Chapter 1 Safety ..................................................................................................................................................... 4
Safety Guidelines .................................................................................................................................. 4
General Safety Statement ..................................................................................................................... 5
Safety Instructions ..................... ... .... .......................................... ... ........................................................ 6
Chapter 2 Decals .................................................................................................................................................... 8
Roof Damage Warning and Disclaimer ................................................................................................. 8
Chapter 3 Special 48' Roof Instructions ............................................................................................................ 11
48' Diameter High Wind Roof Rafter Instructions ................................................................................ 11
Roof Stiffener Detail 2.66'' Corrugation Outside Stiffener Only..................................................... 11
Special Rafter Instructions for 48' Diameter High Wind Roof ........................................................ 12
48' Diameter Eave Truss Assembly .............................................................................................. 14
48' Diameter Upper Roof Truss Assembly .................................................................................... 15
48' Diameter Middle Roof Truss Assembly ................................................................................... 16
48' Diameter Lower Roof Truss Assembly .................................................................................... 17
48' Diameter High Wind Roof Rafter .............................................................................................18
Chapter 4 Warranty .............................................................................................................................................. 21
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 3

1. Safety

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE is used to address practices not related to personal injury.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Safety Guidelines
This manual contains information that is important for you, the owner/operator, to know and understand. This information relates to protecting personal safety and preventing equipment problems. It is the responsibility of the owner/operator to inform anyone operating or working in the area of this equipment of these safety guidelines. To help you recognize this information, we use the symbols that are defined below. Please read the manual and pay attention to these sections. Failure to read this manual and its safety instructions is a misuse of the equipment and may lead to serious injury or death.
DANGER
WARNING
CAUTION
NOTICE
4 PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions
1. Safety
This product has sharp edges, which may cause serious injury. To avoid injury, handle sharp edges with caution and always use proper protective clothing and equipment.
General Safety Statement
Our foremost concern is your safety and the safety of others associated with grain handling equipment. This manual is to help you understand safe operating procedures and some problems which may be encountered by the operator and other personnel.
As owner and/or operator, you are responsible to know what requirements, hazards and precautio ns exist and inform all personnel associated with the equipment or in the area. Safety precautions may be required from the personnel. Avoid any alterations to the equipment, which may produce a very dangerous situation, where SERIOUS INJURY or DEATH may occur.
You should consider the location of the bin site relative to power line locations or electrical transmission equipment. Contact your local power company to review your installation plan or for information concerning required equipment clearance. Clearance of portable equipment that may be taken to the bin site should also be reviewed and considered. Any electrical control equipment in contact with the bin should be properly grounded and installed in accordance with National Electric Code provisions and other local or national codes.
This product is intended for the use of grain storage only. Any other use is a misuse of the product.
Sidewall bundles or sheets must be stored in a safe manner. The safest method of storing sidewall bundles is laying horizontally with the arch of the sheet upward, like a dome. Sidewall sheets stored on edge must be secured so that they cannot fall over and cause injury. Use care when handling and moving sidewall bundles.
Personnel operating or working around equipment should read this manual. This manual must be delivered with equipment to its owner. Failure to read this manual and its safety instructions is a misuse of the equipment.
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 5
1. Safety
Follow Safety Instructions
Carefully read all safety messages in this manual and safety signs on your machine. Keep signs in good condition. Replace missing or damaged safety signs. Be sure new equipment components and repair parts include the current safety signs. Replacement safety signs are available from the manufacturer.
Learn how to operate the machine and how to use controls properly. Do not let anyone operate without instruction.
Keep your machinery in proper working condition. Unauthorized modifications to the machine may impair the function and/or safety and affect machine life.
If you do not understand any part of this manual or need assistance, contact your dealer.
Read and Understand Manual
Practice Safe Maintenance
Understand service procedures before doing work. Keep area clean and dry.
Never lubricate, service, or adjust machine while it is in operation. Keep hands, feet and clothing away from rotating parts.
Keep all parts in good condition and properly installed. Fix damage immediately . Replace worn or broken p arts. Remove any built up grease oil and debris.
Maintain Equipment and Work Area
Safety Instructions
Our foremost concern is your safety and the safety of others associated with this equipment. We want to keep you as a customer. This manual is to help you understand safe operating procedures and some problems which may be encountered by the operator and other personnel.
As owner and/or operator, it is your responsibility to know what requirements, hazards and precautions exist, and to inform all personnel associated with the equipment or in the area. Safety precautions may be required from the personnel. Avoid any alterations to the equipment. Such alterations may p roduce a very dangerous situation where SERIOUS INJURY or DEATH may occur.
This equipment shall be installed in accordance with the current installation codes and applicable regulations which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made.
6 PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions
1. Safety
Prepare for Emergencies
Be prepared if fire starts. Keep a first aid kit and fire extinguisher handy. Keep emergency numbers for doctors, ambulance service,
hospital and fire department near your telephone.
Keep Emergency Equipment Quickly Accessible
Wear Protective Clothing
Wear close fitting clothing and safety equipment appropriate to the job.
Remove all jewelry.
Long hair should be tied up and back.
Safety glasses should be worn at all times to protect eyes from debris.
Wear gloves to protect your hands from sharp edges on plastic or steel parts.
Wear steel toe boots to help protect your feet from falling debris. Tuck in any loose or dangling shoe strings.
A respirator may be needed to prevent breathing potentially toxic fumes and dust.
Wear hard hat to help protect your head.
Wear appropriate fall protection equipment when working at elevations greater than six feet (6').
Eye Protection
Gloves
Steel Toe Boots
Respirator
Hard Hat
Fall Protection
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 7

2. Decals

The manufacturer does not warrant any roof damage caused by excess ive v acuum or internal pressure from fans or other air moving systems. Adequate ventilation and/or “makeup air” devices should be provided for all powered air handling systems. The manufacturer does not recommend the use of downward flow systems (suction). Severe roof damage can result from any blockage of air passages. Running fans durin g high humidity/cold weather conditions can cause air exhaust or intake ports to freeze.
Roof Damage Warning and Disclaimer
CAUTION!
Excessive vacuum (or pressure) may damage roof. Use positive aeration system. Make sure all roof vents are open and unobstructed. Start roof fans when supply fans are started. Do not operate when conditions exist that may cause roof vent icing.
DC-969
8 PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions
2. Decals
Rotating flighting will
kill or dismember.
Flowing material will
trap and suffocate.
Crusted material will
collapse and suffocate.
Keep clear of all augers. DO NOT ENTER this bin!
Failure to heed these
warnings will result in
serious injury or death.
If you must enter the bin:
1. Shut off and lock out all power.
2. Use a safety harness and safety line.
3. Station another person outside the bin.
4. Avoid the center of the bin.
5. Wear proper breathing equipment or respirator.
DC-GBC-1A
ATTENTION: The decal shown below should be present on the outside of the door cover of the 2 ring, 24" porthole door cover and the roof manway cover. If a decal has been damaged or is missing in any of these locations, contact the manufacturer for a free replacement decal.
GSI Decals
1004 E. Illinois St. Assumption, IL. 62510 Phone: 1-217-226-4421
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 9
2. Decals
Failure to heed these warnings
could result in serious injury, death,
structural damage or collapse of tank.
1. Use CENTER FLOOR OUTLET ONLY until NO grain remains above this outlet.
2. Side floor outlets to be used ONLY when above condition is satisfied.
3. Lock all side floor outlets to avoid accidental premature use.
4. See manufacturers instructions for proper use of factory supplied sidedraw (wall) discharge systems.
UNLOADING INSTRUCTIONS:
DC-GBC-2A
WARNING
DON’T
DO
ATTENTION: The decal shown below should be present on the outside of the door cover of the 2 ring, 24" porthole door cover and the roof manway cover. If a decal has been damaged or is missing in any of these locations, contact the manufacturer for a free replacement decal.
GSI Decals
1004 E. Illinois St. Assumption, IL. 62510 Phone: 1-217-226-4421
10 PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions

3. Special 48' Roof Instructions

48' Diameter High Wind Roof Rafter Instructions
Roof Stiffener Detail 2.66'' Corrugation Outside Stiffener Only
Figure 3A
NOTE: Insert corrugation spacer (S-7041) into corrugation.
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 11
3. Special 48' Roof Instructions
See detail A
on Page 13
See detail B
on Page 14
See detail C
on Page 15
See detail D
on Page 16
See detail E
on Page 17
See detail F
on Pages 18 and 19
Special Rafter Instructions for 48' Diameter High Wind Roof
The 48' diameter high wind roof comes with 16 roof rafter assemblies and 48 purlins that are not included in the 30° roof manual (PNEG-1092). Install one roof rafter per sidewall sheet. Please refer to the roof manual for the complete roof assembly details.
NOTE: Each rafter has three (3) sections.
Figure 3B
12 PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions
3. Special 48' Roof Instructions
See Pages 18 and 19 for special
instructions and hardware callouts.
Special Rafter Instructions for 48' Diameter High Wind Roof (Continued)
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 13
Figure 3C Rafter to “Z” Collar Connection
3. Special 48' Roof Instructions
48' Diameter Eave Truss Assembly
Figure 3D Rafter to Stiffener Connection
14 PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions
48' Diameter Upper Roof Truss Assembly
3. Special 48' Roof Instructions
Figure 3E Rafter Splice/Upper Purlin Connection
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 15
3. Special 48' Roof Instructions
48' Diameter Middle Roof Truss Assembly
Figure 3F Middle Purlin Connection
16 PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions
48' Diameter Lower Roof Truss Assembly
3. Special 48' Roof Instructions
Figure 3G Lower Purlin Connection
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 17
3. Special 48' Roof Instructions
48' Diameter High Wind Roof Rafter
Figure 3H Roof Panel to Rib Support Clip Connection
18 PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions
48' Diameter High Wind Roof Rafter (Continued)
3. Special 48' Roof Instructions
Figure 3I Roof Panel to Rib Support Clip Connection
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 19
NOTES
20 PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions

4. Warranty

9101239_1_CR_rev7.DOC (revised July 2009)
GSI Group, LLC Limited Warranty
The GSI Group, LLC (“GSI”) warrants products which it manufactures to be free of defects in materials and workmanship under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale, 14 months from arrival at port of discharge, whichever is earlier. The end-user’s sole remedy (and GSI’s only obligation) is to repair or replace, at GSI’s option and expense, products that in GSI’s judgment, contain a material defect in materials or workmanship. Expenses incurred by or on behalf of the end-user without prior written authorization from the GSI Warranty Group shall be the sole responsibility of the end-user.
Warranty Extensions:
The Limited Warranty period is extended for the following products:
Product Warranty Period
Performer Series Direct Drive Fan Motor 3 Years
AP Fans and Flooring
Cumberland Feeding/Watering Systems
Grain Systems Grain Bin Structural Design 5 Years Grain Systems
Farm Fans Zimmerman
All Fiberglass Housings Lifetime All Fiberglass Propellers Lifetime Feeder System Pan Assemblies 5 Years ** Feed Tubes (1-3/4" and 2.00") 10 Years * Centerless Augers 10 Years * Watering Nipples 10 Years *
Portable and Tower Dryers 2 Years Portable and Tower Dryer Frames and
Internal Infrastructure †
5 Years
* Warranty prorated from list price: 0 to 3 years - no cost to end-user 3 to 5 years - end-user pays 25% 5 to 7 years - end-user pays 50% 7 to 10 years - end-user pays 75% ** Warranty prorated from list price: 0 to 3 years - no cost to end-user 3 to 5 years - end-user pays 50%
† Motors, burner components
and moving parts not included. Portable dryer screens included. Tower dryer screens not included.
GSI further warrants that the portable and tower dryer frame and basket, excluding all auger and auger drive components, shall be free from defects in materials for a period of time beginning on the twelfth (12 and continuing until the sixtieth (60
th
) month from the date of purchase (extended warranty period). During the extended
th
) month from the date of purchase
warranty period, GSI will replace the frame or basket components that prove to be defective under normal conditions of use without charge, excluding the labor, transportation, and/or shipping costs incurred in the performance of this extended warranty.
Conditions and Limitations:
THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH ABOVE. SPECIFICALLY, GSI MAKES NO FURTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE IN CONNECTION WITH: (I) PRODUCT MANUFACTURED OR SOLD BY GSI OR (II) ANY ADVICE, INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT, REPRESENTA TIVE OR EMPLOYEE OF GSI REGARDING OR RELATED TO THE CONFIGURATION, INSTALLATION, LAYOUT, SUITABILITY FOR A PARTICULAR PURPOSE, OR DESIGN OF SUCH PRODUCTS.
GSI shall not be liable for any direct, indirect, incidental or consequential damages, including, without limitation, loss of anticipated profits or benefits. The sole and exclusive remedy is set forth in the Limited Warranty, which shall not exceed the amount paid for the product purchased. This warranty is not transferable and applies only to the original end-user. GSI shall have no obligation or responsibility for any representations or warranties made by or on behalf of any dealer, agent or distributor.
GSI assumes no responsibility for claims resulting from construction defects or unauthorized modifications to products which it manufactured. Modifications to products not specifically delineated in the manual accompanying the equipment at initial sale will void the Limited Warranty.
This Limited Warranty shall not extend to products or parts which have been damaged by negligent use, misuse, alteration, accident or which have been improperly/inadequately maintained. This Limited Warranty extends solely to products manufactured by GSI.
Prior to installation, the end-user has the responsibility to comply with federal, state and local codes which apply to the location and installation of products manufactured or sold by GSI.
PNEG-1838 Special 48' Diameter High Wind Roof Rafter Instructions 21
This equipment shall be installed in accordance with
the current installation codes and applicable
regulations which should be carefully followed in all
cases. Authorities having jurisdiction should be
consulted before installations are made.
Copyright © 2011 by GSI Group Printed in the USA
GSI Group
1004 E. Illinois St.
Assumption, IL 62510-0020
Phone: 1-217-226-4421
Fax: 1-217-226-4420
www.gsiag.com