Table of Contents
Chapter 1 General Information and Warnings ........................................................................................ 7
About this Manual ..............................................................................................................7
Text Conventions ........................................................................................................ 7
Special Messages ....................................................................................................... 7
This manual is divided into chapters by the chapter number and the large text at the top
of a page. Subsections are labeled as shown by the 1 and 1.1 headings shown above.
The names of the chapter and the next subsection level appear at the top of alternating
pages of the manual to remind you of where you are in the manual. The manual name
and page numbers appear at the bottom of the pages.
1.1.1Text Conventions
The buttons used to interface with the Eyecon are via the touch screen display. The
buttons are shown as they would be seen on the display (i.e. ).
Screen headings will appear in bold (i.e. Start-up).
Displayed messages appear in bold italic type and reflect the case of the displayed
message.
1.1 About this Manual
1.1.2Special Messages
Examples of special messages you will see in this manual are defined below. The
signal words have specific meanings to alert you to additional information or the relative
level of hazard.
DANGER!
THIS IS A DANGER SYMBOL.
DANGER MEANS THAT FAILURE TO FOLLOW SPECIFIC PRACTICES
OR PROCEDURES WILL CAUSE INJURY OR DEATH.
CAUTION!
This is a Caution symbol.
Cautions give information about procedures that, if not observed, could result
in damage to equipment or corruption to and loss of data.
NOTE: This is a Note symbol. Notes give additional and important information, hints
and tips that help you to use your product.
Eyecon Instruction Manual7
General Information and Warnings
1.2Installation
DANGER: RISK OF ELECTRICAL SHOCK. NO USER SERVICEABLE
PARTS. DO NOT ATTEMPT TO SERVICE THE EYECON BY REMOVING
THE COVER OR OPENING THE UNIT. REFER TO QUALIFIED SERVICE
PERSONNEL FOR SERVICE.
DO NOT EXPOSE THE EYECON TO RAIN OR MOISTURE. DO NOT
EXPOSE THE EYECON UNIT TO DRIPPING OR SPLASHING LIQUIDS.
CAUTION!
Class 2 laser radiation when open. Refer to page 19 for more details.
1.2.1Unpacking
Caution! The Eyecon contains components that can be damaged by rough
handling. Unpack all items carefully.
1.2.2Intended Use
Eyecon™ utilizes machine vision technology to accurately count tablets and capsules
for prescription dispensing.
Machine vision technology allows for identification of most foreign substances and pill
variations during the counting and dispensing process.
The specialized technology of the Eyecon™ does not support the counting of gel caps.
Figure 1.1 High Voltage Warning Label
8Eyecon Instruction Manual
1.2.3General Description
INTERFERENCE RECEIVED. INCLUDING INTERFERENCE
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
179400-004311
SERIAL NO. XXXXXX
std. 61010-1, 2nd Ed.
C22.2 No. 61010-1, 2nd Ed.
Conforms to ANSI/UL std.
OPERATON IS SUBJECT TO THE FOLLOWING TWO
THAT MAY CAUSE UNDESIRED OPERATION.
Certified to CSA std.
www.EyeconVPC.com
Patent Pending
AC 100-240V/47-60 Hz
Operation:
Max Power: 150W
3173012
Avery Weigh-Tronix, LLC
Refer to the diagram below for part descriptions for field replaceable and non-field
replaceable parts.
1.2 Installation
DescriptionPart Number
1Touch Screen InterfaceN/A
2Infra Red CameraN/A
3Rapid Fill Platter 249400-303A0
4Infra Red EmitterN/A
5(2) Spatula 44-70-43547R
6Clear Funnel Face 44-70-43760
7Barcode ScannerN/A
8Funnel Slide Gate 44-70-43546
9Penicillin Platter249400-301A0
Sulfa Platter249400-302A0
10Leg Assembly 249400-304A0
1.2.4Product Identification
Each Eyecon has a specific part number and a unique serial number. Please refer to
Figure 1.2.
This information will be needed for periodic updates, service, and warranty claims.
Figure 1.2 Product Markings
Eyecon Instruction Manual9
General Information and Warnings
1.3Setup
Place the Eyecon on a level surface and away from direct sunlight. Refer to Figure 1.3
for dimensions of the Eyecon.
1.3.1Sulfa and Penicillin Platter
The sulfa (yellow) and penicillin (red) platters are used to avoid cross contamination
and are standard with Model # 179400-004311. The platters store easily under the
base of the Eyecon.
The platters are also available for purchase in a kit or separately.
l When ordering both platters and hardware, use part number 249400-300A0.
l When ordering the Penicillin platter only, use part number 249400-301A0.
l When ordering the Sulfa platter only, use part number 249400-302A0.
Sulfa and Penicillin Platter Kit Installation
No need to remove leg assembly to install optional counting platter brackets.
1.Gently turn the Eyecon unit on its side being careful to not drop the Eyecon on
the display.
2.Remove adhesive tabs from platter holder located in two places per holder
(refer to Figure 1.4).
Figure 1.3 Eyecon Dimensions
3.Position one of the platter holders on the chassis with the ridges facing the
inside (refer to Figure 1.5 for an illustration).
10Eyecon Instruction Manual
1.3 Setup
ADHESIVE
4.Line the four snaps of the platter bracket up with 4 holes on chassis. Push until
holders snap into place. Holders can only be installed one way, if holes don't
line up turn holders around and try again. Apply light pressure to platter holder
for approximately 15 seconds allowing adhesive to set.
5.Carefully stand the Eyecon upright.
6.Insert the sulfa and penicillin platters in between the brackets (refer to Figure
1.6).
Figure 1.4 Platter Bracket
Figure 1.5 Platter Bracket Installation
Eyecon Instruction Manual11
General Information and Warnings
Figure 1.6 Storing Sulfa and Penicillin Platters
1.3.2External Scanner
An optional omni-directional scanner is available for mounting externally to the Eyecon
enclosure. The scanner comes with an interface cable and double-sided tape for
mounting. The kit part number is 249400-430C0.
Refer to the following photos and instructions for enabling the scanner and
recommended mounting configurations.
Mounting
1.Apply double-sided tape to bottom of scanner. Stick scanner on the Eyecon
enclosure with the scan beam pointing outward.
2.Install cable tie holder by peeling off the backing and adhering to the bottom
plate of the Eyecon.
12Eyecon Instruction Manual
1.3 Setup
3.Insert cable tie through hole of holder.
4.Plug the USB end into an available USB port on the back of the unit.
5.Bundle excess cable and pull the cable tie tight.
6.Plug the DB9 end of the cable into the scanner. Secure the cable by tightening
the two screws.
7.Plug in the scanner cable into the USB port.
8.Plug the USB end of the scanner cable into an available USB port located on
the rear of the Eyecon unit.
Eyecon Instruction Manual13
General Information and Warnings
Power
Supply
Power Switch
Fan
Enable Scanner
By default the scanner internal to the Eyecon unit is set to be the primary scanner used.
In order to use the external scanner, the internal scanner must be disabled by changing
the scanner port number within the settings menu of all modes being used.
Enable the external scanner by entering a 4 as the port number under the
General>Scanner Port setting. The Eyecon must be rebooted before the changed
setting will be saved. Refer to page 29 for instructions on setting the port number.
1.4Preparing the Eyecon for Use
1.Insert the power cable into the receptacle located in between the power switch
and fan on the back of the Eyecon. Refer to Figure 1.7.
2.The Eyecon must be installed near an easily accessible socket outlet. Plug the
Eyecon power cord into the outlet.
Figure 1.7 Power Supply
14Eyecon Instruction Manual
1.5Turn on the Eyecon
Power Push Button
USB Ports
Network Port
1.Make sure the power switch is in the ON ( I ) position. Refer to Figure 1.7 for
location.
2.Fully depress and release the power push button to turn on the Eyecon (Refer
to Figure 1.8). The display area will illuminate within a few seconds.
Do not use the power switch to turn off the Eyecon. Refer to Figure 1.7 for
power switch location. The Eyecon is designed to be turned off through the
touch screen menus. Refer to page 23 for details on shutting down the Eyecon.
If power is lost, fully depress and release the power push button to turn on the
Eyecon. Refer to Figure 1.8 for power push button location
If a network cable is to be connected plug it into the receptacle on the back. Refer to
Figure 1.8.
1.5 Turn on the Eyecon
Figure 1.8 Eyecon Back Panel
Eyecon Instruction Manual15
General Information and Warnings
1.6 Routine Maintenance
Always turn off the machine and unplug the power cord before starting any routine
maintenance to avoid the possibility of electric shock.
Make sure that it is placed securely on a flat and level surface.
1.7Cleaning the Machine
Be sure to keep the Eyecon unit clean and free of dust. Do not use harsh detergents or
spray water on the Eyecon unit.
It is recommended the Eyecon unit be cleaned on a daily basis. Powder and pill dust
tends to accumulate on surfaces such as the rapid fill tray and funnel gate. Follow the
steps below for effective cleaning.
1.7.1Funnel and Slide Gate
1.Slide the gate up while pulling out away from the housing as shown in the photo
below.
2.Clean the clear funnel gate by running it under a faucet. Make sure it is
completely dry before reattaching to housing.
16Eyecon Instruction Manual
3.Clean the pill funnel by running a slightly damp rag through it a few times.
4.Clean the funnel gate bracket rails to remove all pill dust.
5.Reinstall the funnel gate by sliding down the funnel post until it snaps into
place.
1.7.2Rapid Fill Counting Tray
1.7 Cleaning the Machine
1.Lift the counting tray up to a vertical position.
2.Tilt the tray to the left, the right side should pull out of the enclosure.
Eyecon Instruction Manual17
General Information and Warnings
3.Pull up on the tray to remove completely.
4.Clean the tray by running under a faucet. Make sure it is completely dry before
5.Before reinstalling the tray, clean the diffuser surface under the tray with a soft
reattaching to housing.
damp cloth.
6.Reinstall rapid fill tray onto Eyecon unit by holding the tray vertical and push it
into the slots in the housing.
1.8Sharp Objects
Do not use sharp objects such as screwdrivers or long fingernails to operate the
buttons.
1.9Training
Do not attempt to operate or complete any procedure on the Eyecon unless you have
received the appropriate training or read the Instruction Manual.
To avoid the risk of RSI (Repetitive Strain Injury), place the machine on a surface which
is ergonomically satisfactory to the user. Take frequent breaks during prolonged usage.
18Eyecon Instruction Manual
1.10Scanner / Laser
CAUTION -
CLASS 2 LASER RADIATION
WHEN OPEN. DO NOT STARE
INTO THE BEAM
The Eyecon comes standard with a Class 1 laser product. When the unit is open Class
2 laser radiation is present. Refer to the CAUTION statement below and Figure 1.9 for
an illustration of the label and location.
CAUTION: Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation exposure.
CAUTION: Class 2 laser radiation when open. Do not stare into the beam.
1.10 Scanner / Laser
Figure 1.9 Class 2 Laser Radiation Warning Label Location
1.10.1Scanner Specifications
External
Laser Radiation 15.47 µWClass 1
Wavelength650 nm
Internal Laser Rating
Wavelength650 nmClass 2
Max Output Power460 µW
Eyecon Instruction Manual19
General Information and Warnings
1.11Licensing Agreement
When the Eyecon is powered up for the first time a Software Product Licensing
Agreement will be displayed after a pharmacy package is chosen.
Before the Eyecon can be used, you must
agree to the terms of the license.
1.Read the agreement thoroughly and
agree to the terms by pressing the
button.
1a.If the button was pressed, a
warning screen will be displayed.
Press the button to
return to the Licensing
Agreement.
Press the button to
turn off the Eyecon.
1.11.1Medi-Span Copyright and Disclaimer Information
All rights reserved. The Master Drug Data Base (MDDB v2.5) Documentation Manual
and the database supplied with it may not be reproduced in any form or by any means,
in whole or in part, without written consent from the publisher. Any unauthorized use of
this copyrighted material will be subject to legal action.
Medi-Span is a division of Wolters Kluwer Health, Inc.
Master Drug Data Base (MDDB®) is a registered trademark of Wolters Kluwer Health,
Inc.
All rights reserved. The Drug Image Database Documentation Manual and the
database supplied with it may not be reproduced in any form or by any means, in whole
or in part, without written consent from the publisher. Any unauthorized use of this
copyrighted material will be subject to legal action.
Disclaimer: The information contained in the Medi-Span databases is intended to
supplement the knowledge of physicians, pharmacists, and other healthcare
professionals regarding drug therapy problems and patient counseling information.
This information is advisory only and is not intended to replace sound clinical judgment
in the delivery of healthcare services. You are advised to review the definitions,
functionality, and limitations of each Medi-Span database.
Medi-Span disclaims all warranties, whether expressed or implied, including any
warranty as to the quality, accuracy, and suitability of this information for any purpose.
20Eyecon Instruction Manual
1.12Software Updates
The software must be updated quarterly to uphold the Licensing Agreement. Download
the software update from www.eyeconvpc.com. These updates are comprised of drug
photo updates and application enhancements.
It is suggested to download the file(s) to a computer desktop and then transfer the
file(s) to a USB memory stick.
1.12.1Update Warnings
Warnings will be provided when the expiration date on the data has passed. Warning
interval will be dependent on the length of time since the expiration date has passed.
1st week post expiration:One warning per day.
2nd week post expiration:One warning per 4 hours.
3rd week post expiration:One warning per hour.
Beyond 3rd week post expiration:One warning per entering count mode.
1.12 Software Updates
Table 1.1 Update Warning Frequency
1.12.2Install Software Updates
1.Download the latest software updates from the Eyecon website
(eyeconvpc.com).
2.Copy the downloaded file to the root folder of a USB memory stick. Be sure the
memory stick does not contain an older version of an update file before
copying the current update file.
3.Plug the USB memory stick into an unoccupied USB port of the Eyecon. See
Figure 1.10 for USB port location.
Figure 1.10 USB memory stick Installation
4.Follow the prompts displayed on the Eyecon.
Eyecon Instruction Manual21
General Information and Warnings
4a.If the following message is displayed, click No. This message is an indication
4b.Answer Yes if the following prompt appears.
4c.If no message appears when the USB memory stick is plugged in, then follow
that the particular USB memory stick type inserted is new to this Eyecon.
the instructions below.
Stand-Alone Mode
l Go to Settings>Files
l The update prompts should be displayed within a few seconds.
5.First you will see a message advising the outdated files are being removed.
6.Next a progress bar will advance quickly from 0 to 100% while the integrity of
the update file is verified.
7.Another progress bar will advance more slowly while the updates are installed.
8.Once the installation is complete, click the [Close] button.
9.The Eyecon should shut down and restart within a minute or so.
9a.If the Eyecon does not automatically restart, manually shut the Eyecon down
by using the button on the screen. DO NOT USE THE SWITCHES IN THE BACK TO SHUTDOWN THE EYECON!!!
22Eyecon Instruction Manual
1.13Turn off the Eyecon (Shutdown)
Do not unplug or shutdown the Eyecon with the power switch on the backside
of the unit. This could cause corruption of files which would require the Eyecon
to be returned for factory service.
The button in the Start-up screen is used
for restarting or turning off the Eyecon.
Again it is very important to use the
button to turn off the Eyecon. DO NOT USE THE
POWER SWITCHES IN THE BACK TO TURN OF
THE EYECON UNIT.
1.13.1Restart
1.13 Turn off the Eyecon (Shutdown)
1.Press the button in order to initialize a reboot sequence and return to
the Start-up screen.
2.Press to accept.
1.13.2Shutdown
1.Press the button to turn off the Eyecon. Press to accept.
2.Press to terminate the process.
1.14About Eyecon Screen
The About Eyecon screen provides
information specific to the Eyecon. Including
software release date, serial number and MediSpan data.
1.While in Eyecon Native mode Start-up
screen, press in the area right or left of
the Eyecon by GSE logo.
2.Press to return to the Start-up
screen or press to view the
Software Licensing Agreement.
Eyecon Instruction Manual23
General Information and Warnings
1.15Warranty Policy
GSE/Avery Weigh-Tronix warrants its products to be free from defects in material and
workmanship for a period of two (2) years from the original date of purchase. Standard
"Terms and Conditions of Sale" apply.
Factory parts and labor are provided at no charge for up to two full years from the
original date of purchase.
The obligation of GSE is limited to repairing or replacing equipment and components
that upon inspection, testing and verification by GSE are found defective. GSE extends
this warranty only upon proper installation and use of the equipment in the application
for which it was intended and does not warranty equipment that has been subject to
any of the following conditions:
l Alterations, misuse or unusual physical or electrical stress beyond the
written specifications of that equipment.
l Exposure of electronic components to Electrostatic Discharge (ESD)
resulting from improper handling or installation.
l Damage caused by freight carriers, negligence, fire, flood or other natural
disaster.
In the event, equipment is repaired or replaced under the terms of the warranty, the
warranty of the repaired or replaced equipment is limited to the remaining portion of the
original warranty period or 90 days, whichever is greater.
GSE is responsible for repair, replacement or, at the sole discretion of GSE, credit of
nonconforming equipment under the conditions and terms of this warranty. GSE is not
liable for the cost of repairs, on-site labor or any travel-related expenses performed by
another party unless otherwise agreed in writing.
Transportation charges for material shipped to GSE for warranty repair is paid by the
shipper. GSE will pay the transportation charges, via standard carrier, for the return of
items repaired or replaced under warranty. Failure to handle and ship equipment
correctly will void the warranty on that equipment.
The sole remedy under this warranty is to repair, replace or provide credit for equipment
at the sole discretion of GSE. GSE is not liable for expenses either direct or
consequential that arise from the use of or inability to use the product. GSE is not
responsible or liable for losses, injury, or property damage due to the installation or
failure of the product.
For warranty, product service, and product registration visit www.eyeconvpc.com or call
866-260-6540.
24Eyecon Instruction Manual
1.16Specifications
Platter Surface Area48 sq inch
Dimensions28" H x 11" W x 17.5" D
Screen 6.5" Color LCD flat panel touch screen
Barcode Scanner
1.16 Specifications
Integrated Class1laser
listed symbologies
Supply Voltage100 VAC - 240 VAC
Frequency Range 47 Hz - 63 Hz
Power150 Watt
Temperature Range50 - 90 ºf
Communication(2) USB, (1) Ethernet
InterfaceContact GSE for details on workflow integration
Accuracy99.97% count accuracy
DesignOpen flow, easy to clean
ApprovalsFCC, ETL
WarrantyTwo year limited
1.17FCC Statement
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
a commercial environment.
UPC/EAN, Code 39, 1 2 of 5
1.18ETL
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area may cause harmful interference in
which case the user will be required to correct the interference at his/her own expense.
Classified to IEC 60825-1: 2007
Eyecon Instruction Manual25
General Information and Warnings
1.19Back up the Eyecon Data
CAUTION!
The Eyecon is a computer based device and it is strongly suggested to back up
all transaction data and images periodically. Otherwise saved data can be
permanently lost!!!.
Refer to page 42 for more details on backing up report data and images.
1.20Helpful Hints
1.20.1Navigating the Touch Screen
Use the tip of one of the provided spatulas to navigate the settings menus and counting
procedure.
1.20.2Automatic Update from the Website
If the Eyecon is connected to a network in which automatic update is approved, the
updated software can be loaded directly onto the Eyecon without using a USB drive.
1.21Symphony Software
If you have a legacy unit and work with Symphony Software, contact Innovation
Company for technical support.
26Eyecon Instruction Manual
2Settings Menu
Press the button from the Start-Up screen to enter the setting choices menu.
The currently selected setting tab will be designated in BLUE. The following menus are
available for diagnostics and configuration.
TabDescriptionPage
GeneralMiscellaneous settings27
UsersAdd and delete user profiles30
TestTest the scanner, camera and other hardware such as the touch screen and speaker34
BarcodeSetup barcode format, select barcode type35
DataDownload or delete report data.42
FilesSave all Eyecon data, restore Eyecon data or check for update48
TCP/IPNetwork settings, select PMSS provider51
Remote ServerSet server protocol and McKesson Enterprises configuration53
MultiUsed for VA sites only. Future Feature55
Double CheckSetup double counts or back counts. 55
2.1 General
Table 2.1 List of Setting Tabs
2.1General
This tab is used for calibrating the pill counting platter, user login, stock bottle
verification, scanner port and set time & date. If another menu is desired simply press
the corresponding tab on the screen.
Auto Close Transaction Recorded Message
If this box is checked, the Auto Close
Transaction Recorded Message will be skipped
when a count is performed.
Uncheck the box to enable the Transaction
recorded message. This message will appear after
every counting transaction. Press after the
pills have been removed from the counting tray.
Eyecon Instruction Manual27
Settings Menu
Skip User Login
Check the box to disable (skip) the Scan User
Login screen and go directly to the Scan Vial
Label screen. If disabled, no users will be able
to login.
Pharmacy Package Selection
Choose whether to display the Configure
Pharmacy Package screen on restart or boot
up.
If the box is checked the screen will be shown
on power up. Otherwise the screen will be
skipped and the currently selected package will
be accessed.
Calibrate Platter
This function is used to calibrate the counting
platter viewing area if the count is unstable.
1.Remove all foreign objects from the
counting platter.
2.Press the button and the platter
will be automatically calibrated by the
software.
3.Platter calibration successful will be
displayed when the calibration is
complete.
4.Press to complete calibration.
If Unable to calibrate message appears, clean surface of counting platter and light
diffuser. Try the Calibrate Platter process again.
28Eyecon Instruction Manual
GPI Substitution
Choose whether to allow a user to substitute an
NDC that does not match the prescribed NDC
if the GPI code of the scanned NDC matches
the GPI of the prescribed NDC.
If GPI Substitution is set to Disabled, the
substitution is not allowed.
If GPI Substitution is set to Enabled, the
substitution is allowed.
If GPI Substitution is set to NoWarning, the
substitution is allowed with a warning message
being displayed.
Stock Bottle Verification
Choose whether to verify a stock bottle scan
every time, never or per user.
l If Stock Bottle Verification is set to
Always, the Scan Stock Bottle
screen will appear every time the Rx
label is scanned.
l If Stock Bottle Verification is set to
Never, the Scan Stock Bottle
screen will never appear after the Rx
label is scanned and will go to the
Counting screen.
l If Stock Bottle Verification is set to User, scan the stock bottleto proceed
or press the button to proceed to the Counting screen.
2.1 General
Scanner Port
Selects the port for either the internal or
external scanner. The Eyecon must be
restarted before the port change will take
affect.
Use the keyboard icon button to the right of the
scanner port window to enter the port number.
2 = internal scanner
4 = external scanner
Eyecon Instruction Manual29
Settings Menu
2.1.1Launch Windows Applications
Date and Time
The time and date may be set by pressing the
button. Choose the correct time and
date from the calendar and clock displayed.
Press to accept the current settings or
changed values. Press to abort.
Windows Explorer and Control Panel
The choices available are Windows Explorer
and Control Panel. These will work the same as
standard Windows operating system. Press the
or button to launch either
application.
2.2Users
The Administrative section used for adding and
deleting users, determine whether a scan-out
will be necessary or to allow the use of an
RDAC. Only available with the Rx Validation/Workflow and Physical Inventory modes.
The administrator is able to add or delete users
and determine whether they are able to train pill
images. An access code is required to enter the
Administrative screens.
To enable User Logging, go to the General Tab and uncheck the Skip User Login box.