CONGRATULATIONS!
You are now the fortunate owner of a Grundfos Variable Speed PUMP. It has been carefully
inspected and tested before shipment. It should give you long, efficient, trouble-free service. For maximum performance and reliability, please follow the simple instructions in this manual.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
The installer must ensure that this control and its wiring are isolated and/or shielded from strong sources of electromagnetic noise. Conversely, this Class B digital apparatus complies with Part 15 of the FCC Rules and meets all requirements of the Canadian Interference-Causing Equipment Regulations. However, if this control does cause harmful interference to radio or television reception, which can be determined by turning the control off and on, the user is encouraged to try to correct the interference by reorienting or relocating the receiving antenna, relocating the receiver with respect to this control, and/or connecting the control to a different circuit from that to which the receiver is connected.
CAUTION: The non-metallic enclosure does not provide grounding between conduit connections. Use grounding type bushings and jumper wires.
CAUTION: Improper installation and operation of
this control could result in damage to the equip­ment and possibly even personal injury. It is your responsibility to ensure that this control is safely installed according to all applicable codes and standards. This electronic control is not intended for use as a primary limit control. Other controls that are intended and certified as safety limits must be placed into the control circuit.
Page 1
1. Shipment Inspection
Check the contents of this package. Care should be taken to ensure the pump is NOT dropped or mishandled; dropping will damage the pump.
Grundfos Variable Speed Pump Package Includes:
One Grundfos UP15-42 Variable Speed pump with integral control or one Grundfos UP26 Variable Speed pump with integral control.
One 6’ line cord with 115 V plug, pre-wired into control unit.
Two flange gaskets
Installation and Operating Instructions.
2. General
All minimum and maximum settings are operating, not safety limits. Necessary auxiliary equipment and safety devices must be added.
Offset dial provides fine tuning for input signal.
Manual % dial provides manual speed control.
Range of signal is selected through dip switch A.
Type of signal used is selected through dip switch B.
Minimum speed at 0 or 15% is selected through dip switch C.
Speed control from external signal or manual % dial is selected through dip switch D.
Pump Exercising: After every three days of no operation, the control will exercise the pump for 10 seconds. The % Out LED will be on during exercising.
As variable speed output modulates, the control flashes the % out LED on for ¼ second and off for ¼ to 2 1/2 seconds.
The % output is run at 100% for 3 seconds after power up reset for all modes of operation.
Page 2
3. Operational Limits
Control Signal Input Range
Voltage signal range: 0-10V(DC) or 2-10V(DC) Current signal range: 0-20mA or 4-20mA
Grundfos Variable Speed pumps are designed to pump liquids compatible with their cast iron pump housing construction. They are recommended for use in closed hydronic systems. Grunfos Variable Speed pumps are for Indoor Use Only.
Grundfos Variable Speed Pumps are intended for use with water, or a 50/50 mixture by weight of propylene glycol.
UP15-42F/VS 115V 60 Hz Variable Speed Pump
Maximum fluid temperature: 205°F (96°C)
Maximum ambient:
Maximum Working Pressure: 145 PSI Minimum Inlet Pressure: 5 PSI
UP26-96F/VS 115V 60HZ Variable Speed Pump UP26-64F/VS 115V 60HZ Variable Speed Pump
Maximum fluid temperature: 195°F (90°C)
Maximum ambient:
Maximum Working Pressure: 145 PSI Minimum Inlet Pressure: 5 PSI
Page 3
• 115°F (46°C) with control module vertical (Fig. 4a).
• 115°F (46°C) with control module under pump and horizontal (Fig. 4B).
• 105°F (40°C) with control module on top of pump and horizontal (Fig 4B).
• 105°F (40°C) with control module vertical (Fig. 4A).
• 105°F (40°C) with control module under pump and horizontal (Fig. 4B).
• 92°F (33°C) with control module on top of pump and horizontal (Fig. 4B).
Loading...