efficiency of the operator. The post bracket position also sets the clearance between the operator and gate in the open and closed positions (minimum 2 inches for safety reasons).
The curved design of the post bracket works well for installations on round and square fence posts. Because the post bracket carries the entire thrust of the active operator, bolts that completely penetrate the fence post must be used.
On wooden posts, place a metal plate or washer (not supplied) between the nuts and the fence post to prevent the thrust of the operator from pulling the bolts and washers out of the wood.
NOTE: A fence post smaller than 6" in diameter or 6" square should be made of metal instead of wood so that it will remain stable while the operator is moving the gate.
IMPORTANT:
We strongly recommend using steel pipe, wood or metal to reinforce thin walled tube gates or wood to reinforce panel gates as shown. These reinforcement methods will prevent damage to the operator and gate when the operator is installed.
Recommended Reinforcement Examples
12
Page 17
Determining the Mounting Position
3/8" x 2" Bolt
3/8" Nut
Post Pivot Bracket
Post Bracket
Post Bracket
3/8" Lock Washer
Post Bracket Assembly
3/8" Washer
1ZSdWa>W\
6OW`^W\1ZW^
>]ab0`OQYSb/aaS[PZg
0caVW\U
@SO`;]c\b
=^S`Ob]`
Clevis Pin
Hairpin Clip
Gate Bracket
Front Mount
Bushing
:SdSZ=^S`Ob]`
4S\QS>]ab
5ObS7\=^S\>]aWbW]\
:3D3:V]`Wh]\bOZQ`]aa[S[PS`
>]ab0`OQYSb/aaS[PZg
5ObS0`OQYSb
of the Post Bracket Assembly and the Gate Bracket
Step 3
Insert the 3/8" x 2" bolt through the center hole of the post brackets and post pivot bracket
as shown. Fasten a 3/8" lock washer, 3/8" washer and 3/8" nut
on the end of the bolt. DO NOT overtighten the nut because the post pivot bracket will have to be
NOTE: The following steps are intended for pull-to-open gate installations. If you are mounting your operator on a push-to-open gate (e.g., a gate on a sloped driveway) you will need to purchase a Push
To Open bracket (see Accessory Catalog). Also, see Push-to-Open
Installation beginning on page 31.
adjusted later.
Step 4
Attach post bracket assembly and gate bracket to the operator with the clevis pins and bushings. Secure the clevis pins with hairpin clips.
Step 5
With the gate in the open position (up to 110º from its closed position) and the operator fully retracted, adjust the post bracket assembly and gate bracket until the operator is level. While holding the operator level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate.
13
Page 18
Gate in the
CLOSED POSITION
Pinch Area
Gate in the OPENED POSITION
Pinch Area
2" minimum
2" minimum
Be sure gate opener and bracket don't bind.
IMPORTANT: While determining the mounting point for the post pivot bracket assembly, be sure that the position allows
Post
Post Bracket pivot point
Gate
A
B
Post Mount Example (A + B can not exceed 10 inches) Example: If A is 2" then B can not exceed 8"
Hinge
for minimum 2 inches of clearance between the gate and the operator in both the open and closed positions, as shown in the diagrams below. This clearance will give the operator the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area.
Step 6
When you have achieved the required position for the post pivot bracket in the open position, insert the 5/16" x 1-3/4" bolt through the aligned holes of the post bracket and post pivot bracket to hold it in place. Remove the clevis pin from the front mount and while supporting the gate operator, swing the gate and gate operator to the closed position. With the gate and gate operator in the closed position check the clearance and be sure that the gate operator is not binding at the post pivot bracket.
If you don't have 2 inches of clearance or the gate operator is binding on the post pivot bracket, remove the 5/16" x 1-3/4" bolt and readjust the pivot bracket until you can achieve these important clearances.
With the post pivot bracket in the optimum position for clearance and freedom of movement, reattach the operator to the gate bracket in the open position and recheck the gate operator level and make sure the brackets are clamped securely.
TIP: Turning the pivot bracket over gives
more hole alignment options for the post pivot bracket assembly. You can also move the entire post pivot bracket assembly to different positions on the gate post to help achieve the proper clearances.
14
Page 19
Installing the Post Bracket Assembly and Gate Bracket
@]c\RBcPS1VOW\:W\Y5ObS
A_cO`SBcPS5ObS
;]c\bW\U>ZObS 1`SObSRT]` 2SQ]`ObWdS5ObS `S_cW`SRPcb\]b ac^^ZWSR
@S[]dSSfQSaaP]ZbZS\UbV eWbVVOQYaOe]`P]ZbQcbbS`a
4@=<BD73E
A723D73E
4@=<BD73E
A723D73E
Round Metal Post
Round Wood Post
Square Metal Post
Square Wood Post
Remove excess bolt length  with hacksaw or bolt cutters
SIDE VIEW
TOP VIEW
EXAMPLES
Post Bracket Assembly
Mark fence post through middle of bracket slots and drill 3/8" holes
5ObS7\=^S\>]aWbW]\
:3D3:V]`Wh]\bOZQ`]aa[S[PS`
;O`YQ`]aa[S[PS`bV`]cUV[WRRZS]T UObSP`OQYSbaZ]baO\RR`WZZ!&V]ZSa
Step 7
Mark reference points for bolt holes on the fence post through middle of bracket slots. Marking reference points in this manner allows room for adjustment when mounting the post bracket assembly and gate bracket. After marking your reference points, remove the operator and brackets from the fence and gate.
Step 8
Drill 3/8" holes into fence post as marked.
Step 9
Fasten post bracket assembly to the fence post using (4) 3/8" x 8" bolts, washers, lock washers, and nuts (provided).
Remove excess bolt length extending beyond the tightened nuts with a hacksaw or bolt cutters.
NOTE: In cases where the fence post has a diameter larger than 6", threaded rods or carriage bolts longer than 8" (not supplied) must be used.
Step 10
Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots. Drill 3/8" holes into the
gate cross member as marked.
Mount gate bracket using (2)
3
/8" x 3" bolts, washers, lock washers, and nuts (provided). Cut off excess bolt length extending beyond the tightened nuts.
Gate Bracket Mounting Examples
15
Page 20
Mounting the Operator
Closed Position  Stop Plate
Closed Position Stop Plate mounted  on metal post with U-bolts.
Gate Hinge
The gate must open 80º (min.) to 110º (max.)
Fence Post
Gate Post
TOP VIEW
SIDE VIEW
:SdSZ=^S`Ob]`
4S\QS>]ab
5ObS7\=^S\>]aWbW]\
:3D3:V]`Wh]\bOZQ`]aa[S[PS`
>]ab0`OQYSb/aaS[PZg P]ZbSRb]TS\QS^]ab
1ZSdWa>W\0caVW\UO\R6OW`^W\1ZW^
1ZSdWa>W\0caVW\UO\R6OW`^W\1ZW^
5ObS0`OQYSbP]ZbSR b]UObSQ`]aa[S[PS`
Step 11
Attach the operator to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and hairpin clips, or optional Pin Locks (see Accessory Catalog). Verify that the operator is level and adjust the post bracket assembly if necessary.
Installation of the Closed Position Stop
The GTO/PRO® 2000XL Gate Operator firmly holds the gate in the closed position using the positive stop plate. The positive stop helps stabilize the gate leaf in the closed position. To further enhance the stability and security of your gate, install the optional GTO/PRO® Automatic Gate Lock (see Accessory Catalog).
Step 12
Remove hairpin, clevis pin, and washer from front mount and close the gate (remember to support operator). Fasten the closed position stop plate to the end of the gate frame on the gate centerline, but do not tighten it completely. Slide the stop plate toward the fence post until they touch (see illustration). Once you have moved the stop plate to the correct position, tighten its hardware completely.
Use the appropriate hardware for your type of gate (use U-bolts if you have a tube or chain link gate; wood or lag screws for wood gates; etc.). This hardware is not provided.
16
Page 21
At this stage of the installation, the operator should be installed on
Use mounting holes and screws provided to mount control box to a secure surface.
1Z]aSR>]aWbW]\Ab]^>ZObS
5ObS7\1Z]aSR>]aWbW]\
C
L
the gate and the closed position stop should be in place.
Check List
• The gate is plumb, level, and swings smoothly on its hinges.
• A plate or support was added for the gate bracket (if necessary).
• The operator is level and mounted on the centerline of the gate.
Mounting the Control Box
Step 13
Mount the control box using the screws (provided) or another secure mounting method. The control box must be mounted at least 3 feet above the ground to protect it from rain splash, snow, etc., and at least 3 feet from an AC power source to prevent
electrical interference.
NOTE: The battery that came with your GTO/PRO®
2000XL, MUST be placed in the top (horizontal) battery slot with the terminals on the RIGHT. The extra (vertical) battery slot is for an optional second battery. An optional second battery is recommended for solar and/or high traffic applications, if needed.
17
Page 22
Power Cable from
the Master Arm
RECEIVER
GTO RCVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN EDGE
COM
MASTER CABLE
CONTROL I NPUTS
CLOSE
EDGE
Correct
Wrong Wrong
Wire
Terminal  Block
Terminal  Block
Terminal Block
Wire Wire
Connecting Opener Power Cable
Sealing Nut
Hub
Lock Nut
Strain Relief
RED wire to POSITIVE (+) terminal
BLACK wire to NEGATIVE (–) terminal
RED
BLACK
25
FUSE
BATT+
BATT-
1 2 3 4
ON D IP
STATUS
LEARN RMT
RECEIVER
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
ALM
S2
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ONONPUSH
SIMULT.ONON
120 MIN MAX
CHARGING
PWR IN
GTO RCVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN EDGE
COM
GTO
TRANSF
LOCK
PWR
AUX
RLY
POWER
INPUTS
CONTROL
OUTPUTS
MASTER CABLESLAVE CABLE
CONTROL INPUTS
AUTO CLOSE TIME STALL FORCE
CLOSE EDGE
18 VAC
or
SOLAR
GTO
LOCK
AUX
1
2
3
4
5
6
7
Operator Power Cable
Strain Relief
Battery wires for optional second battery.
12 Volt Battery (included)
Space for optional second 12 Volt battery (see Accessory Catalog)
Step 1
Make sure the control box power switch is in the OFF position. The ON/OFF Switch is located on the bottom of the control box. Remove the control box cover and slide the battery into position with its terminals to the RIGHT (see illustration). Connect the BLACK battery wire to the NEGATIVE (–) battery terminal. Connect the RED battery wire to the POSITIVE (+) terminal. Pay close attention to the color of the wires. If the wires
are connected incorrectly, the control board will be damaged.
NEVER insert the battery with the terminals to the left.
Step 2
Strip approximately 3/16" of insulation from each wire of the opener power cable. Twist each exposed wire tightly (there are seven [7] wires inside the power cable sheath). Loosen sealing nut on strain relief hub at bottom of control box. Insert power cable into control box through strain relief. Thread approximately 6" of the power cable into the control box and retighten sealing nut until the power cable locks into place.
Step 3
Insert the stripped power cable wires into the appropriate terminals on the MASTER CABLE
terminal block. The green wire should be inserted into the GRN terminal, the white wire into WHT, the blue wire into BLU, brown wire into BRN, and the orange wire into the ORG terminal, red wire into RED, and black wire into BLK.
Tighten the set screws against the end of the wires. A dab of petroleum jelly on each terminal will help prevent corrosion.
18
Page 23
Powering the System
ON/OFF Switch
Installation of the Transformer
IMPORTANT:
The transformer is designed and intended for indoor use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover or housing (available at local electrical supply stores) must be used.
All low voltage wire used with the GTO/PRO® 2000XL Gate Opener must be 16 gauge dual conductor, multi-stranded, direct burial wire (see page 20 and the Accessory Catalog). Do not run
more than 1000 feet of wire.
If your gate is more than 1000 ft. from an ac power source, you will need to use at least one 5 watt Solar Panel to charge the battery (see Accessory Catalog). Refer to the Solar Panels and Gate Activity chart below.
Optional Solar Panels and Gate Activity
The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 5 to 30 watts of solar charging power. (see Accessory Catalog). The figures shown are
for winter (minimum sunlight) and do not account for the use of any accessory items. Accessories connected to
your system will draw additional power from the battery.
NOTE: A maximum of 30 watts of solar charging power can be connected to the GTO/ PRO® 2000XL Gate Opener. Consult Solar
Panel Installation Instructions for further information.
Winter Ratings Zone 1 Zone 2 Zone 3
12 v single gate (5 watts) solar charger 4 8 13 12 v single gate (10 watts) solar charger 8 16 26 12 v single gate (15 watts) solar charger 11 20 30 12 v single gate (20 watts) solar charger 14 28 38 12 v single gate (25 watts) solar charger 17 36 46 12 v single gate (30 watts) solar charger 20 44 54
Step 1
Make sure the power switch is OFF before proceeding to the next step.
Step 2
Select the electrical outlet into which you will plug the transformer. Measure the distance from this outlet to the control box following the path where the wire will be laid. After you have measured how much wire is needed, cut the wire to the appropriate length.
19
Page 24
IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE
Power Cable from Opener Arm
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
POWER
INPUT
LOCK
PWR
AUX
RLY
CONTROL
OUTPUTS
MASTER CABLESLAVE CAB LE
GTO 18VOLT
TRANSFORMER
OR SOLAR
GTO
LOCK
AUX
1
2
3
4
5
6
7
RED
BLACK
RED
BLACK
Low Voltage Wire from AC Transformer or Solar Panel
Low Voltage Wire from Transformer
Power Cable from Opener Arm
PVC Pipe
25
FUSE
BATT+
BATT-
1 2 3 4
ON DIP
STATUS
LEARN RMT
RECEIVER
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
ALM
S2
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ONONPUSH
SIMULT.ONON
120 MIN MAX
CHARGING
PWR IN
GTO RCVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN EDGE
COM
GTO
TRANSF
LOCK
PWR
AUX
RLY
POWER
INPUTS
CONTROL
OUTPUTS
MASTER CABLESLAVE CABLE
CONTROL INPUTS
AUTO CLOSE TIME STALL FORCE
CLOSE EDGE
18 VAC
or
SOLAR
GTO
LOCK
AUX
1
2
3
4
5
6
7
The only wire acceptable for use with GTO products is 16 gauge multi-stranded, low voltage, PVC sheathed wire. This particular gauge enables the transformer to provide an adequate charge through the control board to the battery at distances up to 1000 ft.
DO NOT use telephone wire or solid core wire. Unlike multi-stranded wire, these types of wire are
inadequate for use with your gate opener system. Telephone wire and solid core wire do not deliver enough voltage for your gate opener to function and will cause the system to go into a condition known as "low voltage lockout."
NEVER splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to
carry an adequate current.
Step 3
Lay the measured length of low voltage wire in a trench following a path from the selected electrical outlet to the control box. Wires coming up from the ground should be run through PVC conduit to protect them from lawn mower blades, weed eaters, and grazing animals. Be sure to bury the wire laid in the trench.
Step 4
Feed the low voltage wires upward through the strain relief opening on the lower left of the control box. Pull 6" to 8" of wire into the control box and tighten the strain relief screw to secure the wires.
WARNING! DO NOT PLUG THE TRANSFORMER INTO AN OUTLET DURING THIS STEP! THE TRANSFORMER MUST ONLY BE PLUGGED INTO AN OUTLET DURING STEP 7!
Step 5
Strip 3/16" off the ends of the low voltage wire and twist tightly. Attach these ends to the GTO 18VOLT TRANSFORMER OR SOLAR (GTO Transformer)
terminals located on the POWER INPUTS (GTO Transformer) terminal block (see illustration at right).
Be certain not to let the exposed wires touch each other!
Insert one transformer wire into an GTO TRANSFORMER terminal. Insert the other transformer wire into the remaining GTO TRANSFORMER terminal. The transformer wires
can be connected to the GTO TRANSFORMER terminals regardless of polarity or color.
Tighten set screws against exposed end of wires. A dab of household petroleum jelly on each terminal will help prevent corrosion.
20
Page 25
Step 6
SURGE PROTECTOR
Transformer
1
Strip
/2" of insulation from the ends of the low voltage
wire. Attach these stripped ends to the transformer terminals.
A dab of household petroleum jelly on each terminal will help prevent corrosion.
Make sure the exposed wires do not touch each other!
Step 7
Plug the transformer into the electrical outlet. (Use of a surge protector with the transformer is strongly recommended.)
HINT: Keep a few mothballs in the control box to discourage insects from entering it and damaging the control board.
21
Page 26
ON
OFF
1
ON DIP
2 3 4
1 2 3 4
ON DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIM IT
S3
S4
S2
OFF
SOFT STA RT OFF WARNING OFF OPEN PULL SLV OPE N DLY. MODE1 OFF MODE2 OFF
ON ON PUSH SIMULT. ON ON
120 MIN MAX
1
2 3 4
O
N DI
P
LEAR
N
MAST LI MIT
LEARN
S
LV LIMI T
S
S
4
S2
OFF
SO
FT START OFF
WARNING OFF
OPEN PULL
S
LV OPEN DLY
.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
S
IMULT.
O
N
O
N
120
MIN
MAX
S3
1 2 3 4
ON DIP
OFF OFF
ON ON PUSH SIMU ON ON
120 MIN
CONTROL BOARD SETTINGS
Auto Close Time Pot
1 2 3 4
ON DIP
STAT US
LEARN RMT
LEARN
MAST LIMIT
S3
S2
OFF
SOFT START OFF WARNING O FF OPEN PULL SLV OPE N D LY.
MODE1 OFF MODE2 OFF
ON ON PUSH SIMULT.
ON ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
DIP Switches
Main DIP Switch Settings (MODES)
DIP Switch #1 - Soft Start/Stop ON - Soft start enabled (factory preset). OFF - Soft start disabled.
The Soft Start/Stop feature slowly starts the
gate as it begins to open and slows the gate as it comes to the closed position. This saves wear and tear on the gate and gate opener system.
DIP Switch #2 - Warning Buzzer ON - Buzzer warning enabled (factory preset). OFF - Buzzer warning disabled.
The Warning Buzzer alerts you when the gate
opener is beginning to either open or close the gate. It sounds for the first 2 seconds in each direction. It also sounds a warning when the gate obstructs two times in one cycle. Switching this to OFF only disables the open and close warning not the obstruction warning.
DIP Switch #3 - Push/Pull-to-Open ON - Push to open. OFF - Pull to open (factory preset).
If your gate opens into the property the DIP
Switch is set to the OFF position (factory setting). If your gate opens out from the property the DIP Switch must be set to the ON position. NOTE: if you have a Push-to-Open gate application you will need a Push-to-Open bracket (see Push-to-Open Instructions on page 31).
DIP Switch #4 - Dual Operation ON - Slave opens simultaneously with master.
OFF - Slave opens after master.
Note: Not applicable for single gate operator.
Auto Close
The 'AUTO CLOSE TIME' pot controls auto close feature.
Turning the pot all the way counter-clockwise
will turn auto close feature off. The minimum auto close time is 3 seconds. The maximum (turn the pot all the way clockwise) auto close time is 120 seconds.
22
Page 27
Setting the Closed Position Limit
1 2 3 4
ON DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIM IT
S3
S4
S2
PULL
OFF OFF
ON ON PUSH SIMULT.
ON ON
120 MIN MAX
Learn Master Limit
Button
for Pull to Open Applications
TURN CONTROL BOX ON
Your GTO/PRO® 2000XL has two Limit Settings
1) OPEN Limit setting: (Gate in the OPEN POSITION / the limit is FACTORY SET and NOT ADJUSTABLE) The open limit setting is the fully open position.
2) CLOSED Limit setting: (Gate in the CLOSED POSITION) To achieve optimum closed position, you are required to complete the following FOUR STEPS:
Step 1
Confirm that the power switch is in the ON position and the gate is in the OPEN POSITION.
Step 2
Activate your opener by pressing the entry transmitter button. Your gate should now be moving from the fully open position toward the closed position. Prepare to STOP the gate by pressing the entry transmitter button again when the gate reaches the desired closed position. This step may be repeated until desired close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 3.
Step 3
With the gate in the desired closed position PRESS & HOLD the “LEARN MAST LIMIT" button on the control board for 5 seconds or until the buzzer sounds.
Step 4
Press the transmitter button and allow the gate to return to the fully open position. YOUR GATE’S CLOSED POSITION LIMIT IS NOW PROGRAMMED.
TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gate to close. If the CLOSED position is not correct or needs to be changed, you will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-4 again.
CLEARING THE PROGRAMMED CLOSED LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to the fully opened position, then press and hold the "LEARN MAST LIMIT" button for 5 seconds or until the buzzer sounds. This will clear the memory for the closed limit position. Follow Steps 1-4 again.
23
Page 28
Stall Force Potentiometer
1 2 3 4
ON DIP
OFF
SOFT START OFF WARNING OFF OPEN PULL SLV OPE N DLY.
MODE1 OFF MODE2 OFF
ON ON PUSH SIMULT.
ON ON
120 MIN
AUTO CLOSE TIME STALL FORCE
1 2 3 4
ON
ON
MIN MAX
STALL FORCE
IMPORTANT: For safety reasons the obstruction setting or Stall Force on the GTO/PRO® 2000XL control board comes from the facto­ry set at MIN (minimum). In many gate installations this setting will need to be adjusted to overcome the weight and size of the gates.
The Stall Force potentiometer on the control board operates like a volume control on a radio. It controls the obstruction sensitivity (or the amount of force the opener will apply to an obstruction) before it automatically stops and reverses direction for approximately two (2) seconds.
Use a small slotted screwdriver to turn the arrow in the center of the potentiometer. Adjust the stall force from the MINIMUM position where the gate operates without obstructing from its own weight or the wind conditions in your area.
ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR
SERVICING YOUR AUTOMATIC GATE OPENER!
24
Page 29
1
2
3 4 5 6 7 8
9
EC
E
A23S 12V
ALKALINE BA
TT
ER
Y
+
0
LE
D
Setting Your Personal Transmitter Code
1 2 3 4
ON D IP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIM IT
S3
S4
S2
PULL
OFF OFF
ON ON PUSH SIMULT.
ON ON
120 MIN MAX
Learn Remote
Button
+
0
ECE
1 2 3 4 5 6 7 8 9
All GTO transmitters are set to a standard code at the factory and are ready to operate your GTO/PRO® 2000XL Gate Opener®. For your safety and security, however, we strongly recommend that you replace the factory setting with your own personal code. Follow the directions below:
1. Remove the Transmitter Cover
On the back of the transmitter use a small phillips head screw driver to remove the two screws on the sides of the visor clip and separate the front cover from the transmitter. With the front cover removed, the battery and the DIP switches will be exposed. To set a new code, use a small screwdriver to move the switches.
2. Set the transmitter DIP Switches
There are nine (9) transmitter DIP switches; each can be placed in three different positions (+, 0, –). DO NOT set all the switches in the same position, such as all +, all 0, or all –. Once the DIP switches have been set to a personal code, replace front cover.
WARNING: No other adjustments should be made inside the transmitter.
3. “Teach” the New Code to Control Board Memory
A. Press and hold transmitter button. B. Press and hold the LEARN RMT (Learn Remote) button
on the control board until the buzzer sounds. C. Release transmitter button. The new code is stored in control board memory. D. Release the LEARN RMT (Learn Remote) button.
25
Page 30
Installing the Receiver
Use the transmitter to check the range of the receiver before permanently mounting it.
Consider the following when mounting the receiver:
• Standard receiver cable length is 10 feet (receivers with a longer cable are available as special order items; call the GTO Sales Department). NEVER splice receiver cable!
Run the cable through PVC conduit to protect it from damage.
• DO NOT run cable through metal conduit because the receiver signal range will be decreased.
• DO NOT run cable in conduit containing ac wiring.
• The receiver range can vary from 50 to 100 feet depending upon weather, topography, and external interference.
• DO NOT mount upside down.
• DO NOT mount on metal fence.
• MOUNT so that you have line of sight between remote and antenna.
• MOUNT 3 feet away from AC voltage.
• MOUNT as high as possible for optimum range.
FCC Regulation
This device complies with FCC rules Part 15. Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept an interference that may cause undesired operation.
Transmitter distance may vary due to circumstances beyond our control. NOTE:
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
26
Page 31
Connecting Additional Safety Devices
Wire from Contact Sensor (open safety edge)
Wire from Contact Sensor (close safety edge)
RECEIV ER
ALM
GTO RCVR.
BLK
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
CONTROL INPUTS
CLOSE
EDGE
Although GTO strongly recommends the use of additional safety devices, we do not endorse any
specific brand names. Only use products that are certified and listed to be in compliance with any
applicable UL standards (Underwriters Laboratories) and national and regional safety codes.
Call GTO Sales at 1-800-543-4283 for information on compatible
products for your specific application.
The GTO/PRO® 2000XL will ONLY accept accessory devices with normally open dry contact output.
Contact Sensors (safety edges)
If not installing a contact sensor skip to next section.
PLEASE NOTE: Contact sensors are not included with the GTO/PRO® 2000XL.
The GTO/PRO® 2000XL is equipped with built-in obstruction sensitivity. The opener is designed to stop and reverse the gate within 2 seconds when it comes in contact with an obstruction. However, obstruction sensitivity, although functioning properly, may not be sensitive enough to prevent bodily injury in some circumstances. To augment your protection against entrapment, GTO recommends using some form of additional safety device. When installed, contact sensors must be mounted in compliance with UL 325, Underwriters Laboratories safety standard for gate openers. Review page 5 for infor­mation about mounting requirements for safety edges ("contact sensors").
Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.
Make sure the power switch to the opener is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF.
Contact Sensor Input Connection:
Connect one of the OPEN EDGE contact sensor wires to the
COMMON (COM) terminal and the other to the OPEN EDGE terminal on the GTO/PRO® 2000XL control board.
Connect one of the CLOSE EDGE contact sensor wires to the
COMMON (COM) terminal and the other to the CLOSE EDGE terminal on the GTO/PRO® 2000XL control board.
Activation of a contact sensor while the gate is in motion will cause the gate to stop and reverse within two (2) seconds.
NOTE: If the close edge is contacted when the gate is opening, nothing happens. If the close edge is contacted when the gate is closing, then it reverses. If the open edge is contacted when the gate is clos­ing, nothing happens. If the open edge is contacted when the gate is opening, then it reverses.
27
Page 32
Non-Contact Sensors (photo beams/loop detectors)
Wire from Non-Contact Sensor (photo beam/loop detector)
RECEI VER
ALM
GTO RCVR.
BLK
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
CONTROL INPUTS
CLOSE
EDGE
Wire from Loop Detector
RECEI VER
ALM
GTO RCVR.
BLK
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
CONTROL INPUTS
CLOSE
EDGE
If not installing a non-contact sensor skip to next section.
PLEASE NOTE: Non-contact sensors are not included with the GTO/PRO® 2000XL.
The GTO/PRO® 2000XL can also accept "Safety" input from normally open "dry-contact" output devices such as photo beams connected to the SAFETY input terminal.
Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.
Make sure the power switch to the opener is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF.
Non-Contact Sensor Connection:
Connect one of the non-contact sensor dry contact output wires to the COMMON (COM) terminal and the other to the SAFETY terminal on the GTO/PRO® 2000XL control board.
This input is ONLY monitored when the gate is closing. Activating the non-contact sensor (obstructing the safety beam path) will cause the gate to reverse to the fully open position and will remain open as long as the contact is held.
Shadow Loop
If not installing a shadow loop skip to next section.
PLEASE NOTE: Non-contact sensors are not included with the GTO/PRO® 2000XL.
The GTO/PRO® 2000XL can also accept "Shadow Loop" input from Loop Detector that provides normally open "dry­contact" connected to "Shadow" input terminal.
Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.
Make sure the power switch to the opener is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF.
Shadow Loop Connection:
Connect the COM wire from the Loop Detector to the COMMON (COM) terminal and the other normally open wire
from the Loop Detector to the SHADOW terminal on the GTO/PRO® 2000XL control board.
The SHADOW LOOP is a detector located within the moving path of the gate to prevent the gate from closing when a vehicle is in the path.
This input is ONLY monitored when the gate is at the fully open position. Activating this will prevent the gate from closing.
28
Page 33
Connecting Accessories
OPEN STOP CLOSE STOP
Wire from Accessory (push button, key pad, etc.)
RECEI VER
ALM
GTO RCVR.
BLK
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
CONTROL INPUTS
CLOSE
EDGE
Wire from Exit/Entry Device (GTO Wand, Loop Detector etc.)
RECEI VER
ALM
GTO RCVR.
BLK
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
CONTROL INPUTS
CLOSE
EDGE
If not connecting accessories skip to next section.
Cycle Input
The GTO/PRO® 2000XL can accept NORMALLY OPEN, DRY-CONTACT accessories, such as; Push Button Entry De­vices and Key Pads.
Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.
Make sure the power to the opener is turned off before connecting cycle input device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF.
Cycle Input Connection:
Connect one of the accessory wires to the COMMON (COM) terminal and the other to the CYCLE
terminal on the GTO/PRO® 2000XL control board.
Each activation of the accessory will cause the gate to cycle as follows:
Free Exit Input
The GTO/PRO® 2000XL can accept NORMALLY OPEN, DRY-CONTACT free exit/entry devices such as GTO Wand and Loop Detector
Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.
Make sure the power to the opener is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF.
Free Exit Connection:
Connect one of the accissory wires to the COMMON (COM) terminal and the and the other to the EXIT
terminal on the GTO/PRO® 2000XL control board.
Activation of this input will cause the gate to open to the fully opened position. As long as contact is held, the gate will remain open.
29
Page 34
GT
O L
OCK
SOLAR
or
18 VAC
ORGBLUEWHTGRN BRN
SLAVE INPUT
LOCK
GTO AUX
GTO
TRANSF
LOCK
PWR
AUX
RLY
POWER INPUTS
CONTROL OUTPUTS
SLAVE CAB
Wire from Automatic GTO Lock
Connecting GTO Automatic Gate Lock
If not connecting gate lock skip to next section.
GTO Lock:
For use exclusively with GTO Lock (FM143 or FM144). Connecting other devices to these terminals may cause incorrect operation and void your warranty. You do not use the lock board with this control board.
GTO Lock Connection:
Connect the red and black leads from the lock to the GTO LOCK terminal on the GTO/PRO® 2000XL control board.
Connecting Other Auxiliary Devices (Mag Locks, Sirens, Lights, etc.}
• These 2 terminals are normally open 'dry-contact' (no voltage) relay ouput.
• These 2 terminals are ON (shorted) whenever the gate is moving and OFF (opened) otherwise.
• These 2 terminals maximum rating is 24Vdc, 1 Amp.
30
Page 35
Gate in the Closed Position
Pinch Area (gray)
Gate in the Open Position
Pinch Area (gray)
Two inch minimum
Two inch minimum
Push to Open Installation
3/8" x 2" Bolt
3/8" Nut
Post Pivot Bracket
Post Bracket
Post Bracket
3/8" Lock Washer
Post Bracket Assembly
3/8" Washer
Determining The Mounting Position of The Post Bracket Assembly
Swinging gates shall not open into public access areas!
A "Push-to-Open" gate opens out from the property.
A Push-to-Open Bracket is required for this type of installation (see Accessory Catalog). If you have a pull-to-open gate (gate opens into the
property), return to page 13; step 3.
In a PUSH-TO-OPEN installation the operators are installed while the gates are in the closed position.
Step 1
With the gates closed, adjust the post bracket assembly and the gate bracket until the operator is level. While holding the operator level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate.
IMPORTANT: While determining the mounting point for the post
pivot bracket assembly be sure that the position allows for maximum clearance between the gate and the operator in both the open and closed positions, as shown in the diagrams below. This clearance will give the operator the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area.
Step 2
After verifying that you have the best position for the post pivot bracket, insert the 5/16" x 1 3/4"
bolt through the aligned holes of the post bracket and post pivot bracket and fasten it with the 5/16"
washer and nut.
IMPORTANT: If you loosened the clamp on the post bracket to achieve the optimum position, tighten it in its new position and recheck the gate bracket with the gate in the open position (move the gate bracket and re-clamp it if necessary).
31
Page 36
1 2 3 4
ON DI P
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIM IT
S3
S4
S2
PULL
OFF OFF
ON ON PUSH SIMULT.
ON ON
120 MIN M AX
Learn Master Limit
Button
ON
OFF
DIP#3 ON Push-to-open operation. OFF Pull-to-open operation (factory setting).
1
ON DIP
2 3 4
1 2 3 4
ON
OFF
SOFT S TART OF F
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
ONONPUSH
SIMULT.
ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
1 2 3 4
N
F
F
FT
S
TART
O
F
F
LV
O
PEN DLY
.
N
N
U
S
H
IM
U
LT
.
2
0
MI
N
A
X
T
O
C
L
OS
E TIME
1 2 3 4
ON DIP
OFF
OFF
ONONPUS
SIMUONON
120 MIN
Push to Open Installation
Step 4
Make sure the control box power switch is OFF. Use a small screwdriver to move the Number 3 DIP switch from the factory setting (OFF / Pull-To­Open) to ON for Push-To-Open. Turn power switch ON. The control board is now configured to push the gate open.
Setting the Open Position Limit
Step 1
Confirm that the power switch is in the ON position, and the gate is in the CLOSED POSITION.
Step 2
Activate your opener by pressing the entry transmitter button. Your gate should now be moving from the closed position toward the open position. Prepare to STOP gate by pressing the entry transmitter button again when the gate reaches the desired open position. This step may be repeated until desired open position is achieved. Once the desired OPEN position has been achieved, proceed to Step 3.
Step 3
With the gate in the desired open position PRESS & HOLD the “LEARN MAST LIMIT" button on the control board for 5 seconds.
Step 4
Press the transmitter button and allow the gate to return to the closed position. YOUR GATE’S OPEN POSITION LIMIT IS NOW PROGRAMMED.
TESTING YOUR OPEN LIMIT SETTING:
Press your entry transmitter and allow your gate to open. If the OPEN position is not correct or needs to be changed, you will need to CLEAR your OPEN LIMIT settings and follow steps one (1) to four (4) again.
CLEARING PROGRAMMED OPEN LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to the fully closed position, then press and hold the "LEARN MAST LIMIT" button for 5 seconds. This will clear the memory for the open limit position. Follow steps one (1) to four (4) again.
32
Page 37
Maintenance & Troubleshooting Guide
If your gate opener does not function properly after it is installed, use this guide before calling the GTO Service Department.
‘PR03040-G3’ DIAGNOSTIC INDICATORS GUIDE
This guide provides detail explanations of various alarm sound and led indicators for the new PRO3040­G3 board).
A. LED INDICATORS ON WORKING OPENER:
In the following modes, the control boards will indicate various conditions of the operator. The operator is fully operational in these modes.
1. Input Changed indicators: Alarm: None. ‘STATUS’ Led: 1 blink.
• Whenever there is a change in state in any of the following inputs: retracted limit switch, DIP- Switches, Cycle, Safety, Exit, Shadow, Close Edge or Open Edge.
2. ‘CYCLE’ Input Activated indicators: Alarm: None. ‘STATUS’ Led: 1 blink with 2 seconds pause (Idle state only)
• ‘CYCLE’ input is continuously shorted to common/ground.
3. ‘SAFETY’ Input Activated indicators: Alarm: None. ‘STATUS’ Led: 2 blinks with 2 seconds pause (Idle state only)
• ‘SAFETY’ input is continuously shorted to common/ground.
4. ‘EXIT’ Input Activated indicators: Alarm: None. ‘STATUS’ Led: 3 blinks with 2 seconds pause (Idle state only)
• ‘EXIT’ input is continuously shorted to common/ground.
5. ‘SHADOW’ Input Activated indicators: Alarm: None. ‘STATUS’ Led: 4 blinks with 2 seconds pause (Idle state only)
• ‘SHADOW’ loop input is continuously shorted to common/ground.
6. ‘CLOSE EDGE’ Input Activated indicators: Alarm: None. ‘STATUS’ Led: 5 blinks with 2 seconds pause (Idle state only)
• ‘CLS EDGE’ input is continuously shorted to common/ground.
7. ‘OPEN EDGE’ Input Activated indicators: Alarm: None. ‘STATUS’ Led: 6 blinks with 2 seconds pause (Idle state only)
• ‘OPN EDGE’ input is continuously shorted to common/ground.
8. ‘POWER IN’ Input indicator: Alarm: None. ‘POWER IN’ Led (Green): ON/OFF (see description below)
• ON: Transformer is detected.
• OFF: Transformer installation: No AC input power is present. The battery is not being charged...
33
Page 38
9. Battery charging indicator: Alarm: None. ‘CHARGING’ Led (Red): vary (see description below)
• Constantly ON: The charging circuit is in fast charge mode. The battery is being charge with a constant current (~ 1Amp)
• 2 blinks per second: Soak charge mode. The charger has completed fast charge mode and the battery has reached the desired voltage (~14.1 Volts). The charger circuit will remain at this stage for a maximum of 2 hours then switch to float charge mode.
• 1 blink per 2 seconds: Float charge mode. The battery has reached full capacity; a constant volt age is applied to keep the battery at fully charged capacity. (~13.8 Volts)
• OFF: Battery is not being charge. This led will be OFF if there is no transformer or solar panel power.
10. Low Battery indicators: Alarm: 1 beep every 10 seconds (Idle state only) ‘STATUS’ Led: 1 blink every 10 seconds (Idle state only) ‘CHARGING’ Led: Rapid pulses every second.
• Operator will continue to operator as normal. However, the battery will need to be charged. Low battery indicator will only be activated while gate is idle.
• While in idle state and the battery voltage drop below 11.4 volts (this voltage is temperature compensated) the unit will enter low battery indicator mode as described above. The operator will ‘exit’ low battery indicator mode when the voltage is above 12Volts.
11. Receiver/RF indicators: Alarm: None ‘RECEIVER’ Led: blinking or OFF.
• When the ‘RECEIVER’ led is blinking, the controller is receiving ‘GTO scheme’ 318 MHz signal from the receiver. This indicates that the transmitter and receiver are working properly. However, if the transmitter is not being pressed and the ‘RECEIVER’ led is blinking, this indicates that there is significant interference (i.e. A stuck transmitter sending out unwanted signal).
• The ‘RECEIVER’ led is normally off if the transmitter is not pressed/transmitting.
B. LED INDICATORS ON NON-WORKING OPENER:
In the following modes, the operator is not functional. Power-on reset is required to return the operator to normal operation after the problem has been corrected.
1. Master arm limit switch error indicators: Error Code ‘1’ Alarm: 1 beep with 2 seconds pause. ‘STATUS’ Led: 1 blink with 2 seconds pause.
• The limit switch from the master arm is not detected. This typically indicates that the master arm is not connected or both the normally open (brown wire) and the normally close (orange wire) are shorted to common/ground.
2. Slave arm limit switch error indicators: Error Code ‘2’ Alarm: 2 beeps with 2 seconds pause. ‘STATUS’ Led: 2 blinks with 2 seconds pause.
• The limit switch from the slave arm is not detected. This typically indicates that both the nor mally open (brown wire) and the normally close (orange wire) are shorted to common/ground. Note: If no slave arm is connected, the control board will automatically switch to single mode operation.
• After 2 seconds of extending and the retracted limit switch still being activated (Stuck limit switch).
34
Page 39
3. Master arm running error indicators: Error Code ‘3’ Alarm: 3 beeps with 2 seconds pause. ‘STATUS’ Led: 3 blinks with 2 seconds pause.
• No pulses are detected from the master arm rev counter input during the first 1-2 seconds of running the gate.
• After 2 seconds of extending and the retracted limit switch still being activated (Stuck limit switch).
4. Slave arm running error indicators: Error Code ‘4’ Alarm: 4 beeps with 2 seconds pause. ‘STATUS’ Led: 4 blinks with 2 seconds pause.
• No pulses are detected from the slave arm rev counter input during the first 1-2 seconds of run ning the gate.
• After 2 seconds of extending and the retracted limit switch still being activated (Stuck limit switch).
5. Current Sensing (Obstruction) error indicators: Error Code ‘5’ Alarm: 5 beeps with 2 seconds pause. ‘STATUS’ Led: 5 blinks with 2 seconds pause.
• Current sensing circuit for detecting obstruction is not working properly. The current sensing circuit is tested prior to running the motor.
6. Board have NOT been tested (and passed QA): Error Code ‘25’ Alarm: 2 beeps then 5 beeps with 2 seconds pause. ‘STATUS’ Led: 2 blinks then 5 blinks with 2 seconds pause.
• The board has not been tested and/or have not passed QA test.
7. Master Motor Terminals Shorted: Error Code ‘12’ Alarm: 1 beep then 2 beeps with 2 seconds pause. ‘STATUS’ Led: 1 blink then 2 blinks with 2 seconds pause.
• The master motor terminals and/or leads are shorted.
8. Slave Motor Terminals Shorted: Error Code ‘13’ Alarm: 1 beep then 3 beeps with 2 seconds pause. ‘STATUS’ Led: 1 blink then 3 blinks with 2 seconds pause.
• The master motor terminals and/or leads are shorted.
35
Page 40
VOLTAGE RATINGS
PROFESSIONAL ACCESS SYSTEMS
®
18 Vac Transformer ___________________________ 18.0 to 22.0 Vac
5 W Solar panel (single) _______________________18.0 to 22.0 Vdc 300 mA measure voltage at panel and control box.
12 V Battery ________________________________12.0 to 13.5 Vdc 7.0 Ah
Charging circuit _____________________________12.0 to 14.8 Vdc measure voltage with battery connected
Repair Service
If your GTO/PRO® 2000XL Gate Opener is not operating properly, please follow the steps below:
1. First use the procedures found in the Troubleshooting Guide (see page 33).
2. If you are unable to solve the problem, call the GTO/PRO Service Department at (800) 543-1236, or (850) 575-4144. Refer to the serial number (located on the right hand side of the control box) and date of purchase when calling for assistance.
3. If repair or replacement of your gate opener is necessary, the Service Department will assign a Return Goods Authorization (RGA) number to you for warranty repair.
4. Securely pack the component(s) authorized for return to the factory. Include a copy of proof of purchase. Write the RGA number issued to you on the outside of the package in LARGE BOLD PRINT. Ship the package(s) freight prepaid to: GTO/PRO, 3121 Hartsfield Road, Tallahassee, Florida, USA 32303.
NOTE: Products returned to GTO/PRO without a Return Goods Authorization (RGA) number in LARGE BOLD PRINT on the outside of the package WILL NOT be accepted. Also, items returned to GTO/PRO
The GTO, Inc. Technical Service Department is open
Monday – Friday 8:00 A.M. – 7:00 P.M. (Eastern Time)
Telephone (800) 543-1236 Telephone (850) 575-4144
Fax (850) 575-8950 • Web site: www.gtopro.com
E-Mail: techsupport@gtoinc.com
36
Page 41
ACCESSORIES
®
AUTOMATIC G
ATE
L
OCK
®
ELECTRONIC SECURITY L
OCK
1
2
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PRS
8
TUV
9
WXY
0
POW
E
R
K
e
y
p
a
d
B
a
t
t Lo
w
Gran
t
Pe
rm
i
ssio
n
An
s
w
er
D
V
9V
A
CC
ES
S CONTR
OL
S
YS
T
E
MS
1-
80
0
-5
4
3
-
4
2
8
3
Solar Panel (FM123), (FM122)
The Solar Panel is a 10 watt solar powered battery charger for use with the all GTO/PRO DC gate operator systems. Particularly suited for remote installations, each Solar Panel comes with tubular steel support, mounting clips, wire connectors, and 8 ft. of low voltage wire (see Low Voltage Wire for additional wire). The GTO/PRO® control board has clearly labeled terminal connections for easy installation of the Solar Panel. Installation in some regions of the world will require multiple solar
panels for adequate charging power. Solar Panel (FM122) is a 5 watt solar powered battery
charger with all the same features as (FM123).
Push Button Control (RB101)
Unlit doorbell button for remote entry or exit control. Wires directly to the control board and uses 16 gauge multi-stranded, dual conductor low voltage wire (sold separately).
Pin Lock (FM345)
The Pin Lock substitutes for the clevis pin at the front end of the GTO/PRO® 2000XL gate operator. Helps prevent theft of the operator from the gate, while allowing quick release of the operator.
Key Chain Two Button Transmitter (RB742)
The Key Chain Mini Transmitter is a miniature version of the GTO/PRO® entry transmitter and has the same adjustable code settings. 12 Volt battery included.
Single Button Transmitter (RB741) The GTO/PRO® entry transmitter, with adjustable code settings, is standard equipment with all GTO/PRO® systems. 12 Volt battery included.
Digital Keypad (F310)
The specially designed digital keypad can be easily installed as a wireless or wired keypad. It can be programmed to use up to 25 different personal identification number (PIN) codes. Each code is face programmable with additional security features built in. Wired installations require 16 gauge, low voltage, multi-stranded, dual conductor, direct burial wire (sold separately). Requires 3 AA batteries
(not included).
GTO/PRO 50' Exit Wand (FM139), 100' Exit Wand (FM140), 150' Exit Wand (FM141)
The GTO/PRO® Exit Wand is designed for residential and agricultural applications and is compatible with all GTO/PRO® automatic gate operator models. The wand is an electromagnetic sensor, which offers 'hands free' operation of the GTO/PRO® Gate Operators with a 12 ft. radius of detection of vehicles in motion.
Automatic Gate Lock Pull-to-Open (FM144)
A MUST for added security. Solenoid driven, with a steel housing. Unlocks and locks automatically as gates open and close. Used with GTO/PRO® DC swing gate operating systems for maximum stability and security. Comes with a keyed manual release. Recommended for gates over 8 ft. long. Ideal for animal enclosures or high wind areas.
Wireless Entry Intercom / Keypad (F3100MBC)
Allows owner to screen guest at the gate before allowing access to the property. Keypad also allows owner to give up to 25 programmable entry codes to family, friends or approved delivery personnel. Codes can be permanent of temporary. Can be wireless up to 500 feet or hard wired up to 1000 feet.
37
Page 42
ACCESSORIES
HEDDOLF
UNIVERSAL
RECEIVER
MODEL 294
Replacement Battery (RB500)
Standard 12 volt, 7.0 amp-hour, maintenance-free battery for the GTO/PRO® 2500, GTO/PRO® 2000XL, GTO/PRO® 3000, GTO/PRO® 4000 gate operator systems. This is the only battery approved for use with the GTO/PRO® gate operator systems. Life expectancy is 3-5 years.
Low Voltage Wire (RB509)
The 16 gauge, multi-stranded, dual conductor Low Voltage Wire is for connecting the AC powered transformer, or the Solar Panel to the control board. Also used for the connection of accessories, such as locks, keypads, push buttons and other wired control devices. This specially designed wire is UV treated, PVC coated and ready for direct burial. Available in 1000' rolls or special lengths.
Push to Open Bracket (347 IH)
Required when GTO/PRO® 2000XL gate operator(s) must push the gate open, such as on a sloping driveway or where space prevents gate(s) from opening inward (pulled open). Order two PTO brackets for conversion of a dual
swing gate installation.
Column Mount Lock Receiver (433IH)
For mounting the Automatic Gate Lock on brick columns, walls, or for other applications with limited space between gate and post.
Replacement Transformer (RB570)
Standard 18 volt AC transformer for maintaining the battery included with the GTO/PRO® 3200 gate operator. This is the only transformer approved for use with all UL325 GTO/PRO® gate operator systems.
Garage Door Receiver (RB709)
The Garage Door Receiver allows you to use the same GTO/PRO® entry transmitter (see Dual and Triple Transmitters) to operate your gate operator and your garage door operator. Compatible with most garage door operators.
If you have a question about GTO/PRO accessories
just call 1-800-543-GATE!
The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced,
downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by permission only. Copyright
GTO®, GTO/PRO®, Bulldog® are registered trademarks of GTO, Inc. Professional Access Systems™ is a trademark of GTO, Inc. and are the exclusive property of GTO, Inc. (“GTO”).
All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO.
infringement is a violation of federal law.
38
Loading...