Grundfos Sololift2 WC-1, Sololift2 WC-3 Installation And Operating Instructions Manual

Sololift2 WC-1, WC-3
Installation and operating instructions
GRUNDFOS INSTRUCTIONS
Other languages
Sololift2 WC-1, WC-3
http://net.grundfos.com/qr/i/97771615

English (GB)

Original installation and operating instructions
These installation and operating instructions describe Grundfos Sololift WC-1 and WC-3.
Sections 1-3 give the information necessary to be able to unpack, install and start up the product in a safe way.
Sections 4-8 give important information about the product, as well as information on service, fault finding and disposal of the product.

1. General information

1.1 Symbols used in this document

1.1.1 Warnings against hazards involving risk of
CONTENTS
Page
1. General information
1.1 Symbols used in this document
2. Receiving the product
2.1 Transporting the product
3. Installing the product
3.1 Mechanical installation
3.2 Electrical connection
4. Product introduction
4.1 Product description
4.2 Intented use
4.3 Pumped liquids
5. Servicing the product
5.1 Service documentation
5.2 Maintenance
5.3 Adjustment of run time
5.4 Service instructions
6. Fault finding the product
7. Technical data
8. Disposal of the product
2
2
3
3
3
3 3
4
1.1.2 Other important notes
4 4 4
4
4 4 4 5
6
7
7
death or personal injury
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious personal injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious personal injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate personal injury.
A blue or grey circle with a white graphical symbol indicates that an action must be taken.
A red or grey circle with a diagonal bar, possibly with a black graphical symbol, indicates that an action must not be taken or must be stopped.
Tips and advice that make the work easier.
Read this document before installing the product. Installation and operation must comply with local regulations and accepted codes of good practice.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
2

2. Receiving the product

3.2 Electrical connection

2.1 Transporting the product

WARNING
Crushing hazard
Death or serious personal injury
- Stack maximum two pallets together under transportation.

3. Installing the product

Installation must be carried out by specially trained persons and according to local regulations.
Do not pull or lift the product by the power supply cable.

3.1 Mechanical installation

The product must be accessible for maintenance and repair.
The product must be placed in a frost-free room to prevent the pumped liquid from freezing.
Make sure that all external pipes are adequately insulated.
The outlet pipe must be made of rigid material, such as copper, or of rigid PVC with solvent-welded joints.
To prevent the transmission of vibrations to buildings, make sure that the pipes are thoroughly fixed and that fittings cannot move and are not in contact with building parts.
An alarm device for acoustic alarm in case of malfunction or high level in the tank is available as an accessory (noise level 75 dB(A)).
Product number: 97772315.
Electrical connection must be carried out by an authorized electrician.
WARNING
Electric shock
Death or serious personal injury
- Make sure that the protective earth from the socket outlet is connected to the protective earth in the pump. Make sure that the plug has the same PE connection system as the socket outlet or else use a suitable adapter.
The product must be connected to a main switch with a minimum contact gap of 3 mm in all poles.
Make sure that the product is suitable for the supply voltage and frequency available at the installation site.
The thermal switch cuts out the motor in case of overheating and cuts it in again automatically after cooling.
We recommend you to provide the permanent installation with an earth leakage circuit breaker (ELCB).
English (GB)
Fig. 1 Alarm device
Extension pipes between the toilet and lifting station must not be longer than 150 mm due to the increased risk of clogging.
TM04 9469 4310
3

4. Product introduction

English (GB)

4.1 Product description

The WC-1 and WC-3 are small, compact automatic lifting stations suitable for pumping domestic wastewater and sewage off places in private dwellings where wastewater cannot be led directly to the sewer by means of a natural downward slope.
If you are away for a long period (e.g. holidays) we recommend that you turn off the water supply to the toilet served by the unit.
This product is a domestic unit. Toilets connected to this unit can be used like any normal toilet, and require minimum maintenance. The unit will operate automatically as soon as the required level of water enters the tank.
Only the disposal of toilet paper, faecal matter and wastewater will be covered by warranty. Any damage due to foreign bodies such as cotton, condoms, sanitary towels, wet wipes, food, hair, metal, wood or plastic objects, will not be covered by warranty. Solvents, acids and other chemicals can also cause damage to the unit, and will invalidate the warranty.

4.2 Intented use

The product is only suitable for pumping wastewater from a cabinet shower, bidet and/or washbasin as well as sewage from a toilet.
Applications according to EN 12050-3. Not for public and heavy commercial or
industrial use, only a limited number of users.
Installation with direct connection to a toilet and in the same room as sanitary appliances.
A second toilet must be available above the backflow level.
The product must be fastened to the floor to prevent uplift and turning.

4.3 Pumped liquids

Domestic wastewater and sewage containing toilet paper and faeces.
Ordinary liquids for cleaning of the appliances connected. pH value: 4-10.
The product is designed for flush volumes of 4, 6 and 9 litres. A 4-litre flush is permissible only if the amount of solids in the pumped liquid is small.
The product must not pump harsh chemicals or solvents. See the quick guide.

5. Servicing the product

Always use original accessories from Grundfos to ensure safe and reliable operation.
WARNING
Electric shock
Death or serious personal injury
- Before starting any work on the product, make sure that the power supply has been switched off and that it cannot be accidentally switched on.
Maintenance and service must be carried out by specially trained persons and according to local regulations.
If the power supply cable is damaged, it must be replaced by the manufacturer, the manufacturer's service partner or similarly qualified person.
For service kits, see www.product­selection.grundfos.com.
The product must be thoroughly cleaned before it is returned for service. Otherwise, the warranty will be void.

5.1 Service documentation

Service documentation is available at www.product­selection.grundfos.com.
If you have any questions, please contact the nearest Grundfos company or service workshop.

5.2 Maintenance

The lifting station does not require any special maintenance, but we recommend that you check operation and pipe connections at least once a year.
Change the carbon filter once a year. See section 5.4 Service instructions.

5.3 Adjustment of run time

The default setting ensures proper operation in most pipes. If the pipes are particularly long or short, it may be necessary to adjust the run time.
For a guide to adjusting the run time, see www.product-selection.grundfos.com.
4

5.4 Service instructions

Thanks to the product design, service is easy in case of malfunction or a blocked pump.
Impeller or grinder stuck
1. Disconnect the power supply.
2. Unscrew the plug in the cover.
3. Insert a screwdriver (min. 110 mm) through the plug hole and into the slot of the shaft end. Turn the shaft right and left to free the impeller or grinder from dirt.
4. Fit the plug and switch on the power supply to check if the impeller or grinder can rotate freely.
Operation by means of a power drill
If the product cannot be operated by electrical power, disconnect the power supply and empty the toilet and tank by means of a power drill.
Pressure switch pipe blocked
The pressure switch unit can be removed separately.
1. If the water level in the tank is above the motor flange, disconnect the power supply and drain the tank by means of the drain hose (accessory).
2. Unscrew the cover.
3. Pull out the complete pressure switch.
4. Check and clean the pressure switch pipe. Make sure that the little tube in the top of the pipe has not become blocked while you have cleaned the pipe!
5. Lubricate the sealing area of the pressure switch for easier fitting.
Foreign body in the tank
CAUTION
Sharp element
Minor or moderate personal injury
- Beware of the sharp edges on the grinder. Wear protective gloves.
1. If the water level in the tank is above the motor flange, disconnect the power supply and drain the tank by means of the drain hose (accessory). See image 3.1 in the appendix.
2. Unscrew the cover.
3. Remove the four screws of the motor flange.
4. Lift the motor flange to reduce the compression of the O-ring. Insert a screwdriver into the notch underneath the power supply cable and press it down.
5. Lift out the complete motor-pump unit by the handles.
Lift the unit vertically before tilting it!
6. Check and clean the tank and impeller or grinder.
Carbon filter
Replace the carbon filter once a year to ensure sufficient filter function.
Instead of using a carbon filter, Sololift can also be vented through a venting pipe. In this case a venting valve is needed. Product number: 98059587.