MODEL T25448/T25449
DUST COLLECTOR
REMOTE SWITCH
INSTRUCTIONS
For questions or help with this product contact Tech Support at (570) 546-9663 or techsupport@grizzly.com
Introduction
The Model T25448/T25449 Dust Collector
Remote Switch (Figure 1) allows you to remotely
turn a dust collector ON/OFF from a distance of
up to 75 feet.
Read and understand this entire document before
installation to make sure this switch box fits the
intended application.
To ensure safe operation:
• Only connect the switch box to power supply that meets the listed specifications.
• Do not connect the switch box to a dust
collector with a motor that exceeds the
listed specifications.
Switch
Box
Remote
Controller
Figure 1. Model T25448/T25449 remote switch
components.
Specifications
Model T25448:
Power Supply ....................120V, 15A, 60 Hz
Outlet Type ................................. NEMA 5-15
Max. Dust Collector HP ..................... 1.5 HP
Model T25449:
Power Supply ................... 240V, 20A, 60 Hz
Outlet Type .................................NEMA 6-20
Max. Dust Collector HP ........................ 3 HP
Remote Battery ..........................Type 23AE, 12V
Communication Type ........Radio Frequency (RF)
Max. Communication Distance ................... 75 ft.
• This remote switch is ONLY designed to
be used on dust collectors with standard
ON/OFF toggle or push-button switches—
not with magnetic switches.
• If you are unsure about the type of dust
collector switch you have, contact the dust
collector manufacturer for more information.
• Using this switch box for applications
other than dust collectors may cause the
unit to fail and will void the warranty.
Replacement remote controllers (Model
T25507) can be purchased by contacting
Grizzly at (800) 523-4777. Before the new
remote controller can be used, the switch
box must be programmed to work with it
(refer to Programming Switch Box on Page
2 for detailed instructions).
COPYRIGHT © FEBRUARY, 2013 BY GRIZZLY INDUSTRIAL, INC.
NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
FOR MODELS MANUFACTURED SINCE 8/13 #TS15583 PRINTED IN TAIWAN
Installation
1. Place the switch box in a dry, protected loca-
tion within reach of the power receptacle and
the dust collector power cord.
2. Plug the switch box into the proper power
receptacle (see Figures 2–3).
For T25448
GROUNDED
5-15 RECEPTACLE
Programming Switch Box
You can program one switch box to operate with
several remote controllers and one remote controller to operate several switch boxes. The steps
to accomplish any combination of these options
are the same.
Before beginning, read through the entire procedure to understand the required timing of the
steps.
To program the switch box:
Grounding Prong
5-15 PLUG
Neutral Hot
Figure 2. NEMA 5-15 plug and receptacle for
Model T25448.
For T25449
GROUNDED
6-20 RECEPTACLE
Current Carrying Prongs
6-20 PLUG
Grounding Prong
Figure 3. NEMA 6-20 plug and receptacle for
Model T25449.
1. Make sure the dust collector is NOT connected to the switch box.
2. Make sure the red receiving light on the
switch box is illuminated (see Figure 4).
— If the red receiving light is not illuminated,
the switch box is not receiving power.
Resolve this issue before continuing.
Red Receiving
Light
Programming
Button
Figure 4. Programming controls on rear of
switch box.
3. Perform the following Programming Switch
Box procedure to make sure the remote con-
troller will operate the switch box.
4. Make sure the dust collector ON/OFF switch
is turned OFF, then plug the dust collector
into the switch box.
-2-
3. Press and release the black programming
button once—you will hear three beeps and
the red receiving light will flash three times.
The switch is now in programming mode.
Note: If you do not perform the next step
within approximately five seconds after the
three beeps, you will hear one more beep
and the switch box will leave programming
mode. In this case, you will have to start
Step 3 again.
Model T25448/T25449 (Mfg. Since 8/13)