Introduction
Setting Up
Components Connecting the Components
Digitizer Connections
Interface Module Connections
Display Module Connections
Optional PC Connections and Program Installation
Starting QuikRuler
Making Selections
Stylus
16-Button Cursor
4-Button Cursor
Configuring QuikRuler
Locating the Menu
Relocating the Menu at Start-Up
Relocating the Menu While Working with QuikRuler
If You Lose the Menu Location
Using the Configure Block
Setting Fractional Digits
Setting Tone Options
Selecting Your Language
Choosing the Decimal Point Character
Setting the Last Output Character
Setting Scale and Units
Identifying the Unit of Measure
Setting the Scale Manually
Setting the Scale Automatically
Setting the Counting Scale
Measurements
3
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
10
10
11
11
12
13
13
13
14
14
15
16
18
19
Table of Contents
QuikRuler 1
Page 2
QuikRuler 2
Measuring the Size of an Area
Area Shortcut
Adding or Subtracting Areas
Measuring the Length of a Perimeter
Counting Elements of Your Drawing
Measuring a Straight Segment
Measuring a Continuous Length
Adding or Subtracting Segments and Lengths
Using QuikRuler as a Calculator
Editing Data on the Display
Correcting Mistakes When Accumulating Measurements Clearing the Total Correcting Numeric Entries
Sending Data to Your PC
Messages
Radio and Television Interference
Appendix
Transducer Button Functions
Limited Warranty for the QuikRuler
19
20
20
21
21
22
23
23
24
25
25
26
26
26
28
29
31
31
32
Page 3
QuikRuler 3
Introduction
QuikRuler is a portable measuring system that is perfect for estimators, builders,
contractors, surveyors, scientists, planners, designers, appraisers and anyone else who
needs to take measurements from blueprints, maps, diagrams and other drawings.
With QuikRuler, you can quickly measure areas, perimeters and lengths using any scale and
unit of measurement. Perform more complex measurements by adding or subtracting
areas and lengths. A built-in measurement system, combined with QuikRuler’s calculator,
make the measuring module an indispensable tool. And with the optional PC interface, you
can send results directly from the QuikRuler display to your PC, for use in a spreadsheet or
estimating package.
Best of all, you do not need any special training or experience to use QuikRuler. Simply
select an option from the QuikRuler menu, touch the stylus or cursor to the drawing and
view the results on the QuikRuler display.
Page 4
QuikRuler 4
Setting Up
Components
QuikRuler combines a digitizer, stylus or cursor and portable display into a single system
that is easy to move and set up as needed.
Page 5
Connecting the Components
Connect the stylus (or optional cursor) to the digitizer.
Attach QuikRuler interface module to the digitizer.
Attach the QuikRuler display module to the interface module.
Connect the power cable to the interface module.
Digitizer Connections
QuikRuler 5
Interface Module Connections
Page 6
Display Module Connections
Optional PC Connections and Program Installation
QuikRuler 6
To use QuikRuler with a PC, you must attach the interface module to an available PC serial
port and install the QuikRuler interface program.
Insert the QuikRuler disk into drive A (or B).
Type a:install (or b:install) at the DOS prompt and press ENTER.
Follow the instructions on your screen.
Starting QuikRuler
QuikRuler starts up when you connect the power supply. If the start-up was successful,
you should hear four short beeps from the digitizer and after the sign-on messages, line 1
of the display should read “Select from Menu.” Line 2 of the display will show the current
X-axis and Y-axis position of the stylus and a number indicating the status of the stylus
Page 7
QuikRuler 7
switches. If the stylus is over the menu, the numbers will be replaced by minus signs
(- -----,-----) or, if the stylus is not in the tablet’s measuring area, the numbers will be
replaced by asterisks (* *****,*****). Press the tip of the stylus on a menu function
button to begin using QuikRuler.
Making Selections
Use either a stylus or a cursor to trace and measure drawings. You can also implement
either device to make selections from the QuikRuler menu. This manual assumes you have
a stylus.
Stylus
16-Button Cursor
Page 8
4-Button Cursor
QuikRuler 8
Configuring QuikRuler
Locating the Menu
Use the QuikRuler menu to select functions you want to use.
Page 9
QuikRuler 9
When QuikRuler is shipped to you, it is programmed to expect the menu to be in the lower
left corner of the digitizer surface.
Relocating the Menu at Start-Up
When you start QuikRuler, it shows the following message for five seconds.
If you want the menu to be in a different location, you can relocate it when you start
QuikRuler.
Select a place for the menu and tape it down. The entire menu must be within the
digitizer’s measuring area.
Power up QuikRuler.
Press the stylus tip anywhere when the Relocate Menu message is displayed.
QuikRuler prompts you to Select Left Pnt.
Page 10
Press the stylus on the left point of the menu.
QuikRuler prompts you to Select Right Pnt.
Press the stylus on the right point of the menu.
QuikRuler 10
Relocating the Menu while Working with QuikRuler
You can change the location of the menu at any time while working with QuikRuler.
Select
Choose a place the menu and tape it down.
QuikRuler prompts you to Select Left Pnt.
Press the stylus on the left point of the menu.
QuikRuler prompts you to Select Right Pnt.
Press the stylus on the right point of the menu.
See the previous page for an illustration of the left and right menu points.
If You Lose the Menu Location
Tape the menu down where you want it to be.
Disconnect the power supply.
Reconnect the power supply and listen for four beeps.
Page 11
QuikRuler 11
When QuikRuler displays press the stylus tip anywhere to
enter the relocate mode.
Follow the prompts that QuikRuler shows you to select the left and right points. See
the previous sections for details.
Using the Configure Block
QuikRuler offers a number of user preference settings.
Select
QuikRuler displays a preference option and its current setting.
Choose repeatedly or use and until you see the option you
want to change. The Configure options include:
Digits Rt of ‘.’
Select Tones
Select Language
Decimal Pnt Char
Last Character
Use and to change the current setting of the displayed option. See the
following sections for details on each option.
Setting Fractional Digits
QuikRuler displays 0 to 8 digits to the right of the decimal point.
Select
Choose repeatedly or use and until Digits Rt of ‘.’ is displayed
on line 1.
Page 12
QuikRuler 12
The current number of digits setting is displayed on line 2 beneath the flashing
cursor.
Change the current setting by selecting a number from to on the
QuikRuler Menu.
Select or choose another option or function.
Setting Tone Options
QuikRuler can sound a tone when you make a selection from the QuikRuler Menu, or when
you press the stylus tip on the digitizer surface, or both. You can opt to turn off the tones
entirely.
Select
Choose repeatedly or use and until Select Tones is displayed
on line 1.
The currently selected tone option is displayed on line 2.
Use and repeatedly until you see the tone setting that you want to use:
Digits Rt of ‘.’
Select Tones
Select Language
Decimal Pnt Char
Last Character
Select or choose another option or function.
Page 13
Selecting Your Language
Select
Choose repeatedly or use and until Select Language is
displayed on line 1.
The currently selected language is displayed on line 2.
Use and repeatedly until you see the language that you want to use.
Select or choose another option or function.
QuikRuler 13
Choosing the Decimal Point Character
QuikRuler can display either a “.” or a “,” as the decimal point when numeric values are
displayed.
Select
Choose repeatedly or use and until Decimal Pnt Char is
displayed on line 1.
The currently selected character is followed by the flashing cursor on line 2.
Use and to move the cursor to the character that you want to use.
Select or choose another option or function.
Setting the Last Output Character
When is selected, line 2 of the display is sent to the computer, only if a numeric
value is displayed. The line 2 value is terminated by the character selected in this option.
Select
Page 14
QuikRuler 14
Choose repeatedly or use and until Last Character is
displayed on line 1.
The currently selected last character is displayed on line 2.
Use and repeatedly until you see the last character that you want to use:
Enter
Tab
Down Arrow <>
Right Arrow <>
Select or choose another option or function.
Setting Scale and Units
Use the and functions to tell QuikRuler the scale of the drawing you
are measuring and the units in which you want measurements to be displayed.
Identifying the Unit of Measure
Use the function to identify the units in which you want measurements to be
displayed. (See the next sections for details about setting the scale of measurements.)
For example, suppose you are working with a map where 1 centimeter represents 3
kilometers. You would first use to tell QuikRuler to measure your drawing in
centimeters and display the result in kilometers. Next, you would use to set a
1:3 scale.
NOTE: You can also choose at any time to convert the current measurement,
shown on the second line of the display, to a different unit of measure.
Page 15
To set the units:
mm
cm
m
km
in
ft
yd
mi
Choose
QuikRuler displays:
Measured (cm)
Displayed (km)
where, from the previous example, centimeters are the units you want to measure
from your drawing and kilometers are the units you want to display. The flashing
cursor follows the unit that may be changed.
QuikRuler 15
Select repeatedly or use and until you see the units you want
to use:
Choose or select another function.
Setting the Scale Manually
If you know the scale of the drawing you are working with, you can enter the measurement
scale manually.
Use the to select the unit of measure for the first part of the scale. For
example, if 1 centimeter equals 3 kilometers, select cm as the unit of measure and
km as the displayed unit. For more information, see “Setting Units” earlier.
Select
Page 16
QuikRuler 16
QuikRuler displays Scale cm: km on line 1, where cm is the current unit of measure
and km is the current displayed unit as selected in the function.
QuikRuler displays the current scale setting on line 2. For example, if the current
scale is 1 cm = 3 km, QuikRuler displays 1:3 on line 2 with the flashing cursor
positioned over the 3.
Change the scale by clicking on a number on the QuikRuler menu. For example,
click on if the desired scale is 1 cm = 5 km.
When the drawing scale is larger than 1:1, use a decimal value. If the scale were 5:1,
you would divide both sides of the ratio by 5 and click on the buttons so
the scale reads 1:2.
If the drawing scale is given as 1/8 in = 1 ft., for example, multiply both sides of the
equation by 8 so that 1 in = 8 ft. and select so that the QuikRuler scale reads
1:8.
Select or choose another function.
Setting the Scale Automatically
On maps and many other types of drawings, a scale diagram can be found in the drawing’s
legend. You can use this type of diagram to set the measurement scale automatically.
Simply mark the starting and ending points of the legend and tell QuikRuler the distance
between the two points.
On other drawings, you can set the scale automatically using a straight surface in the
drawing that is of a known length. Simply mark the starting and ending points of the
surface and tell QuikRuler the distance between the two points.
Page 17
QuikRuler 17
Select
Follow the prompts that QuikRuler displays to select the starting and ending scale
points.
For example, using the illustration of the map legend shown below, you would
select the point just below 0 as the starting point and the point just below the 4 as
the ending point.
Page 18
QuikRuler 18
QuikRuler prompts you for Distance (units).
Use the number buttons on the QuikRuler menu to tell the device the distance
between the two points you selected. Referring to the map legend above, you
would select to tell QuikRuler that the distance between the two points is 4
kilometers.
NOTE: You must first use the function to specify that your measured values are
in centimeters and displayed values are in kilometers. See “Identifying the Unit of Measure” earlier.
Choose or select another function.
To view the current auto scale setting, choose.
Setting the Counting Scale
You can use QuikRuler’s function to count areas or other components on your
drawing. For example, if you are using QuikRuler to estimate how much electrical wiring
will be required for a building, you could use the function to count how many
electrical outlets will be needed. Normally, QuikRuler counts by ones. However, you can
change the scale to something else using the function. For example, you can
use the function to tell QuikRuler to count by fives, tens or some other value –
even fractions.
To change the counting scale:
Select
QuikRuler displays the current counting scale under the flashing cursor.
Page 19
QuikRuler 19
Choose the appropriate number on the QuikRuler menu.
For example, select if you want to count my tens.
Choose or select another function.
Measurements
The following sections describe how to use QuikRuler to measure components of your
drawing.
Measuring the Size of an Area
QuikRuler can instantly calculate the size of an area on your drawing. Follow these steps:
Select
Press the stylus down on the outer edge of the area you want to measure.
While still holding the stylus tip down, trace around the perimeter of the area with
the stylus.
Lift the stylus tip when you have finished tracing the area.
QuikRuler III displays the size of the area in the units you specified.
Page 20
QuikRuler 20
Area Shortcut
If the area you are measuring contains straight edges, you can use a shortcut when
calculating the size of the area:
Trace the curved portion of the area by pressing the stylus tip down and following
the area’s perimeter.
When you reach a straight edge, lift the stylus tip at one end of the edge and press it
back down at the other end.
Adding or Subtracting Areas
After calculating the size of an area, you can add or subtract another area from it. For
example, suppose you are estimating the amount of paving material that will be needed for
a parking lot. You would first measure the size of the entire lot, and then subtract the sizes
of the areas within the lot that will not be paved.
Page 21
Follow these steps to add or subtract areas:
Measure the entire area, as described in the previous sections.
QuikRuler 21
Select or
Measure the area to be added to or subtracted from the first area.
If necessary, repeat the previous two steps to add or subtract additional areas.
Click on the button to calculate the total.
Measuring the Length of a Perimeter
QuikRuler can instantly calculate the length of an area’s perimeter. After measuring an
area:
Select to display the length of the area’s perimeter.
NOTE: Only the perimeter of the most recently measured area is displayed. Perimeters of
multiple areas are not summed unless the areas are measured in mode.
Counting the Elements of Your Drawing
Use the function to count the elements of your drawing, such as rooms, or
walls, or electrical outlets. You can count at any time, even while you are using another
function.
Follow these steps:
Page 22
QuikRuler 22
Use the function to tell QuikRuler the counting scale. For example, you
might want to count by ones, fives, tens or some other unit. See “Setting the
Counting Scale” earlier for more information.
Select
QuikRuler displays the current count.
To count, select any point on the digitizer surface.
Or, if you are not in the mode, press the side button on your stylus.
Measuring a Straight Segment
Use the function to measure the length of a straight segment. Follow these
steps:
Select
Follow the prompts that QuikRuler displays to select the starting and ending points
of the segment.
QuikRuler III displays the length of the segment.
To measure another segment, select its starting and ending points. You do not
have to press first.
EACH SEGMENT IS AUTOMATICALLY SUMMED WITH PREVIOUS SEGMENTS.
To start a new sum, press.
Page 23
Measuring a Continuous Length
Use the function to measure a curved length. Follow these steps:
Select
Choose the starting point of the length.
While holding the stylus down, trace along the length until you reach the ending
point.
Lift the stylus tip.
QuikRuler III displays the length of the line.
QuikRuler 23
If the segment is a straight line, you can measure it in a similar way to the Length
Segment function. Select the starting point of the line and then pick the stylus
up and choose the ending point.
Adding or Subtracting Lengths
To add or subtract lengths, follow these steps:
Measure the first length.
Press or
Measure the next length.
If necessary, repeat the previous two steps to add or subtract additional lengths.
Page 24
Click on the button to display the length total.
QuikRuler 24
Using QuikRuler as a Calculator
You can use the arithmetic operations and the numeric keypad buttons on the QuikRuler
menu to perform calculator functions.
You can use the calculator to transform your measurements in various ways. For example,
suppose you are using a drawing to estimate the amount of carpeting that will be required
Page 25
QuikRuler 25
for an entire floor of an office building. You want to add 5 percent to the measurement, to
account for waste, mistakes and so on. You would follow these steps:
Measure the area where carpeting is required.
Click on the buttons.
Select the button to display the total.
You can also use the menu as a traditional calculator to add, subtract, multiply and divide
numbers independently of your measurements. You can do this at any time, even while
using QuikRuler functions.
Editing Data on the Display
QuikRuler provides several ways of editing and correcting the data on the display.
Correcting Mistakes When Accumulating Measurements
When you are accumulating measurements for areas and lengths, use the
function to clear the current measurement. In addition, you can use this function to
correct mistakes made while accumulating measurements.
Follow the steps below when you need to fix a mistake that occurred while you were
adding the measurements of several areas. You can use the same procedure to fix
mistakes made while accumulating measurements for lengths.
Select to clear the area you are currently measuring from the QuikRuler
III display.
Choose
QuikRuler displays the size of the area you have already calculated.
Measure the next area and select to display the total if you are done.
Page 26
QuikRuler 26
Clearing the Total
You can clear the total that is on the second line of the display at any time. Click on the
button to clear the total.
Correcting Numeric Entries
When you are entering numbers, you can delete the last number you entered by clicking on
the button. It will delete the last digit you entered.
Sending Data to Your PC
You can use QuikRuler to send data directly from the display to your PC. QuikRuler can
send data to any program running under Windows or DOS.
Page 27
QuikRuler 27
To use QuikRuler with a PC:
On your PC, make sure the cursor is at the location where you want to insert a
measurement from QuikRuler.
Select to send to the PC the number shown on the second line of the
QuikRuler display. It will be entered into your application program as if you had
typed the value from your keyboard.
To simplify data entry to your spreadsheet, use the Last Character option in the
function to set the character sent after the numeric value on line 2 of the
display. For example, if you want to enter a column of values, use the Down Arrow
<> as the last character. In many programs, this will enter the numeric value in a
cell and move to the cell below the entry, ready for the next value.
You can navigate in your PC application by selecting the cursor-movement buttons.
For example, select to move up one line or cell in your PC application.
Page 28
QuikRuler 28
Message Meaning
**No Digitizer**
QuikRuler is not attached to the digitizer. You must attach
it before you can proceed. If QuikRuler is attached, make
sure the digitizer is configured for 9600 baud with no
parity and an 8-bit word. On most GTCO CalComp by
Turning Technologies digitizers, this can be done by
selecting S01 on the SuperSet menu.
**Memory Failure**
The power on test detected a memory failure. QuikRuler
will attempt to continue normally with all operations, if
you click the stylus tip or cursor anywhere on the digitizer
surface.
**Bad Ref Point**
This message will appear during a Relocate Menu
operation when an incorrect lower left or lower right
reference point is entered. Make sure that the entire
menu is within the digitizer’s measuring area. Repeat the
Relocate Menu operation when this message appears.
**Menu Off Tablet**
This message will appear during a Relocate Menu
operation when the QuikRuler menu is not positioned
entirely within the digitizer’s measuring area. Move the
menu and repeat the Relocate Menu operation when this
message appears.
**Number Too Big**
The number on line 2 of the display is too large for
QuikRuler. Try changing units to reduce the number size
when this message appears.
Messages
QuikRuler displays a variety of messages as you use its functions. Most of the messages
are indicative of normal operation, such as prompts that instruct you how to perform the
next step in a process. Other messages can signal a problem.
If you receive any of these messages and the above suggestions do not correct the
problem, contact the GTCO CalComp by Turning Technologies Technical Support Team.
Page 29
QuikRuler 29
Radio and Television Interference
Radio and Television Interference in the United States
This equipment has been tested and found to comply with the limits of a Class B digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee the interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Reorient or coil cables.
Consult the dealer or an experienced Radio/TV technician for help.
NOTE: Any cables the user adds to the device must be shielded to be in compliance with
the FCC standards. Any unauthorized modification to this device could result in the
revocation of the end user’s authority to operate this device.
Bescheinigung des Herstellers/Importeurs
Heirmit wird bescheinigt, dass der/die/das
3036R
(Geraet, Typ, Bezeichnung)
im Uebereinstimmung mit den Bestimmungen der
Vfg 1046/1984
(Amtsblattverfuegung)
Funk-Entstort ist.
Page 30
QuikRuler 30
Der Deutschen Bundespost wurde das Inverkehrbringen dieses Geraetes angezeigt und die
Berechtigung zur Ueberpruefung der Serie auf Einhaltung der Bestimmungen eingeraumt.
GTCO CalComp, Inc.
(Name des Herstellers/Importeurs)
Dieses Geraet wurde einzeln sowohl als auch in einer Anlage, die einen normalen
Anwendungsfall nachbildet, auf die Einhaltung der Funkentstoerbestimmungen geprueft.
Es ist jodoch moeglich, dass die Funkentstoerbestimmungen unter unguenstigen
Umstaenden bei anderen Geraetekombinationen nicht eingehalten werden. Fuer die
Einhaltung der Funk-entstoerbestimmungen seiner gesamten Anlage, in der dieses Geraet
betrieben wird, ist der Betrieber verantwortlich.
Einhaltung mit betreffenden Bestimmungen kommt darauf an, dass geschirmte
Ausfuhrungen gebraucht werden. Fuer die beschaffung richtiger Ausfuhrungen ist der
Betrieber verantwirtlich.
Page 31
Appendix
Transducer Element
Function
Stylus
Tip switch
Side switch
Menu picking
Increment Count accumulator
4-Button Cursor
Yellow button
White button
Blue button
Green button
Menu picking
Increment Count accumulator
Clear
Send
16-Button Cursor
0 button
1 button
2 button
3 button
4 button
5 button
6 button
7 button
8 button
9 button
A button
B button
C button
D button
E button
F button
Menu picking
Menu picking
Menu picking
Menu picking
Increment Count accumulator
Clear
Relocate Menu
Send
Area
Length Segment
Length Continuous
Perimeter
Count Mode
Left Arrow
Right Arrow
Total (=)
Transducer Button Functions
QuikRuler 31
Page 32
QuikRuler 32
Limited Warranty for QuikRuler
GTCO CalComp by Turning Technologies, Inc. warrants these products to be free from defects in
material and workmanship under the following terms. Complete and return the enclosed warranty
registration card to ensure that your products are covered with this warranty.
Coverage
Parts and labor are warranted for two (2) years from the date of the first consumer purchase for the
digitizer tablet, controller, transducers and tablet accessories. Power supply and cables are also
warranted for one (1) year. This warranty applies to the original consumer purchaser only.
Within the European Union, the warranty period is two (2) years, as mandated by the EU. Contact
your local dealer or distributor for additional warranty information.
Warranty is only valid if original consumer’s purchase or lease date is less than or equal to six
months from the original GTCO CalComp by Turning Technologies sale date. This information will
be captured by the system serial number and confirmed by the reseller’s purchase order.
A nominal Warranty Handling Fee will be charged after the first 90 days of use and calculated from
the date of original consumer purchase. This payment may be made by Visa, MasterCard or
American Express. A copy of the sales receipt or invoice will be required for warranty verification.
Conditions
Except as specified below, this warranty covers all defects in material or workmanship in the
products. The following are not covered by the warranty:
1. Any product on which the serial number has been defaced, modified or removed (if
applicable).
2. Damage, deterioration or malfunction resulting from:
a. Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature,
unauthorized modification for any purpose, unauthorized product modification, or
failure to follow instructions supplied with the product.
b. Repair or attempted repair by anyone not authorized by GTCO CalComp by Turning
Technologies.
c. Any damage in shipment of the product (claims must be presented to the carrier).
d. Any other cause which does not relate to a manufacturing defect.
3. Any product not sold or leased to a consumer within six months of GTCO CALCOMP BY
TURNING TECHNOLOGIES original sale date.
GTCO CalComp by Turning Technologies will pay all labor and material expenses for covered items,
but will not pay for the following:
1. Removal or installation charges.
Page 33
QuikRuler 33
2. Costs for initial technical adjustments (set up), including adjustment of user controls.
3. Certain shipping charges. (Payment of shipping charges is discussed in the next section of
this warranty.)
4. Packaging costs. (Customers should keep their boxes.)
Warranty Service Procedures
1. To obtain service on your GTCO CalComp by Turning Technologies product, contact the
Technical Support Department to receive a Return Material Authorization Number (RMA#)
and shipping instructions by calling: 1-866-746-3015.
2. Ship the product to GTCO CalComp by Turning Technologies with the RMA# marked clearly
on the outside of the box. Without a clearly marked RMA# on the shipping box, GTCO
CalComp by Turning Technologies reserves the right to refuse the shipment.
3. Although you must pay any shipping charges to ship the product to GTCO CalComp by
Turning Technologies for warranty service, GTCO CalComp by Turning Technologies will pay
the return shipping charges for ground shipment. Other shipping options are available at an
additional fee.
4. Whenever warranty service is required, the original dated sales invoice (or a copy) must be
presented as proof of warranty coverage and should be included in shipment of the product.
Please also include your name, address, telephone number, fax number, email address and
a description of the problem.
5. If GTCO CalComp by Turning Technologies determines that the unit is not defective within
the terms of the warranty, the consumer shall pay the cost of all freight charges, as well as
any repair charges.
Technical Support
Web-based Technical Support is available free of charge at: www.gtcocalcomp.com, where current
driver releases, as well as comprehensive technical support, troubleshooting, Technical Bulletins and
FAQs can be found.
Telephone Technical Support is available free of charge to the original consumer for a period of 90
days from the date of purchase of the product. Please contact our Technical Support Department
at: 1-866-746-3015 or fax your request to: 480.998.1751.
Disclaimer of Unstated Warranties
The warranty printed above is the only warranty applicable to this purchase. ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. Assuming the
warranty above stated is otherwise applicable, it is expressly understood and agreed that GTCO
CalComp by Turning Technologies sole liability whether in contract, tort, under any warranty, in
negligence or other shall be for the repair or replacement of the defective parts and under no
circumstances shall GTCO CalComp by Turning Technologies be liable for special, indirect or
Page 34
QuikRuler 34
consequential damages. The price stated and paid for the equipment is a consideration in limiting
GTCO CalComp by Turning Technologies liability.
Notice
Some states and provinces do not allow the exclusion or limitation of incidental or consequential
damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights,
and you may have other rights, which vary from state to state, or province to province.
To obtain service on your GTCO CalComp by Turning Technologies product, call our Technical
Support Department at: 1-866-746-3015 or fax us at (480) 998-1751. We can also be contacted
through our website at www.gtcocalcomp.com (in US); at EUOffice@gtcocalcomp.com (in Germany);
at infos@calcomp.fr (in France).
Important!
All products returned to GTCO CalComp by Turning Technologies for service must have prior
approval in the form of a Return Merchandise Authorization Number (RMA#), which can be obtained
by calling the Technical Support Department.