1.   GENERAL ............................................................................. 7  
1.1.   Purpose ............................................................................................. 7  
1.2.   Copyright ........................................................................................... 7  
1.3.   FCC Warning Statements .......................................................................... 8  
2.   INTRODUCTION .................................................................... 11  
2.1.   System Overview ................................................................................. 11  
2.2.   Main Features .................................................................................... 12  
3.   SYSTEM DESIGN FOR EZD-LICPA23 (DONOR UNIT) ............................... 13  
3.1.   Exterior View ...................................................................................... 13  
3.2.   Interior View ...................................................................................... 14  
3.3.   External Interface ................................................................................. 15  
3.4.   FCC Statement ..................................................................................... 16  
4.   SYSTEM DESIGN FOR EZS-LICPA30 (SERVICE UNIT) ............................... 17  
4.1.   Exterior View ..................................................................................... 17  
4.2.   Interior View ...................................................................................... 18  
4.3.   External Interface ................................................................................ 19  
4.4.   FCC Statement .................................................................................... 20  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
3 
Page 4
5.   SYSTEM SPECIFICATION ............................................................ 21  
5.1.   RF Performance................................................................................... 21  
5.2.   Frequency Information ........................................................................... 23  
5.2.1.   700MHz ..................................................................................................................................................................................................... 23  
5.2.2.   800/850MHz ............................................................................................................................................................................................ 24  
5.2.3.   1900MHz ................................................................................................................................................................................................... 25  
5.2.4.   2100MHz ................................................................................................................................................................................................... 26  
5.3.    Configuration & Mechanical Specification  ..................................................... 27 
6.   SYSTEM BLOCK CONFIGURATION ................................................. 28  
6.1.    Block Diagram  .................................................................................... 28 
7.   GUI OVERVIEW ..................................................................... 30  
7.1.   Configuration the Laptop to Connect to the Repeater .......................................... 30  
7.2.   Login-In Screen .................................................................................... 31  
7.3.   Main Screen ...................................................................................... 32  
7.4.   RF Status .......................................................................................... 33  
7.5.   RF Configuration .................................................................................. 34  
7.6.   Band Selection .................................................................................... 35  
8.   SYSTEM INSTALLATION ............................................................ 36  
8.1.    Warnings and Hazards  ............................................................................ 37 
8.1.1.   Electric Shock ........................................................................................................................................................................................... 37  
8.1.2.   Exposure to RF ......................................................................................................................................................................................... 37  
8.2.    Service Man Installation Guide ................................................................. 38  
8.2.1.   Wall Mount Installation ......................................................................................................................................................................... 38  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
4 
Page 5
8.3.   Cable Connection ................................................................................. 40  
8.3.1.   AC Power cable connection .................................................................................................................................................................. 40  
8.3.2.   Local Maintenance Connection ........................................................................................................................................................... 41  
8.3.3.   Grounding cable Connection ............................................................................................................................................................... 41  
FIGURE 1.FCC/ UL CERTIFICATION STATEMENT ......................................................................................................................................................... 8  
FIGURE 2.EZ-DAS APPLICATION CONFIGURATIONS ............................................................................................................................................... 11  
FIGURE 3. EZD-LICPA23 EXTERIOR VIEW .................................................................................................................................................................. 13  
FIGURE 4. EZD-LICPA23 INTERIOR VIEW .................................................................................................................................................................. 14  
FIGURE 5. EZD-LICPA23 EXTERNAL INTERFACE ....................................................................................................................................................... 15  
FIGURE 6. EZD-LICPA23 UNIT FCC STATEMENT ....................................................................................................................................................... 16  
FIGURE 6. EZS-LICPA30 EXTERIOR VIEW ................................................................................................................................................................... 17  
FIGURE 7. EZS-LICPA30 INTERIOR VIEW ................................................................................................................................................................... 18  
FIGURE 9. EZS-LICPA30 EXTERNAL INTERFACE........................................................................................................................................................ 19  
FIGURE 10. EZS-LICPA30 UNIT FCC STATEMENT ..................................................................................................................................................... 20  
FIGURE 11. EZD-LICPA23 BLOCK DIAGRAM CONFIGURATION ............................................................................................................................ 28  
FIGURE 12. EZS-LICPA30 BLOCK DIAGRAM CONFIGURATION ............................................................................................................................. 29  
FIGURE 13. THE WAY TO FIX THE BRACKET ON THE POLE (NORMAL TYPE) .................................................................................................... 38  
FIGURE 14. THE WAY TO FIX FIRMLY THE SYSTEM FOR POLE MOUNTING ...................................................................................................... 39  
TABLE 1. EZD-LICPA23 UNIT CONFIGURATION ........................................................................................................................................................ 14  
TABLE 2. EZD-LICPA23 EXTERNAL INTERFACE DESCRIPTION ............................................................................................................................... 15  
TABLE 3. EZS-LICPA30 UNIT CONFIGURATION ......................................................................................................................................................... 18  
TABLE 4. EZS-LICPA30 EXTERNAL INTERFACE DESCRIPTION ................................................................................................................................ 19  
TABLE 5. EZ-DAS RF PERFORMANCE DESCRIPTION ............................................................................................................................................... 22  
TABLE 6. EZ-DAS 700MHZ OPERATING FREQUENCY INFORMATION ................................................................................................................. 23  
TABLE 7. EZ-DAS 800/850MHZ OPERATING FREQUENCY INFORMATION FOR CDMA .................................................................................. 24  
TABLE 8. EZ-DAS 800/850MHZ OPERATING FREQUENCY INFORMATION FOR LTE ........................................................................................ 24  
TABLE 9. EZ-DAS 1900MHZ OPERATING FREQUENCY INFORMATION FOR CDMA ......................................................................................... 25  
TABLE 10. EZ-DAS 1900MHZ OPERATING FREQUENCY INFORMATION FOR LTE ............................................................................................ 25  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
5 
Page 6
TABLE 11. EZ-DAS 2100MHZ OPERATING FREQUENCY INFORMATION ............................................................................................................ 26  
TABLE 12. EZ-DAS CONFIGURATION & MECHANICAL SPECIFICATION............................................................................................................... 27  
TABLE 13. EZ-DAS INSTALLATION ACCESSORIES...................................................................................................................................................... 36  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
6 
Page 7
1.  General  
1.1.  Purpose  
This document introduces features, specifications, structures and operation guideline for  
the EZD-LICPA23/ EZS-LICPA30.  
1.2.  Copyright  
All text and image in this document are subject to the copyright of GS Instech Co., Ltd. 
This document may not be reproduced, distributed, or modified without the written permission of  
GS Instech Co., Ltd. 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
7 
Page 8
1.3.  FCC Warning Statements  
FCC Warning Statement for system is follows. Must attach the label under manufacturing. 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Figure 1.FCC/ UL Certification Statement  
8 
Page 9
FCC Part 15.105 statement (Class A) 
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of 
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to 
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference at his own expense. 
FCC Part 15.21 statement 
Any changes or modifications not expressly approved by the party responsible for compliance  
could void the user's authority to operate this equipment. 
 Home/ personal use are prohibited    
 Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP  
and/or indoor‐only restrictions is prohibited 
9 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Page 10
RF Radiation Exposure  
This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment.  
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  
RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger 
separation distances.  
Antenna installation 
Antennas must be installed in accordance with FCC 27.50, 24.  
The height of the antenna above average terrain (HAAT) must not exceed limit in the following table.  
WARNING . THIS is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED 
INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licenses to operate this device. 
Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000  
for each continuing violation. 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
10 
Page 11
2.  Introduction  
2.1.  System Overview  
EZ-DAS is designed to improve coverage and capacity of Commercial Quad Band. 
Either feeding Carrier BTS signal directly or receiving signal via antenna, it provides coverage 
Building in RF shadow. 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Figure 2.EZ-DAS Application Configurations 
11 
Page 12
2.2.  Main Features  
● All-in One Donor Unit  
-   Compose several units such as Optic Transceiver, NMS, PSU, BDA, Cavity Filter etc.  
-   Convenient to install in Middle Size Building with proper cost of one set  
● Support the BTS or Antenna Feeding Solution  
-   Either feeding Carrier BTS Signal directly or receiving signal via Antenna  
-   With built-in BDA(Bi-Directional Amplifier) function, it is possible to use under Antenna feeding   
condition 
●  Choose the Filtering Methods accord to the operating condition  
-   For Neutral Host installations, able to support the Full Band Filtering 
●  Improving Service Quality under Multi-Carriers Area  
-   Up to 6 Non-Contiguous block and gain per block based on Downlink Input Topologies  
-   Dealing with Near-far & Uplink Noise Floor Rise  
● Topologies  
-   1:4 Branches between Donor Unit and Service Unit.   
-   3 Daisy Chain is possible with Daisy Chain Optic Unit.  
● Supporting Technologies  
-   CDMA, LTE   
● Supporting Frequencies  
-   Commercial Quad band (700M, 800+850M, 1900M, 2100M)  
● Supporting Output Power  
-   Composite 4W with EZ-DASS-LICPA 30 (1W per Band)  
-   Composite 20W with EZ-DASS-LICPA 37 (5W per Band)  
● Functions  
-   Support AGC, ALC, AGA with LLA(Low Limit ALC), ASD  
● FCC Part 22, 24,27,90 & Part 15B class A   
© 2018 GS Instech Co., Ltd.  All rights reserved.    
12 
Page 13
3. System Design for EZD-LICPA23 (Donor Unit)  
3.1.  Exterior View   
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Figure 3. EZD-LICPA23 Exterior View 
13 
Page 14
800/850MHz RF Digital Filter Unit 
1900MHz RF Digital Filter Unit 
700MHz RF Digital Filter Unit 
2100MHz RF Digital Filter Unit 
Quadplexer for 800/850M & 1900M/ 700M+2100M Band Combiner   
Quadplexer for 700M & 2100M 
AC Input Voltage: 110VAC~240VAC(60Hz)/ DC Output Voltage: +6V 
5Way RF Channel Distribute Unit 
Apply for Web-UI/ Communicate with Service Unit 
3.2.  Interior View  
Figure 4. EZD-LICPA23 Interior View 
Table 1. EZD-LICPA23 Unit Configuration 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
14 
Page 15
Feeding Downlink Signal 
/ Transmit Uplink Output 
Insert the optic cable to Service Unit 
Receive a Downlink RF Signal from EDU (Wire only) 
Transmit a uplink RF Signal to EDU (Wire only) 
Communicate a data between MDU & EDU or Server 
System Total Alarm Indication 
Maintain Humidity & Temp Inside 
3.3.  External Interface  
Figure 5. EZD-LICPA23 External Interface 
Table 2. EZD-LICPA23 External Interface Description 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
15 
Page 16
3.4. FCC Statement  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Figure 6. EZD-LICPA23 UNIT FCC Statement 
16 
Page 17
4. System Design for EZS-LICPA30 (Service Unit)  
4.1. Exterior View   
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Figure 7. EZS-LICPA30 Exterior View 
17 
Page 18
800/850MHz RF Power Amp Unit 
1900MHz RF Power Amp Unit 
2100MHz RF Power Amp Unit 
Quadplexer for 800/850M & 1900M/ 700M+2100M Band Combiner   
Quadplexer for 700M & 2100M 
AC Input Voltage: 110VAC~240VAC(60Hz)/ DC Output Voltage: +6V/ +29V 
4Way RF Channel Distribute Unit 
Apply for GUI/ Communicate with Donor Unit 
Daisy Chain Optic Unit/ For SU Cascade Application 
4.2. Interior View  
Figure 8. EZS-LICPA30 Interior View 
Table 3. EZS-LICPA30 Unit Configuration 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
18 
Page 19
Feeding Uplink Signal 
/ Transmit Downlink Output 
Insert the optic cable to Donor Unit 
Insert the optic cable to Next SU for Daisy Chain 
System Total Alarm Indication 
Maintain Humidity & Temp Inside 
4.3. External Interface  
Figure 9. EZS-LICPA30 External Interface 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Table 4. EZS-LICPA30 External Interface Description 
19 
Page 20
4.4. FCC Statement  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Figure 10. EZS-LICPA30 UNIT FCC Statement 
20 
Page 21
698MHz~716MHz/ 777MHz~787MHz 
+23dBm(0.2W)  
With EZD-LICPA23 
【CDMA 】 15MHz max/ 1.25MHz Step  
50dB ~ 90dB with EZS-LICPA30 
> 50dBc @ Channel OBW ±1MHz 
5. System Specification  
5.1.  RF Performance  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
21 
Page 22
Exclude Fiber 
Optic Delay 
Less than 6dB @ Min & Max Gain 
<-5.5dBm @50KHz ≤ ∆ f < 5.05MHz (RBW: 100KHz) 
<-12.5dBm @5.05MHz ≤ ∆ f < 10.05MHz (RBW: 100KHz) 
<-13dBm @10.5MHz ≤ ∆ f < 15MHz (RBW: 1MHz) 
> 45dBc @ ±5MHz, ±10MHz, ±20MHz, ±40MHz 
Spurious Emission 
For CDMA 
out 
> 33dBm; -55dBc with a 30KHz RBW 
28dBm  P
out
<33dBm; -22dBm with a 30KHz RBW 
-13dBm / 1 kHz: 9 kHz < f < 150 kHz 
-13dBm / 10 kHz: 150 kHz < f < 30 MHz 
-13dBm/100 kHz: 30 MHz < f < 1 GHz 
-13dBm / 1 MHz: 1 GHz < f < 12.75 GHz 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Table 5. EZ-DAS RF Performance Description 
22 
Page 23
Transmit frequency band (MHz) 
5.2.  Frequency Information  
5.2.1.  700MHz  
[LTE] 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Table 6. EZ-DAS 700MHz Operating Frequency Information 
23 
Page 24
Transmit frequency band (MHz) 
Transmit frequency band (MHz) 
5.2.2.  800/850MHz  
[CDMA] 
[LTE] 
Table 7. EZ-DAS 800/850MHz Operating Frequency Information for CDMA 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Table 8. EZ-DAS 800/850MHz Operating Frequency Information for LTE 
24 
Page 25
Transmit frequency band (MHz) 
Transmit frequency band (MHz) 
5.2.3. 1900MHz  
[CDMA] 
[LTE] 
Table 9. EZ-DAS 1900MHz Operating Frequency Information for CDMA 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Table 10. EZ-DAS 1900MHz Operating Frequency Information for LTE 
25 
Page 26
Transmit frequency band (MHz) 
5.2.4. 2100MHz  
[LTE] 
Table 11. EZ-DAS 2100MHz Operating Frequency Information 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
26 
Page 27
Donor/ Service 
Antenna Filter 
AC Input Voltage: 110VAC~240VAC(60Hz) 
DC Output Voltage: +6V/ +29V 
Antenna: 4.3-10 DIN Female 
Optic Connection: Metal Cable Gland 
EDU Connection: SMA Female(RF)/ MS3102A18-8(DATA) 
1/2" Plenum-Rated Air-Dielectric Coaxial Cable 
13.78" x 21.6" x 12.2" without Bracket 
13.78" x 21.6" x 10.3" without Bracket 
Less than 42kg (92.5lb) without Bracket 
Less than 40kg (88.1lb) without Bracket 
nonferrous metal and anchoring point on bottom side 
5.3. Configuration & Mechanical Specification  
Table 12. EZ-DAS Configuration & Mechanical Specification 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
27 
Page 28
6. System Block Configuration  
6.1.  Block Diagram  
Figure 11. EZD-LICPA23 Block Diagram Configuration 
The repeater improves service in the commercial Quad-Band. 
User may select frequency band according to the site peculiarities.  
After receiving a weak signal from Donor antenna or BTS directly, the EZD-LICPA23 sends downlink signal to EZS-
LICPA30 using DOU (Donor Optic Unit).  
DOU supports the translation of RF signal to Optic signal for connecting EZS-LICPA30 through   
the fiber optic cable. And then Uplink Signal that received from EZS-LICPA30 amplify,  
is send to the Base station via Donor Antenna or is connected to BTS directly. 
In other words, EZD-LICPA23 is only transmitting the Uplink Signal over the air. 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
28 
Page 29
Figure 12. EZS-LICPA30 Block Diagram Configuration 
 EZS-LICPA30 is operating very similar to the EZD-LICPA23 
After receiving an Uplink Signal from service antenna, the EZ-DASD-LICPA30 sends Uplink signal to  
EZD-LICPA23 using SOU (Service Optic Unit).  
SOU supports the translation of RF signal to Optic signal for connecting EZD-LICPA23 through   
the fiber optic cable. And then Down Signal that received from EZD-LICPA23 amplify,  
is send to the Mobile station via Service Antenna. 
In other words, EZD-LICPA23 is only transmitting the Uplink Signal over the air. 
29 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Page 30
1. Go to Local Connection 
2. Click on "Properties" 
3. Highlight "Internet Protocol" 
4. Click on "Properties" 
5. Choose "Obtain DNS Server 
 address automatically" 
6. Clink OK 
7.  GUI Overview  
• Provide all functions that can be performed at Service Unit will be available thru the Donor Unit.  
• Support the GUI pages that will be addressable via UDP Interface.  
7.1. Configuration the Laptop to Connect to the Repeater  
• Connect an Ethernet crossover cable from the LAN port of the repeater’s bottom side to your laptop   
© 2018 GS Instech Co., Ltd.  All rights reserved.    
30 
Page 31
7.2.  Login-In Screen  
• GUI Screen for Log-In  
• Enter the IP Address "192.168.1.1" and Port into GUI Main Screen. And then Connect.    
31 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Page 32
7.3.  Main Screen  
• GUI Screen for Main Menu  
• Able to select system that user control, Configuration & Status monitoring  
• Green means that the system is operating under normal condition.  
• Red means that the system is operating under abnormal condition. In other words, system is likely non-working.  
• Gray means that the system is not linked or communicated fail. But if it is not communicated between DU and  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
SU, Donor Unit is also changed Red. 
32 
Page 33
7.4.  RF Status  
• GUI Screen for display Repeater’s RF Status   
© 2018 GS Instech Co., Ltd.  All rights reserved.    
33 
Page 34
7.5.  RF Configuration  
• GUI Screen in order to change the RF values  
• User may change the various RF values of the repeater on this page  
• Changes will not take effect until you click "Apply" button  
• This menu is where the installer will choose references for specific implementation  
34 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Page 35
7.6. Band Selection  
• Repeater support the capacity of CDMA and LTE Technologies  
• Ability to set the 6 Non-Contiguous channel   
• Support the CDMA 15MHz max per 1.25 step and LTE 5MHz, 10MHz, 20MHz  
• User can set the desired channel using the GUI  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
35 
Page 36
AC Power Cable SJT 3/16 AWG, 6ft 
Frame Ground Cable with Tubular Cable Lug, 6ft 
Installation purchase set 
M5x12mm WRENCH BOLT, SEMS  
Φ10.5mm/Φ21mm PLAIN WASHER  
Φ10.2mm/Φ18.4mm SPRING WASHER   
Φ30mm/L:150mm Adhesive Polyolefin   
3:1 Heat Shrink  
8. System Installation  
• This chapter describes how to install the repeater and Cabling method   
• The needed accessories and tools are list up as below   
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Table 13. EZ-DAS Installation Accessories 
36 
Page 37
8.1.  Warnings and Hazards  
8.1.1.  Electric Shock  
•  Opening the Repeater could result in electrical shock and may cause severe   
injury 
•  Operating the Repeater with antennas in very close proximity facing each other  
 could lead to severe damage to the repeater 
8.1.2.  Exposure to RF  
 Working with the repeater while in operation, may expose the technician to   
RF electromagnetic fields that exceed FCC Rules for human expose.  
Visit the FCC Website at http://www.fcc.gov/oet/rfsafety to learn more about    
The effects of exposure to RF electromagnetic fields 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
37 
Page 38
Protection gloves and goggles 
Make sure that worker wears protection gloves and goggles to prevent damages from 
debris while drilling holes in a Pole or Wall 
Φ10.5mm/Φ21mm PLAIN WASHER  
Φ10.2mm/Φ18.4mm SPRING WASHER 
8.2.   Service Man Installation Guide  
8.2.1.  Wall Mount Installation  
The procedure for fixing the pole type system is as follows. 
Service man is mounting the same way the EZD-LICPA23 and EZS-LICPA30.  
1) To mount the system on the wall, first fix the bracket on the wanted position.  
2) Hang the system to the hooking position at the top of the mounting bracket  
3) Push the system to the hooking position at the bottom of the mounting bracket.  
Figure 13. The way to fix the bracket on the pole (Normal type) 
38 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Page 39
Cautions while drilling on the pole 
Drilling thru-hole on a center of the pole  
Cautions System leveling 
Before fixing the system, Check the horizontal and vertical level using a spirit level 
M5x12mm WRENCH BOLT, SEMS 
4) Align the system with the fixing holes of the mounting bracket and fix them firmly  
Figure 14. The way to fix firmly the System for Pole Mounting 
39 
© 2018 GS Instech Co., Ltd.  All rights reserved.    
Page 40
Port Outlook 
(System Side) 
8.3. Cable Connection  
8.3.1.  AC Power cable connection  
• Repeater supports a free AC Input voltage from 110V to 240V  
• Provided Power cable is single type, so it can be used flexibly  
• The pin description of AC Port is below. User should connect exact polarity of AC  
• The specification & Connection of AC Power Cable   
-   A: MS3106A-22-2  
-   Connect Port A for inserting AC Power  
© 2018 GS Instech Co., Ltd.  All rights reserved.    
40 
Page 41
8.3.2. Local Maintenance Connection  
• Repeater Support a RJ-45 connector  
8.3.3.  Grounding cable Connection  
• Frame(Earth) Wire size is AWG #6. The way to install the grounding cable is below  
• The specification of ground terminal lug is like below (Refer to JOCT 0202-RL05)  