GSD 2 Door Pin and Proximity Installation & User Manual

Installation & User Manual V1.00
2
Operation Instructions
Contents
6
Installation Diagrams
8
Wiring Diagrams
18
17
Quick Reference
2 Door Pin and Proximity
Other products from GSD
“Wireless Network
System”
GSD Wi-Enterprise/Wi-Plus System is the
next generation in access control solutions. It provides a Wireless Network throughout the premises, giving the convenience and security of a fully networked system for a fraction of the cost.
For more information on the Wireless Network System visit our
website www.globalsecurity.ie
Global Security Devices Ltd: No.3 Broomhill Business Complex, Tallaght,
Dublin 24, Ireland, Phone: +353 (1) 524 2691, Email: info@globalsecurity.ie
www.globalsecurity.ie
YOUR SECURITY IS OUR PRIORITY
Factory Default PIN codes
The following PIN codes are the Factory Default Settings:
- User PIN ‘1111’ will grant access on door 1
- User PIN ‘2222’ will grant access on door 2
- The Default Engineer code is ‘6666’
Note: These User PINs (’1111’,’2222’) are deactivated when the first User PIN is added to the keypad.
2
Operation Instructions
Technical Specs
Power Supply 12 - 24V AC or DC Current consumption 100mA Current consumption with load (max) 130mA Relay Contact Rating 5 Amps /240V ac Operating Temperature - 20 C to +60 C Moisture Resistance IP 67 Dimensions - Flush Mount W. 87mm D. 21mm H. 119mm
- Surface Mount W. 87mm D. 35mm H. 119mm
Number of Users 1000
Restoring Factory Settings
Code Description 55 Restore Factory Default Settings
Example:
X key then
Engineer
Code
+ +
Code = 55
Note: If Engineer code is lost, Remove the Security Caps (see page 11) and hold down the X key during power-up and enter the default Engineer code ‘6666’ immediately. This will restore the factory settings.
3
Operation Instructions
Example: To Add User PIN ‘5656' to Door 1..
Example: To Remove User PIN ‘4545’ from any door..
Example: To Add Toggle User PIN ‘1234’ to Door 2..
Example: To Add Manager User PIN ‘5678’ to Door 2..
Adding and Removing User PINs
Code Description 01 Add a Standard User/Toggle User/Manager User PIN to Door 1 02 Add a Standard User/Toggle User/Manager User PIN to Door 2 03 Remove any User PIN
X key then
Engineer
Code
+ +
Code = 01
+
PIN = 5656
X key then
Engineer
Code
+ +
Code = 03
+
PIN = 4545
X key then
Engineer
Code
+ +
Code = 02
+
X key then
Engineer
Code
+ +
Code = 02
+
PIN = 5678
PIN = 1234
1
2
1 = Toggle User
2 = Manager User
4
Operation Instructions
Adding a Batch of Cards or Fobs
Code Description 04 Add Batch of Standard Cards/Toggle Cards/Manager Cards Door 1 44 Add Batch of Standard Cards/Toggle Cards/Manager Cards Door 2
+
Example: To Add a Single Standard Card...
Example: To Add a Batch of Standard Cards...
Example: To Add a Batch of Toggle Cards...
Example: To Add a Batch of Manager User Cards...
+
Present
new card again
To Confirm Standard Card
Present
new card
X key then
Engineer
Code
+
Code = 04
+
+ +
Present Last
Card in Batch
To Confirm Standard Cards
Present First Card in batch
X key then
Engineer
Code
+
Code = 04
+
+ +
Present Last
Card in batch
To Confirm Toggle Cards
Present First Card in batch
X key then
Engineer
Code
+
Code = 04
+
1
+ +
Present Last
Card in batch
To Confirm Manager User Cards
Present First Card in batch
X key then
Engineer
Code
+
Code = 04
+
2
5
Operation Instructions
Adding User Cards or Fobs using Keypad
Code Description 06 Add Batch of Cards using Keypad Door 1 46 Add Batch of Cards using Keypad Door 2
+
Example: To Add a Single Standard Card... (Card number = 00001234)
Example: To Add a Batch of Standard Cards... (Batch = 0000200 to 0001000)
Example: To Add a Batch of Toggle Cards... (Batch = 0003200 to 0004000)
Example: To Add a Batch of Manager User Cards... (Batch = 001200 to 001250)
To Confirm Card #
X key then
Engineer
Code
+
Code = 06
+
1234 =
Card number
+
1234 =
Card number
+
To Confirm Standard Card
+
To Confirm Card #
+
To Confirm Card #
X key then
Engineer
Code
+
Code = 06
+
200 =
Card number
+
1000 =
Card number
+
To Confirm Standard Cards
+
To Confirm Card #
+
To Confirm Card #
X key then
Engineer
Code
+
Code = 06
+
3200 =
Card number
+
4000 =
Card number
+
To Confirm Toggle Card
+
To Confirm Card #
1
+
To Confirm Card #
X key then
Engineer
Code
+
Code = 06
+
1200 =
Card number
+
1250 =
Card number
+
To Confirm Manager User Card
+
To Confirm Card #
2
Loading...