![](/html/36/36a7/36a75879794215296ec4ad38e7a697c8f497c469d59d76763683571856903fcc/bg1.png)
PATROL – 801PET
PROFESSIONAL COMBINED
DIGITAL PIR & GLASS
BREAK DETECTOR
WITH PET IMMUNITY
INSTALLATION
INSTRUCTIONS
OC03
www.gsncompany.com
FEATURES.
• Immune to pets up to 30kg
• Digital mathematical algorithm
of signal processing
• High light immunity – no less
than 10000 Lux
• High RFI & EMI immunity
• Two optoelectronic switch relays
for glass break and PIR detectors
• Test mode for two acoustic channels
• Hermetically insulated PYRO sensor
• Automatic temperature compensation
• Pulse counter.
DESCRIPTION.
The PATROL-801PET is immune
to pets of up to 30kg and 1m height.
The PATROL-801PET is a combination
of PIR and acoustic glass break
detectors.
The PIR detector analyzes the
environment and detects the person's
motion crossing the infrared beam.
The acoustic glass break detector
identifies the sounds of glass impact
and breakage.
Due to unique program for processing
incoming signals from PIR and
GLASS BREAK detectors the
PATROL-801PET enables an
exceptionally reliable detection and
stable "false alarms free" operation in
extremely harsh environments.
ALGORITHM.
Unique algorithm is based on recognition
of sequence of low-frequency and
high-frequency signals of framed pane
glass breakage. Low-frequency signal
is emitted upon the impact of glass.
High-frequency signal occurs upon the
glass breakage.
HIGH FREQUENCY LOW FREQUENCY
SIGNAL SIGNAL
For creating an alarm, both a
low-frequency sound of the glass
impact and a high-frequency glass
breakage sound must be registered
within a predetermined time frame.
Since both detector channels must
register the actual glass breakage,
false alarms are practically excluded.
The program of microcontroller,
based on the mathematical algorithm,
analyzes signals and detects only the
actual breakage of all standard framed
glass types.
PROTECTED GLASS TYPES.
Glass
type
Min.
Thickness
Max.
Thickness
Plate 2 mm 10 mm
Tempered 3 mm 8.4 mm
Patterned 3 mm 10 mm
Laminated ¹ 3.2 mm 14.3 mm
Wired 5 mm 6.4 mm
Coated ²
(Triplex)
2.5 mm 8.4 mm
Sealed
Insulating ¹
3.2 mm 6.4 mm
¹ Laminated and sealed insulating
glass types are protected only
if both glass plates are broken.
² For glass coated with plastic film
on the inner surface, effective range
is reduced to 6m.
SELECTING MOUNTING
LOCATION.
Choose a location most likely to
intercept an intruder.
The recommended installation height
to gain maximum protection zone
is 2.1 - 2.3 meters.
For protecting several windows mount
the detector at optimal distance from
them. If heavy blinds of curtains cover
the glass, locate the detector so the
blinds will not block the sound.
void the following locations:
- Near sources of loud noises or
vibrations (heating/air conditioning
units, bells, fans, compressors, etc.)
- On the same wall as protected glass.
PET IMMUNITY SETTING.
Set the switch S2 according to
the animal weight.
10KG
20KG
30KG
S2
PULSE COUNTER.
Set the jumper W5 to the "1P" position
for premises with stable environment.
Set the jumper W5 to the "2P" position
for locations with harsh environment.
1P
W5
2P
![](/html/36/36a7/36a75879794215296ec4ad38e7a697c8f497c469d59d76763683571856903fcc/bg2.png)
TERMINAL BLOCK CONNECTION.
+ 12V - TAMPER RELAY 1 RELAY 2
Terminals “+12V-“ – for connection
to the power supply of the control unit.
Terminals “Tamper” – for connection
to a 24-hour normally closed protective
zone in the control unit.
Terminals “Relay 1” – relay output
of the PIR detector.
Terminals “Relay 2” – relay output
of the glass break detector.
SELECTING GLASS TYPE
AND COVERAGE RANGE.
Set the jumper W1 according to the
distance to the protected glass.
Set the jumper W2 according to the
protected glass type (see the figure).
TYPE
RANGE
W2
W1
GLASS
ADJUSTMENT
9M
12M
PL
TM
LW
6M
PL - PLATE
TM
- TEMPERED
LW- LAMINATED
- WIRED
- COATED
- SEALED INSULATING
- PATTERNED
(TRIPLEX)
*
TM position – for most glass types.
*
GLASS BREAK TEST.
NOTE!
Testing should be conducted when
the front cover of the detector is closed.
1. Set jumper W3 to “GLASS TEST”
position. The PIR detector is off; the
RELAY 1 and RELAY 2 are opened.
2. Replace the cover.
3. Use glass break simulator to simulate
the high frequency signal of the glass
breakage. The red LED will flash with
each simulator activation.
SHOCK & GLASS TEST
W3
GLASS TEST
OPERATING MODE
SHOCK & GLASS BREAK TEST.
1. Set the jumper W3 to
"SHOCK & GLASS TEST" position.
The PIR detector is off; the RELAY 1
is opened, the RELAY 2 is closed.
2. Replace the cover.
3. Tap gently the protected glass and
activate the glass break simulator at
the same time.
The red LED will be ON for 3 sec,
the RELAY 2 will open.
NOTE!
fter testing, set the jumper W3
to “OPERATING MODE” position.
The PIR and Glass Break detectors
are operating; the RELAY 1 and
RELAY 2 are closed.
CS
PATROL 801PET
GSN ELECTRONIC COMPANY LTD.
+ 12V TAMPER RELAY 1 RE LAY 2
GLASS
TYPE
RANGE
ADJUSTMENT
W2
W1
9m
12m
PL
TM
LW
6m
ON
OFF
PIR & GLASS
BREAK DETECTOR
W3
LED
GLASS TEST
SHOCK &
GLASS TEST
OPERATING
MODE
W5
2P
1P
10KG
20KG
30KG
S2
WIDE ANGLE LENS.
0
Вид сверху
Вид сбоку
90
o
15m
TECHNICAL SPECIFICATIONS.
Detection speed range:...0.3 – 3.0m/sec
Power input:……..………...8.5 – 16VDC
Current consumption
in stand-by mode:……………….18.4mA
In alarm mode
with LED on:……………….….…19.1mA
In alarm mode
with LED off:……………………. 14.4mA
Pulse mode:…………………………...1,2
Alarm period:..……………...………3 sec
Warm up period:……………...40 ± 2 sec
Reset time:……………………..5 ± 1 sec
Relay output:……..NC; 60V;120mA;16Ω
PIR detection
range:..………………………...15m x 90º
Glass break detection
range:……….……................12m x 160º
Light immunity no less than:…………….
………………………………..10000 LUX
Operating temperature
range:……………………– 30°C + 50°C
Storage temperature
range:……………………– 40°C + 80°C
RFI immunity:………………..30V/m at a
frequency range 10MHz-1000MHz
EMI immunity:…………………..50 000V
Dimensions:………………93x66x46mm
Weight:…………………………...….97gr.
WARRANTY.
GSN Electronic Company Ltd.
warrants the product to be free from
defects in materials and workmanship
under condition of observance of
service regulations and to be repaired
or replaced under absence of
mechanical damages for a limited
period of five years from the
date of sale.
PRINTED IN ISRAEL
P/N: USM0E801PET REV.A