Grosvenor Janus C4 Series, JC4-ADV-C2-MLT, JC4-ADV-C2-SNG Installation Manual

Janus C4 2-Door Blade
janus
Installation Guide
Part number:
JC4-ADV-BL-2D
C4
The Janus C4 2-Door Blade is a plug-in unit that can be purchased with either the Janus C4 Single-Blade Controller (Part No: JC4-ADV-C2-SNG) or the Janus C4 Multi-Blade Controller (Part No: JC4-ADV-C2-MLT).
Each 2-Door Blade enables the connection of two readers and two doors in Janus C4 access control systems.
Specication
Overview
Lock Switching Capacity
Card Reader interface
Card Reader Supply, power limited
Tamper, Door Sensor, Exit Switch, Aux, Inputs
Break Glass Input
Sounder, Valid, Invalid Output
Aux Out
External Lock Input Supply
Operating Temperature
Humidity
Weight
Dimensions
Electromagnetic Compatibility
This product complies with the following standards, following the provisions of EMC Directive 2014/30/EU:
 EN 55022:2010 Class B
Janus C4 2-Door Blade
12V/24V, 4A max (Solid State output, current limited)
Wiegand, Clock/Data, RS485
12V 500 mA, 5V 200 mA total (both ports)
5V pullup (2k2), max 12V in
24V max
500 max sink to GND (solid state), 12V max in
Isolated 30V, 300mA max, internally fused
24V max, 8A max. Must be externally fused
0 to +49°C (32 to 120°F)
5-85±5% at 30±2°C (86±4°F)
140 g
197 x 60 x 28 mm
WEEE
Please refer to www.grosvenortechnology.com/ legal-info/ for disposal instructions under EU Directive
2012/19/EU.
 EN50130-4:2011 inc A1:2014
 IEC 62599-2:2010
Page 1
Power Options
Input Power
The Janus C4 2-Door Blade draws 12V power from the controller. The 2-Door Blade power draw is summed as follows:
 2-Door Blade Quiescent Current = 83 mA max @12V
(1.0W)
 External Reader Current (200mA max @ 5V and/or
500mA max @ 12V)
 External Door Lock Current (= 4A max per Lock @
12V)
12V IN
(from Controller)
12V/24V
External Lock
Supply
Up to 8 Amp
Current & Voltage
Measure
Overload Protection
External Lock Supply
For systems with 24V door locks, or locks requiring more power than the controller can provide, the 2-Door Blade supports an external lock power supply. This operates
automatically if available, where the Blade will nd the
external lock power supply for the locks, otherwise, it uses internal power. This cannot be changed without
powering o󰀨.
External lock power is separate from the controller power. It will need an independent back-up if required: it is not supported by the controller battery.
Sounder 12V
Reader 12V
Reader 5V12V => 5V
Current & Voltage
Measure
Overload Protection
12V Lock 1
(4 Amp max)
Blade LED indicators
Status LED
The main Blade LED Indicator is used to indicate activity and state (see also the status LED on the controller).
If the LED is continuously red, the 2-Door Blade is not communicating with the controller.
Blade State is reported by ashing a code on the LED
every 15 seconds as follows:
5 blue ashes Board is not being monitored.
Probably no download to controller from Janus C4
5 red ashes Wrong device type congured, e.g.
a door is dened on an I/O Blade
3 red ashes Out of range device congured,
e.g. Input 3 dened when it only
supports 2
5 green ashes No devices congured for board
5 yellow ashes Reports electrical issues, such as
current tripped, over voltage, under voltage, over current, under current
Current & Voltage
Measure
Overload Protection
12V Lock 2
(4 Amp max)
Blade Activity is reported as follows:
Yellow icker (lasts
about 30 seconds)
Green blink (every 5
Firmware download in progress
Board running OK
seconds)
Blue blink Read
Yellow blink Input state change
Red blink Output state change
Other LED Indicators
There are three diagnostic red LEDs on a 2-Door Blade. Note that these LEDs cannot be seen when the controller and Blade are in the enclosure.
 LED2 – Lock 1 Power. This will be on if Door 1 on the
Blade has not been dened or if the Lock 1 power
current limit has been tripped
 LED3 – Lock 2 Power. This will be on if Door 2 on the
Blade has not been dened or if the Lock 2 power
current limit has been tripped
Page 2
 LED4 – Reader Power (includes other connections,
such as sounders). This will be on if the Blade has not
been dened or the current limit has been tripped
Loading...