Groen XSG-5 Bulletin Manual

Circulate to: Technician
Service Manager
Parts Manager
Service Manual Revised
SERVICE BULLETIN
Bulletin No. 264
DATE: February 13, 2012 Models Affected: Extreme Steam Gas Steamers
Subject: Choke Timer Purpose: To Prevent Delay in Blower Solenoid Activation
Issue: When replacing a choke timer on the Intek gas steamer make sure to order the
choke timer and resistor needed for the model you are servicing. The Blower Solenoid should remain close for 45 seconds for a unit with auto-fill and 16 seconds for a unit that is manually filled.
Cause and Effect: - If the resistor Part # NT1813 that’s used on an auto-fill choke
timer Part # NT1812 is added to a manual choke timer Part # NT1745 the choke will stay engaged for “120 sec” instead of “45 sec”
- If the resistor Part # NT1748 that’s used on a manual fill choke timer is added to an auto-fill choke timer Part # NT1812 the choke will stay engaged 16 sec” instead of 45 sec
If the choke is engaged for an extended period of time, the unit can start to burn poorly and possibly create sooting.
See Figures below for location of choke timer inside steamer compartment and manual versus auto-filled choke timers and descriptions.
Location of Choke timer inside compartment Manual Filled is identified by B-1 Auto- Filled is identified by B-2
Resistor value should be 3.9 OHM Resistor value should be 1.5 OHM