GSD Wi-Corporate Controller Installation & User Manual

Installation & User Manual V2.07
3
Contents
6
Installation Diagrams
9
8
System Overview
Wi-Corporate Controller
Other products from GSD
4
12
Network Diagrams
Wiring Diagrams
19
Fingerprint Enrollment
Operation Instructions
Global Security Devices Ltd: No.3 Broomhill Business Complex, Tallaght,
Dublin 24, Ireland, Phone: +353 (1) 524 2691, Email: info@globalsecurity.ie
www.globalsecurity.ie
YOUR SECURITY IS OUR PRIORITY
2
3
Technical Specification
Power Supply 230 VAC Current consumption 30mA Fuse Rating 230VAC 315mA T Moisture Resistance Indoor Use Only Dimensions W. 260mm D. 262mm H. 55mm
Technical Specs - GSD Wi-Corporate Controller
Power Supply 12 DC Current consumption 110mA Current consumption with load (max) 145mA Relay Contact Rating 5 Amps /230V ac Operating Temperature - 20 C to +60 C Moisture Resistance IP 67 ( IP65 on Wi-Bio ) Dimensions - Flush Mount W. 87mm D. 21mm H. 119mm
- Surface Mount W. 87mm D. 35mm H. 119mm
Technical Specs - Wi-
Corporate
Door Controls
Features
Doors controlled Users User Groups Time Zones Door Groups Reporting Facility Challenge Facility Logging Input/Output Mapping Supports Wireless & RS485 Networks Automatic Backup Facility Database Encryption * 30000 individual usergroups are available
20
30000
128*
128 128
Yes Yes
Unlimited
CCTV & Lift control
Yes Yes Yes
Installation Steps
Step Description Page
1 Install the Controller using the Installation Diagrams 4-5
2 Wire the Controller using the Wiring Diagrams 8
3 Install and wire each Door Control. Refer to the Door Control Manual for instructions.
4 Connect the Controller to the PC using Network Diagrams 9-11
5 Restoring Factory Defaults 11
6 Setting up TCP-IP 12
6 Phase 1- Setting up the GSD Controller 14
7 Phase 2 - Configuring the GSD Controller 15
8 Phase 3 - Enrolling Door Controls 16-18
9 Phase 4 - Configuring Users 19
10 Phase 5 - Configuring Access Levels 20
11 Phase 6 - Downloading Configuration 20
12 Enrolling User Fingerprints 21
13 Correct Finger Placement techniques 22-25
Installation Steps
Control Panel opening
Control Panel features
remove screw cap
remove retaining screw
to remove cover pull forward on right and slide left
mount with 4 x 1.5 inch No. 8 Security Type screws
rear tamper switch
cable entry
cable entry
cable entry
cable entry
spare cap
access to rear void for wiring
spirit level
mains pcb
mount holemount hole
mount hole
4
Installation Diagrams
5
Installation Diagrams
6
System Overview
Wireless Connection to Door Controls
Door Control #1
Door Control #2
Door Control #3
Door Control #5 - 20
TCP-IP connection to Controllers or RS485 Network to Controllers Max number of Controllers 3 Max Cable Length 1.4 km
Controller #1
Controller
#2 - 3
Door Control #4
Note: Door Controls can be installed within 30 meters of the Controller or within 30 meters of any other Door Control as each Door Control will function as a repeater. Each Door Control transmits data to/from the Controller. These distances are a guideline. The actual communication range depends on building shape and construction methods used.
7
System Overview
Note: If using a single Controller, an RS232 cable may be used. Max cable length 10 meters
RS485 Connection to Door Controls
Door Control #1
Door Control #2
Door Control #3
Door Control #4 - 20
RS485 Network to Door Controls Max Cable Length 1.4 km. Daisy Chain Configuration Only.
Controller #1
Controller
#2 - 3
Note: If using a single Controller, an RS232 cable may be used. Max cable length 10 meters
Place a 120ohm Termination Resistor across A & B on the last Door Control in the chain.
Place a 120ohm Termination Resistor across A & B on the Controller
TCP-IP connection to Controllers or RS485 Network to Controllers Max number of Controllers 3 Max Cable Length 1.4 km
Note : Used ONLY for Wired 485 Network Connections.
ABCOM
TX
RX
PC Network
PC Direct
PC Network Connections can be used for multiple controllers See page 10 for wiring
Wiring Diagrams
8
Wiring Diagrams
Door Network
A
B
COM
1 2 3 4
OFF
ON
TCP_IP
3V Lithium
Inputs/outputs
IP1 IP2 0V IP3 IP4 12V OP1 OP2
OP3 OP4 0V VOUT DAT CLK SEN
Inputs/outputs
Cable Tie
Fuse Rating : 230VAC 315mA
Warning : Installation should only be carried out by a suitably qualified person only.
Cable Tie retaining clips
Main Input Cable 230VAC
Neutral Earth
Live
Remove Battery Tab
Pull
9
Network Diagrams for Single Controller
A B 0V TX RX
A B 0V
Door Network
PC Network
Connect DB9 cable to serial port on PC
Maximum cable length 10 meters
Direct Connect - All Dip Switches OFF
PC Direct
DB9 Female Serial Cable
PC Direct Connection can be used, when using ONLY one GSD Controller.
Set the Direct address to ALL dip switches OFF (see below )
Network Diagrams
OFF
ON
1 2 3 4
1
5
2 3 4
9
8
7
6
See page 11 on “Configuring GSD Controller Communication” to setup the application for serial communications