GS Instech GSTR TRIT SPR User Manual

FCC ID : U88GSTR-TRIT-SPR
ATTACHMENT E.
- USER MANUAL -
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 1/37
FCC ID : U88GSTR-TRIT-SPR
INFORMATION TO USER :
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
CAUTION
Changes or modifications not expressly approved
by the manufacturer responsible for compliance
could void the user's authority to operate the equipment
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 2/37
2
FCC ID : U88GSTR-TRIT-SPR
- INDEX -
1. SUMMARY .................................................................................................................4
2. SYSTEM CONFIGURATION.....................................................................................6
2.1 Tri-band repeater service network configuration ................................................6
2.2 System Design and Operation......................................................................................8
3. ELECTRIC MATERIAL AND SPECIFICATIONS...................................................14
3.1 System Capacity..............................................................................................................14
3.2 System Material & Mechanical Specifications......................................................15
3.3 Electrical Specifications................................................................................................15
3.4 Functions............................................................................................................................16
4. SET UP .....................................................................................................................18
4.1 System Set up...................................................................................................................18
4.2 Troubleshooting...............................................................................................................22
5. WEB USER INTERFACE .........................................................................................23
5.1 Common set up (PCS, IDEN) ......................................................................................23
5.2 PCS Web UI.......................................................................................................................24
5.3 IDEN Web UI.....................................................................................................................30
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 3/37
3
FCC ID : U88GSTR-TRIT-SPR

1. Summary

Tri-band In-building repeater is located in blanket / shadow area of insider of building to
transmit Sprint/Nextel CDMA (PCS), iDEN800MHz, iDEN900MHz BTS signal simultaneously.
Characteristics (CDMA)
CDMA (PCS) Band: 80dB Gain with +24dBm maximum output power
iDEN Band: 65dB Gain with +25dBmmaximum output power.
Bandwidth: Entire 1900MHz CDMA (PCS) frequency A Block to G Block (65MHz). Bandwidth
selection functions per user’s situation.
- 5MHz, 10MHz, 15MHz Block and contiguous 20MHz combination
- Three of non contiguous 5MHz block combination
- 10MHz, 15MHz Block could be divided by 5MHz-Sub block.
- Remote control via Web based user interface
Characteristics (iDEN 800MHz)
Bandwidth
- Downlink 851MHz~869MHz, Uplink 806MHz~824MHz (18MHz Band)
- Downlink 862MHz~869MHz, Uplink 817MHz~824MHz (7MHz Band)
To avoid paging signal interference at 940MHz side, IF Converter shift SAW filter edge by
200KHz, 400KHz. (TX Edge only, not whole bandwidth).
- IDEN800MHz, iDEN900MHz simultaneous service
- Remote selection either 18MHz or 7MHz
- Downlink band-edge adjustable (SAW Filter select)
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 4/37
4
FCC ID : U88GSTR-TRIT-SPR
Characteristics (Tri-Band)
Basically system box is two combination types of iDEN and CDMA technologies. Functional modules are classified as below.
- 6-Plex and Hybrid Multiplex Cavity Filter to combine HyCDMA (PCS), iDEN 800MHz, iDEN
900MHz, Duplex input/output signal.
- LNA(Low Noise Amplifier),
- Gain Block to transmit output signal to PAM (Power Amplifier Module).
- Donor LNA, Server LNA Module, which include Divider / combiner for IF Module interface.
- IF Converter Module (thee in CDMA side, one of each iDEN800MHz, iDEN900MHz side)
- PAM Module to amplify output power linearly in accordance with optimal repeater output
power.
- Power Supply Unit
- Controller to monitor each module in repeater.
All modules in Tri-Band repeater are commonly compatible with CDMA and iDEN standalone box.
Abbreviation
PAM: POWER AMPLIFIER MODULE
LNA: LOW NOISE AMPLIFIER
AGC: AUTO GAIN CONTROL
ALC: AUTO LIMIT CONTROL
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible.
Ethernet Instruction “ This equipment is indoor use and all the communication wirings are limited to inside of the building” or similar texts.
Replaceable batteries instruction CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECTIVE TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
5
Report No. : HCT-R07-020 5/37
FCC ID : U88GSTR-TRIT-SPR

2. System Configuration

2.1 Tri-band repeater service network configuration

The system’s operation range is from A Block to G Block (Total: 65MHz) and the system features
- to set up 20MHz using 5MHz, 10MHz, 15MHz and contiguous ‘Block’
- to set up 3 non-contiguous 5MHz Block
- to set up Sub Block by 5MHz with 10MHz, 15MHz Block
- Remote control through GUI
This system is to provide iDEN800MHz and 900MHz simultaneously.
Available band selection
a. 18MHz Band of Downlink 851MHz~869MHz, Uplink 806MHz~824MHz
b. 7MHz Band of Downlink 862MHz~869MHz, Uplink 817MHz~824MHz
can select the 18MHz Band of Downlink 851MHz~869MHz, Uplink 806MHz~824MHz and
Downlink 862MHz~869MHz, 7MHz Band of Uplink 817MHz~824MHz on remote control.
Also, high frequency edge in Downlink side could be reduced by 200 KHz or 400 KHz to
attenuate adjacent band signal
- Simultaneous service of IDEN800MHz, iDEN900MHz
- IDEN800MHz remote band selection either 18MHz/7MHz
Downlink band-edge shifting is available (SAW Filter select)
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 6/37
6
FCC ID : U88GSTR-TRIT-SPR
<Pic.1> Tri-band In-building Repeater Service organization
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
7
Report No. : HCT-R07-020 7/37
FCC ID : U88GSTR-TRIT-SPR

2.2 System Design and Operation

2.2.1 System design

NO. PART NO. PART
1 SERVICE CAVITY MODULE 12 iDEN FWD LAN MODULE
2 DONOR CAVITY MODULE 13 iDEN NMS& I’O BOARD MODULE
3 5M IF CONVERTER MODULE 14 US PCS NMS& I’O BOARD MODULE
4 18M IF CONVERTER MODULE 15 US PCS WAVE MONITORING MODULE
5 7M IF CONVERTER MODULE 16 US PCS FWD PAM
6 iDEN RVS LAN MODULE 17 US PCS RVS PAM
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
8
Report No. : HCT-R07-020 8/37
FCC ID : U88GSTR-TRIT-SPR
7 US PCS RVS LAN MODULE 18 iDEN WAVE MONITORING MODULE
8 20M IF CONVERTER MODULE 19 iDEN RVS PAM
9 15M IF CONVERTER MODULE 20 iDEN FWD PAM
10 10M IF CONVERTER MODULE 21 PSU MODULE
11 US PCS FWD LAN MODULE 22 HUB
<Pic.2> Tri-band In-building Repeater internal design
NO. PORT NO. PORT
1
2
3
4
5
SERVICE ANT PORT
iDEN DONOR ANT TERM
DONOR ANT TERM
CDMA DONOR ANT TERM
AC POWER PORT
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
6
7
8
9
DC POWER PORT
PCS MONITOR PORT
iDEN MONITOR PORT
ETHERNET HUB PORT
9
Report No. : HCT-R07-020 9/37
FCC ID : U88GSTR-TRIT-SPR
<Pic.3> iDEN 25dBm PORT design

2.2.2 Downlink Path

Tri-band In-building RF Repeater operates CDMA (PCS) and iDEN800MHz, iDEN900MHz. RF
Module shares the modules used for CDMA (PCS) equipment and iDEN equipment and have
differences in the configures of Donor ANT and Server ANT Port.
Tri-band In-building RF Repeater has separate 2 Donor ANT Port for aiming each BTS. Server
Port for indoor is possible to one port. Therefore, Cavity Filter applied to Front End of Donor
ANT Port consists of DPX for CDMA (PCS) and 4Plex for iDEN and Cavity Filter for Front End of
Server ANT Port has 6-Plex which multiplexes all TX/RX in one path.
<Pic.4> Tri-Band In-building Repeater Downlink Block Diagram

2.2.3 Uplink Path

GST designed to use all same modules, which are used to stand alone unit, in Tri-Band unit.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 10/37
10
FCC ID : U88GSTR-TRIT-SPR
<Pic.5> Tri-band In-building Repeater Uplink Block Diagram

2.2.4 Adjustable Band Edge functional circuit configuration

In case of IDEN using the bandwidth of 800MHz and 900MHz, many of Out of Band Signals is
input via Donor ANT Outdoor. The most worried signal among them is Paging Signal.
Commercial Paging Signal of 929MHz~932MHz, 940MHz~941MHz, having the strength of Max.
-15dBm, is to be inputted into Donor ANT. Among this two kind of Paging Signal Band,
929MHz~932MHz bandwidth is possible for sufficient Rejection via SAW Filter, But
940MHz~941MHz is difficult to gain big decreasing volume even if use SAW Filter because Band
Edge is as close as to be folded to 935MHz~940MHz of being the frequency of iDEN900MHz
Downlink.
To prepare for this environment, Down Link of iDEN Repeater is designed to have additional
Roll Off characteristic by decreasing band of SAW Filter in the station adjacent to paging signal,
for it having the function of Adjust Band Edge that can decrease c of high frequency by 200 kHz,
400 kHz each.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
11
Report No. : HCT-R07-020 11/37
FCC ID : U88GSTR-TRIT-SPR
<Pic.6> Achieving additional Roll Off via Adjust Band Edge

2.2.5 US PCS Frequency Selection

1930
1930
1850
1850
AB CDEF G
1945 1950 1965 1970 1975 1990 1995
1945 1950 1965 1970 1975 1990 1995
AB CDEF G
1865 1870 1885 1890 1895 1910 1915
1865 1870 1885 1890 1895 1910 1915
B CDEF GA
< Forward Band Structure >
< Forward Band Structure >
B CDEF GA
< Reverse Band Structure >
< Reverse Band Structure >
f (MHz)
f (MHz)
f (MHz)
f (MHz)
<Pic.7> PCS Band Structure
Setup of CDMA Block is formed by Switch and SAW Filter. If the operator set up the Block,
Controller select the path of SAW Filter for disconnection of Switch and select the Local
frequency to gain the preferable RF frequency modifying the data of PLL.
The following show a circuit diagram for Band Select of CDMA. CDMA operates 1 to 3 Blocks at
once using IF Converter Module containing the path of 2 SAW Filter in Downlink/ Uplink.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
12
Report No. : HCT-R07-020 12/37
FCC ID : U88GSTR-TRIT-SPR
Configure of IF Converter for CDMA Block
Configure for one 5MHz Block Configure for one 10MHz Block
Configure for one 15MHz Block Configure for continuous 20MHz Block
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
13
Report No. : HCT-R07-020 13/37
FCC ID : U88GSTR-TRIT-SPR
Configure of separated 20MHz Configure of 3 separated 5MHz

3. Electric Material and Specifications

3.1 System Capacity

Item
IDEN800
Down Link
Frequency
Up Link
Frequency
Port
Capacity OMNI
IDEN900 935MHz ~ 940MHz 5MHz
CDMA (PCS) 1930MHz ~ 1995MHz 65MHz
IDEN800
IDEN900 896MHz ~ 901MHz 5MHz
CDMA (PCS) 1850MHz ~ 1915MHz 65MHz
Donor 0 CDMA TX / RX Duplex
Donor 1 IDEN TX / RX 4-Plex
Server CDMA / IDEN TX / RX 6-Plex
Specification Remark
851MHz ~ 869MHz 18MHz
Select
862MHz ~ 869MHz 7MHz
806MHz ~ 824MHz 18MHz
Select
817MHz ~ 824MHz 7MHz
CDMA Channel Capacity
IDEN Select Bandwidth 18MHz / 7MHz IDEN800MHz
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 14/37
5MHz, 10MHz
15MHz, 20MHz
14
Can select three separated
block
Simultaneously
FCC ID : U88GSTR-TRIT-SPR
Output
+25dBm / 316mW
Composite
Power
(ANT Port)
iDEN
CDMA (PCS) +24dBm / 250mW

3.2 System Material & Mechanical Specifications

Item
RF Connector N-Type Female Donor & Server ANT Port
AC Power
Connector
DC
AC Supply AC 120V 60Hz 3.0A
Out Dimension 16.7*23*6.77 Inch
Net Weight 29.5 kg
Material Module AL6063S-T5
Cabinet AL5052P
Specification Remark
MS3102A-10SL (3Pin)
SCK-16-2P (2Pin)
+22dBm / 158mW
Per Single Band
MIL-C-5015 Type
Circular Type
Operation
-10 ~
Convection cooling
Tem pe ra tu re
+50
Humidity 5% ~ 95% Non-condensing
Dust Resistance TELCORDIA GR63-CORE
1G, 10~150Hz
Vibration Resistance
0.1 Octaves/min

3.3 Electrical Specifications

Parameter
Range 40dB ~ 80dB
CDMA
Adjust Step ±1.0dB
Gain
Adjust Accuracy ±0.5dB
Range 40dB ~ 65dB
IDEN
Adjust Step ±1.0dB
Gain
Adjust Accuracy ±0.5dB
Specification Remark
Propagation
Delay
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
CDMA
iDEN
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
4.0μ s
5.0μ s
15
Report No. : HCT-R07-020 15/37
FCC ID : U88GSTR-TRIT-SPR
Spurious
Emission
F0±885kHz
F0±1.98MHz
Out Band Spurious Emission
@ CHOFFSET 25kHz
Adjacent
Channel
Power
@ CHOFFSET 50kHz
@ CHOFFSET 500kHz
@ CHOFFSET 1MHz
@ CH
OFFSET 2MHz
@ 869MHz 868.8MHz / 868.6MHz Adjust
Band Edge
@ 940MHz 939.8MHz/ 939.6MHz
Flatness
Return Loss / VSWR
Up link
CDMA
-45dBc
-50dBc
-13dBm
50dBc
55dBc
55dBc
55dBc
55dBc
±1.25dB
14dB /1.5: 1
4.5dB @ Max gain
12dB @ Min gain
marker: 29dB
marker: 34dB
RBW: 30MHz
Degradation of 3dB
for eight (8) iDEN
carriers
200kHz 2Step
800 ~ 900MHz
Noise Figure
iDEN
5dB @ Max gain
12dB @ Min gain
Wave form quality ( ρ )
0.912
CDMA (PCS)
BER iDEN
40dBc
50dBc
50dBc
Tes t f re qu en cy
measured from band
edge
Roll off
CDMA
(PCS)
±1.0MHz
±1.5MHz
IDEN ±1.0MHz
Characteristic Impedance 50

3.4 Functions

Parameter Specification
Gain Control
• Adjustable DL and UL Gain range 40~65dB
• Display default Gain and current Gain function
• It always operates in Downlink AGC ON status
AGC
Auto Gain Control
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
• To maintain same Downlink output power despite flexible input signal
strength.
• To add or subtract Attenuation level referring to AGC Power Limit level.
16
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 16/37
FCC ID : U88GSTR-TRIT-SPR
• To limit output power as far as default range
• Set up via GUI
ALC
Auto Limit Control
Band Select • To select either 18MHz or 7MHz in 800MHz Band
Band Edge Adjust • To shift Band edge of DL high frequency side by 200kHz, 400kHz step
Power Monitoring
Function
Oscillation Check
DL Input control • Monitoring Donor ANT input power of DL
• Automatic Gain decrement when output power of repeater is higher than
default level
• Automatic Gain recovery when output power of repeater is reduced.
• Shutdown when output power is higher than default level in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
• Monitoring repeater’s output level
• Isolation Check in initial set up or Reset
• Monitoring Oscillation comparing to minimum/maximum Noise Floor level
• When Oscillation occurred, repeater attempts to stabilize Isolation through
Gain control function.
• Shutdown repeater when Oscillation still goes in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
Automatic Recovery
Security
Temperature
control
VSWR Monitoring
IP address report
via E-mail
DHCP Client • Automatic IP assignment
DHCP Server • Server function for automatic IP assignment
Web GUI • Remote and local user browser support through Web Browser
• When in repeater shutdown, it periodically recovers output power of
repeater then monitors alarming
• Support HTTPS for Web Browser security
• User authentication through User ID and Password
• Monitoring temperature of repeater
• Maximum and minimum set up is possible. Shutdown in over temperature
• Automatic recovery after temperature becomes normal. (Hysteresis
10degree)
• Monitoring VSWR of Donor ANT Port (Every one and half minute)
• Reporting VSWR Alarm and Shutdown when the rate is 3:1
• Automatic Recovery Algorithm conversion after Shutdown status
• When in PPP reconnection, E-mail which includes HTML to connect to
newly assigned IP Address, reports to operator.
SNMP Agent • NMS report via SNMPv2 Trap
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
17
Report No. : HCT-R07-020 17/37
FCC ID : U88GSTR-TRIT-SPR
LED Display
• LED displays power and operation status on front side of repeater system.
• DL input and output signal level is verified by LED bar.

4. SET UP

4.1 System Set up

4.1.1 Constitution (based on 1 SET)
Parameter Item Quantity
Major accessory TRI Case 1 EA
Additional components Main power input Cable
Mountable Bracket
Fixable Screw
User Manual Manual 1 EA
4.1.2 Notice
1) System Power check: Major electricity is AC120V, therefore please input electricity after power
1 EA
1 EA
1 SET
verification.
<Pic.8> MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug)
2) Input condition optimization: DL input condition of iDEN is -43 ~ -18dBm, and -56 ~ -16dBm
for CDMA. User should verify input condition of Donor ANT
3) Isolation check between DONOR/SERVICE ANT: Isolation condition of this equipment is 80dBc (Gain+
15dB) in iDEN, and 95dBc (Gain+15dB) in US PCS. User should check its condition before installation.
4) This equipment is basically wall mountable installation.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
18
Report No. : HCT-R07-020 18/37
FCC ID : U88GSTR-TRIT-SPR
.
<Pic.9> Tri-band In-building Repeater Case mounts
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
19
Report No. : HCT-R07-020 19/37
FCC ID : U88GSTR-TRIT-SPR
<Pic.10> Tri-band In-building Repeater Case installation
4.1.3 System set up
1) Once aforementioned process is done, open for service get ready.
2) For grounding, there is a grounding terminal in main power supply side and the grounding
terminal on a site and unit should be connected same.
3) System installation work is basically performed more than two people and should be careful for
unexpected accident.
4.1.4 Open for service
1) Check points before open
a. Verification of system installation status
Electricity, In/out antenna, coaxial cable connection, equipment mounts status.
b. Verification of system accessories
User should check whole necessary accessories.
c. Check receipt signal level
User should check whether receipt environmental condition is in accordance with system specification,
so that system operation will be optimized.
2) Check points after open
a. Check by external LED
RUN: G reen light ON (Off: Green light off)
ALARM: Green light in normal status, Red light in alarming
SHUT DOWN: Green light in normal status, Red light in Shutdown
iDEN
Number of LED bar on front side of repeater will show input signal level.
-43 dBm~38dBm: LED 1bar
-37dBm~-33dBm: LED 2 bars
-32dBm~-28dBm: LED 3 bars
-27dBm~-23dBm: LED 4 bars
Up than -22dBm: LED 5 bars
Number of LED bar in output power side will show output power signal level.
+0dBm~+4dBm: LED 1bar
+5dBm~+9dBm: LED 2bars
+10dBm~+14dBm: LED 3bars
+15dBm~+19dBm: LED 4bars
Up than +20dBm: LED 5bars
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
20
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 20/37
FCC ID : U88GSTR-TRIT-SPR
CDMA:
Number of LED bar on front side of repeater will show input signal level.
Less than -56dBm: LED 1bar
-56dBm~-48dBm: LED 2bars
-48dBm~-39dBm: LED 3 bars
-39dBm~-31dBm: LED 4 bars
-31dBm~-23dBm: LED 5 bars
Number of LED bar in output power side will show output power signal level
Less than +6dBm: LED 1bar
+6dBm~+12dBm: LED 2 bars
+12dBm~+15dBm: LED 3 bars
+15dBm~+18dBm: LED 4 bars
+18dBm~+22dBm: LED 5 bars
<Pic.11> Tri-band In-building Repeater front LED
b. Verification via Debug Program
User should check operation status of repeater system via Debug Program.
c. Verification of operation status
Use should verify following status with Output monitoring terminal, which is provided by
Spectrum Analyzer.
- Output power generation status, system spurious emission characteristics.
d. Verification of signal quality and strength in service area
User should verify signal strength and quality of in-service coverage area by using cell phone or
other terminal.
e. Verification of upper-level NMS operation status
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
21
Report No. : HCT-R07-020 21/37
FCC ID : U88GSTR-TRIT-SPR

4.2 Troubleshooting

In case, abnormal operation is detected, user should check abnormal parts via remote accessible
function or field debug, then conduct repair after turn it off.
4.2.1 Necessary Testing and Measuring equipment
a. RF Power Meter: 10Watt Max, 50ohm
b. Signal Generator: 3GHz
c. Spectrum Analyzer: 3GHz
d. Multi Meter
4.2.2 Notice
a. Trouble shooting should be performed with drastic knowledge basis.
b. Unsure parts should not be disassembled.
c. When in trouble shooting, technician should use attenuator to check output side.
4.2.3 Simple trouble shooting method
a. In not important trouble, technician adjust the unit via remote accessible function or field debugging
and should verify the reason of trouble.
b. Each Alarm LED included in each module should be verified trouble.
Normal operation: Green light On. Alarming: Red LED on
c. Technician should check external and internal connectors then fasten them. Those connectors
should be cleaned up regularly.
d. If technician think this is heavy problem, call after sales team immediately.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
22
Report No. : HCT-R07-020 22/37
FCC ID : U88GSTR-TRIT-SPR

5. WEB USER INTERFACE

5.1 Common set up (PCS, IDEN)

5.1.1 IP Address verification and Explorer setting

(1) Start->Control Panel->Network Connections
(2) Double-click Local Area Connections at LAN or High Speed internet
(3) Click Internet Protocol (TCP/IP) at General tap and click Properties.
(4) Apply automatic IP address assignment at local connection
(5) Verify assigned IP address at local connection.
(Unless IP address is not assigned, please click
repair.)
HYUNDAI CALIBRATION & CERTIFICATION
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-
TEL:+82 31 639 8517 FAX:+82 31 639 8525
23
Report No. : HCT-R07-020 23/37
TECHNOLOGIES CO., LTD.
DO, 467-701, KOREA
www.hct.co.kr
FCC ID : U88GSTR-TRIT-SPR
5.1.2 Explorer option setting
- Proceed step by step as indicated in below. All files and records should be removed.
- Set up mode will be displayed after (2) click.
- Please proceed along following set up mode screen shot.

5.2 PCS Web UI

5.2.1 Web UI connection

- Input desirable IP address.
- Default Use Name and Password for Web UI is ‘admin’.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 24/37
24
5.2.1 Link menu
FCC ID : U88GSTR-TRIT-SPR
- Following screen shot is located left-top side of main menu and those are linked to relative
window.

5.2.2 Web UI control

5.2.2.1 Status

- Currently setting level check at this menu tap.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 25/37
25
FCC ID : U88GSTR-TRIT-SPR
5.2.2.2 RF Configuration
- Setting level can be changed at this menu tap.
- (1) Level change
- (2) Click Apply button
5.2.2.3 Alarm Configuration
- (1) On/Off function for entire alarm report
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 26/37
26
FCC ID : U88GSTR-TRIT-SPR
- (2) Alarm status
- (3) On/Off function for individual alarm category
- (4) Alarm SNMP Mapping
- User may set and change its level per it field condition and click apply button.
5.2.2.4 Communication Configuration
- This provides all necessary information related to network
- To provide relative information about DHCP and modem
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 27/37
27
FCC ID : U88GSTR-TRIT-SPR
5.2.2.5 User Management
- Add and Remove user, Assigning accessibility
- (1) User Registration: Click Register after input required information
- (2) User Removal: Click Delete upon click of user name you wish to remove.
- (3) Super User: Accessible to all kinds of information path
Read/Write: Accessible to all kinds of information path except for User management path.
Read: Checking status only. No control
5.2.2.6 Logs
- All users’ access record will be saved as a log.
5.2.2.7 Sub System/Mailing List
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 28/37
28
FCC ID : U88GSTR-TRIT-SPR
- Set up e-mail address the place you wish to receive alarm.
5.2.2.8 Troubleshooting
Following is a trouble shooting table, which is frequently occurred to repeater and treatment me
thod.
5.2.2.9 Remote Software Upgrade
- Upload repeater operation program.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 29/37
29
5.2.2.10 System Reset
- Reset repeater.
FCC ID : U88GSTR-TRIT-SPR

5.3 IDEN Web UI

5.3.1 Web UI connection

- Input IP address, want to reach.
- Default setting User Name and Password for Web UI is ‘admin’.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 30/37
30
FCC ID : U88GSTR-TRIT-SPR
5.3.1.2 Link menu
Following screen shot is located left side of main menu and those are linked to relative window.

5.3.2 Web UI Control

5.3.2.1 Status
- Currently setting level check at this menu tap.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
31
Report No. : HCT-R07-020 31/37
FCC ID : U88GSTR-TRIT-SPR
5.3.2.2 RF Configuration
- Setting level can be changed at this menu tap.
- (1) Level change
- (2) Click Apply button
5.3.2.3 Alarm Configuration
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 32/37
32
FCC ID : U88GSTR-TRIT-SPR
- (1) On/Off function for entire alarm report
- (2) Alarm status
- (3) On/Off function for individual alarm category
- (4) Alarm SNMP Mapping
- User may set and change its level per it field condition and click apply button.
5.3.2.4 Communication Configuration
- This provides all necessary information related to network
- To provide relative information about DHCP and modem
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
33
Report No. : HCT-R07-020 33/37
5.3.2.5 User Management
FCC ID : U88GSTR-TRIT-SPR
- Add and Remove user, Assigning accessibility
(1) User Registration: Click Register after input required information
(2) User Removal: Click Delete upon click of user name you wish to remove.
(3) Super User: Accessible to all kinds of information path
Read/Write: Accessible to all kinds of information path except for User management path.
Read: Checking status only. No control
5.3.2.6 Logs
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-020 34/37
34
FCC ID : U88GSTR-TRIT-SPR
- All users’ access record will be saved as a log.
5.3.2.7 Sub System/Mailing List
- Set up e-mail address, the place you wish to receive alarm
5.3.2.8. Troubleshooting
-
Following is a trouble shooting table, which is frequently occurred to repeater and treatment me
thod.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
35
Report No. : HCT-R07-020 35/37
FCC ID : U88GSTR-TRIT-SPR
5.3.2.9 Remote Software Upgrade
- Upload repeater operation program
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
36
Report No. : HCT-R07-020 36/37
5.3.2.10 System Reset
- Reset repeater
FCC ID : U88GSTR-TRIT-SPR
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
37
Report No. : HCT-R07-020 37/37
Loading...