Grohe Red Duo 30 058, Red Duo 30 153 Technical Manual

Page 1
D
.....1
I
.....5
N
.....9
GR
.....13
TR
.....17
.....21
.....25
GB
.....2
NL
.....6
FIN
.....10
CZ
.....14
SK
.....18
EST
.....22
CN
.....26
F
.....3
S
.....7
PL
.....11
H
.....15
SLO
.....19
LV
.....23
RUS
.....27
E
.....4
DK
.....8
UAE
.....12
P
.....16
HR
.....20
LT
.....24
Design + Engineering GROHE Germany
GROHE Red Duo
GROHE Red Duo
99.133.231/ÄM 230155/04.14
30 058 30 153
GB
.....1
I
.....5
N
.....9
GR
.....13
TR
.....17
.....21
.....25
DK
.....6
NL
.....6
FIN
.....10
CZ
.....14
SK
.....18
EST
.....22
CN
.....26
F
.....3
S
.....7
PL
.....11
H
.....15
SLO
.....19
LV
.....23
RUS
.....27
E
.....4
DK
.....8
UAE
.....12
P
.....16
HR
.....20
LT
.....24
Page 2
I
30 058
30 153
Please pass these instructions on to the end user of the fitting!
Page 3
II
1
13mm
*19 017
A
max.
60mm
max.
45mm
A
7
Ø8
22
24mm
31mm
G 1/2
G 3/8
31mm
24mm
B
B
9
C
10
8
10mm
4
Ø40
Ø32
5 6
3
min. 50
284
Page 4
1
GB
Type approvals
The GROHE Red boiling water storage heater
with filter
system must be installed the safety assembly with
expansion
vessel
provided.
The boiling water storage heater
with filter system
may only be operated together with an original GROHE Red boiling water fitting.
Application
The GROHE Red boiling water fitting supplies boiling water in addition to hot and cold tap water. Boiling and mixed water flows into the GROHE Red fitting through separate pipes and flows out through two separate areas of the flow straightener.
The GROHE boiling water storage heater is designed to heat and store drinking water in pressurised systems.
The GROHE boiling water storage heater is suitable for connection to a mains system with a maximum water pressure of 0.8 MPa.
It must not be connected to hot water. The filter system measures the flow rate using a sensor and
from this calculates the remaining capacity of the filter cartridge as a function of the set litre capacity. If the filter cartridge litre capacity set on the display unit is exceeded, the values are displayed as negative values.
The sensor also monitors the maximum service life of the filter cartridge. If the maximum service life of 12 months is exceeded, the remaining capacity of the filter cartridge flashes.
The water filtrate is classified as Category 2 according to EN 1717.
Safety notes
GROHE Red boiling water storage heater:
This device is not intended for use by persons (including children) with physical, sensory or mental impairments or a lack of experience or knowledge in using devices of this type.
Children must be supervised to ensure that they do not play with the device.
Risk of electric shock. Avoid damaged power supply cable. In case of damage, the boiling water storage heater must be replaced by the manufacturer or its customer service department or an equally qualified person.
Caution, risk of scalding! Escaping water is boiling hot. Never touch the end of the spout in order to swivel the spout as it becomes extremely hot.
•The boiling water storage heater must be connected to a permanent power supply with earth wire.
• Installation is only possible in frost-free rooms.
• The boiling water storage heater is only suitable for
indoor use.
• The boiling water storage heater must be placed in an
upright position.
• The boiling water storage heater and plug must not be
directly or indirectly sprayed with water when cleaning.
• The boiling water storage heater must not be opened.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty and the CE identification, and could lead to injuries.
If the boiling water storage heater is to be drained, the safety assembly
with
expansion vessel of the boiling water storage heater must be removed. Invert the boiling water storage heater and allow the water to run out.
However, we strongly advise against draining the boiling water storage heater. There is a significant risk of damaging the boiling water storage heater.
Technical data
Electrical data boiling water storage heater:
• Connection: Wall socket with earth wire, protected
via a 13 A fuse
• Voltage supply: 230 V AC / 50 Hz
• Power consumption: 2100 W
• Standby power loss (switched on): 15 W
• Standby power loss (switched off): 1 W
• Type of protection: IPX4
Filter system:
• Sensor battery: 3 V lithium battery (type CR 2032)
• Cable length: 1,500mm
• Display unit rating (wall installation): IPX4
• Sensor rating: IPX8
Sanitary data boiling water storage heater, fitting:
• Boiling water storage heater capacity: 4 l
• Flow pressure:
– min. 0.1 MPa – recommended 0.1 – 0.5 MPa
• Operating pressure: max. 0.2 – 0.8 MPa
• Test pressure: 1.6 MPa
• Flow rate at 0.3 MPa flow pressure
- Mixed water: approx. 6.8 l/min
- Boiling water: approx. 3.4 l/min
• Boiling water temperature 99 °C
The actual temperature may differ slightly due to different ambient pressures
• Heating time from 10 °C to 99 °C: approx. 15 min
• Available storage heater volume at 99 °C: 3 l/min
• Max. chlorine value: 100 mg/l
• Water connection at storage heater: Cold water
• Water connection at fitting: Cold water from service valve
Hot water from service valve
Boiling water from storage heater
New Water Regulations
Please ensure installation complies with New Water Regula­tions. It must also be installed in accordance with local bye-law requirements.
Approval and conformity
The conformity declarations can be obtained from the following address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9 D-32457 Porta Westfalica
This product conforms to the requirements of the relevant EU guidelines.
Page 5
2
Electrical installation
Electrical installation work must only be performed by a qualified electrician. This work must be carried out in accordance with the regulations according to IEC 60364-7-701 (corresponding to VDE 0100 Part 701) as well as all national and local regulations.
• Extension cables are not permitted between the electrical
socket and boiling water storage heater connection.
Installation
Refer to the dimensional drawing on fold-out page I. Installing fitting, see fold-out page II, Figs. [1] and [2].
Insert fitting in sink hole. This will require leading through the hoses one at a time.
Note: If there is no need to fit support plate (A), the clamping length may be increased by 15mm, see Fig. [1].
Mount safety relief valve kit to the waste pipe, see Figs. [3] to [6].
Mount wall holder, see Figs. [7] and [8]. Mount compression couplings (B) and tighten nipple, see
Fig. [9].
Fix expansion vessel (C) with safety assembly to the wall holder, see Fig. [10].
Connect filter head and filter, see technical product
information for the filter head and the filter cartridge and fold­out page III, Fig. [11]. Note direction of flow.
1. Install pressure hose (D) to the inlet of filter head.
2. Install sensor (E) at outlet of filter head. The sensor (E) must be installed horizontally.
3. Install display unit (F).
Use suitable screws and wall plugs (not included in the scope of delivery).
Connect filter system, see Fig. [12].
1. Connect adaptor (G) on the cold-water service valve.
2. Screw pressure hose (D) of filter system onto adapter (G).
3. Screw hose (H) onto sensor (E).
Connect storage heater, see Figs. [2] and [13]. Install storage heater taking into consideration the
available hose lengths. Do not connect voltage supply yet.
Flush pipes thoroughly before and after installation
(observe EN 806).
1. Connect expansion vessel (C), see Fig. [13].
2. Screw hose (H) to expansion vessel (C).
3. Screw storage heater pressure hose (I) marked blue to expansion vessel (C) using the seals provided.
4. Connect copper pipe (not in the scope of delivery) to the Ø15mm compression connection (J) of the expansion vessel (C) and tighten.
Connecting fitting, see fold-out page III, Fig. [14].
1. Screw fitting pressure hose (K) marked blue to adapter (G).
2. Screw red marked pressure hose (L) of the fitting onto the hot-water service valve.
3. Connect the fitting pressure hose (M) marked 99 °C to connection (N) on the storage heater.
Open the service valve and check connections for watertightness.
Filling storage heater with water, see Figs. [15] and [16].
1. Pull button (O1) on handle (O) of fitting outward and turn the handle anti-clockwise, see Fig. [15].
2. Fill the storage heater until water comes out the spout of the fitting.
3. Connect voltage supply via mains plug (P), see Fig. [16].
4. Press and hold button (Q) on storage heater for at least 2 seconds to switch on the storage heater. The red indicator lamp (Q1) indicates that the storage heater is switched on.
Important! The spout must not be fitted with any downstream
resistances in the form of air bubblers (e.g. mousseurs) or components reducing flow (e.g. restrictors) as these will result in damage to the storage heater.
Set water hardness at filter head, see fold-out page IV,
Fig. [17]. Set water hardness at bypass setting of filter head to local conditions, see table column A on page 4. The relevant water supplier can provide information on the water hardness. The bypass value setted to the filter head must also be set on the display unit (F), see Fig. [18].
Setting the litre specification (factory setting is 600 litre), see Fig. [18]. The value for the litre specification depends on the water hardness as per table column B on page 4:
The GROHE Red boiling water system is now fully installed and ready for operation.
Button Display
Briefly press PROG button (PRG flashes)
Briefly press RESET button to access programming for litre specification (00000 flashes)
Keep pressing PROG button until required position is reached (00000 digit flashes)
Keep pressing RESET button until required digit is reached (00600 digit flashes)
Keep pressing PROG button to exit menu (PRG disappears and set value appears)
The date of installation must be noted on the maintenance sticker and affixed at a visible location on the storage heater.
Page 6
3
Operating the fitting
Note:
In order to prevent incorrect operation and for protection against injury, we recommend affixing the sticker provided.
Open lever (R) to draw water, see fold-out page III, Fig. [15]. Pull button (O1) on handle (O) outward and turn and hold
handle (O) anti-clockwise to draw boiling water. Handle (O) closes automatically.
Press and hold button (Q) for at least 2 seconds to switch the storage heater on or off, see Fig. [16].
Maintenance
In the case of interventions in the mains supply or maintenance work, the GROHE Red boiling system must be bled as steam jets could otherwise occur.
Close the service valve, switch off the storage heater and disconnect the mains plug.
Wait until the storage heater and fitting have cooled down. Open the lever to depressurise the storage heater.
Inspect and clean all parts, replace as necessary and lubricate with special grease.
I. Filter
See technical product information of filter cartridge for information on replacing the filter cartridge.
Resetting the filter capacity at the display unit (F), see fold­out page IV, Fig. [18]. After a new filter cartridge is inserted, the filter capacity must be reset as follows:
Note: The litre specification programmed for the filter cartridge is retained.
Battery (F1), see fold-out page IV, Fig. [19] and [20]. The battery must be replaced 7 years after commissioning the fitting, at the latest.
1. Loosen screw (F2) and remove cover (F3), see Fig. [19].
2. Remove battery (F1) and replace, see Fig. [20].
Important: Note correct polarity.
Note: No settings saved by the user will be lost when
changing the batteries or if the battery discharges. Assemble in reverse order.
II. Cartridge (S), see fold-out page IV, Fig. [21].
1. Lever out plug (T) and remove set screw (U).
2. Remove lever (R) and cap (V).
3. Remove screw coupling (W) and take out cartridge (S).
Assemble in reverse order. When installing the cartridge (S), ensure that the seals are
correctly seated. Screw in screw coupling (W) and tighten.
III. Flow straightener
Remove and clean flow straightener (13 263), see fold-out page I.
Assemble in reverse order.
Service
Note the Fault/Cause/Remedy table for information on eliminating problems.
If the problem cannot be rectified, disconnect the mains plug to shut off the voltage supply. Note down the serial number of the storage heater on the rear of the device and get in touch with GROHE Customer Service or contact the GROHE Service Hotline under TechnicalSupport-HQ@grohe.com.
The GROHE Red boiling water storage heater cannot be repaired. If servicing is required, the complete storage heater must be replaced. In order to ensure correct operation, maintenance must be performed on all hot-water-bearing parts by GROHE Customer Service every five years.
Following any service/maintenance work, the boiling water storage heater must be re-filled, see section Installation.
Replacement parts
See fold-out page I (* = special accessories).
Care
For directions on the care of this fitting, please refer to the accompanying Care Instructions.
Disposal
Button Display
Display flashing (negative litre specification, e.g. -1 or remaining capacity e.g. 150 flashing)
Press RESET button for 3 seconds (rESEt appears)
The data for time and litre capacity is reset
Button Display
BATT display flashes
(battery is discharged and needs to be replaced)
The date of maintenance must be noted on the maintenance sticker on the storage heater.
This category of devices does not belong in the domestic waste, but must be disposed of separately in accordance with the relevant local national regulations.
Page 7
4
Carbonate hardness Bypass Litre capacity
A
B
40 404 001 40 430 001 40 412 001
9 (°KH) 16 (°fH) 3,38 1,69 3 1.600 l 4.000 l 6.500 l 10 - 24 (°KH) 17 - 43 (°fH) 3,39 - 8,75 1,7 - 4,37 2 600 l 1.500 l 2.300 l
25 - 29 (°KH) 44 - 52 (°fH) 8,76 - 10,35 4,38-5,22 1 350 l 1.000 l 1.500 l
30 (°KH) 53 (°fH) 10,36 5,33 0 250 l 650 l 1.000 l
Fault Cause Remedy
Water too cold • Empty storage heater switched on
(‘On’ indicator lamp flashes)
• Heating phase not yet complete
- Fill the storage heater, see section Installation
Reset the storage heater by pressing the reset button (X) located on the rear of the storage heater using a thin object, see fold-out page IV, Fig. [22]
- Wait max. 15 minutes
Flow rate too low • Fitting flow straightener dirty or defective
• Isolating valve not fully open
• Water supply restricted
- Replace flow straightener, see section
Maintenance
- Fully open shut-off valves, isolating valves
- Check supply lines, open isolating valve
Water not boiling • Storage heater not hot enough yet - Wait approx. 15 minutes after switching on
Storage valve losing water
• Hose connection or internal tank leaking - Switch off the storage heater, disconnect the mains plug and contact GROHE Customer Service
Splashy, irregular spray
• Fitting flow straightener dirty or defective - Replace flow straightener, see section
Maintenance
Fitting running continuously
• Handle not closing - Close the isolating valves, switch off the storage heater, disconnect the mains plug and contact GROHE Customer Service
Page 8
Page 9
Page 10
III
E
D
19mm
F
19mm
OUT
IN
11
D
E
G
H
19mm
19mm
12
19mm
H
I
C
24mm
19mm
13
J
Ø15mm
O1
O
R
15
Q1
Q
P
2sec
16
N
K
M
G
19mm
19mm
L
19mm
14
Page 11
IV
X
22
17
F
18
F2
F3
19
F1
20
S
21
W
R
T
U
30mm
3mm
V
Page 12
www.grohe.com
2013/10/22
D
&
+49 571 3989 333
impressum@grohe.de
A
&
+43 1 68060
info-at@grohe.com
AUS
Argent Sydney
&
+(02) 8394 5800
Argent Melbourne
&
+(03) 9682 1231
B
&
+32 16 230660
info.be@grohe.com
BG
&
+359 2 9719959
grohe-bulgaria@grohe.com
CAU
&
+99 412 497 09 74
info-az@grohe.com
CDN
&
+1 888 6447643
info@grohe.ca
CH
&
+41 448777300
info@grohe.ch
CN
&
+86 21 63758878
CY
&
+357 22 465200
info@grome.com
CZ
&
+420 277 004 190
grohe-cz@grohe.com
DK
&
+45 44 656800
grohe@grohe.dk
E
&
+34 93 3368850
grohe@grohe.es
EST
&
+372 6616354
grohe@grohe.ee
F
&
+33 1 49972900
marketing-fr@grohe.com
FIN
&
+358 10 8201100
teknocalor@teknocalor.fi
GB
&
+44 871 200 3414
info-uk@grohe.com
GR
&
+30 210 2712908
nsapountzis@ath.forthnet.gr
H
&
+36 1 2388045
info-hu@grohe.com
HK
&
+852 2969 7067
info@grohe.hk
I
&
+39 2 959401
info-it@grohe.com
IND
&
+91 124 4933000
customercare.in@grohe.com
IS
&
+354 515 4000
jonst@byko.is
J
&
+81 3 32989730
info@grohe.co.jp
KZ
&
+7 727 311 07 39
info-cac@grohe.com
LT
&
+372 6616354
grohe@grohe.ee
LV
&
+372 6616354
grohe@grohe.ee
MAL
&
+1 800 80 6570
info-singapore@grohe.com
N
&
+47 22 072070
grohe@grohe.no
NL
&
+31 79 3680133
vragen-nl@grohe.com
NZ
&
+09/373 4324
P
&
+351 234 529620
commercial-pt@grohe.com
PL
&
+48 22 5432640
bLuro@gr
ohe.com.pl
RI
&
+62 21 2358 4751
info-singapore@grohe.com
RO
&
+40 21 2125050
info-ro@grohe.com
ROK
&
+82 2 559 0790
info-singapore@grohe.com
RP
&
+63 2 8041617
RUS
&
+7 495 9819510
info@grohe.ru
S
&
+46 771 141314
grohe@grohe.se
SGP
&
+65 6 7385585
info-singapore@grohe.com
SK
&
+420 277 004 190
grohe-cz@grohe.com
T
&
+66 2610 3685
info-singapore@grohe.com
TR
&
+90 216 441 23 70
GroheTurkey@grome.com
UA
&
+38 44 5375273
info-ua@grohe.com
USA
&
+1 800 4447643
us-customerservice@grohe.com
VN
&
+84 8 5413 6840
info-singapore@grohe.com
BiH
AL
HR
KS
ME
MK
SLO
SRB
&
+385 1 2911470
adria-hr@grohe.com
Eastern Mediterranean, Middle East - Africa Area Sales Office:
&
+357 22 465200
info@grome.com
IR
OM
UAE YEM
&
+971 4 3318070
grohedubai@grome.com
Far East Area Sales Office:
&
+65 6311 3600
info@grohe.com.sg
Loading...