Grundfos PF Series, PF 1-30, NS Series, NS 5-33, NS 4-23 Installation And Operating Instructions Manual

...
NS, PF
Installation and operating instructions
GRUNDFOS INSTRUCTIONS
NS, PF
Table of contents
English (GB)
Installation and operating instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Monterings- og driftsinstruktion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2
English (GB) Installation and operating instructions
Original installation and operating instructions
These installation and operating instructions describe Grundfos NS and PF.
Sections 1-3 give the information necessary to be able to unpack, install and start up the product in a safe way.
Sections 4-9 give important information about the product, as well as information on service, fault finding and disposal of the product.
CONTENTS
Page
1. General information

1.1 Target group

2. Installing the product
2. Installing the product
2.1 Pump location
2.2 Mechanical installation
2.3 Electrical connection
3. Starting up the product
3.1 Priming
4. Handling and storing the product
4.1 Handling the product
4.2 Storing the product
5. Product introduction
5.1 Product description
5.3 Applications
6. Maintaining the product
7. Fault finding
8. Technical data
8.1 Operating conditions
8.2 Mechanical data
8.3 Electrical data
9. Disposing of the product
Read this document before installing the product. Installation and operation must comply with local regulations and accepted codes of good practice.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Make sure that the system in which the pump is incorporated is designed for the maximum pump pressure.
This pump has been evaluated for use with water only.

1. General information

1.1 Target group
These installation and operating instructions are
3
intended for professional installers.
3 4

1.2 Hazard statements

4
The symbols and hazard statements below may
4
appear in Grundfos installation and operating
4
instructions, safety instructions and service
4
instructions.
6
7
7
7 7
7
7 8
8 9
10
10 11 12
The hazard statements are structured in the
12
following way:
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious personal injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious personal injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate personal injury.
SIGNAL WORD
Description of hazard
Consequence of ignoring the warning.
- Action to avoid the hazard.

English (GB)

3

1.3 Notes

English (GB)
The symbols and notes below may appear in Grundfos installation and operating instructions, safety instructions and service instructions.
Observe these instructions for explosion­proof products.
A blue or grey circle with a white graphical symbol indicates that an action must be taken.
A red or grey circle with a diagonal bar, possibly with a black graphical symbol, indicates that an action must not be taken or must be stopped.
If these instructions are not observed, it may result in malfunction or damage to the equipment.
Tips and advice that make the work easier.

2. Installing the product

Observe local regulations concerning limits for manual lifting or handling.
CAUTION
Crushing of feet
Minor or moderate personal injury
- Use safety shoes when handling the pump.

2.1 Pump location

Install the pump in a dry well-ventilated location. Protect the pump from rain, frost and direct sunlight. We recommend that you place the pump as close as
possible to the liquid to be pumped.

2.2 Mechanical installation

2.2.1 Foundation
Fasten the pump to a solid horizontal foundation by means of screws through the holes in the base plate.
NS pumps can be installed in horizontal or vertical position. If the pump is installed in vertical position, the motor must be above the pump.
PF pumps must only be installed in horizontal position.
2.2.2 Pipework
Make sure that the pump is not stressed by the pipework.
Fit rigid pipes with pipe hangers. Use sealing tape on the inlet and outlet ports of the
pump.
4

2.3 Electrical connection

DANGER
Electric shock
Death or serious personal injury
- Before starting any work on the product, make sure that the power supply has been switched off and that it cannot be accidentally switched on.
DANGER
Electric shock
Death or serious personal injury
- The protective earth of the socket outlet must be connected to the protective earth of the pump. The plug must therefore have the same PE connection system as that of the socket outlet. If not, use a suitable adapter.
We recommend that you fit the permanent installation with a residual-current circuit breaker, RCCB, with a tripping current less than 30 mA.
DANGER
Electric shock
Death or serious personal injury
- If the pump is used for cleaning or other maintenance of swimming pools, garden ponds or similar places, make sure that the pump is supplied through a residual-current circuit breaker, RCCB, with a tripping current of 30 mA.
DANGER
Electric shock
Death or serious personal injury
- Power supply cables without a plug must be connected to a supply disconnecting device incorporated in the fixed wiring according to the local wiring rules.
DANGER
Electric shock
Death or serious personal injury
- The pump must be earthed.
2.3.1 Wiring diagram
Red
Blue
Black
NL
Capacitor
Red
Blue
Black
Capacitor
White
Red
W2
W1
V2
U1
Blue
Blue
Capacitor
Brown
Ground
Motor protection
Motor
Line
White
Red
Motor
Blue
Blue
Power supply
Earth
Motor protection
Capacitor
Brown
Wiring diagram A
Fig. 1 Wiring diagram A for single-phase pumps
Wiring diagram B
English (GB)
TM06 4453 2315
Fig. 2 Wiring diagram B for single-phase pumps
TM06 4451 2315
5
Wiring diagram C
LINE 230 V - 220-277 V
W2
U2
V2
U1
V1
W1
White
Red
Blue
Red Blue White
3 230/400
3 ~ 220-277/380-480
MOTOR
LINE 400 V - 380-480 V
W2
U2
V2
U1
V1
W1
White
Red
Blue
Red Blue White
3 230/400
3 ~ 220-277/380-480
MOTOR
Blue Red White
Blue
Red
White
Blue Red White
Blue
Red
White
Three-phase
230/400
Three-phase
220-277 / 380-480
Motor
Three-phase
230/400
Three-phase
220-277 / 380-480
Motor
Voltage 230 V - 220-277 V
Voltage 400 V - 380-480 V
English (GB)
Fig. 3 Wiring diagram C for three-phase
Pump
PF 1-30
PF 2-50
NS 4-23
NS 5-33
NS 13-18
NS 3-40
NS 5-50
NS 5-60
NS 6-30
NS 6-40
NS 30-18
NS 30-18
NS 30-36
6
pumps
Voltage
[V]
220-240 A
220-240 B
3 x 400 CNS 30-30
Wiring
diagram

3. Starting up the product

WARNING
Flammable material
Death or serious personal injury
- Do not use the pump for flammable liquids, such as diesel oil, petrol or similar liquids.
DANGER
Electric shock
Death or serious personal injury
- Do not use the pump in swimming pools, garden ponds or similar places if there are people in the water.
CAUTION
Hot surface
Minor or moderate personal injury
- Do not run pump continuously with a closed inlet or outlet valve.
CAUTION
Hot or cold liquid
Minor or moderate personal injury
- Make sure that the escaping hot or cold liquid does not cause injury to persons or damage to the equipment.
WARNING
Corrosive substance
Death or serious personal injury
TM06 7750 3916
- Do not use the pump for aggressive liquids.
CAUTION
Hot surface
Minor or moderate personal injury
- Use protective gloves if the liquid or ambient temperature is higher than 40 °C.
CAUTION
Impurities in water
Minor or moderate personal injury
- Flush the system with clean water to remove all impurities before you start the pump.

3.1 Priming

1. Remove the priming plug. Use a flat-blade screwdriver if the priming plug is tight.
2. Fill the pump housing with water.
3. Fit the priming plug and screw it tight by hand only.
Always tighten plastic plugs by hand to avoid damage to the threads.
Fig. 4 Priming the NS pump
Fig. 5 Priming the PF pump

4. Handling and storing the product

4.1 Handling the product

Use lifting equipment when handling the product.
Do not drop or shake the product.

4.2 Storing the product

Store the product indoors in a dry and dust-free environment. Protect the product from vibrations.
Storage temperature: -10 to +40 °C.

5. Product introduction

5.1 Product description

Grundfos NS pumps are centrifugal pumps designed
TM06 7290 3716TM06 7291 3716
for lifting water in domestic, industrial and agricultural installations.
The pumps come in two versions:
• single-impeller pumps
• twin-impeller pumps. Grundfos PF pumps are compact peripheral
centrifugal pumps that can generate high heads.
English (GB)
7

5.2 Product identification

DK - 8850 Bjerringbro Denmark
Type: NS x-xx No: 99xxxxxx P5 17 08
U: 1x230 V~ I1/1: 7 A 60Hz P1: 1.5 kW
31.5 μF / 450 V~ Class:F IP:44 P2: 1.5 HP
Q: 2.4-9.6 m /h
3
H: 36-22.5 m Hmin: 22.5 m
n: 3400 min
-1
Serial nr.00001 Hmax: 38 m
pmax: 0.6/6 Mpa/bar TliqMax: 60°C TambMax: 55°C
Made in Italy by Grundfos
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17 18
19
English (GB)
5.2.1 Nameplate
1. Pump nameplate explanation
Pos. Description
1 Type designation
2 Supply voltage
3 Capacitor data
4 Nominal flow range
5 Speed
6 Maximum system pressure
7 Approval markings
8 Product number
9 Full load current an frequency
10 Motor insulation class and enclosure class
11 Nominal head
12 Serial number
13 Maximum liquid temperature
14 Production date [year/week]
15 Motor power input
16 Pump power output
17 Minimum head
18 Maximum head
19 Maximum ambient temperature

5.3 Applications

Application
Domestic applications Industrial applications Agricultural applications
Light industrial applications, such as feeding pressurised boilers (anticondensation)
Light gardening applications
TM06 8363 0816
Water supply
Draining and filling of cisterns
Grundfos NSGrundfos

6. Maintaining the product

In normal operation, the pump does not require any specific maintenance.
DANGER
Electric shock
Death or serious personal injury
- If the power supply cable is damaged, it must be replaced by the manufacturer, his service agent or similarly qualified persons in order to avoid hazard.
PF
8