GTCO Small Format Station Command User Manual

Creation Station 4 x 5 RS-232 Creation Station Pro 6 x 9 RS-232 Creation Station Pro 12 x 12 RS-232 Creation Station Pro 12 x 18 RS-232 Design Station 4 x 5 RS-232 Design Station Pro 12 x 12 RS-232 Design Station Pro 12 x 18 RS-232
11050 11090 11120 11180 35050 35120 35180
Products and Models covered by this document:
RS-232 unit powers up as: 19200 8 n 1 Format 20 with extended data enabled. Increment run mode. Out of proximity data enabled.
NOTE: All information contained in this document is proprietary. No copies can be made without the consent of GTCO CalComp by Turning Technologies.
Operating Modes
Run Mode: Digitizer outputs coordinate data continuously.
Increment Mode Filter: Puts a movement filter on data in any mode. The transducer must
move N counts before the data can be sent. Then both axis data are updated. If out of proximity data is enabled in increment mode, one data point may be sent on leaving proximity. Changes in button state and pressure will also generate an increment event.
Prompt Mode Modifier: Places the additional restriction on data transmission that the host must transmit a prompt character to the tablet for each data point output. All other rules of normal operation apply. The prompt character is “?”. Prompting is a feature, which operates in conjunction with any of the above standard modes.
Send Data Out of Proximity Mode Modifier: If this flag is set, coordinate data will be sent when it meets the output conditions in or out of the active area. Cordless units may not respond to button information until cursor is close to tablet.
NOTE: This command should be sent after the mode commands.
Send Data in Margin: If this flag is set, coordinate data point will be sent when it meets the output conditions in the active area or when in margins.
NOTE: Margins on some of the tablets are very small and are larger leaving the tablet than coming in.
Plug and Play
*.2+/- .035 SEC
DTR goes high and then within .165 sec to .235 sec CTS goes high. Then the tablet sends
the “plug and play” string at 1200 baud 7 data no parity 2 stop bits. The string could be “(^a$CAL0012\\TABLET\\xx X yy tablet cs) cr If” or similar. See plug and play spec for more
information.
Dtr cts wiggle
CTS should be high well before DTR is dropped (1/18). DTR low times should be at least one timer tick (1/18) long and no longer than two ticks. This wiggle does not work 100% compared to older products. It is the same as sending “ESC % C 1 N 8 1 cr” and “ESC % A 0 cr.Go to effect at *2. CTS should be low for at least one timer tick and DTR should be
high during this time. At time *3, the tablet will send “T” and for each time CTS is toggled, one more “T” will be sent. To get out of this mode, send the table “ESC % VR cr” for a hard reset or use the “ESC %A1” command.
Formats
20 Format AFT
Transducer Types
23 Format
Cursor Coding
Commands
DC1 (X ON) start transmission after a x off (SAME AS “ESC % A 1”). DC3 (X OFF) stop transmission on the next packet (SAME AS “ESC % A 0”). “?” is the prompt character.
9X00 Commands
NOTE: Commands should not be sent back to back. There should be an estimated .002 sec delay between commands (2 char at 9600). Also, do not send new commands after ( V p or VS) till they respond back.