NOTE: This equipment has been tested and found to comply with the li mits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
CAUTION
Changes or modifications not expressly approved
by the manufacturer responsible for compliance
could void the user's authority to operate the equipment
2. SYSTEM STRUCTURE...............................................................................................5
2.1 Network structure for iDEN 25dBm RF Repeater............................................................................................. 5
2.2 System Design and Operation..............................................................................................................................6
3.1 System specifications...........................................................................................................................................11
3.2 Electrical and Environment Specifications.......................................................................................................12
4. SET UP .....................................................................................................................15
4.1 System Set up.......................................................................................................................................................15
4.2 T roubleshooting...................................................................................................................................................19
c. When in trouble shooting, technician should use attenuator to check output side.......................................... 19
5. WEB USER INTERFACE .........................................................................................19
5.1 IP Address verification and Explorer setting....................................................................................................19
5.2 Web UI.................................................................................................................................................................21
5.3 Web UI control....................................................................................................................................................22
3/26
FCC ID : U88GSTR-825DC-SPR
1. SUMMARY
iDEN repeater is located in blanket / shadow area of insider of building to transmit
iDEN800MHz, iDEN900MHz BTS signal simultaneously.
There are two types of RF Repeater for iDEN band as each 15dBm, and 25dBm output power
in system 65dB Gain, and 30dBm output power in system 80dB Gain.
This User Manual is the Repeater having 65dBGain / +25dBm output power.
To avoid paging signal interference at 940MHz side, IF Converter shift SAW filter edge by
200KHz, 400KHz. (TX Edge only, not whole bandwidth).
Also, This Repeater is equipped for Output power control by AGC/ALC, Gain Control by
Attenuator adjustment, Remote Control by using Web UI and Remote Firmware Up-grade.
Abbreviation
PAM: POWER AMPLIFIER MODULE
LNA: LOW NOISE AMPLIFIER
AGC: AUTO GAIN CONTROL
ALC: AUTO LIMIT CONTROL
4/26
FCC ID : U88GSTR-825DC-SPR
2. SYSTEM STRUCTURE
2.1 Network structure for iDEN 25dBm RF Repeater
Below picture shows a Network structure for iDEN In-building RF Repeater in a real site. Donor
ANT takes a position on the direction to BTS which be linked, and Server ANT is available to be
located in designated area for service by using RF cable deployments and dividers as blow.
One thing that we consider is Path losses between Repeater port and ANT in case of dividing by
dividers and RF cables. They should be equally managed.
<Pic.1> iDEN In-building Repeater Service Organization
5/26
FCC ID : U88GSTR-825DC-SPR
2.2 System Design and Operation
2.2.1 System design
NO. PART NO. PART
① MODEM MODULE ⑦ RVS LAN MODULE
② CAVITY FILTER MODULE ⑧ FWD LAN MODULE
③ PSU MODULE ⑨ I’O BOARD MODULE
④ 7M IF CONVERTER MODULE ⑩ POWER AMPLIFIER MODULE
⑤ 18M IF CONVERTER MODULE ⑪ WAV E MONITORING MODULE
⑥ 5M IF CONVERTER MODULE ⑫ NMS MODULE
6/26
FCC ID : U88GSTR-825DC-SPR
<Pic.2> iDEN 25dBm internal design
NO. PORT NO. PORT
① SERVICE ANT PORT ⑤ AC POWER PORT
② SERVICE ANT TERM ⑥ DC POWER PORT
③ DONOR ANT PORT ⑦ MONITOR PORT
④ DONOR ANT TERM ⑧ ETHERNET PORT
<Pic.3> iDEN 25dBm PORT design
2.2.2 Downlink Path
There are four (4) parts of downlink Block in iDEN In-building RF Repeater.
- Filter part for Multiplex four (4) bands as each 800MHz and 900MHz TX/RX in Front End
of Donor/Server
- LNA part of Donor/Service path to process signals of 800MHz and 900MHz bands.
7/26
FCC ID : U88GSTR-825DC-SPR
- If Converter part having several bands of SAW Filter paths to adjust Band Edge of high
frequency as 200KHz and 400KHz each. In case of 800MHz band, extra Switching Filters
equipped to individually select 18MHz and 7MHz
- Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to
adjust desirable output power of Repeater
Downlink frequency contains lots of signals such as Paging signal, DCS etc through Donor ANT.
So Out band signals should be minimized by SAW f ilters having excellent Roll off characteristics
for the best optimized operation.
Uplink Block of iDEN In-building RF Repeater is separated as four (4) parts.
- Filter part for Multiplex four (4) bands as each 800MHz and 900MHz TX/RX in Front End
8/26
FCC ID : U88GSTR-825DC-SPR
of Donor/Server
- LNA Part of two(2) paths for processing 800MHz and 900MHz signals
- 800MHz IF Converter part and 900MHz IF Converter part of 5MHz band having Switching
filter parts for selecting each 18MHz and 7MHz.
- Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to
adjust desirable output power of Repeater
800MHz IF Converter part is designed to select single path, and it can be minimizing signal
interference between paths, and power consumption according to controls of electric power in
each SAW Filter part.
2.2.4 Adjustable Band Edge functional circuit configuration
In case of IDEN using the bandwidth of 800MHz and 900MHz, many of Out of Band Signals is
input via Donor ANT Outdoor. The most worried signal among them is Paging Signal.
9/26
FCC ID : U88GSTR-825DC-SPR
Commercial Paging Signal of 929MHz~932MHz, 940MHz~941MHz, having the strength of Max.
-15dBm, is to be inputted into Donor ANT. Among this two kind of Paging Signal Band,
929MHz~932MHz bandwidth is possible for sufficient Rejection via SAW Filter, But
940MHz~941MHz is diff icult to gain big decreasi ng volume even if use SAW Filter because B and
Edge is as close as to be folded to 935MHz~940MHz of being the frequency of iDEN900MHz
Downlink.
To prepare for this environment, Down Link of iDEN Repeater is designed to have additional
Roll Off characteristic by decreasing band of SAW Filter in the station adjacent to paging signal,
for it having the function of Adjust Band Edge that can decrease c of high frequency by 200 kHz,
400 kHz each.
<Pic.6>Additional Roll off through Adjust Band Edge
10/26
3. SPECIFICATIONS
3.1 System specifications
Characteristic Specification
FCC ID : U88GSTR-825DC-SPR
Frequency Range
System Group Delay
Characteristic Impedance 50 ohm
Input Power Range -43 ~ -18dBm (FWD, RVS common)
18 MHz BAND 851~869 MHz
17.8 MHz BAND 851~868.8 MHz
800MHz
Forward
900MHz
800MHz
Reverse
900MHz 5 MHz BAND 896~901 MHz
VSWR Max.1.5 : 1
Gain Range 40dB ~ 65 dB
17.6 MHz BAND 851~868.6MHz
7 MHz BAND 862~869 MHz
6.8 MHz BAND 862~868.8 MHz
6.6 MHz BAND 862~868.6MHz
5 MHz BAND 935~940MHz
4.8 MHz BAND 935~939.8MHz
4.6 MHz BAND 935~939.6MHz
18 MHz BAND 806~824 MHz
7 MHz BAND 817~824 MHz
< 8 ㎲
Noise Figure
Gain Adjustment Step(Accuracy) 1dB(±0.5dB)
< 5 dB @ Max Gain
<12 dB @Min Gain
11/26
FCC ID : U88GSTR-825DC-SPR
Pass Band Ripple 2.5dB(±1.25dB)
Maximum Output Power
Adjacent
Channel
Power
Band Edge
316.2mW / 25dBm @ Composite Power
800MHz:22dBm, 900 MHz:22dBm
User should check whether receipt environmental condition is in accordance with system specification,
so that system operation will be optimized.
2) Check points after open
17/26
FCC ID : U88GSTR-825DC-SPR
a. Check by external LED
RUN: Green light ON (Off: Green light off)①
ALARM: Green light in normal status, Red light in alarming②
SHUT DOWN: Green light in normal status, Red light in Shutdown ③
iDEN ④
Number of LED bar on front side of repeater will show input signal level.
-43 dBm~38dBm: LED 1bar
-37dBm~-33dBm: LED 2 bars
-32dBm~-28dBm: LED 3 bars
-27dBm~-23dBm: LED 4 bars
Up than -22dBm: LED 5 bars
Number of LED bar in output power side will show output power signal level.
+0dBm~+4dBm: LED 1bar
+5dBm~+9dBm: LED 2bars
+10dBm~+14dBm: LED 3bars
+15dBm~+19dBm: LED 4bars
Up than +20dBm: LED 5bars
<Pic.10>iDEN In-building RF Repeater front LED
b. Verification via Debug Program
User should check operation status of repeater system via Debug Program.
c. Verification of operation status
Use should verify following status with Output monitoring terminal, which is provided by
18/26
FCC ID : U88GSTR-825DC-SPR
Spectrum Analyzer.
- Output power generation status, system spurious emission characteristics.
d. Verification of signal quality and strength in service area
User should verify signal strength and quality of in-service coverage area by using cell phone or
other terminal.
e. Verification of upper-level NMS operation status
4.2 Troubleshooting
In case, abnormal operation is detected, user should check abnormal parts via remote accessible
function or field debug, then conduct repair after turn it off.
4.2.1 Necessary Testing and Measuring equipment
a. RF Power Meter: 10Watt Max, 50ohm
b. Signal Generator: 3GHz
c. Spectrum Analyzer: 3GHz
d. Multi Meter
4.2.2 Notice
a. Trouble shooting should be performed with drastic knowledge basis.
b. Unsure parts should not be disassembled.
c. When in trouble shooting, technician should use attenuator to check output side
.
5. WEB USER INTERFACE
5.1 IP Address verification and Explorer setting
5.1.1 IP Address verification
(1) Start->Control Panel->Network Connections
(2) Double-click Local Area Connections at LAN or High Speed internet
(3) Click Internet Protocol (TCP/IP) at General tap and click Properties.
(4) Apply automatic IP address assignment at local connection
19/26
FCC ID : U88GSTR-825DC-SPR
(5) Verify assigned IP address at local connection.
(Unless IP address is not assigned, please click
repair.)
5.1.2 Explorer option setting
- Proceed step by step as indicated in below. All files
and records should be removed.
- Set up mode will be displayed after (2) click.
- Please proceed along following set up mode screen shot.
20/26
FCC ID : U88GSTR-825DC-SPR
5.2 Web UI
5.2.1 Web UI connection
- Input desirable IP address.
- Default Use Name and Password for Web UI is ‘admin’.
5.2.2 Link menu
- Following screen shot is located left-top side of main menu and those are linked to relative
21/26
window.
5.3 Web UI control
FCC ID : U88GSTR-825DC-SPR
5.3.1 Status
- Currently setting level check at this menu tap.
5.3.2 RF Configuration
- Setting level can be changed at this menu tap.
- (1) Level change
- (2) Click Apply button
22/26
FCC ID : U88GSTR-825DC-SPR
5.3.3 Alarm Configuration
- (1) On/Off function for entire alarm report
- (2) Alarm status
- (3) On/Off function for individual alarm category
- (4) Alarm SNMP Mapping
- User may set and change its level per it field condition and click apply button.
5.3.4 Communication Configuration
23/26
FCC ID : U88GSTR-825DC-SPR
- This provides all necessary information related to network
- To provide relative information about DHCP and modem
5.3.5 User Management
- Add and Remove user, Assigning accessibility
- (1) User Registration: Click Register after input required information
- (2) User Removal: Click Delete upon click of user name you wish to remove.
- (3) Super User: Accessible to all kinds of information path
Read/Write: Accessible to all kinds of information path except for User management path.
Read: Checking status only. No control
24/26
FCC ID : U88GSTR-825DC-SPR
5.3.6 Logs
- All users’ access record will be saved as a log.
5.3.7 Sub System/Mailing List
- Set up e-mail address the place you wish to receive alarm.
5.3.8. Troubleshooting
Following is a trouble shooting table, which is frequently occurred to repeater and treatment me
thod.
25/26
FCC ID : U88GSTR-825DC-SPR
5.3.9 Remote Software Upgrade
- Upload repeater operation program.
5.3.10 System Reset
- Reset repeater.
26/26