SPUN SEDIMENT FILTER FOR EXTREME
DIRT FILTERING CAPACITY
COCONUT CARBON BLOCK
PATENTED METAL HOUSING
AUTO SHUTOFF VALVE
w/HIGH FLOW
MEMBRANE
EZ HOOKUP KIT
WALL MOUNTABLE
USES 50% LESS WATER
THAN TRADITIONAL RO SYSTEMS
NO ADDITIONAL PRE-FILTERS NEEDED
MEMBRANE FLUSH KIT OPTIONAL
Built in the U.S.A.
No Assembly Required
THE EX SERIES
The EX Series is designed to ow between 4 and 17 GPH, (Gallons Per Hour) at almost 0 ppm RO
water, with a 2:1 waste ratio. It’s aordable and durable, packed with features you would expect from
a higher priced unit. It outows all other RO’s in its class, with all the quality you would expect from a
GrowoniX product.
2
GROWONIX EX SERIES ACCESORIES
GXM INDUSTRIAL MEMBRANES
GrowoniX brought these to our
industry rst. A single High Flow
Membrane able to produce 200 GPD
at a 2:1 ratio. Get that water owing
and th e pp m d own with th e G row oni X
GXM line of High Flow Membranes!
Flow Rate: 150 gpd high ow
membrane
DOW Membrane replacement
for EX100/200/400,
GX150/200/300/400, and most
other brands of RO lters. Ultra high
rejection for the purest water. Great
for drinking water.
Flow Rate: 200 gpd high ow
membrane
Membrane replacement
for EX100/200/400,
GX150/200/300/400, and most other
brands of RO lters.
UV STERILIZATION
Stainless steel ultraviolet ltration to
remove 99.9% of micro- organisms
in your water supply. A must for well
water treatment, whole house lter
systems, or anytime water will be
stored.
FLOAT VALVE
Simple and easy to install. Each valve
comes with 1/4" and 3/8" QC ttings.
Valves are adjustable to allow for
installation in a multitude of tank
styles.
BP-1530
This little pump will raise the input
water pressure to 78psi on every
reverse osmosis lter from the
EX100 though the GX600—amazing
little pump. Adjustable output
pressure, designed for continuous
duty, and armed with overheat
protection,. Built in high pressure
cuto allows for easy use with oat
valves or faucets. 12000 hours of
brush life makes this little pump an
industry standard workhorse.
RM - INLINE
Calcor bed infuses ltered RO
water with calcium and magnesium,
slightly raising the pH and creating
mineralized drinking water.
ALKALINE CARTRIDGE
Nine stage lter includes Calcor,
negative ion emitting ceramics, and
kdf 85. Infuses ltered RO water with
minerals and ions, raising the pH to
approximately 9.5-10.5—creating
mineralized alkaline drinking water.
SEDIMENT SPUN
Spun polypropylene: A true multistaged depth lter utilizing separate
l a ye r s of m i c r o n l t r a t i o n . C o n s t r u c t e d
spun polypropylene, these lters oer
superior dirt holding capacity at an
extremely economic price. Great lter
for changing frequently, especially in
well water applications, or with use in
GrowoniX scrubbers.
SEDIMENT PLEATED
KDF85/CATALYTYIC CARBON FILTER
High ow pleated Sediment lter: This
is a washable, reusable, and durable
sediment lter with very low pressure
drop. Bacte r i a and c h e m ical r e s i s tant.
Great for high ow applications
and extended time between tler
changes. Comes standard in most
GrowoniX water lters.
KDF/CAT. Bacteriostatic media
controls growth of microorganisms.
Good for water soluble metals
removal, chlorine, chloramine, and
scale. Highly reactive catalytic
carbon, extremely porous and long
lasting, layered with a bed of KDF85.
– Our best carbon lter –
Durability, Reliability, Eciency, Purity, and Conservation form the foundation on which we design
and build all of our products. Consistent and superior quality sets us apart from other manufacturers
and increases our value to you - our customer. Whether you are a hydroponics hobbyist, serious
enthusiast, or large-scale gardener, GrowoniX is committed to bringing you the best solution for
water purication systems.
WHAT IS REVERSE OSMOSIS?
Reverse osmosis (RO) is a ltration method that removes many types of large molecules and ions
from solutions by applying pressure to the solution when it is on one side of a selective membrane.
This ltering process ensures that the solute (waste water) is contained within the pressurized
chamber while the pure solvent (RO water) is allowed to pass freely through the membrane.
TUNED FOR GROWING - IN TUNE WITH OUR CUSTOMERS
Traditional RO systems have waste ratios of approximately 4:1, which means there are 4 gallons
of waste water produced for every 1 gallon of puried water. GrowoniX line of water lters achieve
waste ratios of 2:1 with the EX100 through GX400 and an astounding 1:1 ratio with the GX600 and
GX1000.
GrowoniX has created a complete product line that will address the needs of hydroponic operations
of all sizes. Our lters will signicantly reduce your water use while dramatically increasing your yields.
THE TRADITIONAL WAY
takes 4 gallons of waste water to produce 1 gallon of pure water
THE
GrowoniXWAY
4
PRECAUTIONS
• Do not use unit with inlet water pressure exceeding 80 psi. If inlet water pressure is too high,
install water pressure regulator before the unit. Regulators and pressure limiters are available at
www.Growonix.com or your local plumbing supply.
• Keep unit away from direct light.
Direct light can cause algae and other biologicals to grow inside of the lter housings.
• Do not install unit near electrical outlets or electrical devices.
• Do not install in places where a leak can cause damage.
• GrowoniX EX Series RO water lters are rated using supply water that is 77°F, 475ppm, at 70psi.
Slower performance may be noted in areas with colder temperatures, higher water salinity, or
lower inlet water pressure.
• A minimum of 40psi is recommended to operate GrowoniX water lters. If your inlet water
pressure is too low, booster pumps can be used to increase pressure.
Pumps are available at www.Growonix.com.
• Do not use a ow restrictor other than the one included with your unit.
• Flow restrictors help tune the unit for proper waste ratio.
• Using bigger ow restrictors, or using the unit in areas with exceptionally dirty water,
REPLACEMENTS FOR ALL WATER FILTERS 400 GPD AND UNDER
SF-2510-PLSediment PleatedEX100/200/400/400-Tall, GX200/300/400, Mini Scrub14.50Depends on feed water piping/supplyStock on GX Series
SF-2510-SPSediment SpunEX100/200/400/400-Tall, GX200/300/400, Mini Scrub10.75Depends on feed water piping/supplyStock on EX Series
CF-2510-CCEconomy Coco CarbonEX100/200/400/400-Tall, GX200/300/400, Mini Scrub12.00
CF-2510-GBGreen CarbonEX100/200/400/400-Tall, GX200/300/400, Mini Scrub16.50
CF-2510-KDFPremium CarbonEX100/200/400/400-Tall, GX200/300/400, Mini Scrub39.008,000 Gallons Total 2,700 Gallons RO WaterMust for well water and chloramine removal
GXM-100Standard Membrane100+ GPD membrane for EX10083.00Depends on feed water qualityFits most other RO systems
GXM-200-HF
BP-1530Booster PumpBooster pump for all RO systems 600 GPD and under.227.00 12,000 Hrs brush lifeBooster pump for all RO systems 600 GPD and under
High Flow Cold Water
Membrane
200+ GPD High Flow Cold Water Membrane for EX100/200/400/400-Tall,
GX200/300/400
REPLACEMENTS FOR EX400HF-TALL AND SLIMSCRUB
SF-2520-SPSediment SpunEX400-tall, Slim Scrub10.75Depends on feed water piping/supply
99.00Depends on feed water qualityFits most other RO systems
16,000 Gallons Total
5,300 Gallons RO Water
17,000 Gallons Total
5,700 Gallons RO Water
34,000 Gallons Total
17,000 Gallons RO
Stock on EX Series
Stock on GX Series
Must for well water and chloramine removal
Must for well water and chloramine removal
7
INFORMATION ON QUICK CONNECT FITTINGS
O-RING
COLLET
TUBING
GROWONIX WATER FILTERS USE QUICK CONNECT FITTINGS
THAT ALLOW FOR EASY MAINTENANCE.
MAKE A CLEAN TUBE CUT
Cut the tube squarely and if using plastic tubing, ensure that the cut has not made the tube out of round.
Also ensure that the tube has a smooth outside diameter without any burrs or score marks
prior to inserting it into the tting
INSERT TUBE INTO FITTING
Push the tubing through the collet and dual o-rings until it bottoms out against the tube stop.
The collet holds the tube in place and the dual o-rings provide a leak resistant seal.
.
TEST AND INSPECT
Push and pull the tubing toward and away from the tting to ensure that it has been installed properly.
Test and inspect the installation for any leaks.
TUBE REMOVAL
Relieve pressure from the tubing and tting. Push uniformly around the collet ange against the
tting body while pulling the tubing away from the tting to release it.
• The EX100, EX200, & EX400 water lters are designed to be used with
between 40-80 psi of incoming water pressure.
• High Flow Membranes can work with as low as 20 psi of incoming water pressure.
• Do not exceed 80 psi of incoming water pressure. If incoming water pressure is too high,
install pressure regulator before unit. Pressure regulators are available at www.GrowoniX.com
• Always turn incoming water pressure on slowly, allowing all air to be discharged
before full water pressure is restored.
1
Connect 3/8” white supply tubing to
the inlet tting, making sure inlet seats
all the way in quick-connect tting.
This is the supply water line.
3
2
Connect 1/4” white RO tubing to the
auto shut-o valve, making sure RO
tubing seats all the way in quickconnect tting.
This is the ltered RO water out line.
4
Connect the 1/4” black drain tubing
to the ow restrictor.
Mount drain clamp to available drain
pipe. Connect other end of drain tubing
to included drain clamp.
11
FLUSHING THE EX100 KDF85 CARBON FILTER
Growonix water lters can be upgraded with a KDF85 Catalytic Carbon Pre-Filter. The "KDF"
carbon lter is a superior blend of highly reactive catalytic carbon and KDF85 process media used to
remove/reduce iron, hydrogen sulde, chlorine, chloramine, bacteria, scale, and algae.
The catalytic carbon in these lters is in a loose form, and thus will discharge a small amount of
carbon dust upon initial startup. It is recommended to unhook the membrane input side and ush
ten gallons of water through the carbon lter before re-connecting to the RO membrane. This will
ensure no dust gets into the membrane causing premature fouling.
12
Make sure incoming feed water is
shut o, ensuring the RO lter is
depressurized.
Disconnect the 1/4" white tubing that
feeds the membrane input from the
carbon lter.
3
Reconnect tubing to membrane input
and resume normal lter operation.
Hold tubing over sink or bucket.
Slowly turn on incoming water pressure,
allowing 5 gallons of water to ush
through the carbon lter.
Once ushed, turn o incoming feed water.
12
FLUSHING THE EX400/400-T KDF85 CARBON FILTER
THE EX400 AND EX400-TALL HAVE TWO RO MEMBRANES
IT IS NECESSARY TO DISCONNECT BOTH MEMBRANE FEED LINES
**
TO PROPERLY FLUSH THE CARBON FILTER.
12
Make sure incoming feed water is
shut o, ensuring the RO lter is
depressurized.
Disconnect both 1/4” white lines that
feed both membranes’ input from the
carbon lter.
3
Reconnect tubing to membrane input
and resume normal lter operation.
Hold tubing over sink or bucket.
Slowly turn on incoming water pressure,
allowing 5 gallons of water to ush
through the carbon lter.
Once ushed, turn o incoming feed water.
Pre-lters should be changed when either brown discoloration occurs,
•
or system ow rates have signicantly declined.
• Always turn incoming water pressure o before servicing the unit.
• Always turn incoming water pressure on slowly, allowing all air to be discharged
before full water pressure is restored.
12
Unscrew sediment and carbon lter
housings using supplied lter wrench.
Wash inside of lter housings to
remove debris.
3
When replacing lter housings, make
sure housing O-rings are seated
properly. O-rings function best when
lubricated with food grade silicone
lubricant.
SedimentCarbon
Install new sediment and carbon lter,
making sure they go into the correct
lter housings.
4
Tighten lter housings by hand, do not
use lter wrench. Do not over tighten.
14
REPLACING MEMBRANE ELEMENT
2
IMPORTANT TIPS:
• The EX400 has 2 membranes;
repeat the following steps for
each membrane.
• Membranes should be
replaced when system output
signicantly declines. Note:
system output may decline due
to other factors as well
(SEE: TROUBLESHOOTING)
1
Input tube
Disconnect input tube(s) from RO
membrane housing.
3
Unscrew membrane housing end cap.
Caps can be dicult to remove. Be sure
to have a rm grip on opposite side of
housing . Do not lose O-ring on inside
of cap. Each cap has two O-rings.
4
Brine Seal
Insert new membrane into housing,
making sure the membrane-end with
the brine seal goes in last. Make sure
membrane is completely seated in the
housing.
Pull out membrane using needle nose
pliers or other similar tool.
5
Replace end cap and tighten by hand.
If O-rings are dry, lubricate with food
grade silicone lubricant. Allow system
to run for ½ hour before using RO
water.
GrowoniX water lters come with a manual ush valve. Flushing the membrane element after each
use for approximately 3-5 minutes will remove standing salts from the membrane, signicantly
extending membrane life. Even weekly ushes will improve membrane life and system performance.
12
Locate the Flow Restrictor
3
Let system run for 3-5 minutes.
Replace the Flow Restrictor
For a period of one year from the date of original purchase, we will replace or repair any part of the GrowoniX
reverse osmosis water system that we nd to be defective in operation du e to faulty materials or workmanship
with the EXception of the replaceable lters and membranes.
GENERAL CONDITIONS
Damage to any part of this reverse osmosis system because of misuse; misapplication; negligence; alteration;
accident; installation; or operation contrary to our instructions, incompatibility with accessories not installed
by GrowoniX, or damage caused by freezing, ood, re, or Act of God, is not covered by this warranty. In all
such cases, regular charges will apply. This limited warranty does not include service to diagnose a claimed
malfunction in this unit. This warranty is void if the claimer is not the original purchaser of the unit or if the unit
is not operated under normal municipal water or well water conditions.
GrowoniX assumes no liability in connection with this reverse osmosis system. GrowoniX assumes no liability
for any damages incurred through the use of this product. It is the responsibility of the end user to gauge the
safe use of this product in the environment where it is applied. We do not authorize any person or representative
to assume for us any other obligations on the sale of this reverse osmosis system. The information given out
in the manual we believe to be true, but are oered to you in good faith without guarantee because each
application of this product is dierent and beyond our control.
THE FOLLOWING STANDARD OPERATING CONDITIONS FOR RESIDENTIAL/COMMERCIAL REVERSE
OSMOSIS SYSTEMS MUST BE MET FOR WARRANTY TO BE VALID.
Water PressurepH RangeMaximum TDSWater Temp
Standard System40-80 psi
2-11
2000 ppm40-100 F
GROWONIX RETURN POLICY
MERCHANDISE RETURN DETAILS AND PROCEDURE:
If any merchandise was defective —we will refund the full purchase price upon receiving and reviewing the
merchandise returned in undamaged condition.
RMA NUMBER:
You must rst obtain a Return Merchandise Authorization (RMA) number from GrowoniX.com. Any products
sent to GrowoniX without an RMA number will not receive a refund and may be returned to the sender at their
expense.
All refund amounts will be based on the manufacturer’s warranty and GrowoniX return policy. Refunds will be
issued back using the payment method you used when you placed your order. Refunds take up to 3-5 business
days to process once we receive the return.
PACKAGING:
Please kindly re-pack the product in its original box, or a box of equivalent strength. The unit should be packed
in the same manner as it came to prevent damage in shipping. Please return everything that was in the original
box, including any free items if applicable. Be sure to drain out all water from wet systems and parts and wrap
them in plastic bags before packing.
RETURN TO:
We will provide you with an GrowoniX warehouse address for return merchandise when we issue the RMA number.
18
Loading...