GSL INV600-12, INV1500-24, INV600-24, INV1000-12, INV1500-12 Operating Instructions Manual

...
Unit 2, 110 Station Road, Seven Hills ,NSW, 2147, Australia
Features include:
• Low battery alarm • Low battery shut down • Input voltage (12V Models 10-16VDC) (24V Models 20-30VDC) • Input low voltage protection • Input high voltage protection • Input short circuit protection
• Output voltage 220~240VAC @ 50Hz • Output short circuit protection • Overload protection • Over­temperature protection via internal temperature controlled fan(s) • High efciency design 85-90% efcient • Bar graph displays for battery voltage & load levels (%) (INV1000, 1500, 2500 models) • LED displays, indicate power ON & shutdown modes (INV150, 350, 600 models)
• Aluminium construction heatsink
Safety Instructions Explosive Gas Precautions:
This equipment contains components that can produce arcs or sparks. To prevent re or explosion do not install in compartments containing batteries or ammable materials, or in locations that require ignition-protected equipment. This includes any space containing petrol-powered machinery, fuel tanks, joints or other connections between components of the fuel system.
Precautions When Working With Batteries:
• If battery acid contacts skin or clothing, wash immediately with soap and water. If acid gets into eyes, immediately ood eyes with running cold water for at least 20 minutes and get medical attention immediately. NEVER smoke, allow a spark or ame in the vicinity of batteries or engine. Do not drop a metal tool on the battery as the resulting spark or short-circuit of the battery may cause an explosion.
• Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery. A lead-acid battery produces a short circuit current, high enough to weld a ring or similar metal, causing a severe burn.
Operating Limits:
The inverter will operate most AC appliances within its power rating. When operating microwaves, please note that the power commonly advertised for microwave ovens is the cooking power (the power delivered to the food) not the power actually used by the microwave oven. Microwave ovens generally will consume 40% to 100% more than the advertised cooking power. Check the rating sticker at the rear or under the oven to determine its actual power draw.
In some cases the power inverter may not be able to start some electric motors even though the rated current draw is within the limits of the inverter. If a motor will not start, check the voltage reading of the battery voltage indicator. If the voltage indicator reads below 11.0 volts (19V on 24V models, this could be the reason for not starting. Check that the wire connections are good and that the battery is fully charged. If these are ok and you get the same, then this is indicative that the inverter is too small for the application.
Page 1of 4
Models:
INV600-12, INV600-24 INV1000-12, INV1500-24, INV1500-12, INV2500-24, INV2500-12
Modied Sine Wave
DC to 240VAC Power Inverters
12VD
Operating Instructions
Please read these instructions before use
INV12-24-ALL-R1
Unit 2, 110 Station Road, Seven Hills ,NSW, 2147, Australia
Controls and indicators:
1. ON/OFF Switch (all models):
The ON/OFF switch turns the control circuit in the power inverter on and off. It does not disconnect power from the power inverter. Always leave this switch in the off position before operating inverter.
2. Over temp LED indicator (all models): The over temp LED indicates that the power inverter has shut down because it has become overheated. The power inverter may overheat because it has been operated at power levels above it’s rating, or because it has been installed in a location, which does not allow it to dissipate heat properly. The power inverter will restart automatically once it has cooled off.
3. Overload LED indicator (all models): The overload LED indicates that the power inverter has shut itself down because its output circuit has been short-circuited or drastically overloaded. Switch the ON/OFF switch to OFF, correct the fault condition, and then switch the ON/OFF switch back to ON.
4. Input voltage display (INV1000/1500/2500 only): This bar graph displays the status of the input voltage from the supply source. Under normal operating conditions the bar graph should display in the green area. Should the voltage either increase or decrease the bar graph will display in the red areas and the unit will shut down.
5. AC Load display (INV1000/1500/ 2500 only):
This bar graph displays the AC power drawn from the power inverter. It indicates the load in Watts. Under normal operating conditions the bar graph should display in the green or orange bars of the display. If the load is excessive the number of bars being displayed will increase. Should all the bars illuminate, the unit will shut down to protect itself as this is in overload condition.
WARNING! Shock Hazard!
Before proceeding further, ensure that the Inverter is NOT connected to any Batteries, and that all wiring is disconnected from any electrical Sources. Do not connect the output Terminals of the Inverter to an incoming AC source.
Electrical Requirements:
Before installing your inverter, please make sure that you have appropriately sized batteries. A battery that is too small in capacity will not allow the inverter to perform to its full specication. The DC cabling must be connected to the correct polarity terminals of the battery bank. (Red = Positive, Black = Negative). DO NOT extend the DC cable length to the inverter unless you are prepared to increase the diameter of the cable. If this is necessary consult your supplier or installer for advice.
WARNING! Reverse polarity connection will blow the internal fuse and may damage the inverter permanently. Reverse polarity is not covered by warranty.
Page 2 of 4
Models:
INV600-12, INV600-24 INV1000-12, INV1500-24, INV1500-12, INV2500-24, INV2500-12
Modied Sine Wave
DC to 240VAC Power Inverters
12VD
Operating Instructions
Please read these instructions before use
INV12-24-ALL-R1