FCC ID : U88GSTR1924DT-SPR
ATTACHMENT E.
- USER MANUAL -
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 1/35
FCC ID : U88GSTR1924DT-SPR
INFORMATION TO USER :
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at his own expense.
CAUTION
Changes or modifications not expressly approved
by the manufacturer responsible for compliance
could void the user's authority to operate the equipment
2
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 2/35
FCC ID : U88GSTR1924DT-SPR
- INDEX -
1. SUMMARY .................................................................................................................4
2. SYSTEM CONFIGURATION.....................................................................................6
3. SPECIFICATIONS...................................................................................................12
3.1 System Specifications (applicable to both Uplink & Downlink).....................................................................12
3.2 Electrical and Environment Specifications.......................................................................................................12
3.3 Functions..............................................................................................................................................................13
4. SET UP .....................................................................................................................16
4.1 System Set up.......................................................................................................................................................16
4.2 T roubleshooting................................................................................................................................................... 19
5. WEB USER INTERFACE .........................................................................................26
5.1 IP Address verification and Explorer setting....................................................................................................26
5.2 PCS Web UI.........................................................................................................................................................28
3
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 3/35
FCC ID : U88GSTR1924DT-SPR
1. SUMMARY
US PCS 1900 RF repeater is an analog RF repeater, which improves PCS network.
US PCS 1900 RF repeater receives RF signal from BTS and transmits it to the blanked and
shadowed area, thus providing and improving voice and image data services. US PCS 1900 RF
repeater’s goal is to support BTS’s functions proportionately.
US PCS 1900 RF repeater communicates with BTS wirelessly, thus saving additional costs for its
maintenance.
US PCS 1900 RF repeater consists of PA (Downlink, Uplink), IF, LNA (Downlink, Uplink), I/O &
Control divisions, which are supplied with Alarm LED, thus providing quick and easy
maintenance and troubleshooting of the repeater.
This manual describes in general structure of US PCS1900 repeater, its application, maintenance
and troubleshooting, installation and operation etc.
Abbreviation
PAM: POWER AMPLIFIER MODULE
LNA: LOW NOISE AMPLIFIER
AGC: AUTO GAIN CONTROL
ALC: AUTO LIMIT CONTROL
4
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 4/35
FCC ID : U88GSTR1924DT-SPR
Ethernet Instruction “ This equipment is indoor use and all the communication wirings
are limited to inside of the building” or similar texts.
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the
equipment and shall be easily accessible.
Replaceable batteries instruction
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECTIVE TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
5
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 5/35
FCC ID : U88GSTR1924DT-SPR
2. System Configuration
2.1 US PCS 1900 service organization
US PCS 1900 repeater decreases blanked and shadowed areas and extends cell coverage by re-
transmitting signal. The signal is received from BTS via Antenna directly, thus excluding
additional expenses for signal transmission (like cabling). Service organization of CDMA In-
building RF repeater is shown at the picture below. Donor Antenna is directed to BTS, and being
divided at Service Antennas are installed in the building and parking place. Pass Loss should be
taken into consideration while dividing and cabling.
<Pic.1> US PCS 1900 Service organization
6
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 6/35
FCC ID : U88GSTR1924DT-SPR
2.2 System Design and Operation
2.2.1 System design
2
2
3
3
1
1
Do nor Ca v i ty
Do nor Ca v i ty
Donor Cavity
Donor Cavity
1
1
1
1
IF- 1 5M H z
IF- 1 5M H z
IF-15MHz
IF-15MHz
5
5
5
5
Wa v e fo rm Det ec t o r
Wa v e fo rm Det ec t o r
Waveform Detector
Waveform Detector
9
9
9
9
9
9
12 13
12 13
2
2
2
2
6
6
6
6
10
10
10
10
6 5 4 7 8
6 5 4 7 8
10 11
10 11
Se r v ice Ca v i ty
Se r v ice Ca v i ty
Service Cavity
Service Cavity
IF- 2 0M H z
IF- 2 0M H z
IF-20MHz
IF-20MHz
11
11
11
FW D PAM
FW D PAM
FWD PAM
FWD PAM
11
I/O & N M S B o a r d
I/O & N M S B o a r d
I/O & NMS Board
I/O & NMS Board
3
3
3
3
RV S L N A
RV S L N A
RVS LNA
RVS LNA
7
7
7
7
RV S PAM
RV S PAM
RVS PAM
RVS PAM
IF- 1 0M H z
IF- 1 0M H z
IF-10MHz
IF-10MHz
4
4
4
4
FWD L N A
FWD L N A
FWD LNA
FWD LNA
8
8
8
8
12
12
12
12
Po wer Supp l y
Po wer Supp l y
Power Supply
Power Supply
HUB
HUB
HUB
HUB
13
13
13
13
<Pic.2> Repeater’s inside structure
7
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 7/35
FCC ID : U88GSTR1924DT-SPR
1
2
2
3
3
5
5
6
6
1
4
4
Do nor A nt en na
Do nor A nt en na
Donor Antenna
Donor Antenna
1
1
1
1
CL I
CL I
CLI5CLI
5
5
5
Ser v ic e Ante nna
Ser v ic e Ante nna
Service Antenna
Service Antenna
2
2
2
2
Ether net H U B
Ether net H U B
Ethernet HUB
Ethernet HUB
6
6
6
6
<Pic.3> Repeater’s Top and Bottom panels
AC I nput Por t
AC I nput Por t
AC Input Port
AC Input Port
3
3
3
3
D C In p ut Por t
D C In p ut Por t
DC Input Port
DC Input Port
4
4
4
4
8
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 8/35
FCC ID : U88GSTR1924DT-SPR
<Pic.4> AC & DC ports
9
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 9/35
FCC ID : U88GSTR1924DT-SPR
2.2.2 Uplink Path
FWD and RVS Gain Budgets have similar structure. In case of Uplink Path, RF signal is
transmitted from Service Antenna to Service Cavity Filter and RVS LNA division, then the signal
is transferred to IF division, where desirable Band is selected by passing 6 Paths of RF Switch
and SAW filter. Selected Band is got together in FWD LNA division, and then transmitted to
Donor Antenna passing through Digital ATT (10dB ATT Range) and Donor Cavity Filter. Then the
signal is transmitted to BTS through Donor Antenna.
<Pic.5> Uplink Block Diagram
2.2.3 Downlink Path
Downlink Path is organized in reverse order of Uplink Path.
In case of Downlink Path, RF signal is transmitted from Donor Antenna to Donor Cavity Filter
and FWD LNA division, then the signal is transferred to IF division, where desirable Band is
selected by passing 6 Paths of RF Switch and SAW filter. Attenuation range is 40dB in Digital
Attenuator. Selected Band is transmitted to FWD Drive Am and Service Cavity Filter, after that
the signal is transferred to Service Antenna.
10
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 10/35
FCC ID : U88GSTR1924DT-SPR
<Pic.6> Downlink Block Diagram
2.2.4 US PCS Frequency Selection
AB C DE F G
AB CDE F G
1930
1930
1850
1850
AB C DE F G
AB CDE F G
1945 1950 1965 1970 1975 1990 1995
1945 1950 1965 1970 1975 1990 1995
< Forward Band Structure >
< Forward Band Structure >
1865 1870 1885 1890 1895 1910 1915
1865 1870 1885 1890 1895 1910 1915
< Reverse Band Structure >
< Reverse Band Structure >
f (MHz)
f (MHz)
f (MHz)
f (MHz)
<Pic.7> PCS Band Structure
US PCS 1900 repeater has 5MHz, 10MHz, 15MHz, 20MHz Paths in IF division, so any of these
bandwidths can be chosen for providing service. But there are some cases when this choice is
not applicable.
- Not continuous 4 Paths [5 MHz each], so total band is 20MHz (i.e. A1A3B2C1,
A1A2B1B2)
11
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 11/35
FCC ID : U88GSTR1924DT-SPR
3. Specifications
3.1 System Specifications (applicable to both Uplink & Downlink)
Characteristics Specification
Frequency Range
System Group Delay
Characteristic Impedance 50 ohm
Gain Adjustment Step(Accuracy) 1dB(±0.5dB)
Maximum Output Power 250mW / 24dBm
Forward 1930 ~ 1995MHz
Reverse 1850 ~ 1915MHz
< 5㎲
VSWR Max1.5 : 1
Input Power Range -100 ~ -20dBm (for both Uplink and Downlink)
System Isolation > 90dB
Gain Range 40dB ~ 80 dB
Noise Figure
Pass Band Ripple 2.5dB(±1.25dB)
Spurious Emissions
<-13dBm @Fc±2.25MHz (RBW: 1MHz)
< 4.5 dB @ Max Gain
<12 dB @Min Gain
>45 dBc @885kHz
>55 dBc @1.98kHz
IF Path 5MHz/10MHz/15MHz/20MHz
IF Frequency FWD: 200 MHz, RVS: 120MHz
Band Select Local Shift & RF Switching
Roll Offs > 50dBc @1MHz
Waveform Quality Factor min 0.912
3.2 Electrical and Environment Specifications
Characteristics Specification
Size(inch) / Type 16.1(W) x 17.7(L) x 6.89(H)
Power AC 120V 60Hz 3.0A
12
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 12/35
FCC ID : U88GSTR1924DT-SPR
Temperature / Weight
-10 ~+50/℃℃ 35.1lbs
Connector TYPE N Type Female
3.3 Functions
Parameter Specification
Gain Control
AGS
Auto Gain
Setting
• Adjustable DL and UL Gain range 40~80dB
• Display default Gain and current Gain function
• AGS (Auto Gain Setting) Use convenient Set-up
AGS star t
AGS start
D/L, U/L A TT: 0 d B
D/L,U/L ATT: 0dB
HPA : ON, A L C : ON, I s o l at ion Che c k: ON
HPA: ON, ALC: ON, Isolation Check: ON
I s ola t i o n g e ne ra t i o n : Wa ve d e t e c t i o n u s i n g
Isolation generation: Wave detection using
noise flo o r leve l d e te ct
noise floor level detect
Iso l at ion a n alysis: is o l ati o n faul t Æ Sys t em
Isolation analysis: isolation fault Æ System
Gain 1 d B r ed uce
Gain 1dB reduce
Sy s t e m G a i n + 7d B <
System Gain + 7dB<
is o l at ion det e ct io n va lue
isolation detection value
Gain r educe &
Gain reduce &
No
No
isolati o n O.K
Max. G ai n & isolatio n O.K
Max. Gain & isolation O.K
Yes
Yes
HPA : ON, G ain balan c e: O N,
HPA: ON, Gain balance: ON,
A G C : O N , S h u t - d o w n : O N
AGC: ON, Shut-down: ON
isolation O.K
Di s p la y Noti ce
Display Notice
HPA : Off
HPA: Off
AGS (Auto Gain Setting)
AGS (Auto Gain Setting)
→ Installation time calculation: in AGS .
→ Installation time calculation: in AGS .
No
No
S e ver A N T T u ni ng
Sever ANT Tuning
Re- i ns tallation: A G S
Re-installation: AGS
No Yes
No Yes
Cu r r e n t set t i n g
Current setting
main tenan c e
maintenance
Yes
Yes
HPA: O N
HPA: ON
AGS d o ne
AGS done
AGC
Auto Gain
Control
• It always operates in Downlink AGC ON status
• To maintain same Downlink output power despite flexible input signal strength.
• To add or subtract Attenuation level referring to AGC Power Limit level.
• To limit output power as far as default range
• Set up via GUI
ALC
• Automatic Gain decrement when output power of repeater is higher than default level
Auto Limit
• Automatic Gain recovery when output power of repeater is reduced.
Control
• Shutdown when output power is higher than default level in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
13
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 13/35
FCC ID : U88GSTR1924DT-SPR
Gain
Balance
Oscillation
Check
Spurious
Emission
Alarm
Band Select • To select either 5MHz/10MHz/15MHz/20MHz
Power
Monitoring
Function
• Downlink ATT is applied to Uplink during AGC state
• Setting and maintenance of output level
• Additional attenuation to ALC Level
• Isolation Check in initial set up or Reset
• Monitoring Oscillation comparing to minimum/maximum Noise Floor level
• When Oscillation occurred, repeater attempts to stabilize Isolation through Gain control function.
• Shutdown repeater when Oscillation still goes in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
• Noise Floor Observation in case of ±2.25MHz down at the center
• In case of Noise level > –13dBm, Spurious Emission is stabilized automatically
• In case of Oscillation Spurious Emission Alarming in Minimum Gain, repeater will be shutdown
• Automatically Switch to Recovery Algorithm at Shutdown
• Monitoring repeater’s output level
DL Input
control
Automatic
Recovery
Security
Tem p era t ur e
control
VSWR
Monitoring
IP address
report via E-
mail
DHCP Client • Automatic IP assignment
• Monitoring Donor ANT input power of DL
• When in repeater shutdown, it periodically recovers output power of repeater then monitors
alarming
• Support HTTPS for Web Browser security
• User authentication through User ID and Password
• Monitoring temperature of repeater
• Maximum and minimum set up is possible. Shutdown in over temperature
• Automatic recovery after temperature becomes normal. (Hysteresis 10 degree)
• Monitoring VSWR of Donor ANT Port (Every one and half minute)
• Reporting VSWR Alarm and Shutdown when the rate is 3:1
• Automatic Recovery Algorithm conversion after Shutdown status
• When in PPP reconnection, E-mail which includes HTML to connect to newly assigned IP Address,
reports to operator.
DHCP • Server function for automatic IP assignment
14
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 14/35
FCC ID : U88GSTR1924DT-SPR
Server
Web GUI • Remote and local user browser support through Web Browser
SNMP Agent • NMS report via SNMPv2 Trap
LED Display
• LED displays power and operation status on front side of repeater system.
• DL input and output signal level is verified by LED bar.
15
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 15/35
FCC ID : U88GSTR1924DT-SPR
4. SET UP
4.1 System Set up
4.1.1 Constitution (based on 1 SET)
Parameter Item Quantity Remark
Major accessory CDMA 24dBm repeater 1 EA Manufacture company supply
Ethernet Cable (cross)
Power Supply Cable
Additional
components
User Manual Installation Guide (Book) 1 EA Manufacture company supply
Antenna
RF Cable Antenna connection Cable TBD
Repeater quality
confirmation
equipment
Fixable Screw x 4 (Size: φ1/2”,
length: 2” )
Ground Cable
CD which contains User Manual
and installation Guide
Donor ANT
Server ANT
Spectrum Analyzer 1EA
1 EA
1 EA
1 SET
1 EA
1 EA
1EA
1EA
Manufacture company supply
Establishment construction company
preparation
Establishment construction company
preparation
Establishment construction company
preparation
4.1.2 Notice
1) System Power check: Major electricity is AC1 10 V, therefore please input electricity after power
verification.
2) Input condition optimization: DL input condition is -56 ~ -16dBm. User should verify input condition of
Donor ANT.
3) Isolation check between DONOR/SERVICE ANT: Isolation condition of this equipment is 95dBc (Gain+
15dB). User should check its condition before installation.
16
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 16/35
FCC ID : U88GSTR1924DT-SPR
<Pic. 8> MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug)
4.1.3 System set up
1)
This equipment is basically wall mountable installation.
2) Once aforementioned process is done, open for service get ready.
3) For grounding, there is a grounding terminal in main power supply side and the grounding
terminal on a site and unit should be connected same.
4) System installation work is basically performed more than two people and should be careful for
unexpected accident.
17
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 17/35
4.1.4 Open for service
FCC ID : U88GSTR1924DT-SPR
<Pic.9> Case mounts
1) Check points before open
a. Verification of system installation status
Electricity, In/out antenna, coaxial cable connection, equipment mounts status.
b. Verification of system accessories
User should check whole necessary accessories.
c. Check receipt signal level
User should check whether receipt environmental condition is in accordance with system specification,
so that system operation will be optimized.
2) Check points after open
18
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 18/35
FCC ID : U88GSTR1924DT-SPR
a. Check by external LED
RUN: Green light ON (Off: Green light off)①
ALARM: Green light in normal status, Red light in alarming②
SHUT DOWN: Green light③ in normal status, Red light in Shutdown
Number of LED bar on front side of repeater will show input signal level. ⑤
Less than -56dBm: LED 1bar
-56dBm~-48dBm: LED 2bars
-48dBm~-39dBm: LED 3 bars
-39dBm~-31dBm: LED 4 bars
-31dBm~-23dBm: LED 5 bars
Number of LED bar in output power side will show output power signal level
Less than +15dBm: LED 1bar
+16dBm~+17dBm: LED 2 bars
+18dBm~+19dBm: LED 3 bars
+20dBm~+22dBm: LED 4 bars
More than +23dBm: LED 5 bars
<Pic.10> Front LED Indicator
4.2 Troubleshooting
In case, abnormal operation is detected, user should check abnormal parts via remote accessible
19
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 19/35
FCC ID : U88GSTR1924DT-SPR
function or field debug, then conduct repair after turn it off.
4.2.1 Necessary Testing and measuring equipment
a. RF Power Meter: 10Watt Max, 50ohm
b. Signal Generator: 3GHz
c. Spectrum Analyzer: 3GHz
d. Multi Meter
4.2.2 Notice
a. Trouble shooting should be performed with drastic knowledge basis.
b. Unsure parts should not be disassembled.
c. When in trouble shooting, technician should use attenuator to check output side.
4.2.3 Note at set up process / Check point after open for service
Item Check Point Trouble shooting
Note
before
system
operation
Same as
above
* System Input power range
Down Link -100dBm/Total ~ -20dBm/Total
Up Link -100dBm/Total ~ -20dBm/Total
Down Link 40 ~ 80dB
* System Gain
Up Link 40 ~ 80dB
Input Level
Gain
20
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 20/35
FCC ID : U88GSTR1924DT-SPR
Output power
Same as
above
Check in
Advance
* Output power at edge port side
Down Link 24dBm/Total
Up Link 24dBm/Total
* Please check quantity of all accessories with specification
before you set up.
* Check points before open for
* Fit cable length in accordance with field condition.
service
* Set up Donor antenna to assure enough Isolation (More
than 87dBc)
* Check following status
- Fixable level of antenna support pole
- Connection status between antenna and RF cable
- RF Cable construction and fixed status
- fix of repeater and installation status
- Electricity construction and proper AC power status
Check
after
open
* Check points after open for service
- Plug status and electricity voltage status
- wall socket and voltage status
- Grounding (EARTH) status
- Direction of Donor antenna
(PN Offset and neighborhood BTS to be considered.)
- Ground status of repeater (unit itself)
- Coaxial cable construction status
- Connector combiner connection status
- Cable connection status against leakage of water
4.2.4 Trouble shooting guide related to RF
Symptom Check Point Troubleshooting
21
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 21/35
FCC ID : U88GSTR1924DT-SPR
When repeater
does not work
properly
Same as above
When in
alarming
When in
alarming
* Checking Electricity Cord
connection status
* Checking electricity input to
AC power outlet.
* DL over-input alarm
* DL over-output alarm
* Re-plug in AC power cord
* Please verify AC power input by using DVM (Digital Voltage
Meter)
* Please Check following status
- Proper maximum output power limit level
- BTS input level (Spectrum Level)
- Input RSSI value at Status mode
- Downlink Attenuation level
- Downlink Attenuation Table
* Please reset AC power upon complete Alarm trouble shooting
* Please make sure output power is operated normally.
* Please reset AC power upon complete Alarm trouble
shooting.
When in
alarming
When in
alarming
When in
alarming
When in
alarming
* UL over-output alarm
* Please make sure output level is operated normally
* Please reset AC power upon complete Alarm trouble shooting
* Please Check following status
- Antenna port connection
- Whether inner-output cable is damaged or not.
* VSWR alarm
* Please reset AC power upon complete Alarm trouble
shooting
* Please verify IF Module LED is On.
* IF Module alarm
* When LED is Off, module should be defective.
* Please reset AC power upon complete Alarm trouble shooting
* DL, UL PAM alarm
22
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 22/35
FCC ID : U88GSTR1924DT-SPR
When in
alarming * DC matter/Current alarm
When in
alarming * UL Oscillation
When in
* DL / UL LNA alarm
alarming
When in
alarming
* Temperature alarm
When in
* DL low-input alarm
alarming
* Please verify DC power by using DVM (Digital Voltage Meter)
* Please reset AC power upon complete Alarm trouble
shooting.
* Please check Isolation between Donor and Server.
* Please reset AC power upon complete Alarm trouble
shooting.
* Please check connection status of LNA.
* Please reset AC power upon complete Alarm trouble shooting
* Please Check following status
- Setting level of maximum temperature limit
- Temperature offset is normal or not.
- Circumstance temperature.
* Please reset AC power upon complete Alarm trouble shooting
* Please reset AC power upon complete Alarm trouble shooting
When in
alarming
When in
alarming
When output
power is no
longer strong
or problem
* DL low-output alarm
* RF OFF
* Technician should verify
category of alarm at the front
side of repeater.
* Please Check following status
- Output power level is normal or not.
- Whether minimum output limit level is normal.
* Please reset AC power upon complete Alarm trouble shooting
* Please reset AC power upon complete Alarm trouble shooting
* When Red light on the Shutdown LED, technician should
troubleshoot the alarm via Notebook computer.
23
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 23/35
FCC ID : U88GSTR1924DT-SPR
Same as above * Technician should connect
antenna with output port of
* Reconnect the connector.
* Please change it if the connector is detective.
repeater.
* Please make sure all
connectors are fastened
Same as above * Check the input level not to
* Increase output power or check input change of BTS side.
be too low.
Same as above
* If the Gain is different from normal level, please contact A/S
* Check Gain of the unit
team.
Same as above * Cable loose or over loss. * Please contact installer or service provider upon verification.
In case of drop
* Increase output power level of repeater by adjusting
* Check receipt signal strength
call or bad
attenuation level.
in the service area not to be
signal after
too low.
set up
* If receipt signal strength is
* Please increase output level of Uplink signal, then setting by
Same as above
not a problem, please check
delay of calling time.
Same as above * Check receipt signal strength
In case, output
Signal
wavelength is
not shown flat
or looks like
oscillation
* Check connection fastened
between antenna and cable
(Signal wavelength should be
flat and stable if technicians
shake CABLE. If not, it is
connection problem.)
* Input level change or
Same as above
module blazing
.
* Please check VSWR of the
Same as above
Cable is normal.
optimal level..
* Please contact network management team or service
provider
* If connection is not proper, please make sure connector and
cable to be re-connected then check the output power again.
* Check input level from BTS side.
* Check performance of each module.
(Diagnosed by A/S team.)
* Change to normal Cable.
24
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 24/35
FCC ID : U88GSTR1924DT-SPR
4.2.4 Trouble shooting guide related to NMS
Symptom Check Points Troubleshooting
Link fail * Communication problem
* CLI Connection, Cable
Same as above
status check
* CLI connection Check by
Same as above
USB to Serial Cable
* In case of Ethernet, check set up level of IP, Gateway and so
on, when you use Ethernet.
* Make sure 1:1 connection.
* Please verify Port number of PC communication.
* Please check Cable connection status.
25
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 25/35
FCC ID : U88GSTR1924DT-SPR
5. WEB USER INTERFACE
5.1 IP Address verification and Explorer setting
5.1.1 IP Address verification and Explorer setting
(1) Start->Control Panel->Network Connections
(2) Double-click Local Area Connections at LAN or High Speed internet
(3) Click Internet Protocol (TCP/IP) at General tap and click Properties.
(4) Apply automatic IP address assignment at local connection
26
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 26/35
FCC ID : U88GSTR1924DT-SPR
(5) Verify assigned IP address at local connection.
(Unless IP address is not assigned, please click repair.)
5.1.2 Explorer option setting
- Proceed step by step as indicated in below. All files and records should be removed.
- Set up mode will be displayed after (2) click.
- Please proceed along following set up mode screen shot.
27
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 27/35
5.2 PCS Web UI
5.2.1 Web UI connection
- Input desirable IP address.
FCC ID : U88GSTR1924DT-SPR
- Default Use Name and Password for Web UI is ‘admin’.
5.2.2 Link menu
- Following screen shot is located left-top side of main menu and those are linked to relative
window.
28
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 28/35
5.3 Web UI control
5.3.1 Status
FCC ID : U88GSTR1924DT-SPR
- Currently setting level check at this menu tap.
5.3.2 RF Configuration
- Setting level can be changed at this menu tap.
- (1) Level change
- (2) Click Apply button
29
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 29/35
FCC ID : U88GSTR1924DT-SPR
30
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 30/35
FCC ID : U88GSTR1924DT-SPR
5.3.3 Alarm Configuration
- (1) On/Off function for entire alarm report
- (2) Alarm status
- (3) On/Off function for individual alarm category
- (4) Alarm SNMP Mapping
- User may set and change its level per it field condition and click apply button.
5.3.4 Communication Configuration
- This provides all necessary information related to network
- To provide relative information about DHCP and modem
31
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 31/35
5.3.5 User Management
FCC ID : U88GSTR1924DT-SPR
- Add and Remove user, Assigning accessibility
- (1) User Registration: Click Register after input required information
- (2) User Removal: Click Delete upon click of user name you wish to remove.
- (3) Super User: Accessible to all kinds of information path
Read/Write: Accessible to all kinds of information path except for User management path.
Read: Checking status only. No control
5.3.6 Logs
- All users’ access record will be saved as a log.
32
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 32/35
FCC ID : U88GSTR1924DT-SPR
33
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 33/35
FCC ID : U88GSTR1924DT-SPR
5.3.7 Sub System/Mailing List
- Set up e-mail address the place you wish to receive alarm.
5.3.8 Troubleshooting
Following is a trouble shooting table, which is frequently occurred to repeater and treatment
method.
34
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 34/35
FCC ID : U88GSTR1924DT-SPR
5.3.9 Remote Software Upgrade
- Upload repeater operation program.
5.3.10 System Reset
- Reset repeater.
35
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R07-012 35/35