1.1Documents use
1.2 Symbols Used
1.3 Glossary
Safe ty
2.1 Intended Use
Prod uct Descri ption
3.1 Gro wa tt U E ov er vi ew
3.2 Type label
3.3 Size and weight
3.4 Tran sp or ta ti on
Unpa cking
Index
1
2
3
4
2.2 Safety Prec au ti on s
Inst allation
5
5.1 Safety instruction
5.2 Selecting the Installation Location
2.3 Assembly Wa rn in gs
2.4 Electrical Connection War ni ng s
2.5 Operation War ni ng s
2.6 Symbols on the inverter
3.5 Storage of Inverter
3.6 The a dvant age of th e Growa tt U E inv erter s
5.3 Installation guide
5.4 Electrical Connections
5.5 Grid Type
Star t-Up and shu t down the in verter
7
7.1 Start-Up the inverter
7.2 Shut down the Inverter
Comm issionin g
6
6.1 Commission the Inverter
6.2 Operation Modes
6.3 Country Setting and LCD Display
6.4 M3 LCD Display
6.5 Double MPPT of the Grow at t UE
6.6 Communication
Main tenance an d Cleaning
8
8.1 Cleaning Fans and Grills
8.2 Exchange Fan
9.1 Error M es sa ge s di sp la ye d on L CD
Trouble s hoo ting
9
10 .1 Dismantling the Inverter
10.2 Packing the Inverter
Deco mmission ing
10
10.3 Disposing of the Inverter
Spec ificatio n
11
Cert ificates
PV sys tem instal lation
12
13
11 .1 Specification of Grow at t UE
11.2 DC connector info
11 .3 Torqu e Val ue s
11.4 Spare Pa rt s an d Ac ce ss or ie s
Cont act
14
Store this manu al where it w il l be accessible at all ti me s. We as su me no l ia bi li ty for
any d am ag e c au se d by fa il ur e t o ob se rv e t he se inst ru ct io ns . F or poss ib le ch an ge s in
this ma nu al , S HE NZ HE N G RO WATT NE W ENERGY TE CH NO LO GY CO ., LTD accepts n o
res po ns ib il it ie s to i nf or m th e us er s.
Information on this Manual 1
1.1 Do cuments us e
1.1. 2 Tar get G roup
1.1. 3 Storage of t he manual
This i ns ta ll at io n gu id e contains in st al la ti on , co mm is si on in g, communication, t rouble shooting. in fo rm at io n of Gro wa tt UE s er ie s in ve rt er s:
Grow at t 7000UE Growatt 80 00 UE Growatt 90 00 UE Growatt 10 00 0U E Growatt 12 00 0U E Growatt 18 00 0U E Growatt 20 00 0U E
This manual is for qualified persons who will operate, maintenance, service and rep ai re d in ve rt er s.
Wi th this i ns ta ll at io n g ui de , u se rs are ab le to i ns ta ll an d operate the in ve rt er s easily.T hi s manu al doe s not cove r any det ai ls con ce rn in g equi pm en t connected to the Gro wa tt U E. St or e th is m an ua l wh ere accessible at all times.
1.1. 1 Vali dity
1.1. 4 Addition al Informa tion
For further information on special topics in the download are a at w ww. gi nv er te r.com
1.2 Sy mbo ls Used
The following types of safety instructions and general information appear in this document as described below:
Symb ol desc ription
Read t he ma nual
DANGER
WAR NI NG
CAUTION
NOTICE
Informat io n
DANGER indicates a hazard ou s si tu at io n wh ic h, i f no t av oi de d, will re su lt i n de at h or s er io us i nj ur y.
WAR NI NG i nd ic at es a h az ard ou s si tu at io n wh ic h, i f no t av oi de d, could res ul t in d ea th o r se ri ou s in ju ry.
CAUTION indicates a hazardo us s it ua ti on w hi ch , if n ot a vo id ed , could res ul t in m in or o r mo de ra te i nj ur y.
NOTICE indicates a situation which, if not avoided, could res ul t in prop er ty d am ag e.
Information that you must rea d an d kn ow t o en su re o pt im al operation of the system.
1.3 Gl ossary
AC
Abbre vi at io n fo r "A lt er nating Curre nt "
DC
Abbre vi at io n fo r "D ir ec t Cu rrent"
Ener gy
Energy is measure d in W h (w at t ho ur s) , kW h (k il ow at t ho ur s) o r MW h (m eg aw at t hours).
1
2
Powe r
Power is measured i n W (w at ts ), k W (k il ow at ts ) or M W (m eg aw at ts ). P ow er i s an instantaneous value. It displays the power your inverter is curre nt ly f ee di ng i nt o th e power distribution grid.
Powe r rate
Power rate is the radio of curren t po we r fe ed in g in to t he p ow er d is tr ib ut io n gr id a nd the maximum power of the inverter that can feed into the power distribution grid.
Powe r Fac tor
Power factor is the ratio of true power or watts to apparen t po we r.
PV
Abbreviation for photovoltaic
Wire less commu nication a ccessori es (option al)
The extern al w ireless communication technology is a radio technology that allows the inverter and other communication prod uc ts t o co mm un ic at e wi th e ac h ot he r.
Safety 2
2.1 In tended Use
Gro wa tt U E se ri es i nv er te rs a re t o be u se d so le ly t o fe ed s ol ar e ne rg y co nv er te d photovoltaically into the public grid. Grow at t UE s er ie s in ve rt er s ar e mu lt i- st ri ng inverters with multi-MPP trackers, which mean they are ab le t o co nn ec t to d if fe rent PV module arrays. The equipment may only be operated in compliance with its intended use.
Grid-tied PV system Overview:
The in ve rt er ma y only be op er at ed wi th a pe rm an en t c on ne ct io n to th e p ub li c p ow er grid. T he inve rt er is n ot inte nd ed for mobile use. A ny othe r or addi ti on al use is not considere d as in te nd ed use . The manu fa ct ur er is not responsible for any damages res ul ti ng fro m u ni nt en de d use. Da ma ge ca us ed b y s uc h unintended us e i s at th e sole risk of the operator.
As drawings shown above, a complete Grid-tied PV system consists of PV modules, PV inverters, public grid and other components. Moreo ve r, PV inverters always act as key components.
When design a PV system contains Grow at t UE s er ie s in ve rt er s or a ny o th er G ro wa tt inverters, the system designing software Sh in eD es ig n (d ow nl oa d fr om s it e: www.ginverter.c om ) wi ll p rovide adequate supports.
PV mod ules Capac itive Disc harge Curr ents
PV modules with large capacities re la ti ve t o ea rt h, s uc h as t hi n- fi lm P V mo du le s wi th cells on a metallic substrate, may only be used if their coupling capacity does not exceed 470nF. Dur in g fe ed -i n op er at io n, a l ea ka ge c ur re nt f lo ws f rom the cells to earth, the size of which depends on the manner in which the PV modules are in st al le d (e.g. foil on metal roo f) a nd o n th e we at he r (r ai n, s no w) . Th is " no rm al " le ak ag e curre nt m ay n ot e xc ee d 50 mA d ue t o th e fa ct t ha t th e in ve rt er w ou ld o th er wi se automatically disconnect from t he e le ct ri ci ty g ri d as a p ro te ct iv e me as ure.
Fig1.1
3
4
Informat io n
If PV modules of the PV system re qu ir e PO SI TI VE o r NE GATIVE to connect to GROUND, or the capacitance rel at iv e to g ro un d of the modules is large, please contact Grow at t Ne w En er gy f or technical support before in st al la ti on .
2.2 Sa fety Preca utions
The GROWATT UE series Inverters are d es ig ne d an d te st ed a cc or di ng t o in te rn at io na l safety re qu ir em en ts ; ho we ve r, cer ta in s af et y pr ec au ti on s mu st b e ob se rv ed w he n installing and operating this inverter. Re ad a nd f ol lo w al l in st ru ct io ns , ca ut io ns a nd warn in gs i n th is i ns ta ll at io n ma nu al . If q ue st io ns a ri se , pl ea se c on ta ct G rowatt's technical services at +86 755 2747 1900.
2.3 As sembly Warni ngs
CAUTION
WAR NI NG
Prior to installation, inspect the unit to ensure a bs en ce o f an y transport or handling damage, which could aff ec t in su la ti on integrity or safety clearances; failure t o do s o co ul d re su lt i n sa fe ty hazards .
Unauthorized re mo va l of n ec es sa ry p ro te ct io ns , im proper use, incorre ct i ns ta ll at io n an d op er at io n ma y le ad t o se ri ou s sa fe ty, shock hazards o r eq ui pm en t da ma ge .
In orde r to m in im iz e th e po te nt ia l of a s ho ck h az ar d du e to hazardo us v ol ta ge s, c ov er t he e nt ir e so la r ar ra y wi th d ar k ma te ri al prior to connecting the array to any equipment.
Gro un di ng t he P V mo du le s: C om pl y wi th t he l oc al r eq ui rements for gro un di ng t he P V mo du le s an d th e PV g en er at or. Gro wa tt r ec om me nd s co nn ec ti ng t he g en er at or f ra me a nd o th er
electrically conductive surfaces in a manner which ensure s continuous conduction and gro un d th es e in o rd er t o ha ve o pt im al pro te ct io n of t he s ys te m an d pe rs on ne l.
2.4 El ectrical C onnectio n Wa rni ngs
DANGER
Some components in the inverter are l iv e. Tou ch in g li ve c om po ne nt s can res ul t in s er io us i nj ur y or d ea th .
Danger to life due to high voltages in the inverter All work on the inverter may be carried out by qualified personnel
only. The appliance is not to be used by children o r pe rs on s wi th
red uc ed p hy si ca l, s en so ry o r me nt al c ap ab il it ie s, o r la ck o f experience and knowledge, unless they have been given supervision or instruction.
Childre n ar e fo rb id de n to p la y around the Grow at t in ve rt er.
WAR NI NG
Make all electrical connections (e.g. conductor termination, fuses, PE connection, etc.) in accorda nc e wi th p re va il in g regulations. When working with the inverter powere d on , ad he re t o al l pre va il in g sa fe ty r eg ul at io ns t o mi ni mi ze r is k of a cc id en ts .
The Gro wa tt U E se ri es i nv er te rs m ay o nl y be o pe ra te d wi th P V generators (modules and cabling) with pro te ct iv e in su la ti on . Do n ot connect any sourc e of e ne rg y ot he r th an P V mo du le s to t he G ro wa tt UE series.
Systems with inverters typically re qu ir e ad di ti on al c on trol (e.g., switches, disconnects) or pro te ct iv e de vi ce s (e .g ., f us in g ci rc ui t bre ak er s) d ep en di ng u po n th e pr ev ai li ng s af et y ru le s.
Please re ad t hi s ma nu al c ar ef ul ly, th e ma nu fa ct ur er o r su pp li er i s not res po ns ib le f or d am ag e ca us ed b y in co rr ec t op er at io n, installation, wiring, transport, etc.
CAUTION
House grid:
Public grid:
Energy flows into the house grid. The consumers connected, for example, household devices or lighting, consume the energy. Th e en er gy l ef t ov er i s fe d in to t he p ub li c gr id . Wh en the Gro wa tt U E se ri es i nv er te rs d o no t ge ne ra te a ny e ne rg y, e.g., at night, the consumers which are c on ne ct ed a re s up pl ie d by the public grid. The energy displayed on the LCD of inverter is for re fe re nc e on ly. Wh en e ne rg y is f ed i nt o th e pu bl ic g ri d, the energy meter spins backward s.
Energy is fed direc tl y in to t he p ub li c gr id . Th e Gr ow at t UE series inverters need install a separate energy meter. The energy prod uc ed i s co mp en sa te d at a r at e de pe nd in g on t he electric power company.
2.5 Op eration Warn ing s
WAR NI NG
Ensure al l co ve rs a nd d oo rs a re c lo se d an d se cu re during operation. Although designed to meet all safety re qu ir em en ts , so me p ar ts a nd
surfaces of Inverter are st il l ho t du ri ng o pe ra ti on . To red uc e th e ri sk of injury, do no t to uc h th e he at s in k at t he b ac k of t he P V-I nv er te r or nearby surfaces while Inverter is operating.
Incorre ct s iz in g of t he P V pl an t ma y re su lt i n vo lt ag es b ei ng p resent which could destroy t he i nv er te r. The inverter display will rea d th e error m es sa ge “ P V Vol ta ge H ig h ”
Turn t he r ot ar y sw it ch o f th e DC D is co nn ec t to t he O ff position immediately.
Contact installer.
The Gro wa tt i nv er te r is t o be u se d so le ly t o fe ed s ol ar e ne rg y converted photovoltaically into the public grid. The inverter is suitable for mounting indoors and outdoors.
You ca n us e th e AC c ur rent generated as follows:
5
6
All operations re ga rd in g tr an sp or t, i ns ta ll at io n an d st ar t- up , including maintenance must be operated by qualified, trained personnel and in compliance with all prev ai li ng c od es a nd reg ul at io ns .
Anytime the inverter has been disconnected from t he p ow er network, use extrem e ca ut io n as s om e co mp on en ts c an r et ai n charge suff ic ie nt t o cr ea te a s ho ck h az ard; to minimize occurren ce of such conditions, comply with all corre sp on di ng s af et y sy mb ol s and markings pres en t on t he u ni t an d in t hi s ma nu al .
In special cases, there m ay s ti ll b e in te rf er en ce f or t he s pe ci fi ed application are a de sp it e ma in ta in in g st an da rd iz ed e mi ss io n li mi t values (e.g. when sensitive equipment is located at the setup location or when the setup location is near radio or television rec ei ve rs ). In t hi s ca se , th e op er at or i s ob li ge d to t ak e pr op er a ct io n to re ct if y th e si tu at io n.
Possible damage to health as a re su lt o f th e ef fe ct s of r ad ia ti on ! Do not stay closer than 20 cm to the inverter for any length of time.
CAUTION
Symb ol Expl anation
Electrical voltage!
Risk of burn s!
Point of connection for gro un di ng p ro te ct io n.
Direc t Cu rr en t (D C)
Altern at in g Cu rrent (AC)
CE mark. The inverter complies with the re qu ir em en ts o f th e ap pl ic ab le E C
guidelines.
Product Description 3
3.1 Gr owatt UE ove rview
Position
Descript io n
A
LCD
B LED
C
PV input ter mi na ls
D
DC Switch
E
AC output
F
RS232 lid
G
RS485
H
Series Num be r
I
War ni ng L ab el
J
Type label
2.6 Sy mbols on the i nverter
7
8
Operation after 5 minutes
Symb ol Desc rip tion Expl ana tion
Tap sym bol
NORMALL
FAULT
Ind icate s displ ay oper ation ( see Sec tion 6) .
Inv erter s tate sy mbol
Gre en /c on st ant
Red /cons tant
Red /flas hing
Ope ratio n
1Fau lt– con tact in stall er 2Sta ndby mo de 1Fan s Fault -- cont act ins talle r 2Sof tware u pd at e
3.2 Type la bel
The type labels pro vi de a u ni qu e id en ti fi ca ti on o f th e in ve rt er ( Th e type of pro du ct , De vi ce -s pe ci fi c ch ar ac te ri st ic s, C er ti fi ca te s an d appro va ls ). T he t yp e la be ls a re o n th e ri gh t- ha nd s id e of t he enclosure .
The Certificate Number is just for SAA.
More de ta il a bo ut t he t yp e la be l as t he c ha rt b el ow :
Mod el Name
Max D C volta ge
Max i nput cu rrent
MPP v oltag e range
AC No minal v oltag e
AC gr id freq uency ; Ran ge
Max . AC outp ut powe r
Nom inal ou tput cu rrent
Max . outpu t curre nt
Pro tecti on Degre e
Ope ratio n tem perat urera nge
Gro wa tt7 000UE
100 0V
15A / 1 5A
300 V-1000 V
3/N / PE 230 V/400 V
50/ 60Hz
-6H z/+5H z
7KW
10. 2A
11. 7A
Ip6 5
-2 5°C ~ +60 °C
Gro wa tt8 000UE
100 0V
15A / 1 5A
300 V-1000 V
3/N / PE 230 V/400 V
50/ 60Hz
-6H z/+5H z
8KW
11. 6A
13. 3A
Ip6 5
-2 5°C ~ +60 °C
Gro wa tt9 000UE
100 0V
15A / 1 5A
300 V-1000 V
3/N / PE 230 V/400 V
50/ 60Hz
-6H z/+5H z
9KW
13. 1A
15A
Ip6 5
-2 5°C ~ +60 °C
3.3 Si ze and weigh t
Model Name
GROWATT
PV Grid Inverter
U
DC max
I
DC max
U
DC range
V
AC norm
f
AC norm
P
AC norm
I
AC norm
Protection Degree
Operation Ambient Temperature
xxxxxx
xxxxxx xxxxxx
xxxxxx
xxxxxx
xxxxxx
xxxxxx
xxxxxx
xxxxxx
xxxxxx
xxxxxxxxxxxxxxx
I
AC max
xxxxxx
VDE 0126-1-1, IEC 62109
RD 1663, G59, ENEL-Guide
PV INVERT ER
9
10
Mod el Name
Max D C volta ge
Max i nput cu rrent
MPP v oltag e range
AC No minal v oltag e
AC gr id freq uency ; Ran ge
Max . AC outp ut powe r
Nom inal ou tput cu rrent
Max . outpu t curre nt
Pro tecti on Degre e
Ope ratio n tem perat urera nge
Gro wa tt1 0000U E
100 0V
15A / 1 5A
300 V-1000 V
3/N / PE 230 V/400 V
50/ 60Hz
-6H z/+5H z
10K W
14. 4A
16A
Ip6 5
-2 5°C ~ +60 °C
Gro wa tt1 2000U E
100 0V
17A / 1 7A
300 V-1000 V
3/N / PE 230 V/400 V
50/ 60Hz
-6H z/+5H z
12K W
17. 5A
19A
Ip6 5
-2 5°C ~ +60 °C
Gro wa tt1 8000U E
100 0V
23A / 2 3A
300 V-1000 V
3/N / PE 230 V/400 V
50/ 60Hz
-6H z/+5H z
18K W
26A
28. 6A
Ip6 5
-2 5°C ~ +60 °C
Gro wa tt2 0000U E
100 0V
26A / 2 6A
300 V-1000 V
3/N / PE 230 V/400 V
50/ 60Hz
-6H z/+5H z
20K W
29A
32A
Ip6 5
-2 5°C ~ +60 °C
3.5 St orage of Inv erter
If you want to storage the inverter in your wareh ou se , yo u sh ou ld c ho os e an appro pr ia te l oc at io n to s to re t he i nv er te r.
The unit must be stored i n or ig in al p ac ka ge a nd d es ic ca nt m us t be l ef t in t he package. The storage temperature s ho ul d be a lw ay s be tw ee n -2 5an d +6 0. An d th e storage rel at iv e hu mi di ty s ho ul d be a lw ay s be tw ee n 0 an d 95 %. If there ar e lo ts o f in ve rt er s ne ed t o be s to red, the maximum layers for original carton is four. After long term storage, local installer or service department of GROWATT should perform a compreh en si ve t es t be fo re i ns ta ll at io n
Informat io n
After long term storage, the Real Ti me C lo ck o f th e in ve rt er maybe not corre ct , it w il l ca us e th e En er gy p ro du ce d to da y (E_day) error, you need to set the time and date, ref er t o 6. 3. 4 setting inverter time or 6.4.3 text line dsetting date and time.
3.6 Th e advantag e of the Growa tt UE invert ers
The feature s of U E in ve rt er a re b el ow : Dual independent MPP trackers Integrated DC disconnect switch Bluetooth/ RF technology/ Zigbee/ Wi fi Wi de P V vo lt ag e ra ng e18 0V ~1 00 0V The maximum eff ic ie nc y is 9 8% The Europ e ef fi ci en cy i s 97 .5 % IP65 enviro nm en ta l pr ot ec ti on Easy to install
Unpacking 4
Item
quantity
A
1
B 1
C
1
D*
6/8
Descript io n
E**
2
F
1
G
4
H
3
I***
2
--
1
--
1
Gro wa tt U E inverter Mounting f ra me
Wat er proo f co ve r
Explosio n sc rew
RS 485 conne ct or
Cable glan d fo r AC c on ne ct io n
M4 cros s re ce ss ed c ou nt ersunk head s crews M6 socket he ad c ap s crew s
485 termin al
War ra nt y( no t sh ow i n th e picture)
User manua l (n ot s ho w in t he p ic tu re )
Inf ormat ion
Though the packaging box of Gro wa tt U E is d ur ab le , pl ea se tre at t he p ac ki ng b ox g en tl y an d av oi d di sp os e th e pa ck in g bo x.
11
12
The i nvert er is tho rough ly t es te d an d inspe cted st rictl y befor e de li ve ry. Ou r in ve rt er s leave our f actor y in prop er e le ct ri cal and m echan ical co nditi on. Spe cial pa ckagi ng ensu res saf e and c arefu l tr an sp or tatio n. Howe ver, tra ns port dama ge may st ill occ ur. The sh ip ping com pany is r es po ns ib le in suc h cases . Thoro ug hl y in sp ec t the inv erter u pon del ivery. Imm ediat ely not ify the r es po ns ib le ship ping co mpany i f you dis cover a ny dama ge to the pac kagin g which i ndica tes tha t the inv erter m ay have b een dam aged or i f you dis cover any v isibl e damag e to the in verte r. We will be g lad to as sist yo u, if req ui red. Wh en tra nspor ting th e inver ter, the o ri ginal o r equiv alent p ackag ing sho uld to be u sed, an d the max imum la yers fo r origi nal car ton is fo ur, as thi s en sures s af e tr an sp ort.
A(mm ) B(mm ) C(mm ) D(mm )
Wei ght (kg)
7000-12000 UE
740 490 4 05 2 35 41
18000-20000 UE
740 570 4 85 2 35 60
3.4 Trans por tatio n
Fig4.1
Before op en in g th e pa ck in g bo x of G ro wa tt U E, p le as e no te t ha t wh et he r th ere are any visible extern al d am ag es .
Once open the packing box, please check the delivery for completeness and for any visible extern al d am ag es o f th e in ve rt er. If t he re a re anything damaged or missing, please contact your dealer. Co mp le te d el iv er y sh ou ld c on ta in a s fo ll ow s.
*Number of D is 6 for Gro wa tt 7 00 0U E- 12 00 0U E, a nd 8 f or G ro wa tt 18 00 0/ 20 00 0U E. **For type 1 RS 485
***For type 2 RS 485
Installation5
5.1 Sa fety instr uction
Danger to life due to fire or e xp lo si on Despite caref ul c on st ru ct io n, e le ct ri ca l de vi ce s ca n ca us e fi re s. Do not install the inverter on easily flammable materials and
where f la mm ab le m at er ia ls a re s to red.
Risk of burn s du e to h ot e nc lo su re parts Mount the inverter in such a way that it cannot be touched
inadvertently.
All el ec tr ical in st allat io ns s hall be d on e in acco rdan ce w ith the l oc al a nd nati on al e lectr ic al code s. D o no t re move th e ca si ng. Inv er ter con ta in s no user s er vi ceabl e pa rts. Re fe r se rvici ng t o quali fi ed s ervic e pe rsonn el . Al l wiri ng a nd e lectr ic al inst al la tion sh ou ld be con du ct ed by a qua li fied serv ic e pe rsonn el .
Carefull y re mo ve t he unit f ro m it s pa ckagi ng a nd insp ec t fo r exter nal dama ge . If y ou find a ny i mperf ec ti ons, pl ea se cont ac t yo ur loca l de aler.
Be sure that t he i nvert er s co nnect t o th e grou nd in order t o prot ec t pro perty a nd p erson al s af ety.
The in ve rt er must o nl y be oper at ed w ith PV ge ne rator. Do n ot conn ec t any ot he r so urce of ene rg y to i t.
Both A C an d DC v oltag e so urce s are termi na te d insid e th e PV Inve rt er. Plea se d is conne ct t hese ci rcui ts b efore servi ci ng.
This u ni t is d esign ed t o feed po we r to t he publ ic p ower gr id ( ut ility ) on ly. Do not c on ne ct this u ni t to an AC so urce o r ge nerat or. Conne ct in g Inve rt er t o exter nal dev ic es coul d resu lt i n serio us d am age to yo ur equi pm en t.
When a p ho to volta ic p anel is e xp os ed to lig ht , it gene ra te s a DC volt ag e. When c on ne cted to t hi s equip me nt , a photo vo ltaic p an el w ill cha rg e the DC lin k ca pa citor s.
Ener gy s to re d in this e qu ip ment' s DC l ink cap ac it ors prese nt s a ri sk of elec tr ic s hock. E ve n after t he u ni t is disc on necte d from t he g rid and phot ov ol taic pa ne ls, hig h vo lt ages ma y st ill exi st i ns ide the P V-I nvert er. Do not remov e th e casin g un ti l at leas t 5 mi nutes a ft er d iscon ne cting a ll powe r so ur ce s.
Alth ou gh d esign ed t o meet al l sa fe ty requiremen ts , some pa rt s an d surf ac es o f Inver te r are st ill hot d ur ing ope ra ti on. To reduce t he r is k of inju ry, do not to uc h th e heat si nk a t the bac k of t he P V-Inve rt er or nea rb y surf ac es w hile In ve rter is o pe ra ting.
5.2 Se lecting th e Installa tion Locat ion
11) No ti ce t he mini mu m clear an ce s of the in ve rter. (Re fer to 3. 3 Dime ns io ns and Fi g. 5.2 Req ui re d Cl earan ce s) .
This i s gu id ance fo r in stall er t o ch oose a su it able in st al latio n lo catio n, t o avoi d po te ntial d am ages to d ev ic e and ope ra tors.
1) The w al l se lecte d to i nstal l th e in verte r mu st be strong an d fi rm enou gh to sup po rt a nd bear t he w eight o f th e in verte r fo r a long pe ri od t ime. (Ref er t o Ch apter 1 1 Sp ecifi ca ti ons)
2) The l oc at ion sel ec ted mus t be s ui table f or i nvert er s' d imens io n. (Ref er t o
3.3 Di me ns ions an d Fi g.5.2 R eq ui re d Clear an ce s)
3) Do no t in st all the i nv erter o n st ru ctures co ns tr ucted o f fl ammab le o r ther mo l ab ile mat er ials.
4) Nev er i ns tall th e in verte r in e nv ironmen t of l it tle or no a ir f low, nor d us t envi ronm en t.
5) The I ng re ss P ro te ction r at e is IP65 w hi ch m eans th e in verte r ca n be inst al le d outdo or s and ind oo rs .
6) Do no t ex po se the in ve rter to d irec t su nligh t, i n or de r to avoi d th e po wer and effici en cy dera ti ng c aused b y ex cessi ve h ea ting.
7) The h um id ity of th e in stall at io n locat io n shoul d be 0 ~9 5% with ou t cond en sa tion.
8) The a mb ie nt temp er ature of the in ve rter sh ou ld b e -25~+6 0℃.
9) The i ns ta llati on l ocati on m us t be freely a nd s af ely to ge t at a ll time s.
10) Ver ti ca lly ins ta llati on a nd m ake sure th e co nn ectio n of i nvert er m us t be down wa rd s. N ever in st al l horiz on tal and a vo id s forwa rd a nd s id eways tilt .( R ef er to dra wi ngs bel ow )
Fig5.1
13
14
12) Do n ot i ns tall th e in verte r ne ar t elevi si on ante nn a or a ny othe r an tenna s and an te nn a cable s.
13) Do n ot i ns tall th e in verte r in l iv ing area, t he n oi se caus ed b y the mach in e ma y affect on d ai ly l ife.
14) Fo r se cu rity reas on s, d on't in st all the i nv er ter in pl ac e where the ch il dr en c an rea ch.
5.3 In stallati on guide
5.3. 1 Mou nting t he Br acket
DANGER
In orde r to a vo id e le ct ri ca l sh oc k or o th er i nj ur y, inspect existing electro ni c or p lu mb in g in st al la ti on s be fo re d ri ll in g ho le s.
F
i
x
t
h
e
i
n
v
e
r
t
e
r
w
i
t
h
M
6
s
c
r
e
w
F
i
x
t
h
e
b
r
a
c
k
e
t
w
it
h
M
1
0
*
9
0
e
x
p
a
n
s
i
o
n
b
o
l
t
F
i
x
t
h
e
b
r
a
c
k
e
t
w
i
t
h
M
1
0
*
9
0
e
x
p
a
n
s
i
o
n
b
o
l
t
F
i
x
t
h
e
i
n
v
e
r
t
e
r
w
i
t
h
M
6
s
c
r
e
w
a)b racke t of Grow at t 700 0UE-1 2000U E
b)b racke t of Grow at t 180 00UE/ 20000 UE
Fig5.3
15
16
Fig5.2
Hint: Data units in mm Steps:
5.3. 2 Mounting I nverter
WAR NI NG
Falling equipment can cause serious or even fatal injury, ne ve r mount the inverter on the bracket unless you are su re t ha t th e mounting frame is rea ll y fi rm ly m ou nt ed o n th e wa ll a ft er c ar ef ul ly checking.
After the bracket is firmly mounted on the wall, then mount the inverter on the bracket.
Rise up the Gro wa tt U E a li tt le h ig he r th an t he b ra ck et . Co ns id er in g th e we ig ht o f Gro wa tt U E, y ou n ee d to h an g on t he i nv er te r. During the proc es s pl ea se m ai nt ai n the balance of the Grow at t UE .
Hang the inverter on the bracket thro ug h th e ma tc h ho ok s on b ra ck et a nd t he back of the inverter.
Installed one M6*10 screw a t ea ch s id e of i nv er te r to r el ia bl e fi xe d it o n th e wa ll . Please re fe re nc e in F ig 5 .5 (b ).
Connection of a second prot ec ti ve c on du ct or. Please ref er en ce i n Fi g5 .6 . Recommend awning installation, the purpose is to extend the inverter service life
and red uc e th e po we r de ra ti ng o f th e in ve rt er. The dimension of the awning re fe r to Fig5.8.
Drill holes for screw s wh il e us e th e mo un ti ng f ra me a s te mp la te .6 h ol es f or Gro wa tt 7 00 0- 12 00 0U E an d 8 fo r Gr ow at t 18 00 0/ 20 00 0U E.
Fix the mounting frame on the wall as the figures s ho wn b el ow, c om bi ne a s th e screw s as t he I te ms F ig 4 .1 s ho ws ( it em s D)
Fig 5.5
Fig 5. 4
17
18
a)
b)
5.3. 3 Ins talla tio n layou t
Informat io n
Avo id e xp os in g in ve rt er t o di re ct s un li gh t, r ai n or s no w to e xt en d the inverter service life despite the IP65 prot ec ti on d eg re e. E xp os ure to the sunlight may cause additional inter na l he at in g wh ic h wi ll cause power derating.
Fig 5.8
Fig 5.6
More th an o ne i nv er te r ne ed t o be i ns ta ll ed , th e di me ns io ns b el ow s ho ul d be considere d.
>450mm
50 0 m m
1000mm
>400mm
Fig 5.9
19
20
5.4 El ectrical C onnectio ns
5.4. 1 Saf ety
DANGER
Danger to life due to lethal voltages! High voltages which may cause electric shocks are p re se nt i n
the conductive parts of the inverter. Pr io r to p er fo rm in g an y work on the inverter, di sc on ne ct t he i nv er te r on t he A C an d DC sides
WAR NI NG
Danger of damage to electro ni c co mp on en ts d ue t o el ec tr os ta ti c discharge.
Take approp ri at e ES D pr ec au ti on s wh en replacing and installing the inverter.
5.4. 2 W iring A C Out put
Conditions for the AC Connection
You mu st c om pl y wi th t he c on ne ct io n require me nt s of y ou r ut il it y op er at or. All usages must comply with the reg ul at io ns .
Residual-current protective device
The inverter is equipped with an integrated universal res id ua l- cu rr en t mo ni to ri ng unit.
If the network operator stipulates a re si du al -c ur re nt p rotective device, you must use a res id ua l- cu rr en t protective device that triggers in the event of a res id ua l- cu rr en t of 100 mA or more.
Connection of a second protective conductor
In some installation countries, a second prot ec ti ve c on du ct or i s re qu ired to pre ve nt a touch curre nt i n
the event of a malfunction in the original prot ec ti ve c on du ct or. For installation countries falling within the scope of validity of the IEC standard
62109, you must Install the pro te ct iv e co nd uc to r on t he A C te rm in al w it h a co nd uc to r cr os s- se ct io n of a t
least 10 mm²Cu. Or Install a second pro te ct iv e co nd uc to r on t he e ar th t er mi na l wi th t he s am e cr os s-
section as the original pro te ct iv e co nd uc to r on t he A C te rm in al
NOTICE
Please do not use single-core w ir e ca bl e.
The re are th ree t ypes of A C co nn ec to r fo r Gro wa tt U E se ri es in verte rs. Ple ase fol low the ins truct ions co rresp on di ng t o the par ts we off er y ou .
AC co nnect or 1: Ass embly p roced ur e:
1) Co nnect t he cabl es into t heir re sp ec ti ve chan nels, ' N' on the p ictur e re pre se nt s Neu tral ch annel ( marke d with '1 ' on the te rmina l), '1, 2,3' on t he pict ure rep res en t thr ee L iv e li ne chan nels (m arked w ith '2, 3,4' on t he term inal) , and GND o n the pic ture re pre sents G ro un d chann el (mar ked wit h on the te rmina l).
Load disconnection unit
You mu st i ns ta ll a s ep ar at e th ree-phase miniature c ir cu it -b reaker or other load disconnection unit for each inverter in ord er t o en su re t ha t th e in ve rt er c an b e sa fe ly disconnected under load.
Measure t he p ub li c gr id v ol ta ge a nd f re qu en cy ( Vol ta ge : 40 0Va c; F requency: 50Hz/60Hz; in 3-Phase); Open the brea ke r be tw ee n th e PV i nv er te r an d ut il it y; Specification of AC bre ak er : Gr ow at t 70 00 UE :1 6A /4 00 V Gro wa tt 8 00 0U E/ 9 00 0U E: 2 0A /4 00 V Gro wa tt 1 00 00 UE / 12 00 0U E: 2 5A /4 00 V Gro wa tt 1 80 00 UE / 20 00 0U E: 5 0A /4 00 V
Cable req ui re me nt s:
Mod el
Dia meter (mm) Are a( mm² ) Ava il abl e wire ga uge (AWG )
100 00UE
2.0 5~4.1 1 4~1 6 12~ 6
120 00UE
2.0 5~4.1 1 4~1 6 12~ 6
180 00UE
2.5 9~4.1 1 6~1 6 10~ 6
200 00UE
2.5 9~4.1 1 6~1 6 10~ 6
900 0UE
2.0 5~4.1 1 4~1 6 12~ 6
800 0UE
2.0 5~4.1 1 4~1 6 12~ 6
700 0UE
2.0 5~4.1 1 4~1 6 12~ 6
Con ducto r Cro ss s ect ion
Max . cable l ength (m)
6.0 m m²
10. 0 mm²
16. 0 mm²
Gro watt 100 00UE
48
72
105
Gro watt 120 00UE
40
60
88
Gro watt 180 00UE
27
40
59
Gro watt 200 00UE
25
36
53
AC co nnect or type Cond uct or cros s-sec tion (m m²) Str ippin g lengt h (mm)
Con necto r 1 4.0 -6.0 8
Con necto r 2 4. 0-6.0 8
Termi nal 3
6.0 -16.0 10
Gro watt 700 0UE
70
140
220
Gro watt 100 00UE
60
125
200
Gro watt 100 00UE
54
110
15
21
22
Loading...