GS Instech CC L13, CC P18, CC I13, CC A18 User Manual

Clear Call
User Manual
Version 1.1
GSInstech Co., Ltd
GSInstech Co., Ltd
Version
Author
Descriptions
Date
Remarks
1.0
S.H Yoo
Draft
1 Aug 2018
1.1
S.H Yoo
FCC Label
6 Sep 2018
System Installation
Version
Change List
Remarks
Change List
GSInstech Co., Ltd
Abbreviations
Abbreviation
Term Definition
Remark
AGC
Automatic Gain Control
ALC
Automatic Level Control
BTS
Base Transceiver Station
CW
Continuous Wave (un-modulated signal)
DFM
Digital Filter Module
DL
Downlink The path covered from the BTS to the subscribers
service area via the repeater
FW
Firmware
HPA
High Power Amplifier
HW
Hardware
LNA
Low Noise Amplifier
LTE
Long Term Evolution
MS
Mobile Station
PSU
Power Supply Unit
RF
Radio Frequency
RFU
Radio Frequency Drive Unit
SW
Software
UL
Uplink The path covered from the subscribers service area to
the BTS via the repeater
VSWR
Voltage Standing Wave Ratio
GSInstech Co., Ltd
FCC ID(s)
HAAT (m)
Max. Antenna again
U88CC-L13
71656.75
6 dBi
U88CC-I13
26460.60
6 dBi
U88CC-P18
26143.43
6 dBi
U88CC-A18
72828.84
6 dBi
1. FCC Mandatory
1.1 FCC Warning States
1.1.1 FCC Part 15.21
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
1.1.2 FCC Part 15.105
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
1.1.3 FCC Part 15.19
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
1.1.4 Antenna installation
. Antennas must be installed in accordance with FCC requirement.
The height of the antenna above average terrain (HAAT) must not exceed limit in the
following table.
1.1.5 Radiation Exposure Statement
GSInstech Co., Ltd
RF Radiation Exposure
This equipment complies with RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of
WARNING
Provides information or instructions that the reader should follow in order to avoid
personal injury or fatality
CAUTION
Provides information or instructions that the reader should follow in order to avoid
a service failure or damage to the system
CHECK POINT
Provides the operator with checkpoint for stable system operation
NOTE
Indicates additional information as a reference
No use for the unauthorized device
When installing the system. Must check the devices that use is authorized.
This conditions apply antenna, cable, and if necessary
20 cm between the radiator and your body. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter. RF exposure will be
addressed at time of installation and the use of higher gain antennas may require larger
separation distances.
1.1.6 FCC Warning Labels
1) FCC Part
1.2 Prohibitions
Use of unauthorized antennas, cables, and coupling devices not conform to ERP/EIRP
and indoor‐only restrictions is prohibited.
Preclude indications that home/personal use be prohibited.
1.3 Installation Warning statement
GSInstech Co., Ltd
Circuit Breaker Installation in the Box for Overcurrent Protection
Must install the circuit breaker between the system and main AC source for
separating.
Make sure to install the Circuit breaker on the place to operate easily Circuit breaker
be able to operate up to 20A
Terminal, Conduit and Cable size
To install the conduit is according to NAE regulation, and Terminal size is according
to NEC regulation
GSInstech Co., Ltd
Certification
Type
ID
Remarks
FCC
Industrial RF Repeater
U88CC-L13
700MHz
U88CC-I13
800MHz
U88CC-P18
1900MHz
U88CC-A18
2100MHz
General Information
This document is primarily written for those who are new to Clear Call system and wish to
tune up the equipment. The document is applicable to below products from GSINSTECH.
Model number: Clear Call.
1.4 Repeater Information (FCC)
1.5 Purpose
Clear Call is a repeater, which has been designed to improve signals in blanket/shadow
areas inside of buildings to transmit Provider’s variety frequencies. User may choose filtering
configuration according to the specific site circumstances. It supports 700MHz LTE, 800MHz
iDEN, 850MHz Cellular, 1900MHz PCS and 2100MHz AWS frequency with one antenna
port. The max output is 18dBm and coverage is up to 25,000 SQFT.
1.6 Advantages
It provides selectable RF power levels for any wireless technology/band 19inch rack or wall mount available depending on the installation site Modular type for each frequency up to 4 modules Can select service band through RSSI Check and control the status of the repeater through front touch LCD FPGA digital filtering provides optimized RF performance Sub band filtering: It contains three non-contiguous high rejection digital filter Quad band channel filtering, real time oscillation detect & gain control
GSInstech Co., Ltd
No
Description
Function
Remarks
1
Donor ANT Port
Antenna port for communication with BTS
4.3-10 DIN
2
Service ANT Port
Antenna port for communication with terminal/UE
4.3-10 DIN
3
Touch LCD
Display of status and select of function
2.2inch TFT LCD
4
Ethernet Port
GUI connection port for checking the status and control
RJ-45
5
Debug Port
Communication port for developer
Micro USB
6
Power Supply Port
Power supply port for each module
DC-005 jack
7
RF Unit
RF service unit
Max 4 unit
1.7 Appearance
GSInstech Co., Ltd
Item
Specification
Remark
700MHz
Down Link
728MHz ~ 757MHz
Band 12 & 13
Up Link
698MHz ~ 716MHz
Band 12
776MHz ~ 787MHz
Band 13
800MHz
Down Link
862MHz ~ 894MHz
Band 26
Up Link
817MHz ~ 849MHz
Band 26
1900MHz
Down Link
1930MHz ~ 1995MHz
Band 25
Up Link
1850MHz ~ 1915MHz
Band 25
2100MHz
Down Link
2110MHz ~ 2155MHz
Band 4
Up Link
1710MHz ~ 1755MHz
Band 4
Item
Specification
Remark
Band
700MHz
800MHz
1900MHz
2100MHz
Composite
Power
DL
13dBm
13dBm
18dBm
18dBm
UL
18dBm
18dBm
18dBm
18dBm
Gain
Range
75 ~ 45dB
80 ~ 50dB
Step
0.5dB
Accuracy
1dB
Roll-Off
-50dBc @ ±750kHz
Flatness
Single CH
≤ 4dB
Inter CH
5dB
UL Noise Figure
≤ 7dB
@ Max Gain
Group Delay
≤ 5us
Channel Select
Non-Contiguous 3Block
In/Out Port VSWR
2.0 : 1
Impedance
50Ω
Item
Specification
Remark
RF Connector
DIN (4.3-10) Type Female
AC-DC Adapter
Input : AC 90 ~ 264V, Output : DC 12V
DC Power Connector
DC-005
Size
Module
4.17 * 12.6 * 1.6inch
(106 * 321 * 40.9mm)
2. Specifications
2.1 Frequency Allocation
2.2 Common Specifications
2.3 Mechanical Spec.
GSInstech Co., Ltd
Chassis
17.2 * 18.1 * 1.75inch
(437 * 457.5 * 44.5mm)
Weight Module
< 2.98lbs (1.35Kg)
Chassis
< 19.84lbs (9Kg)
Included four modules
Operation Temperature
32 ~ 122°F (0 ~ 50°C)
Humidity
0 ~ 80%
2.4 Block Diagram