Performance range, DME 3
Performance range, DMS 3
Digital Dosing 4
Type key 5
Codes 5
Functions
Overview of functions 6
Capacity range 7
Functions
Capacity control, DME 8
Capacity control, DMS 9
Control panel 10
Menu 12
Operating modes 13
Dosing monitoring 17
Control panel lock 18
Wiring diagram, DME 2 to 48 and DMS-A (AR) 19
Wiring diagram, DME (60 to 940) 20
Construction
Pump selection
DME 2 to 12 - standard range 33
DME 19 to 48 - standard range 34
DME 60 to 150 - standard range 35
DME 375 to 940 - standard range 36
DMS 2 to 4 - standard range 37
DMS 8 to 12 - standard range 38
Non-standard options 39
Pumped liquids
List of pumped liquids 40
Accessories
41
Sectional drawing, DME (2 to 48) 22
Material specification 22
Sectional drawing, DME (60 to 940) 23
Material specification 23
Sectional drawing, DMS 24
Material specification 24
Performance curves
DME, DMS, 60 Hz 25
Dimensions
Front-fitted control panel DME 2 to 48, DMS 28
Side-fitted control panel DME 2 to 48, DMS 28
DME (60 to 940) 29
Technical data
DME (2 to 48) 30
DME (60 to 940) 31
DMS 32
2
General data
Performance range, DME
p
p
[bar]
[psi]
18
240
16
DME 2-18
14
200
12
160
10
120
8
6
80
4
40
2
0
0
12.57.51218.548 60150376940
DME 8-10
1123 4 5 6 7 8 10102030 40 50 60 80100100200
DME 60-10DME 375-10
DME
DME
12-6 19-6
DME 48-3
DME
DME 150-4DME 940-4
Q [l/h]
Q [US GPH]
DME
TM02 9943 4604
Performance range, DMS
p
p
[bar]
[psi]
160
11
10
140
9
120
8
100
7
6
80
5
60
40
20
0
DMS 2-11
4
DMS 4-7
3
2
1
0
12345678910111213
0.51.01.52.02.53.0
DMS 8-5
DMS 12-3
DMS
Q [l/h]
Q [US GPH]
TM02 9944 4604
3
General data
DMS
DME and DMS
Digital Dosing
Digital Dosing represents state-of-the-art technology.
This patented Grundfos solution sets new standards,
including new principles and methods.
Precise and easy setting
The operator can easily install and set the pump to
discharge exactly the quantity of dosing liquid required
in the application. Capacity is read on the digital display
in GPH, l/h, or ml/h, while icons are used to identify the
operation mode.
Unique technology
A unique drive and microprocessor control ensure that
dosing liquids are discharged precisely and with low
pulsation even when the pump is operati ng with high
viscosity or degassing liquids. Instead of the conventional stroke length adjustment, the capacity of the
DME is regulated by automatic ajustment of the motor
speed during the discharge stroke and by fixed suction
stroke speed, ensuring optimal and uniform mixing. The
capacity of the DMS is regulated by automatic regulation of the stroke frequency.
Fewer variants to cover all needs
The powerful variable speed motor, a turn-down ratio of
1:1000/1:800 and a complete control interface including
• full pulse control,
• pulse batch control,
• internal timer batch control,
• analog 0/4-20 mA control,
• level control and
TM03 0815 0505
• fieldbus communication module
ensure that nine DME pumps cover the range from
0.00066 to 248.3 gallons per hour, up to 261 psi. The
switch mode power supply ensures that the same pump
is working precisely, irrespective of the power supply
(100-240 V; 50-60 Hz).
The DMS version with synchronous motor and a turndown ratio of 1:100 (consisting of four pump sizes and
two control versions) cover the range from 0.0066 to
3.17 GPH. The DMS-A pumps have external pulse,
analog 4-20 mA and level control interface; the DMS-B
version is without external control interface. The DMSD is without control and user interface.
The DME and DMS dosing pumps feature diaphragm
dosing head with integrated vent valve, suction and
discharge ball valves.
The pumps are also fitted with a power cable and plug.
4
General data
Type keyCodes
ExampleDME 2 - 18 - A - PP / E / C - F - 2 1 RR B
Type
range
Maximum capacity
[l/h]
Maximum pressure
[bar]
Control variant
Dosing head material
Gasket material
Valve ball material
Control panel position
Supply voltage
Valves
Connection suction/
discharge
Power plug type
ExampleA - PP / E / C - 2 - 1RRB
Control variant
A
AG A + Genibus
AR A + alarm relay
AP A + Profibus
BBasic
DOnly on/off
Dosing head material
PP Polypropylene
PV PVDF
SS Stainless steel
Gasket material
EEPDM
VFKM
Valve ball material
C Ceramic
SS 316 SS
GGlass
Y Hastelloy C
Control panel position
F Front-fitted
S Side-fitted
X No control panel
Supply voltage
1 1 x 230 V, 50 Hz
2 1 x 120 V, 60 Hz
3 1 x 100-240 V, 50-60 Hz
6 1 x 110 V, 50 Hz
8 1 x 100 V, 50/60 Hz
9 1 x 200 V, 50/60 Hz
Valves
1 Standard valve
2 Spring-loaded valve
Connection suction/discharge
Tubing 6/9 mm
1
Tubing 4/6 mm
supplied with the pump
Tubing 6/9 mm
2
Tubing 6/12 + 9/12 mm
supplied with the pump
3 Tubing 4/6 mm
4 Tubing 6/9 mm
5 Tubing 6/12 mm
6 Tubing 9/12 mm
T Tubing 0.17"/0.25"
R Tubing 0.25"/0.375"
S Tubing 0.375"/0.5"
A Threaded Rp 1/4
B Threaded Rp 3/8
V Threaded NPT 1/4"
Y Threaded NPT 3/8"
E Cementing d.10 mm
F Cementing d.12 mm
Q Tubing 19/27 + 25/34
W Tubing 32/41 + 38/48
A1 Threaded Rp 3/4"
A2 Threaded Rp 1 1/4"
A3 Threaded NPT 3/4”
A4 Threaded NPT 1 1/4”
Power plug
F EU (Schuko)
B USA, Canada (120 V)
GUK
IAustralia
E Switzerland
J Japan
DME and DMS
5
Functions
Overview of functions
2 to 4860 to 940 AR60 to 940 Bvariant Avariant Bvariant D
DME and DMS
DMEDMS
TM01 8941 0900
Capacity control, see page 8
Internal stroke frequency
control
Internal stroke speed controlzzz
Control panel, see page 10
Capacity setting in liters,
milliliters or US gallons
Display with background light
and soft-touch buttons
Easy set-up menu with
language options
On/off buttonzzzzz
Maximum capacity button
(priming)
Green indicator light for
operating indication
Red indicator light for
fault indication
Control panel lock zzzzz
Side-fitted as an optionzzzz
Operating modes, see page 13
Manual controlzzzzz
Pulse controlzzz
Analog 0/4-20 mA controlzzz
Timer-based batch controlzz
Pulse-based batch controlzz
Functions, see page 17
Dosing monitoringzzz
Dual-level controlzzz
Calibration of pump to actual
installation
Anti-cavitation
(reduced suction speed)
Capacity limitationzzz
Counters for strokes, operating
hours and power on/off
Fieldbus communication
(variants AP and AG)
Overload protectionzz
Error message in displayzz
Leakage sensorz
Dosing signal outputz
Power supply, page 16
Switch-mode power supplyzzz
Inputs/outputs, see page 19
Input for pulse controlzzz
Input for analog 0/4-20 mA
control
Input for dual-level control zzz
Input for external start/stopzzz
Alarm relay output (variant AR)zzz
Dosing outputz
Input for external on/off switchzzz
zzzzz
zzzzz
zzzzz
zzzzz
zzzzz
zzzzz
zzzzz
zzzzz
zzz
zzzzz
zz
zzz
TM02 8337 4903
TM02 8338 4903
TM01 8941 0900
TM01 8943 0900
TM02 8973 1304
6
Functions
Capacity range
p
p
[bar]
[psi]
18
240
16
DME 2-18
14
200
12
160
10
120
80
40
8
DMS 2-11
6
4
2
0
0
12.547.5121218.548 60150376940
DMS, DME
DME 8-10
DME 60-10DME 375-10
DME
DMS
8-5
DME
12-6 19-6
DMS
12-3
DME 150-4DME 940-4
DME 48-3
DMS
4-7
11234 5 6 7 8 10102030 40 50 60 80 100100200
DME and DMS
Q [l/h]
Q [US GPH]
The maximum capacity is available at any counter pressure withi n the pump's
specified range if it has been calibrated to the actu al installation.
TM02 9945 4604
7
Functions
Capacity control, DME
DME
The electronically controlled variable-speed motor of
the DME pumps provides optimum control of the stroke
speed. As shown in the figure below, the duration of
each suction stroke is constant while the duration of
each discharge stroke varies according to the capacity
set, resulting in optimum discharge flow in any operating situation.
The advantages are as follows:
• The pump is always operating at full stroke length,
irrespective of the capacity set, for optimum accuracy, priming and suction.
• A capacity range of 1:1000 (DME 2 to 48) for each
pump size.
Capacity
setting
100%
50%
10%
Discharge
Suction
Discharge
Suction
Discharge
Suction
• A capacity range of 1:800 (DME 60 to 940) for each
pump size.
• Even and constant dosing ensuring an optimum
mixing ratio at the injection point.
• Significant reduction of pressure surges, preventing
mechanical stress on diaphragm, tubes, connections and other dosing parts exposed to leakage
and wear.
• The installation is less affected by long suction and
discharge lines.
• Easier dosing of highly viscous and gas-containing
liquids.
The optimum dosing control shown below takes place
in any operating mode.
duration
duration
duration
TM01 8944 0900
8
Functions
Capacity control, DMS
DMS
The electronically controlled synchronous motor of the
DMS offers similar advantages of the DME pumps. As
shown in the figure below, the suction and discharge
stroke speeds are constant while the stroke frequen cy
varies according to the capacity set.
The sinusoidal movement of the diaphragm offers the
following advantages:
• The pump is always operating at full stroke length,
irrespective of the capacity set, for optimum accuracy, priming and suction.
Capacity
setting
100%
50%
10%
Discharge
Suction
Discharge
Suction
Discharge
Suction
• A capacity range of 1:100 for each pump size.
• Reduction of pressure surges, preventing mechanical stress on diaphragm, tubes, connections and
other dosing parts exposed to leakage and wear.
• The installation is less affected by long suction and
discharge lines.
• Easier dosing of highly viscous and gas-containing
liquids.
duration
duration
duration
TM01 8945 0900
9
Functions
DME and DMS
Control panel
LCD Display
Menu/
accept
Navigation/
settings
100%
Priming button
Control panel fitted to the front.
ml/h
Navigation/
settings
settings
Green
indicator light
Red
indicator light
On/off button
Indicator lights and alarm output
(DME 2 to 48, DMS)
The green and red indicator lights on the pump indicate
operation or fault.
In control variant AR, the pump can activate an external
alarm signal by means of a built-in alarm relay. The
alarm signal is activated by means of an internal potential-free contact.
The functions of the indicator lights and the built-in
alarm relay appear from the table below.
Condition
TM01 8946 1202TM01 8941 0900TM01 8949 0900
Pump runningOnOff
Pump pausedFlashingOff
Pump faultOffOnEEPROM
Supply failureOffOffOff
Pump running, low
chemical level
2
Green
Red LED Display
LED
OnOn
Normal
indication
Normal
indication
Normal
indication
Alarm
output
132
NC NO C
132
NC NO C
23
1
NC NO C
132
NC NO C
23
1
NC NO C
1
Control panel fitted to the side (not DMS-B).
Priming button
The pump control panel incorporates a button.
Press this button if the maximum capacity is required
over a short period, e.g. during start-up. When the
button is released, the pump automatically returns to
the previous operating mode.
When the buttons and are pressed simultane-
100%
ously, the pump can be set to run for a specific number
of seconds at maximum capacity. The remaining
numbers of seconds will appear in the display. This
feature is useful when flushing the pump. The
maximum value is 300 seconds.
Press to stop the pump before the set time has
passed.
100%
Empty tank
Analog signal
< 2 mA
The pump is not dosing
enough according to the
signal from the dosing
monitor
More pulses than capacityOnOn
OverheatedOffOn
1
Control variant AR, only.
2
Requires connection to level sensors.
3
Requires dosing monitor function activated and a dosing
monitor device connected to the pump.
2
3
OffOn
OffOn
OnOn
indication
indication
indication
indication
Normal
Normal
Normal
Normal
MAX
TEMP
23
1
NC NO C
23
1
NC NO C
23
1
NC NO C
23
1
NC NO C
23
1
NC NO C
10
Functions
DME and DMS
Indicator lights and alarm output (60 to 940)
ConditionGreen LED Red LED Display
Pump runningOnOff
Set to stopFlashingOff
Normal
indication
Normal
indication
Pump faultOffOnEEPROM
Supply failureOffOffOff
Pump running, low
chemical level
Empty tank
2
2
OnOnLOW
OffOnEMPTY
Alarm
output1
132
NC NO C
132
NC NO C
1
NC NO C
132
NC NO C
1
NC NO C
1
NC NO C
23
23
23
ConditionGreen LED Red LED Display
1
Control variant AR, only.
2
Requires connection to level sensors.
3
Requires activation of the dosing monitoring function and connection
to a dosing monitor.
4
Please contact a Grundfos service centre.
5
Alarms can be reset after fault conditions are back to normal.
6
The pump will make 10 attempts to restart before going into
permanent off mode.
output1
Alarm
Analog signal < 2 mAOffOnNO mA
The dosed quantity is
too small according to
the signal from the
dosing monitor
3
OnOn
OverheatingOffOn
Internal
communication failure
Internal Hall Failure
Diaphragm failure
(leakage)
Max. pressure
exceeded
More pulses than
capacity
5
5
OffOn
4
OffOnHALL
OffOnLEAKAGE
6
Off
On
OnOn
NO
FLOW
MAX
TEMP
INT
COM
OVER-
LOAD
MAX
FLOW
23
1
NC NO C
23
1
NC NO C
23
1
NC NO C
23
1
NC NO C
23
1
NC NO C
23
1
NC NO C
23
1
NC NO C
23
1
NC NO C
No detection of
motor rotation
4
OnOnORIGO
23
1
NC NO C
11
Functions
Menu
The DME and DMS dosing pumps feature a userfriendly menu which is activated by pressing the
button. During start-up, all texts will appear in the
English language, but other languages can be selected
(see page 16).
The example shown below applies only to DME 60 to
940 pumps.
DME and DMS
mA
D68se
12
Functions
DME and DMS
Operating modes
Manual control
The pump is dosing constantly according to the quantity
set in l/h or ml/h by means of the buttons and .
It automatically changes over between the measuring
units.
Setting range, DME:
DME
2-180.00066-
8-100.002-
12-60.0032-
19-60.0049-
48-30.0127-
60-100.0198-15.8575-60
150-40.0495-39.63187.5-150
375-100.1238-99.06468.75-375
940-40.3104-248.321175-940
The figures in brackets indicate the maximum
GPHtoGPHml/htol/h
capacity when the anti-cavitation function is activated.
See page 15 for adjusted DME 60 to 940 capacities.
The pump is dosing according to an external analog
signal. The dosed capacity is proportional to the input
value in mA.
4-20 (default):4 mA = 0%
20 mA = 100%
20-4:4 mA = 100%
20 mA = 0%
0-20:0 mA = 0%
20 mA = 100%
20-0:0 mA = 100%
20 mA = 0%.
The maximum capacity limitation, see page 15, will
influence the capacity. 100% (20 mA) corresponds to
the maximum capacity or the set capacity limitation.
Pulse control
Applies to DME and DMS-A.
The pump is dosing according to an external pulse
signal, e.g. from a water meter.
There is no direct relation between pulses and dosing
strokes. The pump automatically calculates its optimal
speed to ensure the required quantity is dosed for each
pulse. The quantity to be dosed is set in ml/pulse. The
pump adjusts its speed and/or stroke frequency
according to two factors:
• frequency of external pulses and
• the set quantity per pulse.
100
80
60
40
4-20 mA signal
20
Maximum capacity [%]
0
048121620
Input signal [mA]
4-20 mA signal
TM01 8218 0100
13
Functions
DME and DMS
Timer-based batch control
Applies to DME
The pump is dosing the set quantity in batches at
maximum capacity or the set capacity limitation.
The time until the first dosing (NX) and the following
sequences (IN) can be set in minutes, hours and days.
The maximum time limit is 9 days, 23 hours and 59
minutes (9:23:59).
The lowest acceptable value is one minute. IN must be
higher than the time required to perform one batch. If IN
is lower than the time required, the next batch will be
ignored. In case of supply failure, the set dosing quantity, the IN time and the remaining NX time are stored.
When the supply is reconnected, the pump will start up
with the NX time at the time of the supply failure. This
way the timer cycle will continue, but it will be delayed
according to the time of the supply failure. This feature
is not available on variant "B" pumps.
Quantity pr. batch
Setting range (applies to DME only)
Timer-based and pulse-based batch control
DME 2:
DME 8:
DME 12:
DME 19:
DME 48:
DME 60:
DME 150:
DME 375:
DME 940:
0.23 ml/batchto5 l/batch
0.00006 G/batchto1.32 G/batch
0.69 ml/batchto15 l/batch
0.00018 G/batchto3.96 G/batch
1.11 ml/batchto24 l/batch
0.00029 G/batchto6.34 G/batch
2.04 ml/batchto37 l/batch
0.00053 G/batchto9.77 G/batch
5.3 ml/batch to96 l/batch
0.0014 G/batchto25.4 G/batch
6.25 ml/batch to120 l/batch
0.0017 G/batch to31.7 G/batch
15.6 ml/batch to300 l/batch
0.0041 G/batchto79.3 G/batch
39.1 ml/batchto750 l/batch
0.01 G/batchto198.1 G/batch
97.9 ml/batch to1880 l/batch.
0.025 G/batchto496.7 G/batch
Quantity pr. batch
:
NX
IN
Pulse-based batch control
Applies to DME
The pump is dosing the set quantity in batches at
maximum capacity or the set capacity limitation. The
quantity is dosed every time the pump receives an
external pulse. If the pump receives new pulses before
the batch is completed, these pulses will be ignored.
However the manually control DME B cannot be
controlled externally.
t
TM01 8942 0900
Pulse
Pulse
TM01 8947 0900
Anti-cavitation (2 to 48)
Applies to DME
When this function is selected, the pump extends and
smooths its suction stroke, resulting in softer priming.
The anti-cavitation function is used:
• when pumping liquids of high viscosity
• when pumping degassing liquids
• in the case of a long suction tube and
• in the case of a high suction lift.
The maximum capacity is reduced when this function is
selected, see table below.
The pump features an anti-cavitation function. When
this function is selected, the pump extends and
smoothes its suction stroke, resulting in softer priming.
The anti-cavitation function is used:
• when pumping liquids of high viscosity,
• in the case of a long suction tube and
• in the case of a high suction lift.
Depending on the circumstances, during the suction
stroke, the motor speed can be reduced by 75%, 50%
or 25% compared to the normal motor speed during the
suction stroke.
The maximum pump capacity is reduced when the anticavitation function is selected
This function offers the possibility of reducing the
maximum capacity (MAX. CAP). It influences the functions in which the pump is normally operating at
maximum capacity. Under normal operating conditions,
the pump cannot operate at a capacity higher than the
one stated in the display. This does not apply to the
priming button.
By means of this function, a large pump can be set to
act as a much smaller pump. Together with the 1:1000/
1:800 capacity range, the purposes of this function are:
DME and DMS
1
2
Small pumpLarge pump
2
3. To cover several needs with just one pump size.
4. To adapt the pump to a 4-20 mA signal control with
4 mA corresponding to 0% and 20 mA to the set
maximum capacity.
In this way it is possible for instance to use a DME 48
for dosing a very small quantity of liquid without
changing the input signal. See example below.
Example:
A DME 48 receives a 12 mA input signal from a control
instrument, resulting in a 50% output (according to the
analog curve on page 13) and a capacity of 24 l/h. A
new situation occurs where it is only necessary to dose
2 l/h. The maximum capacity limitation is set to 4 l/h.
The pump is still receiving a 12 mA signal resulting in a
50% output and a capacity of 2 l/h.
Q
Q
[l/h]
[US GPH]
48
12
44
11
40
10
36
9
32
8
28
7
24
6
20
5
16
4
12
3
8
2
4
1
0
0
048121620
1
n
o
i
t
a
t
i
m
i
l
.
p
a
c
o
N
h
/
l
4
=
.
t
i
m
i
l
.
p
a
C
[mA]
TM02 0158 3301TM02 9942 4604
1. To utilize the smooth and even dosing characteristics of the pump at low capacities to achieve
– improved chemical mixing,
– improved dosing through long discharge tubes and
– improved dosing of high-viscous liquids.
2. To improve the dosing of gas-containing liquids: In a
large pump, as compared to a small pump, the displaced volume (1) is much larger than the non-displaced volume (2).
The maximum capacity limitation will also reduce the
pump speed in timer-based batch control, pulse-based
batch control and during calibrati on where the pump is
usually operating at maximum capacity.
Calibration
After start-up, the dosing pumps can be calibrated to
the actual installation to ensure that the displayed value
(milliliters or liters) is correct. A calibration program in
the main menu facilitates this process.
15
Functions
Counters
The pump can display "non-resettable" counters for:
• "Quantity"
Accumulated dosed quantity in liters or US gallons.
• "Strokes"
Accumulated number of dosing strokes.
• "Hours"
Accumulated number of operating hours (power on).
• "Power ON"
Accumulated number of times the mains supply has
been switched on.
Languages
The display text can be displayed in one of the following
languages chosen in the set-up menu:
• English
•German
•French
•Italian
• Spanish
• Portuguese
•Dutch
• Swedish
• Finnish
•Danish
• Czech
•Slovak
• Polish
• Russian.
Integrated venting
The DME and DMS dosing pumps are provided with an
integrated vent valve. The valve makes it very easy to
prime the pump during start-up:
The vent valve must be connected to the tank by means
of 1/4" tubing.
DME and DMS
DME 60 to 940
Vent valve
Switch-mode power supply
Applies to DME
The DME pump is incorporates a switch-mode power
supply. This makes the pump independent of variations
in supply voltage and frequency. Operating range: 1 x
100-240 V, 50-60 Hz.
Level control
Applies to DME-A and DMS-A
The pump can be connected to a level control unit for
monitoring of the chemical level in the tank.
The pump can react to two level signals. The following
table shows the pump reactions to the sensor signals:
Level sensorsPump reaction
Upper sensor activated
Lower sensor activated
Applies to control variant AR
• Red indicator light is on.
• Pump running.
• Alarm relay activated.
• Red indicator light is on.
• Pump stopped.
• Alarm relay activated.
Bus communication
Applies to DME
The pump is available with an opti onal built-in module
for bus communication with GENIbus (variant AG, DME
2 to 48 only) or PROFIBUS (variant AP) systems.
These modules enable remote monitoring and setting
via the fieldbus system. All DME features are available
via bus communication. The PROFIBUS GDS-file can
be downloaded from www.grundfos.com/dosing.
TM02 7066 2503
For the larger pumps, the vent valve must be connected
to the tank by means of 5/8" ID tubing.
16
Vent valve
TM01 8420 5099
Diaphragm leakage sensor (DME 60 to 940)
The pump can be fitted with a leak sensor that connects
to the drain hole of the pump head. In the event of
diaphragm leakage, the sensor will activate the pump's
alarm relay.
Functions
Dosing monitoring
Applies to all DME 2 to 48 and DMS AR
Dosing stoke measured
DME and DMS
Dosing stoke measured
Dosing stoke measured
Monitor mounted on suction side
(DME and DMS)
Monitor mounted on discharge side
(DMS only)
The dosing monitor is designed to monitor the dosing of
liquids which may cause gas accumulation in the pump
head, thus stopping the dosing process even if the
pump is still operating.
For every measured dosing stroke, the dosing monitor
gives a pulse signal to the level input so that the pump
can compare performed pump strokes (from internal
stroke sensor) with externally measured physical
strokes (from the dosing monitor). If an external dosing
stroke is not measured together with the internal dosing
stroke, this is considered a fault that may have been
provoked by an empty tank or gas in the dosing head.
When used together with a DME pump, the monitor will
only operate if it is mounted on the suction side of the
pump.
When used together with a DMS (A, AR) pump, the
monitor will also operate if it is mounted on the
discharge side of the pump.
The dosing monitor should be connected to the level
input (pins 2 and 3). This input must be configured to
dosing monitoringin the pump's setup menu. Consequently, it cannot be used as level input.
Once the input has been set for dosing monitoring and
a dosing monitor has been connected and set, the
dosing monitoring function will be active.
Monitor mounted in dosing tube.
In discharge tube: DMS (in-line)
In suction tube: DME and DMS (in-line)
• Incorrect dosing stroke: There is no pulse from the
dosing monitor corresponding to the internal stroke
signal within the acceptable time (the pump is not
pumping).
Logic:
If two incorrect dosing strokes are performed, the pump
will continue operating, but it will change over to alarm
mode, like in case of "low level". The red indicator light
will be on and the alarm output, if any, will be activated
(variant AR).
For each correct stroke the counter is reset and the
alarm output, if any, is deactivated.
Operation in connection with vent valve:
TM02 2029 3201 - TM02 2030 3201 - TM02 2031 3201
Definitions:
• Correct dosing stroke: A pulse from the dosing monitor corresponds to the internal stroke signal within
acceptable time.
TM02 2048 4802
17
Functions
DME and DMS
It is possible to add a self-acting solution for liquids that
cause gas accumulation by using an automatic vent
valve. The solution is the dosing monitor with a pump
and an alarm output (control variant AR). The alarm
output thus activates the vent valve, which will automatically vent gas accumulated in the dosing head. When
the dosing head has been vented, the pump will start
pumping again, the alarm output will be deactivated
and the vent valve will close.
Control panel lock
It is possible to lock the buttons on the control p anel to
prevent maloperation of the pump. The locking function
can be set to "ON" or "OFF". The default setting is
"OFF".
A PIN code must be entered to change from "OFF" to
"ON". When "ON" is selected for the first time, "_ _ _ _"
will appear in the display. If a code has already been
entered, it will appear when an attempt to change to
"ON" is made. This code can either be re-entered or
changed.
Units
It is possible to select metric units (liter/milliter) and US
units (gallons).
Metric measuring units:
• In manual and analog modes, set th e quanti ty to be
dosed in liters per hour (l/h) or milliliters per
hour (ml/h).
• In pulse mode, set the quantity to be dosed in ml/
pulse. The actual capacity is indicated in liters per
hour (l/h) or milliliters per hour (ml/h).
• For calibration, set the quantity to be dosed in ml
per 100 strokes.
• In timer and batch modes, set the quantity to be
dosed in liters (l) or milliliters (ml).
• Under the "QUANTITY" menu item in the
"COUNTERS" menu, the dosed quantity is indicated
in liters.
US measuring units:
• In manual and analog modes, set the quantity to be
dosed in gallons per hour (gph).
• In pulse mode, set the quantity to be dosed in ml/
pulse. The actual capacity is shown in gallons per
hour (gph).
• For calibration, set the quantity to be dosed in ml
per 100 strokes.
• In timer and batch modes, set the quantity to be
• dosed in gallons.
• Under the "QUANTITY" menu item in the
"COUNTERS" menu, the dosed quantity is indicated
in gallons (gal).
The drawing below shows all possible settings.
18
3 x
Operating display
Operating display
Functions
Wiring diagram, DME 2 to 48 and DMS-A (AR)
See pages 30 and 32 for input/output data.
"NO" black
"NC" blue
"COM" brown
DME and DMS
5
4
Control cable
Product no.:
2 m cable: 96440447
5 m cable: 96440448
3
4
5
The level switch contacts (normally open) must be closed at low level/empty tank.
1
3
4
2
1
1
2
3
Level cable
Product no.:
2 m cable: 96440450
5 m cable: 96440451
2
3
1
4
Low level
Empty tank
Control input
Number/color
Function
Manual22
Pulse11
Pulse + external on/off11 + 22
Analog–+mA signal
Analog + external on/off22–+mA signal
Timer + external on/off22
Batch11
1 = Contact for pulse signal / 2 = Contact for external on/off
Pumps in analog mode cannot be connected in series.
1/brown2/white3/bl ue4/black5/grey
Plug
Description
Level input
Number/color
Function
1/brown2/white3/blue4/black
Low level Low level
Empty tankEm pty tank
Low level Em pty tankLow level + empty tank
Dosing monitoringDosing monitoring
Plug
TM01 8422 5001
19
Functions
Wiring diagram, DME (60 to 940)
DME and DMS
3
1
Analog/Pulse/Leakage cable
Product no.:
2 m cable: 96440447
5 m cable: 96440448
2
3
5
1
4
4
5
2
Relay cable
Product no.:
2 m cable: 96534214
5 m cable: 96534215
2
3
5
1
4
2
1
3
2
1
3
3
1
Stop dosing cable
Product no.:
2 m cable: 96527109
5 m cable: 96527111
2
3
1
4
4
2
5
1
2
3
Level cable
Product no.:
2 m cable: 96440450
5 m cable: 96440451
TM0 27069 2503
Cable 1: Analog, pulse and leakage input
Number/color1/brown2/white3/blue4/black5/grey
Function
Analog input 4-20 mA(-) 4-20 mA input(+) 4-20 mA input
Low level input5 VGnd
The function for the potential-free contact sets can be chosen from the display (NO = Normally Open and NC = Normally Closed).
21
Construction
Sectional drawing, DME (2 to 48)
DME
116
15
14
13
2
18
4
5
6
3
7
8
10 11 12
9
26
20 1921
22
Construction
The DME pump is a motor-driven diaphragm dosing
pump consisting of the following main parts:
Dosing head: Designed with a minimum of clearance
space to optimise the priming and deaerating capabili ties. The dosing head has built-in valve housings.
Valves: Double-ball suction valve and single-ball
discharge valve. Spring-loaded valves are available as
an option.
Vent valve: For priming and deaeration complete with
connection for a 1/4” tubing.
Connections: Sturdy and easy-to-use connections for
various sizes of tubing, pipe thread or pipe cementing.
Diaphragm: PTFE-coated, textile-reinforced EPDM
diaphragm designed for long life.
Backplate: With separation chamber, safety diaphragm
and drain hole.
Drive unit: With diaphragm connecting rod, crank, beltdrive and stepper motor, all mounted on a sturdy frame.
Cabinet: Containing drive unit, electronics, control
panel and various electrical connections.
The pump can be supplied with spring-loaded valves.
Spring material: Hastelloy.
The spring is not shown in the sectional drawing.
Spring material: Hastelloy.
The spring is not shown in the sectional drawing.
23
Construction
Sectional drawing, DMS
DME
116
15
14
13
2
18
4
5
3
6
7
8
10 11 12
9
2621
20 19 22
Construction
The DMS pump is a motor-driven diaphragm dosing
pump consisting of the following main parts:
Dosing head: Designed with a minimum of clearance
space to optimise the priming and deaerating capability. The dosing head has built-in valve housin gs.
Valves: Double-ball suction valve and single-ball
discharge valve. Spring-loaded valves are available as
an option.
Vent valve: For priming and deaeration complete with
connection for a 1/4” tubing.
Connections: Sturdy and easy-to-use connections for
various sizes of tubing, pipe thread or pipe cementing.
Diaphragm: PTFE-coated, textile-reinforced EPDM
diaphragm designed for long life.
Backplate: With separation chamber, safety diaphragm
and drain hole.
Drive unit: With diaphragm connecting rod, crank, beltdrive and synchronous motor, all mounted on a sturdy
frame.
Cabinet: Containing drive unit, electronics, control
panel and various electrical connections (DMS-A).
The pump is available with spring-loaded valves.
Spring material: Hastelloy.
The spring is not shown in the sectional drawing.
A 6.93(176)6.93(176)9.37( 238)9.37(238)
B 7.8(198)7.8(198)8.58(218)8.58(218)
C 13.03(331)13.58(345)18.54(471)19.53(496
D 11.18(284)11.18(284)14.33( 364)14.33(364)
E 7.09(180)7.09(180)9.06(230)9.06(230)
F 17.48(444)17.48(444)21.26(540)21.22(539)
G 1.61(41)1.10(28)1.22(31)0.24(6)
H 2.91(74)2.91(74)3.74(95)3.74(95)
I 7.36(187)7.36(187)9.69(246)9.69(246)
B
F
G
E
DME 60DME 150DME 375DME 940
H
I
TM03 0589 0305
29
Technical data
DME (2 to 48)
PumpDME 2DME 8DME 12 DME 19 DME 48
Maximum capacity without anti-cavitation
Maximum capacity with anti-cavitation
Maximum pressure
2
Maximum stroke frequency
Mechanical data
Weight and size
Electrical data
Signal input
Signal
output
Sound pressureThe sound pressure level of the pump is low er th an 70 db ( A) .
ApprovalsCE, VDE, cUL, UL, METI
1
At any back-pressure within the pump’s specified range when calibrated to the actual installation.
2
The maximum stroke frequency varies according to calibration.
3
Maximum suction lift: 3 ft.
Maximum wet/primed suction lift [ft (m)]19.7 (6)
Maximum suction lift when priming with wet valves [m]5.9 (1.8) 9.8 (3)9.8 (3)9.8 (3)9.8 (3)
Maximum viscosity with spring-loaded valves
Maximum viscosity without spring-loaded valves
Maximum liquid temperature [F (°C)]122 (50)
Minimum liquid temperature [F (°C)]32 (0)
Maximum ambient temperature[F (°C)]113 (45)
Minimum ambient temperature[F (°C)]32 (0)
Accuracy of repeatability±1%
Weight [lb (kg)]5 (2.3)5 (2.3)5 (2.3)7.5 (3.4) 7.5 (3.4)
Diaphragm diameter [in (mm)]1.1 (28 ) 1.5 (38) 1.7 ( 4 3 .5 ) 2 . 2 ( 5 5 ) 3.03 (77)
Supply voltage [V]1 x 100-240 V, 50-60 Hz
Maximum current consumption [A]
Maximum power consumption P
Enclosure classIP 65
Insulation classF
Voltage in level sensor input [VDC]5
Voltage in pulse input [VDC]5
Minimum pulse-repetition period [ms]3.3
Impedance in analog 0/4-20 mA input [Ω]250
Maximum loop resistance in pulse signal circuit [Ω]350
Maximum loop resistance in level signal circuit [Ω]350
Maximum load of alarm relay output, at ohmic load [A]2
Maximum voltage, alarm relay output [V]250
Maximum capacity
Minimum capacity
Maximum capacity with anti-cavitation 75% [l/h]
Maximum capacity with anti-cavitation 50% [l/h]
Maximum capacity with anti-cavitation 25% [l/h]
Maximum pressure [psi (bar)]145, (10)58, (4)145, (10)58, (4)
Maximum stroke frequency [stroke/min]160
Mechanical data
Weight and size
Electrical data
Cable dataPower supply cable [ft, (m)]4.9, (1.5)
Signal input
Signal
output
ApprovalsCE, CB, VDE, PSE, CSA
Sound pressure
level
1
Maximum suction lift: 3ft.
Maximum wet/primed suction lift [ft (m)]19.7 (6)
Maximum suction lift when priming with wet valves [ft (m)]4.9 (1.5)
Maximum viscosity with spring-loaded valves
Maximum viscosity without spring-loaded valves
Maximum liquid temperature [F, °C]122 (50)
Minimum liquid temperature [F, °C]32 (0)
Maximum ambient temperature [F, °C]113 (45)
Minimum ambient temperature [F, °C]14 (-10)
Accuracy of repeatability±1%
Weight [lbs, (kg)]25.1, (11.4) 26, (11.8) 46.3, (21) 49.6, (22.5)
Diaphragm diameter [in, (mm)]3.1, (79)4.2, (106) 4.9, (124)6.8, (173)
Supply voltage [V]1 x 100-240 V, 50-60 Hz
Maximum current consumption [A]
Maximum power consumption P
Enclosure classIP 65
Insulation classB
Voltage in level se nsor input [VDC]5
Voltage in pulse input [VDC]5
Minimum pulse-repetition period [ms]3.3
Impedance in analog 0/4-20 mA input [Ω]250
Maximum loop resistance in pulse signal circuit [Ω]350
Maximum loop resistance in level signal circuit [Ω]350
Maximum load of alarm relay output, at ohmic load [A]2
Maximum voltage, alarm relay output [V]
The sound pressure level of the pump is lower than 70 dB (A).
1
[W]
1
[cps]
1
[cps]
[GPH (l/h)]
[GPH
(ml/h)]
[GPH (l/h)]
[GPH (l/h)]
[GPH (l/h)]
at 100 V1.252.40
at 230 V0.671.0
15.9, (60) 39.6, (150) 99.1, (375) 248.3, (940)
0.0198
(75)
11.9, (45) 29.6, (112) 74.2, (281) 186.2, (705)
7.9, (30)19.8, (75) 49.7, (188) 124.2, (470)
4.0, (15)10.0 (38) 24.8, (94) 62.1, (235)
0.0495
(187,5)
3000 cps at 50% capacity
67.1240
200
42
0.1238
(468.75)
DME
0.3104
(1175)
31
Technical data
DMS
PumpDMS 2DMS 4DM S 8D MS 12
DMS-A
and AR, B
Maximum capacity
Maximum pressure
Mechanical data
Weight and size
Electrical data
Signal input
Signal output
Sound pressureThe sound pressure level of the pump is low er th an 70 db ( A) .
ApprovalsCE, VDE cUL, UL, METI
1 At any back-pressure within the pump’s specified range when calibrated to the actual installation.
2
The maximum stroke frequency varies according to calibration.
3
Maximum suction lift: 3 ft.
4
DMS-D: only CE and VDE.
Maximum stroke frequency
Maximum wet/primed suction lift [ft, (m)]19.7 (6)
Maximum suction lift when priming with wet valves [ft, (m)]5.9 (1.8)6.6 (2)9.8 (3)9.8 (3)
Maximum viscosity with spring-loaded valves
Maximum viscosity without spring-loaded valves
Maximum liquid temperature [F, °C]122 (50)
Minimum liquid temperature [F, °C]32 (0)
Maximum ambient temperature [F, °C]113 (45)
Minimum ambient temperature [F, °C]32 (0)
Accuracy of repeatability±1%
Weight [lbs, (kg)]5, (2.3)
Diaphragm diameter [in, (mm)]1.1 (28)1.3 (32)1.5 (38)1.8 (42.5)
Supply voltage
Maximum current consumption [A]
Maximum power consumption P
Enclosure classIP 65
Insulation classF
Voltage in level sensor input [VDC]5
Voltage in pulse input [VDC]5
Minimum pulse-repetition period [ms]3.3
Impedance in 0/4-20 mA analog input [Ω]250
Maximum loop resistance in pulse signal circuit [Ω]350
Maximum loop resistance in level signal circuit [Ω]350
Maximum load of alarm relay output at ohmic load [A]2
Maximum voltage, alarm relay output [V]250
1
2
[stroke/min]
[W]
1
DMS-D
(50 Hz)
DMS-D
(60 Hz)
DMS-A and AR, B180
DMS-D (50 Hz)
DMS-D (60 Hz)
3
[mPas] (= cP)
3
[mPas] (= cP)
[l/h]2.547.512
[gph]0.661.051.983.17
[l/h]3.3 ± 20%5.7 ±18% 8.7 ± 8% 13.7 ± 6%
[GPH]0.87 ± 20% 1.5 ±18% 2.3 ± 8%3.6 ± 6%
[l/h]3.9 ± 20%6.9 ±18% 10.4 ± 8% 16.4 ± 6%
[GPH]1.03 ± 20% 1.82 ±18% 2.75 ± 8% 4.33 ± 6%
[bar]1175.43.4
[psi]1601027849
187.5
225
500
200
1 x 230 V –13%/+10%, 50/60 Hz
1 x 120 V –12%/+8%, 60 Hz
1 x 100 V ±6%, 50/60 Hz
at 100 V0.2
at 120 V0.17
at 230 V0.09
20
DMS
4
32
Pump selection
DME 2 to 12 - standard range
DME, 50/60 Hz, 100-240V with US 120V Plug
Pump Head Material
DME 2-18 0.66 GPH (2.5 l/h) up to 261 psi (18 bar)
PP
PVDF
SS
DME 8-10 1.98 GPH (7.5 l/h) up to 145 psi (10 bar)
PP
PVDF
SS
DME 12-6 3.17 GPH (12 l/h) up to 89.9 psi (6.2 bar)
PP
F
PVD
SS
WEIGHTS: Shipping weights are approximate.
* 1/4" = 0.17 ID x 0.25 OD; 3/8" = 0.25 ID x 0.375 OD; 1/2" = 0.375 ID x 0.5 OD
Control
Variant
Valve Ball
Material
A
Ceramic1/4 or 3/8 *
AR
A
Ceramic1/4 or 3/8 *FKM
AR
A
AR
A
Ceramic1/4 or 3/8 *
AR
A
Ceramic1/4 or 3/8 *FKM
AR
A
AR
A
Ceramic1/4 or 3/8 *
AR
A
Ceram
AR
A
AR
Connections,Suction/
Discharge [in]
SS1/4" N PTFKM
SS1/4" N PTFKM
ic1/4 or 3/8*FKM
SS1/4" N PTFKM
Gasket
Material
EPDM
EPDM
EPDM
EPDM
EPDM
EPDM
FKM
FKM
FKM
FKM
FKM
FKM
DME and DMS
Control
Position
Model
Front DME2-18 A-PP/E/C-F-21RRB96470128
SideDME2-18 A-PP/E/C-S-21RRB96470129
Front DME2-18 A-PP/V/C-F-21RRB96470130
SideDME2-18 A-PP/V/C-S-21RRB96470131
Front DME2-18 AR-PP/E/C-F-21RRB 96470135
SideDME2-18 AR-PP/E/C-S-21RRB96470136
Front DME2-18 AR-PP/V/C-F-21RRB 96470137
SideDME2-18 AR-PP/V/C-S-21RRB96470138
Front DME2-18 A-PV/V/C-F-21RRB96470133
SideDME2-18 A-PV/V/C-S-21RRB96470134
Front DME2-18 AR-PV/V/C-F-21RRB 96462440
SideDME2-18 AR-PV/V/C-S-21RRB96470150
Front DME2-18 A-SS/V/SS-F-21VVB96470153
SideDME2-18 A-SS/V/SS-S-21VVB96470154
Front DME2-18 AR-SS/V/SS-F-21VVB 96470151
SideDME2-18 AR-SS/V/SS-S-21VVB 9 6470152
Front DME8-10 A-PP/E/C-F-21RRB96470158
SideDME8-10 A-PP/E/C-S-21RRB96470159
Front DME8-10 A-PP/V/C-F-21RRB96470160
SideDME8-10 A-PP/V/C-S-21RRB96470161
Front DME8-10 AR-PP/E/C-F-21RRB 96470219
SideDME8-10 AR-PP/E/C-S-21RRB96470224
Front DME8-10 AR-PP/V/C-F-21RRB 96462441
SideDME8-10 AR-PP/V/C-S-21RRB96470230
Front DME8-10 A-PV/V/C-F-21RRB96470217
SideDME8-10 A-PV/V/C-S-21RRB96470218
Front DME8-10 AR-PV/V/C-F-21RRB 96470243
SideDME8-10 AR-PV/V/C-S-21RRB96470248
Front DME8-10 A-SS/V/SS-F-21VVB96470268
SideDME8-10 A-SS/V/SS-S-21VVB96470272
Front DME8-10 AR-SS/V/SS-F-21VVB 96470251
SideDME8-10 AR-SS/V/SS-S-21VVB 9 6470255
Front DME12-6 A-PP/E/C-F-21RRB96470274
SideDME12-6 A-PP/E/C-S-21RRB96470275
Front DME12-6 A-PP/V/C-F-21RRB96470276
SideDME12-6 A-PP/V/C-S-21RRB96470279
Front DME12-6 AR-PP/E/C-F-21RRB 96470293
SideDME12-6 AR-PP/E/C-S-21RRB96470294
Front DME12-6 AR-PP/V/C-F-21RRB 96470296
SideDME12-6 AR-PP/V/C-S-21RRB96470297
Front DME12-6 A-PV/V/C-F-21RRB96470284
SideDME12-6 A-PV/V/C-S-21RRB96470288
Front DME12-6 AR-PV/V/C-F-21RRB 96470328
SideDME12-6 AR-PV/V/C-S-21RRB96470329
Front DME12-6 A-SS/V/SS-F-21VVB96470331
SideDME12-6 A-SS/V/SS-S-21VVB96470332
Front DME12-6 AR-SS/V/SS-F-21VVB 96470330
SideDME12-6AR-SS/V/SS-S-21VVB 96462476
Product
Number
Ship Weight
[lbs]
5.0
5.0
5.0
33
Pump selection
DME 19 to 48 - standard range
DME, 50/60 Hz, 100-240V with US 120V Plug
Pump Head
Material
DME 19-6 4.88 GPH (18.5 l/h) up to 87 psi (6 bar)
PP
PVDF
SS
DME 48-3 12.68 GPH (48 l/h) up to 37.7 psi (2.6 bar)
PP
PVDF
SS
WEIGHTS: Shipping weights are approximate.
* 1/4" = 0.17 ID x 0.25 OD; 3/8" = 0.25 ID x 0.375 OD; 1/2" = 0.375 ID x 0.5 OD
Control
Variant
A
AR
A
AR
A
AR
A
AR
A
AR
A
AR
Valve Ball
Material
Ceramic3/8 or 1/2*
Ceramic3/8 or 1/2*FKM
SS3/8" NPTFKM
Ceramic3/8 or 1/2*
Ceramic3/8 or 1/2*FKM
SS3/8" NPTFKM
Connections,
Suction/ Discharge
[in]
Gasket
Material
EPDM
FKM
EPDM
FKM
EPDM
FKM
EPDM
FKM
DME and DMS
Control
Position
Model
Front DME19-6 A-PP/E/C-F-21SSB96470333
SideDME19-6 A-PP/E/C-S-21SSB96470334
Front DME19-6 A-PP/V/C-F-21SSB96470350
SideDME19-6 A-PP/V/C-S-21SSB96470351
Front DME19-6 AR-PP/E/C-F-21SSB96462477
SideDME19-6 AR-PP/E/C-S-21SSB96470354
Front DME19-6 AR-PP/V/C-F-21SSB96470355
SideDME19-6 AR-PP/V/C-S-21SSB96470356
Front DME19-6 A-PV/V/C-F-21SSB96470352
SideDME19-6 A-PV/V/C-S-21SSB96470353
Front DME19-6 AR-PV/V/C-F-21SSB96470357
SideDME19-6 AR-PV/V/C-S-21SSB96470358
Front DME19-6 A-SS/V/SS-F-21YYB96470361
SideDME19-6 A-SS/V/SS-S-21YYB96470362
Front DME19-6 AR-SS/V/SS-F-21YYB 96470359
SideDME19-6 AR-SS/V/SS-S-21YYB 96470360
Front DME48-3 A-PP/E/C-F-21SSB96470363
SideDME48-3 A-PP/E/C-S-21SSB96470364
Front DME48-3 A-PP/V/C-F-21SSB96470365
SideDME48-3 A-PP/V/C-S-21SSB96470366
Front DME48-3 AR-PP/E/C-F-21SSB96470370
SideDME48-3 AR-PP/E/C-S-21SSB96470371
Front DME48-3 AR-PP/V/C-F-21SSB96470372
SideDME48-3 AR-PP/V/C-S-21SSB96470373
Front DME48-3 A-PV/V/C-F-21SSB96470367
SideDME48-3 A-PV/V/C-S-21SSB96470369
Front DME48-3 AR-PV/V/C-F-21SSB96470374
SideDME48-3 AR-PV/V/C-S-21SSB96462491
Front DME48-3 A-SS/V/SS-F-21YYB96470377
SideDME48-3 A-SS/V/SS-S-21YYB96470378
Front DME48-3 AR-SS/V/SS-F-21YYB 96470375
SideDME48-3 AR-SS/V/SS-S-21YYB 96470376
Product
Number
Ship
Weight
[lbs]
7.5
7.5
34
Pump selection
DME 60 to 150 - standard range
DME, 50/60 Hz, 100-240V with US 120V Plug
Pump Head
Material
DME 60-10 15.85 GPH (60 l/h) up to 145 psi (10 bar)
PP
PVDF
SS
DME 150-4 39.6 GPH (150 l/h) up to 58 psi (4 bar)
PP
PVDF
SS
GHTS: Shipping weights are approximate.
WEI
Control
Variant
AR
B
AR
B
AR
B
AR
B
AR
B
AR
B
Valve Ball
Material
Ceramic3/4" FNPT
Ceramic3/4" FNPTFKM
SS3/4" FNPTFKM
Ceramic3/4" FNPT
Ceramic3/4" FNPTFKM
SS3/4" FNPTFKM
Connections,
Suction/
Discharge
Gasket
Material
EPDM
FKM
EPDM
FKM
EPDM
FKM
EPDM
FKM
DME and DMS
Control
Position
FrontDME60-10 AR-PP/E/C-F-21A3A3B96528925
FrontDME60-10 AR-PP/V/C-F-21A3A3B96528927
FrontDME60-10 B-PP/E/C-F-21A3A3B965289 73
FrontDME60-10 B-PP/V/C-F-21A3A3B965289 75
FrontDME60-10 AR-PV/V/C-F-21A3A3B96528929
FrontDME60-10 B-PV/V/C-F-21A3A3B965289 77
FrontDME60-10 AR-SS/V/SS-F-21A3A3B96528971
FrontDME60-10 B-SS/V/SS-F-21A3A3B96528980
FrontDME150-4 AR-PP/E/C-F-21A3A3B96528982
FrontDME150-4 AR-PP/V/C-F-21A3A3B96528984
FrontDME150-4 B-PP/E/C-F-21A3A3B96528990
FrontDME150-4 B-PP/V/C-F-21A3A3B96528994
FrontDME150-4 AR-PV/V/C-F-21A3A3B96528986
FrontDME150-4 B-PV/V/C-F-21A3A3B96528998
FrontDME150-4 AR-SS/V/SS-F-21A3A3B96528988
FrontDME150-4 B-SS/V/SS-F-21A3A3B96529001
Model
SideDME60-10 AR-PP/E/C-S-21A3A3B96528926
SideDME60-10 AR-PP/V/C-S-21A3A3B96528928
SideDME60-10 B-PP/E/C-S-21A3A3B96528974
SideDME60-10 B-PP/V/C-S-21A3A3B96528976
SideDME60-10 AR-PV/V/C-S-21A3A3B96528970
SideDME60-10 B-PV/V/C-S-21A3A3B96528978
SideDME60-10 AR-SS/V/SS-S-21A3A3B96528972
SideDME60-10 B-SS/V/SS-S-21A3A3B96528981
SideDME150-4 AR-PP/E/C-S-21A3A3B96528983
SideDME150-4 AR-PP/V/C-S-21A3A3B96528985
SideDME150-4 B-PP/E/C-S-21A3A3B96528991
SideDME150-4 B-PP/V/C-S-21A3A3B96528996
SideDME150-4 AR-PV/V/C-S-21A3A3B96528987
SideDME150-4 B-PV/V/C-S-21A3A3B96528999
SideDME150-4 AR-SS/V/SS-S-21A3A3B96528989
SideDME150-4 B-SS/V/SS-S-21A3A3B965290
Product
Number
03
Ship
Weight
[lbs]
25
26
35
Pump selection
DME 375 to 940 - standard range
DME, 50/60 Hz, 100-240V with US 120V Plug
Pump Head
Material
DME 375-10 99.06 GPH (375 l/h) up to 145 psi (10 bar)
PP
PVDF
SS
DME 940-4 248.3 GPH (940 l/h) up to 58 psi (4 bar)
PP
PVDF
SS
WEIGHTS: Shipping weights are approximate.
Control
Variant
AR
B
AR
B
AR
B
AR
B
AR
B
AR
B
Valve Ball
Material
Glass1 1/4" FNPT
Glass1 1/4" FNPTFKM
SS1 1/4" FNPTFKM
Glass1 1/4" FNPT
Glass1 1/4" FNPTFKM
SS1 1/4" FNPTFKM
Connections,
Suction/
Discharge
Gasket
Material
EPDM
EPDM
EPDM
EPDM
FKM
FKM
FKM
FKM
DME and DMS
Control
Position
FrontDME375-10 AR-PP/E/G-F-21A4A4B96529006
FrontDME375-10 AR-PP/V/G-F-21A4A4B96529116
FrontDME375-10 B-PP/E/G-F-21A4A4B96529123
FrontDME375-10 B-PP/V/G-F-21A4A4B96529125
FrontDME375-10 AR-PV/V/G-F-21A4A4B96529118
FrontDME375-10 B-PV/V/G-F-21A4A4B96529128
FrontDME375-10 AR-SS/V/SS-F-21A4A4B96529120
FrontDME375-10 B-SS/V/SS-F-21A4A4B96529132
FrontDME940-4 AR-PP/ E/G-F-21A4A4B96529137
FrontDME940-4 AR-PP/ V/G-F-21A4A4B96529151
FrontDME940-4 B-PP/E/G-F-21A4A4B96529163
FrontDME940-4 B-PP/V/G-F-21A4A4B96529165
FrontDME940-4 AR-PV/ V/G-F-21A4A4B96529158
FrontDME940-4 B-PV/V/G-F-21A4A4B96529167
FrontDME940-4 AR-SS/ V/SS-F-21A4A4B96529161
FrontDME940-4 B-SS/V/SS-F-21A4A4B96529169
Model
SideDME375-10 AR-PP/E/G-S-21A4A4B96529114
SideDME375-10 AR-PP/V/G-S-21A4A4B96529117
SideDME375-10 B-PP/E/G-S-21A4A4B96529124
SideDME375-10 B-PP/V/G-S-21A4A4B96529126
SideDME375-10 AR-PV/V/G-S-21A4A4B96529119
SideDME375-10 B-PV/V/G-S-21A4A4B96529130
SideDME375-10 AR-SS/V/SS-S-21A4A4B96529121
SideDME375-10 B-SS/V/SS-S-21A4A4B96529135
SideDME940-4 AR-PP/E/G-S-21A 4A4B96529139
SideDME940-4 AR-PP/V/G-S-21A 4A4B96529155
SideDME940-4 B-PP/E/G-S-21A4A4B96529164
SideDME940-4 B-PP/V/G-S-21A4A4B96529166
SideDME940-4 AR-PV/V/G-S-21A 4A4B96529160
SideDME940-4 B-PV/V/G-S-21A4A4B96529168
SideDME940-4 AR-SS/V/SS-S-21 A4A4B96529162
SideDME940-4 B-SS/V/SS-S-21A4A4B96529170
Product
Number
Ship
Weight
[lbs]
47
50
36
Pump selection
DMS 2 to 4 - standard range
DMS, 60 Hz, 120V with US 120V Plug
Pump Head
Material
DMS 2-11 0.66 GPH (2.5 l/h) up to 160 psi (11 bar)
PP
PVDF
SS
DMS 4-7 1.05 GPH (4 l/h) up to 101.5 psi (7 bar)
PP
PVDF
SS
WEIGHTS: Shipping weights are approximate.
* See pg 32 for DMS D capacity range.
** 1/4" = 0.17 ID x 0.25 OD; 3/8" = 0.25 ID x 0.375 OD; 1/2" = 0.375 ID x 0.5 OD.
Control
Variant
Valve Ball
Material
A
AR
D*
ARFKM
D*FK MNoneDMS2-11 D-PV/V/C-X-21RRB96508019
ARFKM
D*FK MNoneDMS2-11 D-SS/V/SS-X-21VVB96508090
AR
D*
ARFKM
D*FKMNoneDMS4-7 D-PV/V/C-X-21RRB96508093
ARFKM
D*FKMNoneDMS4-7 D-SS/V/SS-X -21VVB96508094
Ceramic1/4 or 3/8**
B
A
Ceramic1/4 or 3/8**
BFKMFrontDMS2-11 B-PV/V/C-F-21RRB96469467
A
SS1/4" NPT
BFKMFrontDMS2-11 B-SS/V/SS-F-21VVB96462492
A
Ceramic1/4 or 3/8**
B
A
Ceramic1/4 or 3/8**
BFKMFrontDMS4-7 B-PV/V/C-F-21RRB96469514
A
SS
BFKMFrontDMS4-7 B-SS/V/SS-F-21VVB96462515
Connections,
Suction/Discharge
[in]
T
1/4" NP
Gasket
Material
EPDM
FKM
EPDM
FKM
EPDMFrontDMS2-11 B-PP/E/C-F-21RRB96469451
FKMFrontDMS2-11 B-PP/V/C-F-21RRB96469456
EPDMNoneDMS2-11 D-PP/E/C-X-21RRB96508016
FKMNoneDMS2-11 D-PP/V/C-X-21RRB96508017
FKM
FKM
EPDM
FKM
EPDM
FKM
EPDMFrontDMS4-7 B-PP/E/C-F-21RRB96469513
FKMFrontDMS4-7 B-PP/V/C-F-21RRB96469493
EPDMNoneDMS4-7 D-PP/E/C-X-21RRB96508091
FKMNoneDMS4-7 D-PP/V/C-X-21RRB96508092
FKM
FKM
DME and DMS
Control
Position
Model
FrontDMS2-11 A-PP/E/C-F-21RRB96469328
SideDMS2-11 A-PP/E/C-S-21RRB96469358
FrontDMS2-11 A-PP/V/C-F-21RRB96469376
SideDMS2-11 A-PP/V/C-S-21RRB96469377
FrontDMS2-11 AR-PP/E/C-F-21RRB96469391
SideDMS2-11 AR-PP/E/C-S-21RRB96469392
FrontDMS2-11 AR-PP/V/C-F-21RRB96469394
SideDMS2-11 AR-PP/V/C-S-21RRB96469399
FrontDMS2-11 A-PV/V/C-F-21RRB96469378
SideDMS2-11 A-PV/V/C-S-21RRB96469390
FrontDMS2-11 AR-PV/V/C-F-21RRB96469403
SideDMS2-11 AR-PV/V/C-S-21RRB96469408
FrontDMS2-11 A-SS/V/SS-F-21VVB96469419
SideDMS2-11 A-SS/V/SS-S-21VVB96469424
FrontDMS2-11 AR-SS/V/SS-F-21VVB96469411
SideDMS2-11 AR-SS/V/SS-S-21VVB96469414
FrontDMS4-7 A-PP/E/C-F -21RRB96469468
SideDMS4-7 A-PP/E/C-S-21RRB96469469
FrontDMS4-7 A-PP/V/C-F -21RRB96469470
SideDMS4-7 A-PP/V/C-S-21RRB96469471
FrontDMS4-7 AR-PP/E/C- F-21RRB96469474
SideDMS4-7 AR-PP/E/C-S-21RRB96469487
FrontDMS4-7 AR-PP/V/C- F-21RRB96469489
SideDMS4-7 AR-PP/V/C-S-21RRB96469490
FrontDMS4-7 A-PV/V/C-F -21RRB96469472
SideDMS4-7 A-PV/V/C-S-21RRB96469473
FrontDMS4-7 AR-PV/V/C- F-21RRB96469492
SideDMS4-7 AR-PV/V/C-S-21RRB96469508
FrontDMS4-7 A-SS/V/SS-F-21VVB96469511
SideDMS4-7 A-SS/V/SS-S-21VVB96469512
FrontDMS4-7 AR-SS/V/SS-F-21VVB96469509
SideDMS4-7 AR-SS/V/SS-S-21VVB96469510
Product
Number
Ship
Weight
[lbs]
5,0
5.0
37
Pump selection
DMS 8 to 12 - standard range
DMS, 60 Hz, 120V with US 120V Plug
Pump Head
Material
DMS 8-5 1.98 GPH (7.5 l/h) up to 78.3 psi (5.4 bar)
PP
PVDF
SS
DMS 12-3 3.17 GPH (12 l/h) up to 49.3 psi (3.4 bar)
PP
PVDF
SS
WEIGHTS: Shipping weights are approximate.
* See pg 32 for DMS D capacity range.
** 1/4" = 0.17 ID x 0.25 OD; 3/8" = 0.25 ID x 0.375 OD; 1/2" = 0.375 ID x 0.5 OD.
Control
Variant
Valve Ball
Material
A
AR
B
D*
A
ARFKM
BFKMFrontDMS8-5 B-PV/V/C-F-21RRB96469682
D*FKMNoneDMS8-5 D-PV/V/C-X-21RRB96508098
A
ARFKM
BFKMFrontDMS8-5 B-SS/V/SS-F-21VVB96462686
D*FKMNoneDMS8-5 D-SS/V/SS-X-21VVB96508099
A
AR
B
D*
A
ARFKM
BFKMFrontDMS12-3 B-PV/V/C-F-21RRB96469786
D*FKMNoneDMS12-3 D-PV/V/C-X-21RRB96508103
A
ARFKM
BFKMFrontDMS12-3 B-SS/V/SS-F-21VVB96469791
D*FKMNoneDMS12-3 D-SS/V/SS-X-21VVB96508104
Ceramic1/4 or 3/8**
Ceramic1/4 or 3/8**
SS1/4" NPT
Ceramic1/4 or 3/8**
Ceramic1/4 or 3/8**
SS
Connections,
Suction/ Discharge
[in]
T
1/4" NP
Gasket
Material
EPDM
FKM
EPDM
FKM
EPDMFrontDMS8-5 B-PP/E/C-F-21RRB96469676
FKMFrontDMS8-5 B-PP/V/C-F-21RRB96469678
EPDMNoneDMS8-5 D-PP/E/C-X-21RRB965080 95
FKMNoneDMS8-5 D-PP/V/C-X-21RRB96508097
FKM
FKM
EPDM
FKM
EPDM
FKM
EPDMFrontDMS12-3 B-PP/E/C-F-21RRB96469775
FKMFrontDMS12-3 B-PP/V/C-F-21RRB96469777
EPDMNoneDMS12-3 D-PP/E/C-X-21RRB96508100
FKMNoneDMS12-3 D-PP/V/C-X-21RRB96508101
FKM
FKM
DME and DMS
Control
Position
FrontDMS8-5 A-PP/E/C-F-21RRB96469516
SideDMS8-5 A-PP/E/C-S-21RRB96469523
FrontDMS8-5 A-PP/V/C-F-21RRB96469529
SideDMS8-5 A-PP/V/C-S-21RRB96469534
FrontDMS8-5 AR-PP/E/C-F-21RRB96462494
SideDMS8-5 AR-PP/E/C-S-21RRB96469637
FrontDMS8-5 AR-PP/V/C-F-21RRB96469638
SideDMS8-5 AR-PP/V/C-S-21RRB96469651
FrontDMS8-5 A-PV/V/C-F-21RRB96469537
SideDMS8-5 A-PV/V/C-S-21RRB96469636
FrontDMS8-5 AR-PV/V/C-F-21RRB96469656
SideDMS8-5 AR-PV/V/C-S-21RRB96469659
FrontDMS8-5 A-SS/V/SS-F-21VVB96469672
SideDMS8-5 A-SS/V/SS-S-21VVB96469675
FrontDMS8-5 AR-SS/V/SS-F-21VVB96469663
SideDMS8-5 AR-SS/V/SS-S-21VVB96469668
FrontDMS12-3 A-PP/E/C-F-21RRB96469700
SideDMS12-3 A-PP/E/C-S-21RRB96469703
FrontDMS12-3 A-PP/V/C-F-21RRB96469707
SideDMS12-3 A-PP/V/C-S-21RRB96469711
FrontDMS12-3 AR-PP/E/C-F-21RRB96469722
SideDMS12-3 AR-PP/E/C-S-21RRB96469726
FrontDMS12-3 AR-PP/V/C-F-21RRB96469730
SideDMS12-3 AR-PP/V/C-S-21RRB96469734
FrontDMS12-3 A-PV/V/C-F-21RRB96469714
SideDMS12-3 A-PV/V/C-S-21RRB96469718
FrontDMS12-3 AR-PV/V/C-F-21RRB96469735
SideDMS12-3 AR-PV/V/C-S-21RRB96462495
FrontDMS12-3 A-SS/V/SS-F-21VVB96469766
SideDMS12-3 A-SS/V/SS-S-21VVB96469771
FrontDMS12-3 AR-SS/V/SS-F-21VVB96469763
SideDMS12-3 AR-SS/V/SS-S-21VVB96469764
Model
Material
Number
Ship
Weight
[lbs]
5.0
5.0
38
Pump selection
Non-standard options
OptionAvailable with
Spring-loaded check valvesDME, DMS
ProfibusDME
GENibusDME 2 to 48
PTFE check valves with Ceramic or PTFE
balls
PTFE balls in PP or PVDF check valvesDME 2 to 48, DMS
SS balls in PP or PVDF check valvesDME, DMS
1/2" NPT connections on PP or PVDF
pumps
Metric inlet/discharge connectionDME, DMS
International supply voltages/plug typesDME, DMS
PTFE gasketsDME 60 to 940
Hastelloy C ballsDME 60 to 940
Please contact the factory for ordering information.
DME 2 to 48, DMS
DME 2 to 48, DMS
DME and DMS
39
Pumped liquids
DME and DMS
List of pumped liquids
The resistance table below is intended as a general
guide for material resistance (at room temperature),
and does not replace testing of the chemicals and pump
materials under specific working conditions.
The data shown are based upon information from
various sources available, but many factors (purity,
temperature, abrasive particles, etc.) may affect the
chemical resistance of a given material. Note: Some of
the liquids in this table may be toxic, corrosive or
hazardous.
Cable and plug for connection of pump to external
control devices, such as process controllers, flow
meters, start/stop contacts, and level sensors.
Grundfos level control units are factory-fitted with cable
and plug connection for Grundfos dosing pumps.
The cables and plugs fit all dosing pumps, types DME
and DMS-A.
2
Cable material: PUR (0.34 mm
Plug type: M12.
)
Cable and plug
TM01 8955 0900
Signal
Pulse, 0/4-20 mA, start/stop5
Dual-level or stop signal4
Stop dosing input and output*5
Alarm Relay Cable*
)
*
Only DME 60 to 940
Note - DME 2 to 48 and DMS AR versions have alarm relay cable hard-wired to pump.
Number of
poles
3
Control cable with plug
Plug terminal without cable-96440449
Control cable with plug6.596440450
Control cable with plug1696449451
Plug terminal without cable-96440452
Extension cable6.596483235
Control cable with plug6.596527109
Control cable with plug1696527111
Relay cable with plug6.596534214
Relay cable with plug1696534215
Type
Cable length
[ft]
6.596440447
1696440448
Product number
43
Accessories
Diaphragm leakage sensor (DME 60 to 940)
Optoelectronic leakage sensor to be inserted in the
drain hole behind the diaphragm for sensing diaphragm
breakage or leakage.
The sensor unit consists of:
• Transmitter receiver
• Holder for fitting sensor in the backplate
• M12 plug and wire to transmit signal to pump.
When the liquid gets into contact with the sensor, the
light refraction changes, causing the sensor to emit a
signal.
The signal emitted from the sensor triggers the pump
to stop dosing and give pump output alarm.
Diaphragm leakage sensor
GR 8211p
Pump typeSizeTypeCable length [m] Product number
DME 60-940 (l/h) M12
Leakage sensor
M12
0.5 m96534443
44
Accessories
Tubing
Tubing in various materials, sizes and lengths.
Tubing
TM01 8958 0900
Inner/outer diameter
(in)
0.17 x 1/4PVC852091127749
1/4 x 3/8
3/8 x 1/2PE123
Material
PVC7310091127750
PE192
ETFE29010091127753
Maximum pressure
(psi)
Length
(ft)
2091127825
10091127751
2091127826
10091127752
Product
Number
45
Accessories
Foot valve
Foot valve complete with non-return valve, strainer and
tube or pipe connection.
Dimensions
DN 4, DN 8DN 6, DN 10, DN 15, DN 20, DN 25
Tubing/non-return valveHose clampPipe cementing
Foot valve
TM01 9285 1600/GR8109
Non-return valve
TM01 9276 1600/TM02 6433
Max flow rate
GPH (l/h)HousingGasketBallTypeID/OD or NPTø (in)L (in)
4 (15)DN 4
12.7 (48)DN 6SSCSMSSNPT1/4"1.31.596479794
19 (72)DN 8
39.6 (150)DN 10SSCSMSSNPT1/2"22.296480625
99.1 (375)DN 15SSCSMSSNPT1/2"2.53.796480627
248.3 (940)DN 25SSCSMSSNPT1"3.54.796480628
248.3 (940)NPT 3/4"
248.3 (940)NPT 1 1/4"
Size
PVDFFKMCeramicTubing
PVDFFKMCeramicTubing
PVDFFKM96566139
PVDFFKM96566147
MaterialsConnectionDimensions
EPDMCeramicTubing
PP
FKMCeramicTubing
EPDMCeramicTubing
PP
PP
SSFKMSS96537921
PPEPDM
PPFKM96566146
SSFKMSS96537970
FKMCeramicTubing
EPDM
FKM96566138
Ceramic
Glass
NPT3/4"3/4"
NPT1 1/4"1 1/4"
0.17" x 1/4"
1/4" x 3/8"96479782
0.17" x 1/4"96480589
1/4" x 3/8"96479784
0.17" x 1/4"96480589
1/4" x 3/8"96479784
1/4" x 3/8"
3/8" x 1/2"96479798
1/4" x 3/8"96480622
3/8" x 1/2"96480623
1/4" x 3/8"96480624
1/4" x 3/8"96479801
TM01 2201 1600
Product Number
96480503
1.42.8
96480621
1.42.8
96566136
96566145
TM01 9277 1600
46
Accessories
Injection valve
Injection valve complete with spring-loaded non-return
valve, injection pipe and tube or pipe connection.
Spring material: Hastelloy
Maximum temperature:
PP, PVDF:122 F (50 °C)
PVC:104 F (40 °C)
Stainless steel: 176 F (80 °C).
Dimensions
DN 4, DN 8DN 6, DN 10, DN 15, DN 20, DN 25
d
Injection valve
GR8107 - GR7098
L
Non-return valve
TM01 9278 3100 - TM02 6434
Max flow rate
GPH. (l/h)HousingGasketBallTypeID/OD or NPTd (in)L (in)
3.2 (12)DN 4
19 (72)
19 (72)DN 8
39.6 (150)DN 10
248.3 (940)NPT 3/4"
248.3 (940)N PT 1 1/4"
Size
PVDFFKMCeramicTubing
DN 6
DN 61/2"96480629
PVDFFKMCeramicTubing
PVDFFKM96566144
PVDFFKM96566152
MaterialsConnectionDimensions
EPDMCeramicTubing
PP
FKMCeramicTubing
SSAFSSNPT
PP
PVCFK MGlassTubing1/4" x 3/8"1/2" NPT3.991129485
SSCSMSSNPT3/8"1" NPT3.996480640
PP
SSFKMSS96537923
PPEPDM
PPFKM96566149
SSFKMSS96537971
EPDMCeramicTubing
FKMCeramicTubing1/4" x 3/8"96480646
EPDM
FKM96566143
Ceramic
Glass
NPT3/4"3/4" NPT
NPT1 1/4"1 1/4" NPT
TM01 9279 1600
0.17" x 1/4"
1/4" x 3/8"96479805
0.17" x 1/4"96480642
1/4" x 3/8"96479806
0.17" x 1/4"96480643
1/4" x 3/8"96479807
1/4"
1/4" x 3/8"
3/8" x 1/2"96480645
3/8" x 1/2"96479808
1/4" x 3/8"96480647
3/8"x1/2"96479809
1/2" NPT1.3
1/2" NPT3.9
1/2" NPT1.3
Product Number
96480641
96479804
96480644
96566142
96566148
47
Accessories
Hot injection valve
The hot injection valve kit is a complete assembly with
shut-off valve, pipe, and tubing connection fitting for
chemical injection into steam and hot water applications.
It allows for direct dosing into systems with a maximum
liquid temperature of 302 F (150 °C) at the point of
injection.
The hot injection valve kit is delivered non-assembled
to facilitate adaptation to the actual appli cation.
Hot injection valve
Materials:
Shut-off ball valve 316 SS
Pipe316 SS
Pipe connection316 SS
Tubing connectionPVDF
Max. injection point temperature302 F (150 °C)
Dimensions:
Shut-off ball valve 1/2"
Pipe8/10 mm
Pipe connection1/2"
Tubing connection
Max. flow rate GPH [l/h]Size
5.3 (20)D N 4PVDFFKMCeramicTubing3/8" / 1/2"96567703
3/8" ID 1/2" OD.
MaterialConnection
ConnectionGasketBallTypeTubing diameter
GR 7506
Product number
48
Accessories
Multifunction valve
Compact valve unit for direct mounting on the pump
discharge connection. The valve has four functions:
PVCEPDMPTFEM30 x 3.5M30 x 3.596496470
PVCFKMPTFEM30 x 3.5M30 x 3.596446752
MaterialsDimensions
EPDMPTFEM30 x 3.5M30 x 3.596440584
FKMPTFEM30 x 3.5M30 x 3.596440585
Product
Number
TM01 9583 2100 - TM01 8961 0900
TM01 2220 1498
49
Accessories
Dosing monitor
The dosing monitor is used in connection with the
dosing monitoring function of DME 2 to 48, and DMS-A,
AR pumps.
The monitor sends a pulse signal (closed contact) for
every measured dosing stroke.
As the DME pump will often operate without pulsation
on the discharge side, the monitor must always be
installed on the suction side.
The monitor for a DMS pump can be installed on both
suction and discharge side.
Maximum pressure:145 psi (10 bar)
Maximum volume:13 GPH (50 l/h)
Maximum liquid temperature:95 F (35 °C)
Maximum liquid viscosity:2 0 cps
Maximum load of pulse
transmitter (reed contact):48 VAC/VDC, 0.5 A
Materials in contact with liquid:PMMA/PVC/FKM.
Dosing monitor
TM02 2472 4401
Dosing stroke
Dosing stroke
measured
Monitor mounted on suction
side (DME and DMS)
measured
Monitor mounted on discharge
side (DMS only)
Monitor mounted in dosing tube.
In discharge tube: DMS
In suction tube: DME and DMS
Dosing stroke
measured
Selection table
MountingPump headGasketMaterialConnection kitProduct number
FKMPVDF
InlinePP, PVDF
Pump discharge*PP, PVDF
Pump inletPP, PVDF
*Not suitable for DME pumps
Not stuitable for SS pump heads
FKMPP96470725
EPDMPVDF96493010
FKMNot needed96470723
EPDMPump connection is used on inlet of moni tor96492899
FKMNot needed96470724
EPDMPump connection is used on inlet of moni tor96493011
Includes 1/4", 3/8" and 1/2" tubing connections
TM02 2029 3201 - TM02 2030 3201 - TM02 2031 3201
96470726
50
Accessories
Flow indicator
The flow indicator is used for discharge monitoring.
When the dosing pump is discharging liquid, the white
ball will jump in the transparent pipe. Each dosing
stroke causes a ball jump. The design of the flow indicator allows ball movements to be seen at flow rates
from 0.026 to 11.9 GPH.
At a steady flow, the ball will always be in the top position.
The flow indicator installs and retrofits easily.
Material:PVC grey, PVC transparent,
PVDF, FKM, ceramic AI
Maximum pressure:145 psi (10 bar)
Maximum pulsed flow:11.9 GPH (45 l/h).
2O3
.
Flow indicator
Dimensions
Pump type
DME 2 to 48
DMS
TM01 9791 3100
TM01 9800 3200
Dimensions
ABC [mm]D [mm]
M30 x 3.5M30 x 3.5445596446763
Product number
51
Accessories
Adaptor
The adaptors are used for the connection of DME and
DMS pumps to suction and discharge tubing sizes other
than Grundfos standard sizes.
The product number comprises two sets.
Adaptor
TM02 2470 4401
Tubing connections (without union nut)
Pump type
DM E 2 to 48
DMS
IDOD
0.17"1/4"
1/4"3/8"
3/8"1/2"
Size
Male threaded connection (with union nut)
Pump type
P P or P V D F
DME 2 to 48, DMS
Union nutMale NPT
M30 x 3.51/2"
Connection
Female threaded connection (with union nut)
Pump type
DME 60, DME 1503/4" NPT
DME 375, DME 9401 1/4" NPT
Size
ID
MaterialProduct Number
PP91128441
PVDF91128442
PP91128437
PVDF91128438
PP91128439
PVDF91128440
MaterialProduct Number
PP96560564
PVDF96560570
MaterialProduct Number
PVC96537892
SS96537894
PVC96537893
SS96537895
52
Accessories
Level control unit
Level control unit
For dosing pumps with level control input (variant A),
complete with level sensors (NO-contacts), ceramic
weight, cable and plug for pump connection.
Material:PVC
Level cable length:8.2 ft
Level plug type:M12, 4-pole
Maximum load of
level contacts:50 V, 0.5 A
Function of level contacts:
Low level/empty tank = closed contact
Product number:96440539.
Dimensions
TM01 9567 1600
TM01 9587 2100
53
Accessories
Rigid suction line
The pre-assembled rigid suction line features an adjustable length for use with a tank. It consists of foot valve
with strainer, rigid suction pipe, tank connection thread,
and suction tube.
For control variant A pumps, the suction line is available
with level sensors (NO-contacts) for warning and
empty-tank signals, supplied complete with cable and
plug for pump connection.
Material:PVC
Material, wetted parts:PVC, glass
Suction tubing length:4.9 ft, PVC-tube
Level cable length:4.9 ft
Level plug type:M12, 4-pole
Maximum flow:13 GPH (50 l/h)
Maximum load of
level contacts:50 V, 0.5 A
Function of level contacts:
Low level/empty tank =closed contact
PE screw cap:15/16 in (33.5 mm)
Product Number:96483418.
Adjustable valve for installation in the discharge tube.
• Installed in-line, the valve functions as a counterpressure valve optimising dosing accuracy into systems with fluctuating pressure or as anti-siphoning
valve when dosing into pressureless systems.
• Installed in a T-connection with the valve outlet connected to the tank, the valve functions as a pressure
relief valve or a safety valve, protecting the pump
and the discharge tube against excessive pressures.
• counter-pressure and relief valve
Valve diaphragm material: PTFE
Pressure range of counter-pressure and relief valve:
0 to 145 psi (0 to 10 bar).
Back-pressure and relief valve
Valve assembly
TM01 9590
Valve functions
Back-pressure
and relief valve
TM01 9293 1600
Maximum FlowDimensions
Size
DN 66.6 (25)1/4"155
DN 1019.8 (75)3/8"174
DN 1555.5 (210)1/2"180
GPH (l/h)AH (mm)TypeSize (ID/OD)
Housing material
PVC
316 SSNPT1/4"96524669
PVC
316 SSNPT3/8"96524672
PVCNPT1/2"96524673
316 SSNPT1/2"96524674
Connections
0.17"/ 1/4"96524665
Tubing
NPT1/4"96524668
Tubing1/4" / 3/8"96524670
NPT3/8"96524671
1/4" / 3/8"96524666
3/8" / 1/2"96524667
Product Number
58
Accessories
Vent valve
Manual vent valve for direct fiting into the DME 2 to 48
and DMS pumps.
Vent valve
GR 8210
Pump type
DME 2 to 48
DMS
Valve materials
HousingGasketBall
PPEPDM
PPFKM96534794
PVFKM96534796
Ceramic1/4”
Vent connectionProduct number
96534792
59
Accessories
Automatic vent valve
Automatic vent valve for direct fitting on the pump
discharge connection.
Valve housing material: PMMA/PVC
O-ring material:FK M
Valve ball material:Glass
Valve seat material:PVDF
Pump head material:PP/PVDF
Power cable length:5 ft
Opening pressure:145 psi (10 bar)
Maximum flow:11.9 GPH (45 l/h)
Supply voltage:1 x 120V, 50-60 Hz
Plug type:US.
Automatic vent valve
Automatic vent valve with timer (mm)
A
TM01 9591 2100/TM01 9592 2100
The valve is available with and with out ti mer.
With timer:
The valve is continuously connected to the power
supply. The opening time and opening intervals are set
on the timer.
Without timer:
The valve will open when power is supplied to the valve.
This version is ideal for operation in connection with a
dosing monitor.
B
Pump type
DME 2 to 48
DMS
Dimensions
A + B
M30 x 3.51 x 120 V, 50-60 HzUS9644108496471086
60
VoltagePlug
TM01 2218 1498
Product number
With timerWithout timer
Accessories
Pulsation dampener
The pulsation dampener can be installed both in the
suction or discharge line for reducing pressure surges,
thereby ensuring a steady flow. The dampener is
particularly suitable for long discharge lines and/or lines
with a small diameter.
Installed in the discharge line, the dampener can be
used to optimize dosing accuracy and to protect the
pump and discharge line against pressure surges.
Depending on the system pressure, it may be necessary to install a back-pressure valve after the dampener
to optimize its function.
Maximum pressure: 145 psi (10 bar).
Pulsation dampener
Size 80Size 250Sizes 750
Pulsation dampener
TM01 9593 2100
Size
25039.6 (150)
75099 (375)
Maximum
flow rate
[l/h]
8015.9 (60)
TM01 2206 1498
MaterialsConne ctionsDimensions [mm]
HousingDiaphragmType
PPCSM
PVCCSM96480706
PVCFKM96479972
PP
PVC
PP
PVC
CSM
FKM96480693
CSM96480696
FKM96480695
CSM
FKM96480698
CSM96480704
FKM96480703
Tubing1/4" / 3/8"172G 3/4"M650
NPT1/2"314 140 G 1 1/4"M 858
NPT1/2"363 347 G 1 1/4"Ø972
Inner/outer tubing or
pipe diameters/
thread
TM01 2207 1498
AB C D E
Product
number
96479971
96480694
96480700
TM01 22081498
61
Accessories
Priming aid
Priming aid
The priming aid is a transparent, air-tight collector with
a screw cap on top. It is mounted between the tank and
the pump. The inlet from the tank and the outlet to the
pump are both at the bottom of the collector.
The priming aid is supplied with a bracket for wall
mounting and a rod for mounting on top of the tank.
The priming aid has the following functions:
• Priming.
The priming aid facilitates priming in case of frequent stops and/or high suction lifts by eliminating
or reducing the dry-suction phase.
• Gas trap.
Gas occurring in the suction tube is trapped in the
top of the priming aid to prevent it from en tering th e
dosing head.
• Pulsation dampening.
The dampening gas cushion in the top of th e priming aid reduces pressure surges, resulting in o ptimum dosing accuracy and reduced risk of
cavitation.
Material: PVC.
Size 95
TM01 2214 1498
Size 250
Priming capacity
size [ml]
95
2501/4"3/8"96480690
TypeIDOD
Tubing
62
TM01 9597 2100
Connection
0.17"1/4"96480692
1/4"3/8"96479970
Product Number
TM01 2216 1498
Accessories
Tank
Closed cylindrical tank with screw cap and threaded
connection for rigid suction line.
Material:PE
Liquid temperature: Minimum: -4 F (-20 °C)
Maximum: 113 F (45 °C).
Pump mounting plate:
The DME 2 to 48 and DMS pumps can be mounted
direct on the tank top by means of adapter plates.
Material: PP.
DME 2 to DME 12 and DMS: 96446765
DME 19 and DME 48:96446766.
Floor mounting bracket:
Material: PE
Set of four: 96446767.