Grunbeck softliQ:SD Series, softliQ:SD18, softliQ:SD21, softliQ:SD23, softliQ:MD Series Operation Manual

...
We understand water.
Water softener | softliQ:SD
Operation manual
Copyright The manufacturer reserves the copyright to this operation manual. Without the written consent of Grünbeck Wasseraufbereitung GmbH, no part of this manual may be reproduced in any way, nor may any part be processed, duplicated or distributed using electronic systems. Non-compliance of the aforementioned requirements shall be subject to compensation.
Subject to technical modifications. © by Grünbeck Wasseraufbereitung GmbH
Translation of the original operation manual Edition of the operation manual: May 2019 Order-no.: TD3-BS001en_014
Table of contents
3 | 80
BA_TD3-BS001en_014_softliQ
-SD

Table of contents

Table of contents ................................................................ 3
1 About this instruction ............................................... 4
1.1 Other applicable documents ...................................... 4
1.2 Target group .............................................................. 4
1.3 Storage of the documents .......................................... 4
1.4 Symbols used ............................................................ 4
1.5 Typographical conventions ........................................ 5
1.6 Validity of the instruction ............................................ 5
1.7 Type plate .................................................................. 6
2 Safety ......................................................................... 7
2.1 Safety measures ........................................................ 7
2.2 Technical safety instructions ...................................... 8
2.3 Regulations ................................................................ 8
2.4 Responsibilities of the specialist installer ................... 8
2.5 Responsibilities of the owner / user ........................... 9
2.6 Permitted regenerant ................................................. 9
3 Product description ................................................ 10
3.1 Intended use ............................................................ 10
3.2 Product components ................................................ 11
3.3 Functional description .............................................. 12
3.4 Function ................................................................... 13
3.5 Additional equipment softliQ:SD21 and
softliQ:SD23 ............................................................. 14
3.6 Product registration .................................................. 14
3.7 Accessories ............................................................. 15
3.8 Inputs and outputs of the control unit ....................... 17
4 Installation ............................................................... 19
4.1 Requirements for the installation site ....................... 20
4.2 Check the scope of supply ....................................... 21
4.3 Installing the product ................................................ 22
5 Start-up .................................................................... 25
5.1 How to start up the product ...................................... 25
5.2 Handing over the product to the owner / user .......... 34
6 Operation ................................................................. 35
6.1 Touch display ........................................................... 35
6.2 Menu structure ......................................................... 38
6.3 Connection to Grünbeck Cloud ................................ 41
6.4 Refilling salt tablets .................................................. 46
6.5 Starting a manual regeneration ............................... 47
6.6 Determining and entering the water hardness ......... 47
6.7 Select regeneration time .......................................... 49
6.8 Set the blending valve ..............................................49
6.9 Installer level (code 005) ..........................................50
6.10 Sending an email if there is a malfunction ................52
7 Cleaning, inspection, maintenance ........................53
7.1 Cleaning ...................................................................53
7.2 Inspection .................................................................54
7.3 Intervals ....................................................................54
7.4 Maintenance .............................................................55
7.5 Consumables ............................................................57
7.6 Spare parts ...............................................................57
7.7 Wearing parts ...........................................................58
8 Malfunction ...............................................................59
8.1 Display messages ....................................................59
8.2 Other observations ...................................................63
9 Shut-down and restart .............................................64
9.1 Shut-down ................................................................64
9.2 Restart ......................................................................64
10 Dismantling and disposal .......................................65
10.1 Dismantling ...............................................................65
10.2 Disposal ....................................................................66
11 Technical specifications .........................................67
12 Other information .....................................................69
12.1 Sodium content in the water .....................................69
12.2 Hardness ranges ......................................................69
13 Operation log ............................................................70
1st maintenance ................................................................71
2nd maintenance ...............................................................72
3rd maintenance ................................................................73
4th maintenance ................................................................74
5th maintenance ................................................................75
6th maintenance ................................................................76
EC Declaration of Conformity ..........................................77
Index ...................................................................................78
About this instruction
BA_TD3-BS001en_014_softliQ-SD
This symbol identifies instructions that you must comply with for your personal safety as well as to avoid damage to property.
This symbol identifies information and instructions that you must comply with in order to avoid damage to property
This symbol identifies important information about the product or its handling.
This symbol identifies work that is only allowed to be carried out by a specialist installer. In Germany, the installation company must be registered in an installation directory of a water supply company acc. to §12(2) AVB Wasser V (German Ordinance on General Conditions for the Supply of Water).
This symbol designates tasks that may only be performed by Grünbeck's technical service / authorised service company or by specialist installers trained by Grünbeck.
This symbol identifies work that may only be carried out by qualified electrical experts according to the VDE guidelines or according to the guidelines of similar local institutions.

1 About this instruction

1.1 Other applicable documents

The following documents also apply in the case of the softliQ:SD:
For Grünbeck's technical service / authorised service company: Technical service manual of water softener softliQ:SD, order-no.: TD4-BS001
The manuals of all accessories used.

1.2 Target group

The intended audience for this manual is comprised of specialist installers and owner-users.

1.3 Storage of the documents

Keep this instruction and all other applicable documents, so that they are available when needed.

1.4 Symbols used

4 | 80
About this instruction
5 | 80
BA_TD3-BS001en_014_softliQ
-SD

1.5 Typographical conventions

The following typographical conventions are used in this instruction:
Description
Depiction
Handling instruction One-step or chronological sequence of steps does not matter
Action
Handling instruction multi-step and chronological sequence of action steps important
1. First action a first step b second step
2. Second action
Result after a handling instruction
» Result
Lists
List item
List sub-item
Menu paths
Status level>Menu level>Submenu
Display texts
Display text
Operating elements
Button / key

1.6 Validity of the instruction

This instruction applies to the following products:
Water softener softliQ:SD18
water softener softliQ:SD21
water softener softliQ:SD23
About this instruction
6 | 80
BA_TD3-BS001en_014_softliQ
-SD

1.7 Type plate

The type plate is located under the lid of the brine tank.
Please specify the data shown on the type plate in order to speed up the processing of your enquiries or orders.
Enter the necessary information in the table below to have it readily available
whenever necessary.
Item
Designation
Item
Designation
1
Observe operation manual
2
Disposal information
3
SVGW test mark
4
DVGW test mark
5
CE mark
6
Nominal pressure
7
Operating pressure
8
Ambient temperature
9
Water temperature
10
Rated voltage range / frequency
11
Rated load
12
Protection / protection class
13
Product designation
14
QR code
15
Data matrix code
16
Order no.
17
Serial no.

Overview

Product designation: Water softener softliQ:SD___________
Order no.: 189_____________
Serial no.: BS______________
Safety
7 | 80
BA_TD3-BS001en_014_softliQ
-SD

2 Safety

WARNING: Contamination of drinking water due to incorrect handling.
Risk of infectious diseases. Have the installation, commissioning and annual maintenance carried out by
specialist installers.

2.1 Safety measures

Carefully read this manual before operating your product.
Only operate the product if all components are installed properly.
Only have persons working on your product who have read and understood
this manual and that are qualified to do such work on account of their vocational training.
Keep your product permanently connected to the power and water supply.
Safety devices must never be removed, bridged or otherwise tampered with.
Do not operate any products which have a damaged power supply cable. This can
lead to injuries due to electric shock. Have damaged power supply cables replaced without delay.
Mains cables may only be replaced by the manufacturer or by authorised personnel.
Observe the maintenance intervals (refer to chapter 7). Failure to comply can result in microbiological contamination of your drinking water installation.
Children are not allowed to play with the product.
This product can be used by children over 8 years of age and persons with limited
abilities or lack of experience if they are supervised or instructed in the safe use of the product and understand the resulting hazards.
Cleaning and maintenance must not be carried out by children.
Safety
8 | 80
BA_TD3-BS001en_014_softliQ
-SD

2.2 Technical safety instructions

This manual contains instructions that you must comply with for your personal safety as well as to avoid damage to property. The information and instructions are highlighted by a warning triangle and have the following structure:
CAUTION: Type and source of danger.
Possible consequences Measures for avoidance
The following signal words are defined depending on the degree of danger, and can be used in this manual:
DANGER means that death or serious injury will result.
WARNING means that death or serious injury can result.
CAUTION means that minor bodily injuries can occur.
NOTE (without warning triangle) means that property damage can occur.

2.3 Regulations

Comply with the following regulations and directives, amongst others, during installation, start-up and maintenance:
Statutory regulations on environmental protection
Provisions of the employers' liability insurance companies
DIN EN 806 Specifications for installations inside buildings conveying water for
human consumption
VDI 6023 Part 5 – 7 Specifications for installations inside buildings conveying water for human consumption

2.4 Responsibilities of the specialist installer

Comply with the following instructions to ensure the proper and safe functioning of the product:
Only perform activities described in this manual.
Perform all activities in accordance with all applicable standards and regulations.
Brief the owner / user on the function and operation of the product.
Advise the owner / user of the maintenance of the product.
Instruct the owner-user about possible dangers that can arise during operation of
the product.
Fill in the operation log (refer to chapter 13)
Safety
9 | 80
BA_TD3-BS001en_014_softliQ
-SD

2.5 Responsibilities of the owner / user

Comply with the following instructions to ensure the proper and safe functioning of the product:
Arrange for a specialist installer to carry out installation, start-up and maintenance.
Have the product explained to you by the specialist installer.
Only perform activities described in this manual.
Do not carry out any activities that are explicitly marked for a specialist installer.
Only use this product as intended.
Make sure that the required inspection and maintenance work is carried out.
Keep this instruction.

2.6 Permitted regenerant

softliQ water softeners are only allowed to be operated with the following regeneration agent:
Salt tablets according to DIN EN 973 type A
Product description
10 | 80
BA_TD3-BS001en_014_softliQ
-SD

3 Product description

3.1 Intended use

The softliQ water softener may only and exclusively be used for the softening and partial softening of cold drinking water.
The softliQ water softener protects water pipes and connected water-carrying systems from scaling or from malfunctions and damage caused by scaling.
The water softener softliQ:SD18 is designed for the continuous supply of 1 to 2 family homes (max. 4 persons) with soft water.
The water softener softliQ:SD21 is designed for the continuous supply of 1 to 4 family homes (max. 9 persons) with soft water.
The water softener softliQ:SD23 is designed for the continuous supply of 1 to 5 family homes (max. 12 persons) with soft water.
Product description
11 | 80
BA_TD3-BS001en_014_softliQ
-SD

3.2 Product components

Item
Description
Item
Description
1
Connection block
2
Shut-off valve for raw water
3
Blending valve
4
Locking screw
5
Shut-off valve for soft water
6
Control (display)
7
Brine tank lid
8
Salt supply display sensor*
9
Illuminated LED ring*
10
Cover for connections (customer interface)*
11
Water connection pipes
12
Housing of technical equipment, upper part
13
Housing of technical equipment, lower part
14
Brine tank
15
Brine valve
16
Sieve bottom
17
Exchanger tank
18
Control valve
19
Water test kit "total hardness“
20
Water sensor*
* Not with softliQ:SD18
Product description
12 | 80
BA_TD3-BS001en_014_softliQ
-SD

3.3 Functional description

3.3.1 Ion exchange process

The softliQ water softener works according to the ion exchange process. The exchange of calcium and magnesium ions for sodium ions causes the water to become soft.
Figure
Explanation
The exchanger contains ion exchanger resin in the form of small resin beads.
Sodium ions adhere to each resin bead.
Hard water containing lots of calcium and magnesium ions flows through the exchanger.
The ion exchanger resin absorbs calcium and magnesium ions from the water in exchange for sodium ions.
This reaction is called ion exchange. The calcium and magnesium ions are retained in the exchanger. Soft water without calcium and magnesium ions, but containing sodium
ions, leaves the exchanger. This process continues until no more sodium ions are available. The ion
exchanger resin is exhausted.
The exchange can be reversed if a large amount of sodium ions is added. The exchanger is rinsed with brine (water containing salt). By their sheer number, sodium ions displace calcium and magnesium
ions on the ion exchanger resin. This water containing calcium and magnesium ions is discharged to
the drain. The initial condition is restored. The ion exchanger resin is regenerated, and thus ready for operation.
Sodium ion Calcium ion Magnesium ion
Your dishwasher works according to the ion exchange process, too.
Product description
13 | 80
BA_TD3-BS001en_014_softliQ
-SD

3.3.2 Intelligence of the water softener softliQ:SD

Based on the consumption values of the past 4 weeks, the system capacity is automatically adjusted to the individual water consumption of the owner / user. SoftliQ water softeners offer several selection options (= modes of operation). The factory setting is Comfort. In case of considerable fluctuations in the water consumption, however, it is possible to switch to the Power mode in the Settings. With low water consumption, Eco offers an energy and resource-saving option. The currently setting is displayed in Information menu 1.
A regeneration is triggered daily, if at least 50 % of the current system capacity is used up. The point of regeneration automatically is placed in a time period where usually no water is consumed. The point of regeneration can also be set at a fixed time. Should water be required during the regeneration process, non-softened water is available.
During each regeneration, only the used-up system capacity is regenerated. and only as much salt is used as necessary. No later than after 4 days without regeneration, the system releases a complete regeneration, as required by DIN standard 19636-100, for hygienic reasons.
The intelligence of the softliQ water softener allows for an efficient operation at the lowest salt and power consumption possible.

3.4 Function

The water softener softliQ:SD offers 5 selections:
Comfort (factory-setting)
Optimum use of resources and system output.
Eco
Minimum use of resources in case of normal consumption.
Power
Maximum performance for highest demands.
Individual
To enter your individual user profile.
Fix
To enter a permanently fixed capacity figure without looking at the past and adjusting the capacity figure.
Product description
14 | 80
BA_TD3-BS001en_014_softliQ
-SD

3.5 Additional equipment softliQ:SD21 and softliQ:SD23

3.5.1 Salt supply display

Once per regeneration, a light sensor briefly checks the filling level of the regeneration salt. If the filling level is below the minimum, the control unit provides feedback in the form of a warning message. This is shown by a yellow symbol in the control unit. The control unit of the softliQ:SD21 and softliQ:SD23 calculates how many days the salt supply is expected to last, and shows this value in days in the warning message.
The days the salt supply is expected to last are calculated based on the water consumption of the past days. In case of fluctuating water consumption, the indicated range of the salt supply also fluctuates.

3.5.2 Illuminated LED ring

The illuminated LED ring is used as a visual signal in water treatment, operation and fault. In the standard setting, the illuminated LED ring behaves as follows:
Is illuminated during water treatment
Is illuminated during operation of the control unit
Intermittent flashing in case malfunctions do occur
Intermittent flashing in case of pre-alarm salt supply
The illuminated LED ring can be set to continuous illumination or be deactivated completely (refer to chapter 6.2).

3.5.3 Water sensor

The water sensor detects water at the installation location of the softliQ, provides information via the softliQ control or the Grünbeck myProduct app, and triggers an audio signal (if activated).

3.6 Product registration

You have the following options to register your product:
Registration on Grünbeck's website (www.gruenbeck.com).
Registration using the Grünbeck myProduct app (refer to chapter 6.3).
Registration via the enclosed postcard.
Registration extends your warranty by 1 year.
Product description
15 | 80
BA_TD3-BS001en_014_softliQ
-SD

3.7 Accessories

You can retrofit accessories to your product. Please contact your local Grünbeck representative or Grünbeck’s headquarters in Hoechstaedt for details.
Image
Product
Order no.
Dosing computer EXADOS EK 6
115 100
Dosing computer EXADOS ES 6
115 200
Electronically controlled dosing technology for corrosion protection or to stabilise the total hardness.
Safety device protectliQ:A20
126 400
Product for protection against water damage in one- and two-family homes. For other sizes, please inquire.
Regeneration water delivery pump
188 800
To discharge the regeneration water into drain pipes located at a higher level. Only suitable for softliQ:SD23 and softliQ:MD.
Drain connection DN 50
188 875
For professional installation acc. to DIN EN 1717. Included in scope of supply of softliQ:SD23.
Extension kit for connection hoses
187 860e
To extend the hose to 1.6 m.
Product description
16 | 80
BA_TD3-BS001en_014_softliQ
-SD
Image
Product
Order no.
Supplementary blending valve
187 870
To generate a second blending hardness (e.g. separate pipe to the kitchen, technical applications, etc.).
Additional soft water outlet
187 875
To easily branch off a 0 °dH (0 °f, 0 mol/m³) pipe (e.g. for a separate pipe for technical applications, etc.).
Hall cable with clip and pulse division softliQ-EXADOS GSX, VGX
119 645
Hall cable with clip and pulse division softliQ-EXADOS VFR, VGR
119 642
For connecting to an EXADOS dosing computer provided by the client.
softliQ insulation set
188 870
For professional insulation of the connection equipment. Included in scope of supply of softliQ:SD23.
Product description
17 | 80
BA_TD3-BS001en_014_softliQ
-SD

3.8 Inputs and outputs of the control unit

The control unit features voltage-free inputs and outputs. The functions are described in chapter 6.9.

3.8.1 Data circuit board (only with softliQ:SD21 and softliQ:SD23)

Item
Description
Item
Description
1
LAN connection
2
iQ-Comfort 1 (for networking Grünbeck products)
3
iQ-Comfort 2 (for networking Grünbeck products)
4
Water sensor (digital input)
If another function is required for the digital input, the water sensor must be disconnected. Cables LiYY 2x0.5 mm² or comparable should be used as connecting line. A larger line
cross-section is unsuitable.
Water sensor pin assignment (digital input):
Terminal top + terminal middle = water sensor
Terminal bottom + terminal middle = regeneration triggering or regeneration lock
No voltage signals are allowed to be applied to any of the 3 terminals.
Product description
18 | 80
BA_TD3-BS001en_014_softliQ
-SD

3.8.2 Power circuit board (only with softliQ:SD23)

WARNING: Fatal shock hazard.
Contact with live parts may result in injury. Make sure that the product is in a voltage-free state (pull out the mains plug)
before removing the protection against accidental contact.
The power circuit board is located under the protection against accidental contact.
1. Remove the protection against accidental contact to access the power circuit board.
Item
Description
Item
Description
1
Protection against contact
2
Fault signal contact (upper two terminals) max. 230 V/max. 1 A (factory setting N.C.)
3
Programmable output (lower two terminals) e.g. connection of the regeneration water delivery pump max. 230 V/max. 1 A (factory setting regeneration water delivery pump)
2. Use the following connection cables for connection to the fault alarm contact or the programmable output:
Flexible cables of quality H05xx F 2x0.75 mm² or comparable, because consumers operated with mains voltage may be connected. A larger line cross-section is unsuitable.
3. After the connection has been made, attach the protection against accidental contact.
Installation
19 | 80
BA_TD3-BS001en_014_softliQ
-SD

4 Installation

The installation of a water softener represents a major intervention into the drinking water system and only a specialist installer should install these systems.
Item
Description
Item
Description
1
Safety device protectliQ
2
Drinking water filter pureliQ:KD
3
Garden water pipe
4
Water withdrawal point
5
EXADOS dosing computer
6
softliQ insulation set
7
Drain connection DN 50 acc. to DIN EN 1717
The connection block can be installed horizontally or vertically in the drinking water system. No dosing can be connected in a vertical installation.
Installation
20 | 80
BA_TD3-BS001en_014_softliQ
-SD

4.1 Requirements for the installation site

Observe local installation directives, general guidelines and technical specifications.
The installation site must be frost-proof and ensure the product is protected from chemicals, dyes, solvents and vapours.
If the softened water is intended for human consumption in the sense of the German Drinking Water Ordinance, the ambient temperature must not exceed 25 °C. For applications that are purely technical, the ambient temperature must not exceed 40 °C.
Always install a drinking water filter and, if required, a pressure reducer (e.g. fine filter pureliQ:KD) upstream of the product.
A shock-proof socket is required within a distance of approx. 1.2 m of the system. The socket requires a permanent power supply and must not be connected to light switches, emergency heating switches or similar devices.
A drain connection (DN 50) must be available to discharge the regeneration water.
There must be a water withdrawal point near the product.
A floor drain suitable for the system size must be available at the installation site
or a protection device e.g. protectliQ or a protection device with water stop of the same quality must be installed.
Ensure that lifting systems are resistant to salt water or use our regeneration water delivery pump (refer to chapter 3.7).
Installation
21 | 80
BA_TD3-BS001en_014_softliQ
-SD

4.2 Check the scope of supply

Item
Description
Item
Description
1
Water softener completely pre-assembled
2
2 Connection hoses
3
Water test kit "total hardness“
4
Operation manual
5
Connection block incl.
- 2 inserts
- 2 union nuts
- 2 gaskets
Check the scope of supply for completeness and damage.
Installation
22 | 80
BA_TD3-BS001en_014_softliQ
-SD

4.3 Installing the product

WARNING: Danger of contaminated drinking water due to stagnation.
Risk of infectious diseases. In accordance with VDI 6023, do not connect the product to the drinking water
installation until directly before start-up.
Only open the two valves on the connection block during start-up. Only carry out the leakage test during start-up.

4.3.1 Installing connection block

1. Install the water meter screw connection into the pipe.
2. Check the flow direction given on site.
The direction of flow is indicated by an arrow on the connection block.
3. Make sure that the strainer insert is inserted on the inlet side.
4. Mount the connection block by tightening the union nuts without applying tension.
» The connection block is installed.
Installation
23 | 80
BA_TD3-BS001en_014_softliQ
-SD

4.3.2 Installing the connection hoses

1. Unscrew both the screws at the side on the upper part of the housing for technical
equipment.
2. Remove the upper part of the housing for technical equipment.
3. Observe the flow direction indicated by arrows on the connection block and on the
control valve.
4. Mount the connection hoses with a suitable tool.
Installation
24 | 80
BA_TD3-BS001en_014_softliQ
-SD

4.3.3 Establish waste water connection as per DIN EN 1717

The duct connection facilitates DIN-compliant connection (refer to chapter 3.7).
NOTE: Waste water backing up due to kinked hoses.
Risk of water damage. Run the hoses to the drain with a downward slope and without kinks and bends.
1. Shorten the flushing water hose (diameter 12 mm) to the required length.
2. Fasten the flushing water hose (regeneration water flows out under pressure).
3. Shorten the overflow hose (diameter 16 mm) to the required length.
4. Run the overflow hose to the drain with a downward slope.
5. Make sure there is a free outlet to the drain in accordance with the standard.
6. Fasten the overflow hose.
If the flow pressure is at least 3 bar, the flushing water hose can be routed up to 2 m above the floor. It is then not possible to connect the overflow hose.
» This completes the installation.
Protect the product from contamination until it is started up.
Slide the protective sleeve from the packaging over the product.
Start-up
25 | 80
BA_TD3-BS001en_014_softliQ
-SD

5 Start-up

5.1 How to start up the product

The start-up program assists you with starting up the softliQ water softener. You are guided through the start-up procedure step-by-step on the touchscreen display.
Start-up is not fully automatic.
Follow the instructions on the touchscreen display (see chapter 6).
Use the or buttons to navigate through the program.
Press to go to the previous menu level.
With , you confirm the selection and move to the next menu level.

5.1.1 Initial start-up and automatic start of the start-up program

1. Keep salt tablets (refer to chapter 2.6) ready.
2. Plug in the mains plug.
3. Select the desired language – touch the corresponding flag.
4. Select the continent where the system is installed.
5. Select the required hardness unit – if known.
6. Select Start-up START.
» The start-up program starts.
Start-up
26 | 80
BA_TD3-BS001en_014_softliQ
-SD

5.1.2 Program flow of the start-up program

1. Check the correct system connection.
2. Select the drain connection used.
3. Check whether the lines to the drain connection have been laid with a gradient.
4. Place the water sensor flat on the floor.
5. Fill salt tablets into the brine tank (refer to chapter 6.3) – do not fill in water.
Start-up
27 | 80
BA_TD3-BS001en_014_softliQ
-SD
6. Set the time and date.
7. Determine the raw water hardness.
a Contact your water supply company and ask them what the value is or b Measure the value using the supplied water test kit (refer to chapter 6.6).
8. Type in the value for the raw water hardness.
You can change the value at a later time (refer to chapter 6.6).
» After the set value has been confirmed, the automatic positioning of the control
valve starts.
Item
Description
Item
Description
1
Shut-off valve for raw water
2
Blending valve
3
Locking screw (Torx 20 required)
4
Shut-off valve for soft water
5
Dosing connection option
Start-up
28 | 80
BA_TD3-BS001en_014_softliQ
-SD
9. Open the raw water shut-off valve.
10. Open the soft water shut-off valve.
Water flows through the flushing water hose to the drain. This is normal during start-up.
11. Start the ventilation program.
» There is an automatic sequence of 9 program steps.
» This is followed by a 5-step functional check.
Start-up
29 | 80
BA_TD3-BS001en_014_softliQ
-SD
12. Adjust the blending valve as follows.
a Loosen the locking screw on the blending valve. b Close the blending valve completely (turn to the right).
13. Remove cold water at the water draw-off point.
14. Measure the soft water hardness (refer to chapter 6.6).
Start-up
30 | 80
BA_TD3-BS001en_014_softliQ
-SD
15. Move the blending valve to the middle position.
16. Open the water draw-off point completely (let the water run).
17. Remove cold water and measure the soft water hardness.
18. Set the soft water hardness using the blending valve.
Turning to the right (-) reduces the soft water hardness, turning to the left (+) increases it.
Exception for Austria: In Austria, soft and water must have a soft water hardness of min. 8.4 °dH.
Start-up
31 | 80
BA_TD3-BS001en_014_softliQ
-SD
19. Observe the max. sodium concentration (refer to chapter 12.1).
20. Fix the locking screw.
21. Type the set soft water hardness into the display.
22. Close the water withdrawal point.
23. Look and check the connection points for leaks.
Start-up
32 | 80
BA_TD3-BS001en_014_softliQ
-SD
24. Start the test regeneration.
The test regeneration lasts approx. 12 minutes.
Let the test regeneration run.
» The start-up program is finished.
Start-up
33 | 80
BA_TD3-BS001en_014_softliQ
-SD
Check that the water sensor is lying flat on the floor.
Fill in the start-up log (refer to chapter 13).
» This completes the start-up.

5.1.3 Manual start of the start-up program

Menu level>Start-up
Press and hold for 2 seconds.
Follow the instructions on the display.
The sequence of the steps is analogous to the automatic start-up-program.
The start-up program cannot be started while a regeneration is running.
Start-up
34 | 80
BA_TD3-BS001en_014_softliQ
-SD

5.2 Handing over the product to the owner / user

Explain to the owner / user how the water softener works.
Use the manual to brief the owner / user, and answer any questions.
Inform the owner / user about the need for inspections and maintenance.
Inform the owner-user about the influence of water hardness on the dosage rate
of detergents and cleaning agents.
Hand over all documents to the owner / user for storage.
Operation
35 | 80
BA_TD3-BS001en_014_softliQ
-SD

6 Operation

NOTE: The valves of the system are operated electrically.
Water can flow to the drain if there is a power failure during regeneration. If there is a power failure, check your product and shut off the water supply,
if necessary.

6.1 Touch display

6.1.1 Basic display

The touch display is switched off by default.
It is activated by tapping on the touch display.
After a 2-minute pause, the control unit returns to the basic display – the touchscreen
display switches off.
» Parameters that have not been saved are discarded.
Item
Description
Item
Description
1
Menu level (always displayed)
2
Work area / information display (changing symbols)
3
Operating elements (changing symbols)
Operation
36 | 80
BA_TD3-BS001en_014_softliQ
-SD

6.1.2 Menu level

To access a menu, tap the corresponding button. The selected button is displayed in yellow. In the menus, you can start actions or change settings.
Figure
Explanation
Information
This menu offers useful information on the water softener.
Manual regeneration
In this menu, you can manually start a regeneration. (refer to chapter 6.5).
Settings
In this menu, you can adapt your water softener individually (refer to chapter 6.2).
Water hardness
You can enter the current values in this menu (refer to chapter 6.6).
Start-up
In this menu, you can start the automatic start-up program (refer to chapter 5.1).

6.1.3 Information display

Figure
Explanation
Blue symbol
The water softener is working properly. The system capacity declines from the top downwards between 2 regenerations. One bar corresponds to 20 %. The bright bars indicate the available system capacity (= soft water volume still available).
Grey symbol
The water softener is working properly. The water softener regenerates. The bars correspond to the following regeneration steps from the bottom upwards:
Filling brine tank (lowest bar)
Salting
Slow rinse
Backwash
Washing out (uppermost bar)
Operation
37 | 80
BA_TD3-BS001en_014_softliQ
-SD
Figure
Explanation
Current flow rate
The current flow rate is displayed as a numerical value and in the form of a "tachometer" (blue-coloured circle segments). If the nominal flow of the system is exceeded, the circular segments appear in red.
Function
The selected mode of operation appears in a green circle segment.
Perform maintenance
since … days
Yellow symbol
Maintenance due! Notify Grünbeck's technical service / authorised service company.
Leak at the
softliQ installation location
Yellow symbol (not with softliQ:SD18)
Check system location (detection via water sensor) for water leakage and close main valve of domestic water installation if necessary.
days
Yellow symbol (not with softliQ:SD18)
The supply of regeneration salt is running low. The expected time for the salt to last in days is displayed. Refill salt tablets.
Red symbol
The water softener is not working properly.
1. Refill salt tablets.
2. Wait for 10 minutes.
3. Start a manual regeneration (refer to chapter 6.3).
Red symbol
The water softener is not working properly. There is a fault (refer to chapter 8).
Wi-Fi symbol
This is displayed when there is a Wi-Fi connection with a router.
LAN symbol
This is displayed when there is a LAN connection established with a router.
Cloud symbol
Displayed when the connection to the Grünbeck Cloud is established.
Operation
38 | 80
BA_TD3-BS001en_014_softliQ
-SD

6.1.4 Operating elements

Button
Description
Return to the basic display
and
Scroll through the menu level
and
Mark a selection, scroll to the menu items, select settings
Return to the previous menu level, cancel unwanted actions
Confirm display messages and save settings
Buttons that currently have no function are displayed in light green.
To change a value or content, touch the corresponding field. The field becomes white and can be changed.
In some extensive menus, functionally related parameters are grouped together onto tabs under the header. Tap the tab to open the corresponding page. If necessary, you can switch between the tabs with the < or > buttons.

6.2 Menu structure

Values that can be selected or changed are shown in italics.
Menu
Menu items
Values / settings
Information
Basic display
Refer to chapter 6.1.1.
System data
Flow rate Raw water hardness Capacity figure
Counter readings, date and time
Regeneration Soft water volume Perform maintenance in xx days
(if activated) Date and time (display)
Installer contact details
Name Tel. no. Email
Technical service The technical service menu is reserved for
Grünbeck's technical service / authorised service company and specialist installers trained by Grünbeck, and is protected by a code.
Operation
39 | 80
BA_TD3-BS001en_014_softliQ
-SD
Menu
Menu items
Values / settings
Manual regeneration
Press and hold button for 2 seconds to start.
Settings
Language
German English French Spanish Dutch
Danish Italian Russian (planned) Chinese (planned) Taiwanese (planned)
Hardness unit
°dH °f mol/m³
ppm °e
Date, time, time synchronisation
Date, time
Current time Current date
Current continent Current time zone
Time synchronisation
Sw.-over DST to ST NTP synchronisation URL NTP server
Cloud connection, Wi-Fi / LAN connection, network status
Cloud connection
Allow connection to Grünbeck Cloud Linking with Grünbeck Cloud user account URL Cloud URL certificate
Wi-Fi / LAN connection
Network type router connection Automatic IP address (DHCP) Automatic WLAN connection (WPS) Wi-Fi search Found Wi-Fi networks Wi-Fi password
Network status
Parameter, value (display only)
Regeneration time
Automatic
Fixed
Function
Eco Comfort Power
Individual Fixed
Display, audio signal, illuminated LED ring
Display - Display in standby
Deactivated
Activated
Audio signal – behaviour in case of malfunctions
Deactivated
Activated
Operation
40 | 80
BA_TD3-BS001en_014_softliQ
-SD
Menu
Menu items
Values / settings
Audio signal release from … to …
Illuminated LED ring – function setting (SD21 and SD23)
Water treatment + operation + malfunction Operation + malfunction Malfunction Permanent light Deactivated
Illuminated LED ring – Illuminated LED ring flashes on signal
Deactivated
Activated
Illuminated LED ring Brightness
…%
Updates and profiles, manual update
Software update
Automatic
Manual
Save settings profile
no / yes The parameter settings are saved here as a "Private" profile in the Grünbeck Cloud.
Load settings profile
Private profile
Installer profile
Load history stored in Cloud
Start
Manual update
Software update Press and hold button for 2 seconds to check for updates.
Reset factory settings
Start
Device info
Software version / hardware version / serial number control unit / maintenance interval [d]
Water hardness
Setting the water hardness
Press and hold button for 2 seconds to start.
Raw water / soft water
Start-up
Start-up Press and hold button for 2 seconds to start.
Operation
41 | 80
BA_TD3-BS001en_014_softliQ
-SD

6.3 Connection to Grünbeck Cloud

It is possible to control your softliQ water softener via a mobile device and to request information.
To do this, the Grünbeck myProduct app must be installed on your mobile device. The connection between your water softener and the mobile device does not work directly,
but via the Grünbeck Cloud.
The connection between the Grünbeck myProduct app and the softliQ control system is made in the following way:
Item
Designation
Item
Designation
1
Grünbeck product
2
Router
3
Grünbeck Cloud
4
Mobile device
The following steps are necessary:
Install Grünbeck myProduct app on a mobile device
Allow Grünbeck Cloud connection in the control unit
Connect softliQ to router via LAN or Wi-Fi
Setting up a user account in the Grünbeck Cloud
As soon as a user account has been created via the Grünbeck myProduct app and the anonymous data is linked to your user account, the data is personalised as defined by the Data Protection Act.

6.3.1 Installing Grünbeck myProduct app

The Grünbeck myProduct app is the link between your Grünbeck product and your mobile device. You can access your Grünbeck product anywhere.
Download the Grünbeck myProduct app and install it on your mobile device.
Create your personal user account.
The Grünbeck myProduct app supports iOS from version 10.3 onwards and Android starting from version 5.1. Refer to the instructions of your mobile device for information about installing an app.
Operation
42 | 80
BA_TD3-BS001en_014_softliQ
-SD
You can register your product conveniently using the Grünbeck myProduct app.
Call up Registration and Product registration in the device overview of the
Grünbeck myProduct app.
Enter your personal data. » Registration extends your warranty by 1 year.

6.3.2 Allow connection to Grünbeck Cloud

Menu level>Settings>Cloud connection.
1. Select Connection to the Grünbeck Cloud.
» Here you can read the privacy policy.
2. Activate the Allow+accept checkbox.
3. Confirm with ✔.
The URL Cloud parameter must never be changed unless you are instructed to do so, otherwise the softliQ control unit cannot connect to the Grünbeck Cloud.
» The symbol appears in the basic display as soon as the connection to the
Grünbeck Cloud is established.
The following parameters are used for information or adaptation in case of network problems:
Menu items
Settings / remarks
IP address
Normally assigned automatically by the router (= DHCP server).
Can be changed manually, must be different from the other IP addresses already on the network. Must be set in the router to assign this IP address to the softliQ control unit.
Subnet mask
Only editable when working with a fixed IP address.
Default gateway
(indication only)
Data is assigned by the router.
Primary DNS
(indication only)
Data is assigned by the router.
Secondary DNS
(indication only)
Data is assigned by the router.
Status
(indication only)
Connected / not connected
MAC address LAN
(indication only)
MAC address of the network interface of the softliQ control unit.
Operation
43 | 80
BA_TD3-BS001en_014_softliQ
-SD
After the connection to the cloud is allowed and the connection to the router is established, the control unit automatically checks whether a new firmware update is available on the Cloud. This means that the latest security features and functions are always available.
Do not disconnect the power while a firmware download and processing are in
progress (max. 20 minutes).

6.3.3 Establishing connection with router

Connect via LAN (only possible with softliQ:SD21 and SD23)
You need an Ethernet patch cable that is not included in the scope of delivery.
1. Unscrew both the screws at the side on the upper part of the housing for technical
equipment.
2. Remove the upper part of the housing for technical equipment.
3. Open the back cover.
Operation
44 | 80
BA_TD3-BS001en_014_softliQ
-SD
4. Lead the Ethernet patch cable from below to the data interface board.
5. Plug the cable into the LAN connection (refer to chapter 3.8).
6. Create a strain relief by forming a loop.
7. Attach the upper part of the housing of the technical equipment.
The Ethernet patch cable is routed out of the housing with the connection hoses.
8. Fasten the upper part of the housing of technical equipment on the side with the screws.
9. Plug the Ethernet patch cable into the LAN connector of your router.
Menu level>Settings>Wi-Fi/LAN connection
10. Select Network type router connection.
11. Select LAN.
12. Leave the checkbox activated when using DHCP
(should only be changed by an expert).
Operation
45 | 80
BA_TD3-BS001en_014_softliQ
-SD
The parameters Automatic Wi-Fi connection (WPS) and Wi-Fi search are irrelevant for the LAN connection.
» The symbol appears in the basic display as soon as the LAN connection to
the router is established.
Connecting via Wi-Fi
Menu level>Settings>Wi-Fi/LAN connection
1. Select Network type router connection.
2. Select Wi-Fi.
3. Leave the checkbox activated when using DHCP
(should only be changed by an expert).
with WPS function
1. Start the WPS function on your router by holding down the corresponding button
for a few seconds.
2. Select Start on the control unit at Auto Wi-Fi connection. » The Wi-Fi connection is established within approx. 2 minutes.
without WPS function
1. Select Start on the control unit at Wi-Fi search. » After a few seconds, the max. 10 Wi-Fi networks with the best receivable signal
quality appear.
2. Select your Wi-Fi router from this list.
3. Confirm with ✔.
4. Enter your Wi-Fi password.
» The symbol appears in the basic display as soon as the Wi-Fi connection to
the router is established.
As soon as the connection to the Grünbeck Cloud is allowed and a connection to the router is established, the control unit cyclically sends anonymous data to the Grünbeck Cloud.

6.3.4 Linking with Grünbeck Cloud user account

1. Add your softliQ to your user account in the Grünbeck myProduct app with +.
a Scan the data matrix code on the type plate. b Alternatively, enter the serial number.
2. Give your softliQ a device name.
Operation
46 | 80
BA_TD3-BS001en_014_softliQ
-SD
Menu level>Settings>Cloud connection>Grünbeck Cloud-user account
connection
3. Tap Pair.
4. Press and hold the button in the app for 2 seconds.
» Your mobile device and your softliQ are now paired.
Further information on the Grünbeck Cloud and the Grünbeck myProduct app can be found on the Internet at the following address:
https://www.gruenbeck.de/en/become-a-water-expert/faq/

6.4 Refilling salt tablets

The level of salt tablets in the brine tank must always be higher than the water level. The water level is normally approx. 1 cm above the sieve bottom.
1. Open the brine tank lid.
The brine tank lid on the softliQ:SD21 and softliQ:SD23 contains the sensor for the salt supply display. This sensor does not work with laser light, so it is safe for the eyes. The function of the salt supply display is explained in chapter 3.5.
2. Fill in salt tablets.
3. Dispose of the dust-like fine fraction from the bag in the residual waste.
4. Close the brine tank lid.
Operation
47 | 80
BA_TD3-BS001en_014_softliQ
-SD

6.5 Starting a manual regeneration

Menu level>Manual regeneration
A manual regeneration is necessary in the following cases:
The product resumes operation after a longer period of standstill.
After maintenance and repair work has been performed.
After a longer power failure.
Manual regenerations are always complete regenerations with maximum capacity figure.

6.6 Determining and entering the water hardness

The water test kit is designed for the determination of the water hardness in °dH or in °f. The unit mol/m³ (= mmol/l) can be converted from °f.
Item
Description
Item
Description
1
Test tube
2
Titration solution

6.6.1 Taking a water sample

Open the water withdrawal point for cold water fully. A flow rate between 400 l/h and 600 l/h must be attained in order to produce a correct result. You can read the flow rate on the touch-screen display.
1. Open a water withdrawal point for cold water.
a In order to take a raw water sample, use a water withdrawal point for cold water
upstream of the water softener.
b In order to take a soft water sample, use a water withdrawal point for cold water
downstream of the water softener.
2. Let the water flow for at least 30 seconds.
3. Take a water sample with the test tube:
a Fill the test tube up to the °dH mark to determine the water hardness in °dH.
Operation
48 | 80
BA_TD3-BS001en_014_softliQ
-SD
b Fill the test tube up to the marking °f (x 0.1 = mol/m³) in order to determine the
water hardness in °f, mol/m³ or mmol/l.
6.6.2 Determining the water hardness in °dH/°f
1. Add one drop of titration solution (1 drop = 1 °dH = 1 °f).
2. Shake the test tube until the titration solution is mixed with the water.
3. In case of red colouring, repeat steps 1 and 2 and count the drops until the colour
changes to green.
» If the colour changes from red to green, the water hardness has been determined.
The number of drops corresponds to the degree of hardness in °dH or °f. Example:
Test tube filled up to the °dH mark: 6 drops = 6 °dH
Test tube filled up to the °f mark: 6 drops = 6 °f

6.6.3 Determining the water hardness in mol/m³ (mmol/l)

1. Determine the water hardness in °f as described.
2. Divide the value in °f by 10.
The water hardness in °f divided by 10 corresponds to the degree of hardness in mol/m³ (= mmol/l). Example:
6 drops = 6 °f = 0.6 mol/m³ = 0.6 mmol/l
» You get the water hardness in mol/m³.

6.6.4 Entering the water hardness

Menu level>Water hardness
1. Press and hold for 2 seconds.
2. Touch the raw water hardness.
3. Enter the value of the raw water hardness.
4. Confirm with .
The maximum soft water hardness that can be set is approx. 50 % of the raw water hardness present.
Operation
49 | 80
BA_TD3-BS001en_014_softliQ
-SD

6.7 Select regeneration time

Menu level>Settings>Regeneration time
1. Use and to select the desired function.
2. Confirm with .

6.7.1 Setting the time of the fixed regeneration

Select a time at which you have no water consumption for > 1 h, e.g. at 02:00 at night.
1. Select the Regeneration time.
2. Enter the time.
3. Confirm with .

6.8 Set the blending valve

The blending valve may only be set with running water (approx. 400 – 600 l/h, which is about the flow rate of a fully opened water tap).
Recommended soft water hardness: 3 – 6 °dH (5…11 °f)
1. Measure the raw water hardness (refer to chapter 6.6).
2. Move the blending valve to the middle position.
3. Measure the soft water hardness (refer to chapter 6.6).
4. Set the soft water hardness to the required value as follows:
Turn the blending valve to the right reduce the soft water hardness. Turn the blending valve to the left increase the soft water hardness.
Operation
50 | 80
BA_TD3-BS001en_014_softliQ
-SD
5. Enter the set value in the control unit. Menu level>Water hardness
The value is available in the Grünbeck myProduct app.

6.9 Installer level (code 005)

The settings described here may only be made by Grünbeck's technical service / authorised service company.
Menu level>Information>Installer contact data
1. Touch the button .
2. Enter the code using the numerical keypad.
3. Confirm with
» You can change the parameters and values.

The following parameters and values can be changed:

Menu items
Settings / remarks
Wi-Fi access point* Page 1/2
Activate / deactivate
Page 2/2
IP address / SSID / password
Exchanger tank
Page 1/2
Flow [l/h]
Capacity figure [m³ x °dH]
Remaining capacity [m³]
Regeneration step
Page 2/2
Regeneration flow rate [l/h]
Last regeneration [date/time]
Above xxx [%]
Flow rates
(indication only) Peak flow value [m³/h]
for xxxxx [min.]
Water volumes
(indication only) Soft water [m3]
Make-up volume [l]
Counter readings
(indication only) Salt consumption [kg]
Regeneration counter
Find reference position
start
Move to reference position. Ongoing regenerations are cancelled. After completion, the factory setting is activated again.
Operation
51 | 80
BA_TD3-BS001en_014_softliQ
-SD
Menu items
Settings / remarks
Fill operating water volume into brine tank
Start
Fill the brine tank to a minimum water level (e.g. after cleaning the brine tank). After completion, the factory setting is activated again.
Start test regeneration
Start
Functional check of all components involved in the regeneration.
Time of regeneration
Automatic (factory setting)
Fixed
Programming a fixed regeneration time. Regeneration only takes place, if required.
Weekly timer
Mon ... Sun Time of the regeneration on each day of the week – factory setting: Mon - Fri 7:00 am
Save settings profile
none (factory setting)
yes
Save all current parameter settings of the control unit in the Grünbeck Cloud so that you can load them back into the control unit later if necessary.
The parameter settings are saved here as an "Installer" profile in the Grünbeck Cloud.
Generate system data overview*
start
When there is a connection to the access point, all parameter settings can be loaded into the smartphone and a *.pdf document generated.
* Function planned
Operation
52 | 80
BA_TD3-BS001en_014_softliQ
-SD
The following menu items are only available for softliQ:SD21 and softliQ:SD23:
Menu items
Settings / remarks
Inputs and outputs
Programmable output function*
Regeneration water delivery pump – factory setting This setting must be made in connection with the regeneration water delivery pump available as an accessory (refer to chapter 3.7). Contact closed (regeneration water delivery pump running) during the regeneration steps of first filtrate, salting, displacement and backwash.
Regeneration message Contact closed during the entire regeneration.
Function fault signal contact*
N. C. – factory setting Contact closed if mains voltage is applied and
there is no fault.
N. O. Contact closed in the event of a malfunction.
Programmable input function
Leakage detection – factory setting If a leakage is detected at the installation site of
the softliQ system via the water sensor, the message "Leakage at the softliQ installation site" is displayed.
Regeneration lock The regeneration lock is active as long as the
contact at the programmable input is closed; manually released and automatic regenerations after a power failure take priority. A regeneration that has already been started is not cancelled.
Release of regeneration Start of a partial regeneration if the contact at the
programmable input closes.
* Only with softliQ:SD23

6.10 Sending an email if there is a malfunction

If your softliQ water softener is connected to your user account in the Grünbeck Cloud, you will be notified by e-mail in the event of a fault.
Cleaning, inspection, maintenance
53 | 80
BA_TD3-BS001en_014_softliQ
-SD

7 Cleaning, inspection, maintenance

WARNING: Risk of contaminated drinking water if the work is not carried out properly.
Risk of infectious diseases. Pay attention to hygiene when working on the product.
Inspection and maintenance of a water softener is prescribed in the DIN EN 806-5 standard. Regular maintenance ensures trouble-free, hygienic operation. At least once a year, the water softener must be serviced by Grünbeck's technical service / authorised service company or by specialist installers trained by Grünbeck.
A maintenance contract ensures that all the required maintenance work will be performed in due time.
Only use genuine spare and wearing parts from Grünbeck.

7.1 Cleaning

Only clean the outside of the product.
Do not use any strong or abrasive cleaning agents.
Wipe the housing with a damp cloth.
The salt tank is cleaned once a year by the specialist installer during maintenance work.
Cleaning, inspection, maintenance
54 | 80
BA_TD3-BS001en_014_softliQ
-SD

7.2 Inspection

Regular inspection increases the operational reliability of your product.
Conduct an inspection at least every 2 months.
To conduct an inspection, proceed as follows:
1. Check the soft water hardness (refer to chapter 6.6).
2. Check that there are sufficient salt tablets in the brine tank.
The level of salt tablets in the brine tank must always be higher than the water level. The water level is normally approx. 1 cm above the sieve bottom.
3. Check the leak-tightness of the connection hoses.
4. Check the control valve to the drain for leaks.
No water is allowed to drip out of the flushing water hose during operation. The water softener is in operation when the blue symbol is displayed in information level 1 (refer to chapter 6.1).

7.3 Intervals

For this purpose, DIN EN 806-5 recommends a semi-annual and an annual maintenance.
Operation
Interval
Execution
Inspection
2 months
Visual inspection for function, leakage
Maintenance
6 months
Visual / functional check, leakage test, check salt condition and quantity, assess consumption, soft check soft water hardness, check water sensor function
Annually
Semi-annual maintenance + check operating values, read counter readings, clean components, check wearing parts
Maintenance
5 years
Recommended: Replacement of wearing parts
Cleaning, inspection, maintenance
55 | 80
BA_TD3-BS001en_014_softliQ
-SD

7.4 Maintenance

7.4.1 Semi-annual maintenance

In order to carry out the semi-annual maintenance, proceed as follows:
1. Check the soft water hardness (refer to chapter 6.6).
2. Check that there are sufficient salt tablets in the brine tank.
The level of salt tablets in the brine tank must always be higher than the water level. The water level is normally approx. 1 cm above the sieve bottom.
3. Evaluate the salt consumption subject to the water volume consumed.
4. Check the salt condition (salt must not be lumpy).
Break up incrustations with a suitable tool.
5. Check the function of the water sensor by immersing the water sensor in water or
alternatively bridge it with a metallic object.
» The water sensor is working if the water softener issues a warning message after
30 seconds at the latest.
Cleaning, inspection, maintenance
56 | 80
BA_TD3-BS001en_014_softliQ
-SD

7.4.2 Annual maintenance

Carrying out annual maintenance work requires specialist knowledge. This maintenance work may only be performed by Grünbeck's technical service / authorised service company or by specialist installers trained by Grünbeck.
The following points are included in addition to the six-monthly maintenance:
Operating values
1. Measure the raw water hardness.
2. Match the measured raw water hardness to the setting in the control unit.
3. Measure the soft water hardness.
4. If necessary, adjust the blending valve and check the soft water hardness.
5. Read off the water and flow pressure.
6. Read off the residential water meter reading.
7. Read off the regeneration counter.
8. Read off the soft water volume meter.
9. Read out the error memory.
Maintenance work
10. Check the hose connections for leaks and damage.
11. Check the soft water meter for pulse emission (current flow during operation, refer
to chapter 6.1).
12. Check all cables and connections for damage and a firm seat.
13. Check the injector and injector sieve for dirt and clean them if necessary.
14. Check the brine filling orifice in the brine connection angle (red).
15. Check the brine valve and the level electrodes and clean them if necessary.
16. Clean the brine tank.
17. Start a manual regeneration.
18. Check the suction power of the injector.
19. Check the chlorine current when salting.
20. Check the function of the regeneration counter during backwashing by observing
the code-protected level 005.
21. Check the control valve at the drain outlet in the operating position for leaks (flushing water, filling and suction hose).
22. Check the filling and suction hose to the brine valve for leaks.
23. Reset the service interval, if activated.
24. Enter the maintenance in the operation log (refer to chapter 13).
Cleaning, inspection, maintenance
57 | 80
BA_TD3-BS001en_014_softliQ
-SD

7.5 Consumables

Product
Order no.
Regeneration salt tablets (25 kg) acc. to DIN EN 973 type A
127 001
Water test kit "Total hardness”
170 187

7.6 Spare parts

For spare parts and consumables please contact your local representative. You can find these on the Internet at www.gruenbeck.de.
Cleaning, inspection, maintenance
58 | 80
BA_TD3-BS001en_014_softliQ
-SD

7.7 Wearing parts

Wearing parts are listed below:
Control valve: Gaskets, set of discs, injector and chlorine cell.
Item
Designation
Item
Designation
1
Injector (with circlip)
2
Chlorine cell (with circlip)
3
Regeneration disc pair (with flow stabiliser)
Brine valve: Gaskets and electrodes.
Item
Designation
Item
Designation
1
Seal 2 Electrodes
Malfunction
59 | 80
BA_TD3-BS001en_014_softliQ
-SD

8 Malfunction

WARNING: Danger of contaminated drinking water due to stagnation.
Risk of infectious diseases. Have malfunctions remedied immediately.
The water softener softliQ indicates malfunctions on the display. As soon as a fault appears, the touch-screen display changes to the basic display and remains active until the fault is rectified.
If malfunctions cannot be remedied by the instructions given below, contact
Grünbeck's technical service / authorised service company.
Have your equipment data (refer to chapter 1.7) handy.

8.1 Display messages

1. Acknowledge the display signal with rectify.
2. Watch the display.
3. If the fault occurs again, compare the display message with the following table.

8.1.1 Warning messages (yellow symbols)

Display shows
Explanation
Remedy
Perform maintenance
since … days
Only displayed if maintenance interval is activated.
Notify Grünbeck's technical service / authorised service company.
SD21 and SD23 only:
Leak at the
softliQ installation location
Water sensor has electrical connection.
Check whether water is leaking. If necessary, close the main valve of the house installation.
SD21 and SD23 only:
Salt supply low! Please refill!
Sufficient for: xy days
(order no. 127 001)
Salt supply low.
Refill salt tablets (refer to chapter 6.3).
Confirm with Rectify.
Malfunction
60 | 80
BA_TD3-BS001en_014_softliQ
-SD

8.1.2 Error messages (red symbols)

Display shows
Explanation
Remedy
Power failure > 5 minutes
Only displayed if detection is activated.
Water softener will perform a regeneration as soon as the electrical power supply returns.
If there is a power failure, any regeneration in progress at the time is stopped and then continued afterwards.
Check the electrical connection. Reset the clock of the water softener
if there is a power failure > 3 days (refer to chapter 6.2).
Start a manual regeneration (refer to chapter 6.5).
Salt supply used up! Refill
immediately!
(Order no. 127 001)
Cavity under the salt.
Break up incrustations with a suitable tool.
Salt supply used up.
Refill salt tablets (refer to chapter 6.3).
Confirm with Rectify.
Water pressure too low.
Increase the flow pressure to min.
2.0 bar.
Chlorine cell worn. Brine filling orifice,
injector, injector sieve or brine valve clogged.
Notify Grünbeck's technical service / authorised service company.
Malfunction at the drive
to the regeneration control valve!
Step monitoring of regeneration motor or connecting cable defective.
Notify Grünbeck's technical service / authorised service company.
Regeneration water meter
Quantity not reached!
Regeneration water meter is not supplying any pulses.
Connecting cable defective.
Water supply interrupted. Safety float on brine
valve closed.
Check the water supply. Notify Grünbeck's technical service /
authorised service company.
Water meter
soft water defective
Soft water meter is not emitting any pulses.
Connecting cable defective.
Water supply interrupted.
Check the water supply. Notify Grünbeck's technical service /
authorised service company.
Malfunction
61 | 80
BA_TD3-BS001en_014_softliQ
-SD
Display shows
Explanation
Remedy
Water meter
regeneration defective
Regeneration water meter is not supplying any pulses.
Connecting cable defective.
Water supply interrupted.
Check the water supply. Notify Grünbeck's technical service /
authorised service company.
System does not draw brine
from the brine tank effectively
enough
Minimum contact during salting not reached. Monitoring time exceeded.
Injector clogged or raw water pressure too low.
Notify Grünbeck's technical service / authorised service company.
Nominal flow rate
exceeded
Only displayed if monitoring was activated by the specialist installer.
System is being operated with excessive flow rates.
Reduce the flow rate. If the error persists, notify Grünbeck's
technical service / authorised service company.
Water loss to drain
Water loss to drain.
Notify Grünbeck's technical service / authorised service company.
Motor output defective
Short-circuit at the motor or at the connecting cable to the motor.
Notify Grünbeck's technical service / authorised service company.
Malfunction
62 | 80
BA_TD3-BS001en_014_softliQ
-SD
Fault messages that may occur during start-up
Display shows
Explanation
Remedy
Error during commissioning
(venting)
Time monitoring of the venting (backwash) has tripped. No flow was detected at the regeneration water meter.
Check that the shut-off valves on the connection block are open.
Error during start-up
(fill brine tank)
Time monitoring for filling the brine tank has been triggered.
Check whether the raw water shut-off valve is open.
Confirm with Rectify. Repeat the start-up.
Error during start-up
(chlorine current too low)
Flow monitoring during test regeneration has been triggered.
Fill the brine tank with salt tablets if you have not already done so.
Confirm with Rectify. Repeat the start-up.
Error during commissioning
(referencing)
Step monitoring regeneration motor
or connecting cable defective.
Confirm with Rectify. Repeat the start-up. Notify Grünbeck's technical service /
authorised service company if the malfunction reoccurs.
Malfunction
63 | 80
BA_TD3-BS001en_014_softliQ
-SD

8.2 Other observations

Observation
Meaning
Remedy
No soft water
Excessive water consumption (water softener has exceeded its capacity).
Restrict your water consumption to the maximum flow rate permitted (refer to chapter 11).
Start a manual regeneration (refer to chapter 6.5).
Water softener does not have a permanent power connection.
Check the electrical connection. Soft water meter is not emitting any pulses.
Notify Grünbeck's technical service / authorised service company.
Raw water hardness set too low.
Measure the raw water hardness (refer to chapter 6.6).
Update the value in the control unit (refer to chapter 6).
Blending valve incorrectly set.
Set the blending valve (refer to chapter 6.8).
Water supply interrupted.
Check that the shut-off valves on the connection block are open.
Resin beads in the flushing water hose or aerator
Defective jet system.
Notify Grünbeck's technical service / authorised service company.
Water pressure at the withdrawal point too low.
(Pressure loss too high.)
Resin may be polluted by undissolved particles.
If the problem comes from the water softener, contact Grünbeck's technical service / authorised service company.
Start-up program: When venting (steps 1 – 9) or during test regeneration, the display stops for more than 20 minutes – no further changes.
Connection hoses are connected reversed (raw water and soft water).
Check the assignment of the connection hoses (refer to "Connection hoses").
If necessary, close both shut-off valves on the connection block, start manual regeneration, loosen and exchange hoses on the connection block and open shut-off valves.
Rattling noise at the connection block during water draw-off
Information on faults with the Grünbeck Cloud can be found on the Internet at the following address: https://www.gruenbeck.de/en/become-a-water-expert/faq/
Shut-down and restart
64 | 80
BA_TD3-BS001en_014_softliQ
-SD

9 Shut-down and restart

It is not necessary to put your product out of operation. Should you do so nevertheless, please take the information given in the present chapter into consideration.

9.1 Shut-down

In accordance with DIN 19636-100, your water softeners are regenerated after 4 days, even if the softening capacity has not yet been exhausted by that time. The stagnation of water is prevented.
Leave your product connected to electricity and water.
Should you wish to temporarily shut down your water supply due to a longer period of absence, proceed as follows:
1. Close the soft water shut-off valve.
2. Leave the raw water shut-off valve open.
3. Keep the water softener connected to power.
» The product remains in an operating state which is considered to be safe with
regard to hygiene and which is admissible according to DIN EN 19636-100.

9.2 Restart

In order to put your product back into operation again, proceed as follows:
1. Open the soft water shut-off valve.
2. Open a water draw-off point for approx. 5 minutes.
» The product is ready for operation.
Dismantling and disposal
65 | 80
BA_TD3-BS001en_014_softliQ
-SD

10 Dismantling and disposal

10.1 Dismantling

The work described herein represents an intervention into your drinking water system. Have this work performed by specialist installers only.
1. Close the raw water shut-off valve.
2. Open a water withdrawal point.
3. Wait for a few seconds.
» The pressure in the product and the pipe network is being relieved.
4. Close the water withdrawal point.
5. Disconnect the product from mains.
6. Separate the product from the connection hoses.
Keep a collecting vessel (e.g. a bucket) handy to catch escaping water.
7. Separate the connection hoses from the connection block.
8. Dismantle the connection block.
9. Close the gap in your drinking water installation, e.g. by using an adjusting piece
(e.g. order no. 128 001).
Dismantling and disposal
66 | 80
BA_TD3-BS001en_014_softliQ
-SD

10.2 Disposal

Comply with the applicable national regulations.

10.2.1 Packaging

Dispose of the packaging in an environmentally sound manner.

10.2.2 Product

If this symbol (crossed out waste bin) is on the product, European Directive 2012/19/EU applies to this product. This means that this product or the electric and electronic components are not allowed to be disposed of in the household waste.
Find out about local regulations on the separate collection of electrical and
electronic products.
Use the collection points available to you for disposing of your product.
For information on collection points for your product, contact your municipality, the public waste disposal authority, an authorised body for the disposal of electrical and electronic products or your waste collection service.
Technical specifications
67 | 80
BA_TD3-BS001en_014_softliQ
-SD

11 Technical specifications

Dimensions and weights
softliQ:SD18
softliQ:SD21
softliQ:SD23
A System width
[mm]
360
B System height
[mm]
815
C System depth
[mm]
430
D Connection height of control valve (soft water)
[mm]
470
E Connection height of control valve (raw water)
[mm]
510
F Height of safety overflow of brine tank
[mm]
520
G Height with open lid
[mm]
1060
H Installation length without screw connection
[mm]
190
I Installation length with screw connection
[mm]
271
Operating weight, approx.
[kg]
65
69
73
Shipping weight, approx.
[kg]
22
24
26
Technical specifications
68 | 80
BA_TD3-BS001en_014_softliQ
-SD
Connection data
softliQ:SD18
softliQ:SD21
softliQ:SD23
Nominal connection diameter
DN 25 (1" male thread)
Min. drain connection. DN 50
Rated voltage range
[V]
100 - 250
Rated frequency
[Hz]
50 - 60
Rated consumption (during regeneration, temporarily)
[W]
8
14
Softening power consumption, if display, Wi-Fi and illuminated LED ring are switched off (illuminated LED ring only for softliQ:SD21 and softliQ:SD23)
[W]
< 3.5
Protection / protection class
IP54/
Performance data
softliQ:SD18
softliQ:SD21
softliQ:SD23
Nominal pressure PN 10
Rated pressure
[MPa]/
[bar]
1.0/10
Min. / max. operating pressure (recommended)
[bar]
2.0/8.0 (4.0)
Nominal flow (0 °dH, 0 °f, 0 mol/m³) acc. to DIN EN 14743 at a pressure loss of 1.0 bar (theoretical value))
[m³/h]
1.8
2.1
2.3
Nominal flow at a pressure loss of 1.0 bar acc. to DIN 19636 (raw water hardness 20 °dH (35.6 °f, 3.56 mol/m³), soft water hardness 8 °dH (14.2 °f, 1.42 mol/m³))
[m³/h]
3.0
3.5
3.8
Nominal capacity variable
[m³ x °dH]
[m³ x °f]
[mol]
6 - 14
11 - 25
1.1 - 2.5
8 - 20
14 - 36
1.4 - 3.6
9 - 23
16 - 41
1.6 - 4.1
Capacity per kg of regeneration salt
[mol/kg]
6.7 - 4.5
7.1 - 4.5
Regeneration time for a complete regeneration
[min.]
20 - 40
Regeneration (1x per day) in case of reduction in capacity
[%]
> 50
Filling volumes and consumption data
softliQ:SD18
softliQ:SD21
softliQ:SD23
Resin volume
[l]
5
7.5
9
Salt consumption per full regeneration
[kg]
0.15 - 0.55
0.20 - 0.80
0.23 - 0.95
Max. capacity of brine tank
[kg]
35
Salt consumption per m³ and °dH per m³ and °f per m³ and mol
[kg/m³ x °dH]
[kg/m³ x °f]
[kg/mol]
0.025 - 0.040
0.014 - 0.022
0.140 - 0.221
Max. flushing water flow
[m³/h]
0.3
0.4
0.6
Total waste water volume per full regeneration
[l]
21 - 31
28 - 43
32 - 51
Waste water volume per m³ and °dH (complete regeneration) per m³ and °f (complete regeneration) per m³ and mol (complete regeneration)
[l/m³ x °dH]
[l/m³ x °f]
[l/mol]
3.5 - 2.2
1.9 - 1.2 19 - 12
General data
softliQ:SD18
softliQ:SD21
softliQ:SD23
Suitable for homes of ... families (up to ... people)
1 - 2 (4)
1 - 4 (9)
1 - 5 (12)
Water temperature
[°C]
5 – 30
Ambient temperature (drinking water)
[°C]
5 – 25
Ambient temperature (technical application)
[°C]
5 – 40
Max. humidity of air (non-condensing)
[%]
90
DVGW registration number
DW-9151CT0491
SVGW registration number
test pending
Order no.
189 100
189 200
189 300
Other information
69 | 80
BA_TD3-BS001en_014_softliQ
-SD

12 Other information

12.1 Sodium content in the water

When softening water by 1 °dH (0.18 mmol/l), the sodium content increases by approx. 8.2 mg/l.
The German Drinking Water Ordinance specifies that the sodium content of drinking water must not exceed 200 mg/l.
Select a soft water hardness with a sodium content less than 200 mg/l.
The local water suppliers will inform you about the sodium content of your raw water.

Sample calculation:

Raw water hardness: 28 °dH (50 °f, 5 mmol/l) Sodium content in the raw water: 10.5 mg/l
Admissible increase of the sodium content by softening:
200 mg/l - 10.5 mg/l = 189.5 mg/l
189.5 : 8.2 = 23 °dH (41 °f, 4,1 mmol/l)
The raw water hardness may be reduced from 28 °dH (50 °f, 5 mmol/l) to 5 °dH (9 °f, 0.9 mmol/l).

12.2 Hardness ranges

The hardness ranges were classified according to the German Act on Detergents and Cleaning Agents.
Hardness range
°dH
°f
Soft
< 8.4
< 15
Medium
8.4 - 14
15 - 25
Hard
> 14
> 25
When dosing cleaning agents, take account of the new hardness range of your
soft water.
Operation log
70 | 80
BA_TD3-BS001en_014_softliQ
-SD

13 Operation log

Water softener softliQ:SD___
Serial no.: ________________

Start-up log

Customer
Name:
Address:
Installation / accessories
Drinking water filter (make / type):
Drain connection acc. to DIN EN 1717
yes
no
Floor drain available
yes
no
Safety device
yes
no
Regeneration water lifting system
yes
no
Make:
Dosing
yes
no
Active agent:
Operating values
Water pressure
[bar]
Reading of residential water meter
[m³]
Hardness unit
[°dH]
[°f]
[mol/m³]
[°e]
[°ppm]
Raw water hardness (measured)
Raw water hardness (set)
Soft water hardness (set)
Remarks
Start-up
Company:
Service technician:
Work time certificate (no.):
Date / signature:
Operation log
71 | 80
BA_TD3-BS001en_014_softliQ
-SD

1st maintenance

Operating values
Raw water hardness measured / set
/
Soft water hardness measured / set
/
Soft water hardness 0 °dH inspection
OK
Operating pressure
[bar]
Reading of residential water meter
[m³]
Soft water volume meter
[m³]
Regeneration counter
Read out error memory
Error
Date
Time
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Maintenance work
OK
Hose connections checked for leaks and damage
Soft water meter checked for pulse output
Regeneration water meter checked for pulse output
Cables checked for damage and firm seating
Injector and injector sieve cleaned / checked
Chlorine cell checked
Brine valve level electrodes cleaned / replaced
Brine tank cleaned
Salt tablets checked for cleanliness
Reference position moved to manually (C 005)
Suction power of the injector checked during salting:
0.1 l in 60 – 120 s
Current at the chlorine cell during salting
Water sensor checked for function
Product / control valve checked for leaks
Flushing water hose checked for leaks in operation
Filling and suction hose to the brine valve checked for leaks during operation
Maintenance interval reset
Remarks
Performed by
Company:
Service technician:
Operation log
72 | 80
BA_TD3-BS001en_014_softliQ
-SD

2nd maintenance

Operating values
Raw water hardness measured / set
/
Soft water hardness measured / set
/
Soft water hardness 0 °dH inspection
OK
Operating pressure
[bar]
Reading of residential water meter
[m³]
Soft water volume meter
[m³]
Regeneration counter
Read out error memory
Error
Date
Time
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Maintenance work
OK
Hose connections checked for leaks and damage
Soft water meter checked for pulse output
Regeneration water meter checked for pulse output
Cables checked for damage and firm seating
Injector and injector sieve cleaned / checked
Chlorine cell checked
Brine valve level electrodes cleaned / replaced
Brine tank cleaned
Salt tablets checked for cleanliness
Reference position moved to manually (C 005)
Suction power of the injector checked during salting:
0.1 l in 60 – 120 s
Current at the chlorine cell during salting
Water sensor checked for function
Product / control valve checked for leaks
Flushing water hose checked for leaks in operation
Filling and suction hose to the brine valve checked for leaks during operation
Maintenance interval reset
Remarks
Performed by
Company:
Service technician:
Operation log
73 | 80
BA_TD3-BS001en_014_softliQ
-SD

3rd maintenance

Operating values
Raw water hardness measured / set
/
Soft water hardness measured / set
/
Soft water hardness 0 °dH inspection
OK
Operating pressure
[bar]
Reading of residential water meter
[m³]
Soft water volume meter
[m³]
Regeneration counter
Read out error memory
Error
Date
Time
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Maintenance work
OK
Hose connections checked for leaks and damage
Soft water meter checked for pulse output
Regeneration water meter checked for pulse output
Cables checked for damage and firm seating
Injector and injector sieve cleaned / checked
Chlorine cell checked
Brine valve level electrodes cleaned / replaced
Brine tank cleaned
Salt tablets checked for cleanliness
Reference position moved to manually (C 005)
Suction power of the injector checked during salting:
0.1 l in 60 – 120 s
Current at the chlorine cell during salting
Water sensor checked for function
Product / control valve checked for leaks
Flushing water hose checked for leaks in operation
Filling and suction hose to the brine valve checked for leaks during operation
Maintenance interval reset
Remarks
Performed by
Company:
Service technician:
Operation log
74 | 80
BA_TD3-BS001en_014_softliQ
-SD

4th maintenance

Operating values
Raw water hardness measured / set
/
Soft water hardness measured / set
/
Soft water hardness 0 °dH inspection
OK
Operating pressure
[bar]
Reading of residential water meter
[m³]
Soft water volume meter
[m³]
Regeneration counter
Read out error memory
Error
Date
Time
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Maintenance work
OK
Hose connections checked for leaks and damage
Soft water meter checked for pulse output
Regeneration water meter checked for pulse output
Cables checked for damage and firm seating
Injector and injector sieve cleaned / checked
Chlorine cell checked
Brine valve level electrodes cleaned / replaced
Brine tank cleaned
Salt tablets checked for cleanliness
Reference position moved to manually (C 005)
Suction power of the injector checked during salting:
0.1 l in 60 – 120 s
Current at the chlorine cell during salting
Water sensor checked for function
Product / control valve checked for leaks
Flushing water hose checked for leaks in operation
Filling and suction hose to the brine valve checked for leaks during operation
Maintenance interval reset
Remarks
Performed by
Company:
Service technician:
Operation log
75 | 80
BA_TD3-BS001en_014_softliQ
-SD

5th maintenance

Operating values
Raw water hardness measured / set
/
Soft water hardness measured / set
/
Soft water hardness 0 °dH inspection
OK
Operating pressure
[bar]
Reading of residential water meter
[m³]
Soft water volume meter
[m³]
Regeneration counter
Read out error memory
Error
Date
Time
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Maintenance work
OK
Hose connections checked for leaks and damage
Soft water meter checked for pulse output
Regeneration water meter checked for pulse output
Cables checked for damage and firm seating
Injector and injector sieve cleaned / checked
Chlorine cell checked
Brine valve level electrodes cleaned / replaced
Brine tank cleaned
Salt tablets checked for cleanliness
Reference position moved to manually (C 005)
Suction power of the injector checked during salting:
0.1 l in 60 – 120 s
Current at the chlorine cell during salting
Water sensor checked for function
Product / control valve checked for leaks
Flushing water hose checked for leaks in operation
Filling and suction hose to the brine valve checked for leaks during operation
Maintenance interval reset
Remarks
Performed by
Company:
Service technician:
Operation log
76 | 80
BA_TD3-BS001en_014_softliQ
-SD

6th maintenance

Operating values
Raw water hardness measured / set
/
Soft water hardness measured / set
/
Soft water hardness 0 °dH inspection
OK
Operating pressure
[bar]
Reading of residential water meter
[m³]
Soft water volume meter
[m³]
Regeneration counter
Read out error memory
Error
Date
Time
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Maintenance work
OK
Hose connections checked for leaks and damage
Soft water meter checked for pulse output
Regeneration water meter checked for pulse output
Cables checked for damage and firm seating
Injector and injector sieve cleaned / checked
Chlorine cell checked
Brine valve level electrodes cleaned / replaced
Brine tank cleaned
Salt tablets checked for cleanliness
Reference position moved to manually (C 005)
Suction power of the injector checked during salting:
0.1 l in 60 – 120 s
Current at the chlorine cell during salting
Water sensor checked for function
Product / control valve checked for leaks
Flushing water hose checked for leaks in operation
Filling and suction hose to the brine valve checked for leaks during operation
Maintenance interval reset
Remarks
Performed by
Company:
Service technician:
EC Declaration of Conformity
77 | 80

EC Declaration of Conformity

In accordance with the Radio Equipment Directive 2014/54/EU, Appendix IV
This is to certify that the system designated below complies with the safety and health requirements of
the applicable European Directives in terms of its design, construction and execution.
This certificate will become invalid if the system is subjected to unauthorised modification.
Water softener softliQ:SD
Serial no.: refer to type plate
The aforementioned system also complies with the following directives and provisions:
Directive on the Restriction of Hazardous Substances RoHS (2011/65/EC)
Electrical and Electronic Equipment Ordinance
The following harmonised standards have been applied:
DIN EN 61000-6-2:2006-03
DIN EN 61000-6-3:2011-09
DIN EN 60335-1:2012-10
The following national standards and regulations have been applied:
DIN 19636-100:2008-02
DIN EN 14743:2007-09
Responsible for documentation:
Dipl.-Ing. (FH) Markus Pöpperl
Manufacturer
Grünbeck Wasseraufbereitung GmbH
Josef-Grünbeck-Str. 1
89420 Hoechstaedt/Germany
Hoechstaedt; Germany, February 2019
i.V. Dipl.-Ing. (FH) Markus Pöpperl
Head of Technical Product Design
Index
78 | 80

Index

B
Blending valve ............................................................. 49, 56
Brine tank lid ..................................................................... 46
C
Connection block ............................................................... 22
Connection hoses .............................................................. 23
Control unit ...................................................... 14, 17, 52, 56
D
Determining and entering the water hardness ................... 47
Drinking water ............................................................. 10, 69
I
Illuminated LED ring .................................................... 14, 40
Inspection .................................................................... 53, 54
Intervals ............................................................................ 54
M
Maintenance .......................................................... 53, 55, 56
Malfunction ............................................................ 14, 52, 59
Menu structure .................................................................. 38
O
Operation .......................................................................... 64
P
Power mode...................................................................... 13
R
Raw water .................................................................... 28, 69
Regeneration agent ............................................................ 9
Regeneration water ........................................................... 24
S
Salt tablets ............................................. 9, 25, 26, 46, 54, 55
Select regeneration time ................................................... 49
Soft water .............................................................. 10, 28, 56
Spare parts ....................................................................... 57
Starting a manual regeneration ......................................... 47
Start-up ........................................................................ 25, 36
Start-up program ............................................................... 36
System capacity ................................................................ 13
W
Wearing parts ................................................................... 58
Grünbeck Wasseraufbereitung GmbH Josef-Grünbeck-Str. 1 89420 Hoechstaedt GERMANY
For more Information go to www.gruenbeck.com
+49 9074 41-0
+49 9074 41-100
info@gruenbeck.com www.gruenbeck.com
Loading...