Iron / manganese removal
Demanganisation system GENO-mat MN-Z
Order no. 095 153 048-inter Edited by: nkes-mrie G:\BA-153048-INTER_095_GENO-MAT_MN-Z.DOCX
12
Table C-1: Technical specifications Demanganisation system GENO-mat MN-Z
20/10 25/13 30/14 40/17 40/18 50/19 60/20
Connection data
Nominal connection diameter DN 25 (1") DN 40 (1½“)
Min. drain connection DN 50 DN 70
Nominal flow rate (depending on the iron concen-
tration)
[m³/h] 1.5 2.0 3.0 4.0 5.0 6.0 8.0
Power supply [V/Hz]
230 V, 50 Hz
operation with protective low voltage 24 V/50 Hz
Connected load [VA] 10
Protection type IP 54
Performance data
Nominal pressure (PN) 8.0
Min./max. operating pressure [bar] 2.5/6.0
Pressure loss at nominal flow [bar] 0.5 1.1 1.0 1.1 1.0 0.8 1.1
Dimensions and weights1)
Total height [mm] 1360 1620 1620 1900 1900 1870 2100
Exchanger tank
[mm]
210 260 340 370 420 550 620
Regeneration tank
[mm]
465 680
Height of regeneration tank [mm] 840 1010
Connection height/raw water piping [mm] 1160 1420 1420 1710 1710 1680 1910
Connection height/pure water piping [mm] 1210 1470 1470 1735 1735 1705 1935
Distance to wall [mm] 200 230 280 280 300 365 405
Depth of foundation [mm] 400 450 500 500 550 600 650
Length of foundation [mm] 1850 1950 2050 2050 2100 2250 2350
Operating weight (incl. water) [kg] 76 135 213 311 361 642 947
Filling volume and consumption data1)
Filter layer I, bottom, gravel 3.0 - 5.6 [kg] 10 10 25 25 25 50 50
Filter layer I, bottom, gravel 3.0 - 5.6 [l] 7 7 18 18 18 35 35
Filter layer I, bottom, gravel 3.0 - 5.6 (dimension a) [mm] 860 1170 1100 1400 1430 1320 1570
Filter layer II, middle, GENO Fermanit [kg] 25 50 50 100 125 200 325
Filter layer II, middle, GENO Fermanit [l] 12.5 25 25 50 63 100 163
Filter layer II, middle, GENO Fermanit (dimension b) [mm] 500 690 810 930 950 900 1020
Filter layer III, top, with quartz sand 0.4 – 0.8 [kg] 10 25 50 75 75 150 250
Filter layer III, top, with quartz sand 0.4 – 0.8 [l] 7 17 33 50 50 100 167
Filter layer III, top, with quartz sand 0.4 – 0.8 (dimen-
sion c)
[mm] 300 370 430 460 560 490 450
Free board [l] 7 12 30 22 40 74 71
Amount of regeneration agent required
Preparation amount [l] 302) 502) 602) 1002) 1002) 2002) 3002)
GENO special granulate [g] 105 175 210 350 350 700 1050
GENO-oxi plus [l] 5 9 11 17 17 35 53
Total waste water volume per regeneration (3 bar) [m³] 1 1.3 1.7 2 2.7 3.4 5.4
Ambient data
Duration of washing out (regeneration) [min.] 30
Duration of backwash [min.] 10
Backwash capacity [m³/h] 1.6 2.3 3.4 5.7
Max. water temperature [°C] 30
Max. ambient temperature [°C] 40
Order no. 153 … 410 420 430 440 450 460 470
Spare filter filling3)
Order no. 153 … 020 022 024 026 028 030 032
1)
All indications are approximate.
2)
If the liquid product GENO-oxi plus is used, the GENO-oxi plus amount must be subtracted from the batch size.
3)
all three filter layers