Products manufactured by GRUNDFOS PUMPS CORPORA TION (Grundfos) are warranted
to the original user only to be free of defects in material and workmanship for a period of
24 months from date of installation, but not more than 30 months from date of manufacture.
Grundfos' liability under this warranty shall be limited to repairing or replacing at Grundfos'
option, without charge, F.O.B. Grundfos' factory or authorized service station, any product of
Grundfos' manufacture. Grundfos will not be liable for any costs of removal, installation,
transportation, or any other charges which may arise in connection with a warranty claim.
Products which are sold but not manufactured by Grundfos are subject to the warranty
provided by the manufacturer of said products and not by Grundfos' warranty. Grundfos will
not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in
accordance with Grundfos' printed installation and operating instructions.
To obtain service under this warranty, the defective product must be returned to the distributor or dealer of Grundfos' products from which it was purchased together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise
provided, the distributor or dealer will contact Grundfos or an authorized service station for
instructions. Any defective product to be returned to Grundfos or a service station must be
sent freight prepaid; documentation supporting the warranty claim and/or a Return Material
Authorization must be included if so instructed.
GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLA TION, USE, OR ANY OTHER
CAUSES. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANT ABILITY OR FITNESS FOR A P ARTICULAR PURPOSE, WHICH EXTEND BEYOND
THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limit actions on how long implied warranties may
last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives
you specific legal rights and you may also have other rights which vary from jurisdiction to
jurisdiction.
2
Original installation and operating instructions.
Caution
Note
CONTENTS
1.Product introduction
1.1 Symbols used in this document
1.2 Introduction
1.3 Delivery and handling
1.4 Applications
1.5 Features and benefits
1.6 How the system functions
1.7 System diagram
1.8 Quick selection guide
1.9 Overview of built-in protections
2.Operating conditions
3.Installation
3.1 Quick installation guide
3.2 Mechanical installation
3.3 Electrical installation
3.4 Installation of pressure sensor
3.5 Installation of diaphragm pressure tank
3.6 Installation of pressure relief valve
3.7 Liquid filling and BMQE pump venting
3.8 BMQE pumps connected in parallel
4.Operation
4.1 Starting the BMQE pump for the first time
4.2 Generator operation
4.3 BMQE controller operating functions
4.4 Built-in protections
4.5 Built-in dry-running protection
5.Position of LED’s
6.Maintenance and service
6.1 Storage
6.2 Frost protection
6.3 BMQE controller service
6.4 Optional R100 interface
7.Technical data
7.1 Technical data for BMQE pump
7.2 Technical data for BMQE controller
8.Troubleshooting
8.1 Fault finding chart - BMQE pump
8.2 Fault finding chart - BMQE controller
8.3 Instruments not allowed
8.4 Checking of motor and cable
8.5 Factory settings
8.6 Pressure sensor voltage chart
9.Disposal
Warnin g
Prior to installation, read these installation and
operating instructions carefully. Installation and
operation must comply with local regulations and
accepted codes of good practice.
Warning
The use of this product requires experience with
and knowledge of the product.
Persons with reduced physical, sensory or mental
capabilities must not use this product, unless
they are under supervision or have been
instructed in the use of the product by a person
responsible for their safety.
Children must not use or play with this product.
Page
10
10
10
10
10
10
11
12
12
13
14
14
14
14
14
15
15
15
16
16
17
19
20
20
21
22
1. Product introduction
This manual describes the installation and operation of the
Grundfos BMQE Constant Pressure System.
1.1 Symbols used in this document
3
3
3
3
3
4
4
4
5
5
5
6
6
1.2 Introduction
8
8
The Grundfos BMQE Constant Pressure System is a complete
9
pressure boosting system that includes pump, controller, tank,
9
mounting brackets, and pressure sensor. High-quality
construction and rugged design ensure low-maintenance and
trouble free operation. The system is simple to install and simple
to operate as it automatically balances water surges and
equalizes flow and pressure according to consumption. In other
words, the system maintains a constant water pressure in spite of
varying water consumption; it provides constant water pressure
even while multiple taps are on. The pressure is registered by
means of the pressure sensor and transmitted to the controller.
The controller adjusts the BMQE pump performance accordingly.
1.3 Delivery and handling
The shipping carton your pump came in is specially designed
around your pump during production to prevent damage. As a
precaution, the pump should remain in the carton until you are
ready to install it. The components are ready for installation.
Examine the pump for any damage that may have occurred
during shipping. Examine any other parts of the shipment as well
for any visible damage.
1.4 Applications
The Grundfos BMQE Constant Pressure System is intended for
large residential & light commercial pressure boosting
applications such as:
• medical offices
• restaurants
•homes
• condos
• irrigation
• grocery
• other boosting applications.
1.4.1 Pumped liquids
The BMQE must not be used for the transfer of flammable liquids
such as diesel oil, petrol or similar liquids. The BMQE is suitable
for pumping thin, clean, non-aggressive, non-explosive liquids,
not containing solid particles or fibers. The BMQE is suitable for
pressure boosting clean, cool, potable water. The liquid must not
attack the pump materials chemically or mechanically.
The temperature of the pumped liquid must not exceed
+ 95 °F (+ 35 °C).
Warnin g
If these safety instructions are not observed,
it may result in personal injury!
If these safety instructions are not observed,
it may result in malfunction or damage to the
equipment!
Notes or instructions that make the job easier
and ensure safe operation.
3
1.5 Features and benefits
Pressure
Flow
A
Stop
+7 PSI
Start
-7 PSI
Controlling
±3 PSI
Dynamic
variations
±7 PSI
GPM0.8
A = Pressure setting
The BMQE Constant Pressure System features:
• Quick and easy installation: ready-to-use system requiring
minimum space
• high user convenience: constant pressure regardless of water
consumption
• easily adjustable pressure level: push button control
• continuous control and monitoring of pump operatio
• integrated dry-running protection
• integrated overload protection
• integrated protection against over voltage and under voltage
• soft start system.
1.6 How the system functions
When a tap is opened, the pressure in the tank will start to drop.
The system maintains a constant pressure within the maximum
pump performance in spite of varying water consumption.
The pressure is registered by means of the pressure sensor,
which transmits a signal to the controller. The controller adjusts
the pump performance accordingly to maintain constant pressure
by changing the pump speed.
At low flow the pressure will drop slowly. When the pressure in
the tank is 7 psi below the setpoint, the pump will start. When the
pressure is 7 psi above the setpoint, the pump will stop.
Even though the BMQE controller is controlling the pressure
within + / - 3 psi, larger pressure variations may occur in the
system. If the consumption is suddenly changed, e.g. if a tap is
opened, the water must start flowing before the pressure can be
made constant again.
Such dynamic variations depend on the pipework, but typically
they will lie between 7 and 14 psi. If the desired consumption is
higher than the quantity the pump is able to deliver at the desired
pressure, the pressure follows the pump curve (illustrated at the
far right of fig. 1).
At large flow rates, the pressure will drop quickly and the pump
will start immediately and maintain constant pressure. When the
system is running, the BMQE controller makes small adjustments
to the pressure to detect whether there is consumption. If there is
none, the pump will simply refill the tank and stop after a few
seconds.
• The pressure required is 70 psi system pressure at the taps in the building.
• The normal minimum inlet pressure (e.g. city pressure) is 20 psi.
• The additional boost required is 50 psi at 15 gpm (3.4 m
• Select a 15 BMQE 05A-110.
3
/h).
3
/h).
Additional (boost)
pressure required
[psi]
90
80
70
60
50
40
30
20
10
510152025303539
15 BMQE 07B-180
22 BMQE 05B-120
15 BMQE 05A-110
1.9 Overview of built-in protections
1.9.1 Run-dry protection
The BMQE pumps are protected against dry-running. In case
of dry-run, the BMQE will stop after an accumulated time of
5 seconds thus preventing a burnout of the motor. After a
dry-running alarm, the pump restarts automatically after
5 minutes.
1.9.2 Overload p ro tect io n
Exposure of the BMQE pump to heavy load causes the current
consumption to rise. The motor will automatically compensate for
this by reducing the speed. If the speed drops to 30 % of the
rated speed, the motor will be cut out. If the rotor is being
prevented from rotating this will automatically be detected and the
power supply cutout. Consequently, no extra motor protection is
required.
1.9.3 Over-voltage and under-voltage protection
Over voltage and under voltage may occur if the voltage su pply is
unstable. The integrated protection of the BMQE motor protects
the motor if the voltage falls outside the permissible voltage
range.
• With a rated voltage of 200 - 240 V, 60 Hz, the pump will be
cut out if voltage falls below 150 V or rises above 280 V.
• With a rated voltage of 110 - 1 15 V, 60 Hz, the pump will b e cut
out if voltage falls below 75 V or rises above 150 V.
The motor is automatically cut in when the voltage is again within
the permissible voltage range. Therefore, no extra voltage
protection relay is required.
Flow required [gpm]
22 BMQE 10C-190
30 BMQE 10C-130
22 BMQE 05A-8030 BMQE 05B-90
2. Operating conditions
Liquid temperature
The temperature of the pumped liquid must not exceed
+ 95 °F (+ 35 °C).
Supply voltage
1 x 200-240 V –10 % / +6 %, 60 Hz
1 x 110-115 V –10 % / +6 %, 60 Hz
Starting current
The motor starting current is equal to the highest value stated
on the BMQE nameplate.
5
3. Installation
Note
3.1 Quick installation guide
For more detailed instructions, skip this section and go to section
3.2 Mechanical installation.
Warnin g
Before starting work on the BMQE controller or
BMQE pump, make sure that the electricity
supply has been switched OFF and that it cannot
be accidentally switched on.
The BMQE must be grounded. The BMQE
controller must be connected in accordance with
the local rules and regulations.
.
When the BMQE pump is installed horizontally,
the air relief vent must be in the 12 o’clock
position.
When the BMPQE pump is installed vertically, the
air vent must be at the top of the unit.
13.Verify that the BMQE pump is operating. If n ot, refer t o section
8. Troubleshooting.
15.Optional: lock the buttons.
7
3.2 Mechanical installation
Note
3.2.1 Pre-installation checks
Before installation, the following checks should be made:
1. Confirm pump type
Check that the pump type stated on the nameplate fitted to the
module sleeve corresponds to your order.
2. Check electricity supply
The motor voltage and frequency details stated on the nameplate
should be compared with the actual electricity supply available.
3.2.2 Location of installation
The sound pressure level of the BMQE is <74 db[A] at a distance
of 3 feet (1 meter). It is recommended by Grundfos that the pump
be installed with sound and vibration dampening equipment such
as flexible piping adapters and anti-vibration mounting.
Like most mechanical equipment, this system
can create noises and vibrations. Grundfos
recommends that the BMQE pump should not be
mounted in or adjacent to living quarters.
The pump should not be mounted in or adjacent to living quarters.
The pump can also be wrapped with sound proofing insulation to
reduce noise.
3.2.3 Positioning the pump
The GRUNDFOS BMQE pump is supplied with a built-in
non-return valve. An arrow on the BMQE sleeve shows the
direction of liquid flow through the pump (fig. 3).
The BMQE is suitable for both vertical and horizontal installation;
however, the discharg e port should never fall below the horizont al
plane. See fig. 4.
The BMQE must be installed with the air relief vent in the 12
o’clock position when installed horizontally and when installed in
the vertical position, the air vent must be at the top of the unit.
Fig. 3 Arrow showing direction of liqu id flo w throug h pump
In situations where multiple BMQE pump power cables are run
parallel in wiring trays or conduit and less than 12 inches apart,
the possibility for undesired communication between units exists.
When this occurs, intermittent or continuous NO CONTACT is
typically seen. Other unexpected errors may also be seen.
There are two ways to eliminate the possibility of cross
communication:
1. Physical separation of the cables – maintain a minimum of 12
inches between pump power cables, and never place more
than one cable in a conduit.
2. Use shielded cable – the use of shielded cable prevents cross
communication between parallel cables and allows sharing of
conduit and cable trays. Tie the cable shield to ground only at
the BMQE controller panel.
Warnin g
The electrical connection should be carried out
by an authorized electrician in accordance with
local regulations.
Warnin g
Before starting work on the BMQE controller or
BMQE pump, make sure that the electricity
supply has been switched OFF and that it cannot
be accidentally switched on.
The BMQE must be grounded. The BMQE
controller must be connected in accordance with
the local rules and regulations.
TM04 9411 4110TM04 13 75
Warnin g
IMPORTANT: The ON/OFF button on the BMQE
controller must not
be used as a safety switch
when installing and servicing the pump.
Fig. 4 Installation positions
3.2.4 Power line communication
The communication between the BMQE controller and the BMQE
pump is via the power supply cable. This communication principle
is known as power line communication.
Using this principle means that no additional cables to the pump
are required. The communication of data is effected by means of
a high-frequency signal transmitted to the power supply cable.
8
Warnin g
The BMQE must never be connected to a
capacitor or to another type of control box than
BMQE controller.
The BMQE must never be connected to an
external frequency converter.
Warnin g
Reduced risk of electric shock during operation
of the BMQE system requires the provision of
acceptable grounding. If the means of connection
to the supply connected box is other than
grounded metal conduit, ground the pump back
to the service by connecting a copper conductor,
at least the size of the circuit supplying the
pump.
Rain-tight or wet location hubs that comply with the requirements
in the standard for Fittings for Conduit and Outlet Boxes, UL514B,
are to be used. Suitable devices for BMQE controller are rated
with enclosure type 3, 3R, 3S, 4, 4X, 6 or 6P.