Grundfos UPS 15-35, UP 26-120U, UP 15-100F, UP 26-116 Installation And Operating Instructions Manual

GRUNDFOS INSTRUCTIONS
UP Series circulators
®
Installation and operating instructions
UP15 and UP26
Stainless and Bronze
English (US)
English (US) Installation and operating instructions
Original installation and operating instructions
CONTENTS
Page
1. Limited warranty
UPS 15, 26, 43 circulator pumps manufactured by GRUNDFOS PUMPS CORPORATION (GRUNDFOS) are warranted to the original user only to be free of defects in material and workmanship for a period of 36 months from date of manufacture. GRUNDFOS' liability under this warranty shall be limited to repairing or replacing at GRUNDFOS' option, without charge, F.O.B. GRUNDFOS' factory or authorized service station. GRUNDFOS will not
be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim.
All other UP and UPS small circulators manufactured by GRUNDFOS PUMPS CORPORATION (GRUNDFOS) are warranted to the original user only to be free of defects in material and workmanship for a period of 24 months from date of installation, but not more than 30 months from date of manufacture. GRUNDFOS' liability under this warranty shall be limited to repairing or replacing at GRUNDFOS' option, without charge, F.O.B. GRUNDFOS' factory or authorized service station, any product of GRUNDFOS manufacture. GRUNDFOS will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by GRUNDFOS are subject to the warranty provided by the manufacturer of said products and not by GRUNDFOS' warranty.
GRUNDFOS will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with GRUNDFOS' printed installation and operation instructions.
To obtain service under this warranty, the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise provided, the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions. Any defective product to be returned to the factory or service station must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Authorization must be included if so instructed.
GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLATION, USE, OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limitations on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction.
1. Limited warranty
1 0
2. Symbols used in this document
1 1
3. Product description
1 1
3.1 Introduction 1 1
3.2 Delivery and handling 1 1
3.3 Pre-installation checklist 1 1
4. Installation
1 3
4.1 Position of the terminal box 1 3
4.2 How to change the terminal box
position
1 3
4.3 Installation requirements 1 3
5. Electrical installation
1 4
5.1 For all 115 V and 230 V models 1 4
6. Startup
1 5
7. Operation
1 5
8. Troubleshooting
1 5
8.1 Failure to operate 1 5
9. Disposal
1 5
WARNING
Prior to installation, read these installation and operating instructions. Installation and operation must comply with local regulations and accepted codes of good practice.
11
English (US)
2. Symbols used in this document
3. Product description
3.1 Introduction
Grundfos pumps are carefully inspected and tested before shipment. This pump should provide long, efficient, trouble-free performance. To ensure maximum performance and reliability, please follow the simple instructions in this manual.
When installing this pump, always follow basic safety precautions and any federal, state, and local requirements.
3.2 Delivery and handling
Examine the components carefully to make sure no damage has occurred to the pump during shipment. Take care to ensure the pump is NOT dropped or mishandled; dropping will damage the pump.
3.3 Pre-installation checklist
Before beginning installation procedures, the following checks should be made. They are all important for proper installation of the circulator pump.
3.3.1 Applications
Model UP(S)15, 26, 43 and 50 series pumps are generally designed to circulate water from +32 °F to +230 °F (0 °C to +110 °C) up to a maximum pressure of 150 psi (10 bar). Some models have temperature limitations which are shown in Table A below. If required, a 50 % by volume solution of ethylene or propylene glycol and water can be used; however, a decrease in pump performance may result due to an increase in the viscosity of the solution. Check with manufacturer for information regarding suitability of pumping other liquids.
Closed systems
Model UP(S) 15, 26, 43 and 50 series pumps with cast iron pump housings are designed to pump water compatible with their cast iron construction. They are recommended for use in closed hydronic systems (i.e. airless, non­potable water).
Open systems
Model UP(S) 15, 26, 43 and 50 series pumps with stainless steel or bronze pump housings are designed to pump water compatible with their construction and can be used in both open and closed systems.
3.3.2 Maximum water temperature
The maximum allowable water temperature is determined by the ambient or surrounding air temperature as shown in Table A.
WARNING
If these safety instructions are not observed, it may result in personal injury.
WARNING
If these instructions are not observed, it may lead to electric shock with consequent risk of serious personal injury or death.
Caution
CAUTION
If these safety instructions are not observed, it may result in malfunction or damage to the equipment.
Note
Notes or instructions that make the job easier and ensure safe operation.
Loading...