Grunbeck FE-Z 25/13, FE-Z 40/17, FE-Z 20/10, FE-Z 30/14, FE-Z 40/18 Operation Manual

...
 
Operation Manual
GENO-mat FE-Z
Deferrisation system
Deferrisation
GENO-mat FE-Z Deferrisation System
Table of contents
A General .................................................................................
1 Preface
2 How to use this operation manual 3 General safety information 4 Shipping and storage 5 Disposal
B Basic information ................................................................ 10
1 Laws, regulations, standards
2 Intended use/field of application 3 Function
C Product description ............................................................. 12
1 Type plate
2 Technical specifications 3 Intended use 4 Scope of delivery 5 Optional accessories 6 Consumables
D Installation and operation ................................................... 17
1 General installation information
2 Preliminary works 3 How to connect the system
E Start-up ................................................................................. 22
1 How to start up the system
F Operation .............................................................................. 23
1 How to operate the control unit
G Maintenance and care ......................................................... 26
1 Basic information
2 Inspection (functional check) 3 Maintenance 4 Spare parts 5 Operation log
5
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
2
Deferrisation
GENO-mat FE-Z Deferrisation System
 
All rights reserved.
© Copyright by Grünbeck Wasseraufbereitung GmbH
Printed in Germany Effective with the date of edition indicated on the cover sheet.
-We reserve the right to modifications, especially with regard to technical progress-
Reprints, translations into foreign languages, electronic storage or copying - even in part - of this operation manual are only permitted with the explicit written approval of Grünbeck Wasseraufbereitung GmbH.
Any type of duplication not authorised by Grünbeck Wasseraufberei­tung is a copyright violation and subject to legal action.
Responsible for contents:
Grünbeck Wasseraufbereitung GmbH Josef-Grünbeck-Str. 1  89420 Hoechstaedt/Do., Germany Tel. +49 (0) 9074 41-0 Fax +49 (0) 9074 41-100 www.gruenbeck.de service@gruenbeck.de
Print: Grünbeck Wasseraufbereitung GmbH Josef-Grünbeck-Str.1, 89420 Hoechstaedt/Do., Germany
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
3
Deferrisation
GENO-mat FE-Z Deferrisation System
EC Declaration of Conformity
This is to certify that the systems designated below meets the safety and health requirements of the applicable European guidelines in terms of its design, construction and execution.
If the systems are modified in a way not approved by us, this certificate is void.
Manufacturer: Grünbeck Wasseraufbereitung GmbH
Josef-Grünbeck-Str.1 89420 Hoechstaedt/Do., Germany
Responsible for documentation: Markus Pöpperl
Description of the device: Deferrisation system
Device type: GENO-mat FE-Z
Device no.: Refer to type plate
Applicable guidelines: Low Voltage (2014/35/EU)
EMC (2014/30/EU)
Applied harmonised standards in particular:
Applied national standards and technical specifications, in particular:
Place, date and signature: Hoechstaedt, 10.09.2018 p.p.
Function of signatory: Head of Technical Product Design
DIN EN 61000-6-2:2006-03 DIN EN 61000-6-3:2011-09
DIN 19636-100:2008-02
M. Pöpperl
Dipl.-Ing. (FH)
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
4
A General
Deferrisation
GENO-mat FE-Z Deferrisation System
1 | Preface
Thank you for opting for a Grünbeck product. Backed by decades of
experience in the area of water treatment, we provide solutions for all kind of processes.
Drinking water is classified as food and requires particular care. Therefore, always ensure the required hygiene in operating and maintaining systems involved in the drinking water supply. This also applies to the treatment of water for industrial use if repercussions for the drinking water cannot completely be excluded.
All Grünbeck systems and devices are made of high-quality materials. This ensures reliable operation over many years, provided you treat your water treatment systems with the required care. This operation manual assists you with important information. Therefore, please read the complete manual before installing, operating or maintaining your system.
Customer satisfaction is our prime objective. Providing customers with qualified advice is crucial to Grünbeck. If you have any ques­tions concerning this system, possible extensions or general water and waste water treatment, our field staffs, as well as the experts at our headquarters in Hoechstaedt, are available to help you.
For help and advice
please consult the representatives responsible for your region (see www.gruenbeck.de) or get in touch with our service centre which can be reached during office hours:
Phone: +49 9074 41-333
Fax: +49 9074 41-120
Email: service@gruenbeck.de
We can connect you with the appropriate expert more quickly if you provide the required system data. In order to have the required data handy at all times, please copy it from the type plate to the overview in chapter C-1.
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
5
Deferrisation
GENO-mat FE-Z Deferrisation System
2 | How to use this operation manual
This operation manual is intended for the operators of our systems.
It is divided into several chapters (a letter is assigned to each of them) which are listed in the “Table of contents” on page 2 in alpha­betical order. In order to find the specific information you are looking for, check for the corresponding chapter on page 2.
The headers and page numbers with chapter information make it easier to find your way around in the manual.
3 | General safety information
3.1 Symbols and notes
Important information in this operation manual is characterised by symbols. Please pay particular attention to this information to ensure the hazard-free, safe and efficient handling of the system.
Danger! Failure to adhere to this information will cause serious or life-threatening injuries, extreme damage to property or inadmissible contamination of the drinking water.
Warning! Failure to adhere to this information may cause injuries, damage to property or contamination of the drinking water.
Caution! Failure to adhere to this information may result in damage to the system or other objects.
Note: This symbol characterises information and tips to make your work easier.
Tasks with this symbol may only be performed by Grünbeck's tech­nical service/authorised service company or by persons expressly authorised by Grünbeck.
Tasks with this symbol may only be performed by qualified electrical experts according to the VDE guidelines or according to the guide­lines of a similar local institution.
Tasks with this symbol may only be performed by water companies or approved installation companies. In Germany, the installation company must be registered in an installation directory of a water company as per §12(2) AVBWasserV (German Ordinance on Gen­eral Conditions for the Supply of Water).
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
6
3.2 Operating personnel
3.3 Designated application
3.4 Protection from water damage
Deferrisation
GENO-mat FE-Z Deferrisation System
Only persons who have read and understood this operation manual are permitted to work with the system. The safety guidelines are to be strictly adhered to.
The system may only be used for the purpose outlined in the product description (chapter C). The guidelines in this operation manual as well as the applicable local guidelines concerning the drinking water protection, accident prevention and occupational safety must be ad­hered to.
In addition, appropriate application also implies that the system may only be operated when it is in proper working order. Any malfunctions must be repaired at once.
Warning! In order to properly protect the installation site from water damage:
a) a sufficiently dimensioned floor drain system must be available or
3.5 Indication of specific dangers
b) a water stop device (see chapter C Accessories) must be in-
stalled.
Danger due to electrical energy!  Do not touch electrical parts with wet hands! Disconnect the system from mains before starting work on electrical parts of the system. Have qualified experts replace damaged cables immediately.
Danger due to mechanical energy! System parts may be subject to overpressure. Danger of injury and damage to property due to es­caping water and unexpected movement of system parts. Check pressure pipes regularly. Depressurise the system before starting repair or maintenance work on the system.
Hazardous to health due to contaminated drinking water! The system may only be installed by a specialist company. The operation manual must be strictly adhered to! Ensure that there is sufficient flow. The pertinent guidelines must be followed for starting-up after extended periods of standstill. Inspections and maintenance must be performed at the intervals specified!
Note: By concluding a maintenance contract, you ensure that all of the required tasks are performed on time. You may perform the inter­im inspections yourself.
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
7
Deferrisation
GENO-mat FE-Z Deferrisation System
4 | Shipping and storage
Caution! The system may be damaged by frost or high tempera-
tures. In order to avoid damage of this kind:
Protect from frost during transportation and storage! Do not install or store the system next to objects which radiate a lot of heat.
The system may only be transported and stored in its original pack-
ing. Ensure that it is handled with care and placed the right side up (as indicated on the packing).
5 | Disposal
5.1 Packaging
5.2 Product
Comply with the applicable national regulations.
Dispose of the packaging in an environmentally sound manner.
If this symbol (crossed out waste bin) is on the product, Euro­pean Directive 2012/19/EU applies to this product. This means that this product and the electrical and electronic components must not be disposed of as household waste.
Find out about local regulations on the separate collection of electrical and electronic products.
Use the collection points available to you for disposing of your product.
For information on collection points for your product, contact your municipality, the public waste disposal authority, an au­thorised body for the disposal of electrical and electronic prod­ucts or your waste collection service.
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
8
Deferrisation
GENO-mat FE-Z Deferrisation System
B Basic information
1 | Laws, regulations, standards
In the interest of good health, rules cannot be ignored when it comes
to the processing of drinking water. This operation manual takes into consideration the current regulations and stipulates information that you will need for the safe operation of your deferrisation system.
Among other things, the regulations stipulate that
only approved companies are permitted to make major modifica-
tions to water supply facilities.
and that tests, inspections and maintenance on installed devices
are to be performed at regular intervals.
2 | Intended use/field of application
The GENO-mat FE-Z deferrisation systems are used for the oxida-
tion of dissolved iron in the raw water. The systems are used for pri­vate water supply plants up to maximum values of 3.0 mg/l of iron. If the systems are applied and operated according to the instructions, pure water values with a concentration of less than 0.1 mg/l of iron can be obtained.
The following requirements must be observed in order to obtain op­timum results:
Hydrogen sulphide and oil may not be detected in the water to be
deferrised.
Organic compounds should preferably not be contained in the
water; however, the maximum allowable value is 4 to 5 mg/l above the COD.
The oxygen concentration should be proportionally 15 % of the
existing iron concentration and the pH value must be higher than
7.0.
However, should ammonium (> 0.1 mg/l) be detected in the raw
water, an additional treatment step is required.
Should humic acids be contained in the well water, the pure wa-
ter quality to be expected might be affected.
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
9
Deferrisation
GENO-mat FE-Z Deferrisation System
3 | Function
3.1 Filters
3.2 Backwashing
3.3 First filtrate
The GENO-mat FE-Z deferrisation systems for the removal of iron work with an active insoluble catalytic filter material. A central control valve automatically controls the operating cycle’s filtration, backwash and first filtrate.
The raw water enters the exchanger tank via the raw water inlet and flows through the catalytic filter material from top to bottom. Thus the reaction of the oxygen with the iron contained in the water is accel­erated.
Bivalent iron is transformed into insoluble, filterable, trivalent iron (adding air sparingly might be required in order to improve the oxida­tion process). The filtered pure water is then directed via the lower distributing nozzle and the rising pipe through the pure water outlet into the piping system.
During the backwash process, the filter bed is forcibly flushed from bottom to top and thus loosened up. Impurities retained during the filtration process are washed out via the drain outlet at the control valve. The GENO-mat FE-Z deferrisation system must be back­washed every 6 days at the latest (for the setting refer to chapter F).
By an automatic switch-over of the central control valve, the filter bed will forcibly be flushed from top to bottom. This first filtrate is discharged to the drain and afterwards the deferrisation system is ready for operation once again.
3.4 Regeneration/ disinfection
3.5 Control unit
For operating and hygienic reasons, the deferrisation system must be regenerated every 6 months with the special granulate GENO­Spezialgranulat or GENO-oxi plus.
The GENO-mat FE-Z deferrisation systems are time-controlled via an electrical timer.
In order to properly use the automatic timer control, the time interval between two filter sequences (backwash interval in days) must be set.
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
10
Deferrisation
GENO-mat FE-Z Deferrisation System
C Product description
1 | Type plate
The type plate is located on the GENO-mat FE-Z control valve. Que-
ries and orders will be processed faster if you are able to provide the information listed on your system's type plate. Please copy the indi­cated information to the table below in order to have it readily avail­able whenever necessary.
GENO-mat FE-Z Deferrisation system
Serial number:       /
Order no.:      
Fig. C-1: Type plate GENO-mat FE-Z deferrisation system
Order no. 025 153 940-inter Edited by: nkes-mrie G:\BA-153940-INTER_025_GENO-MAT_FE-Z.DOC
11
Loading...
+ 24 hidden pages