Grizzly T24103 User guide

Page 1
2 HP 230V 3-PHASE MAGNETIC SWITCH
Electrocution or fire could occur if this switch is not installed or adjust­ed by a qualified electrician!
MODEL T24103
INSTRUCTIONS
230 Volt 3-Phase
Power Source
1L1
3L2 5L3
13
NO
Figure 1. Model T24103 magnetic
switch.
Contactor TECO
CU-16 (230V Coil)
COLOR KEY
BLACK
GREEN
RED
YELLOW
Bk
Gn
Rd
Thermal Overload Relay
TECO RHU-10K1
(7. 2–10A)
TECO
CU­16
2T1
4T2
6T3
97 NO
2T1
9
10 A
8
98 NO
4T2
O
7.2
OFF
95 NC
TRIP IND.
TEST
14
6T3
NO
R
RESET
96 NC
NO 53
Ground
ON
54 NO
M
A
OPE R ATION : When pushed, the green ON button on the outside cover of the magnetic switch energizes a magnetic coil, which pulls the contactor closed. The main current then passes through the contactor and thermal overload relay to the motor. The red OFF button breaks the magnetic field, which opens the contactor and disconnects the current to the motor. A motor overload or an interruption of the power supply will also break the magnetic field and release the contactor and disconnect current to the motor. The motor will not re-start until the overload is reset and/or the ON button is pushed.
COPYRIGHT © OCTOBER, 2011 BY GRIZZLY INDUSTRIAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
#ST14416 PRINTED IN TA IWAN
Page 2
Thermal Relay Overload Amp
REF DESCRIPTION REF DESCRIPTION
Adjustment Dial: Turn this dial to the amperage setting speci­fied by the motor manufacturer. Typically, this setting is 100– 110% of the amperage load listed on the motor data plate. Please note that turning this dial has no effect on increasing motor horsepower. If turned too high, the motor can overheat and be damaged before the relay trips.
Trip Indicator: If this window turns yellow, the thermal relay has tripped.
Manual Contactor Override Lug: When pushed, the contactor
is manually closed for trouble­shooting purposes only.
ON Button: When pushed, power is sent to the magnetic field coil, closing the contactor and sending power to the motor.
Manual/Auto Reset Lever: In the up position, the thermal relay is in manual reset mode. This means you must re-install the outside cover and push the red OFF button, then push the green ON button to reset the thermal relay. In the down position, the thermal relay will automatically reset when it has cooled.
Manual Trip Test Lever: If the thermal relay function is in ques­tion, run the motor and use a wooden toothpick to slide the yellow test lever to the left. If the motor shuts off, the thermal relay has tripped and is functional.
10
11
1
Reset Button: When pushed, the thermal relay is reset, clear­ing the yellow trip indicator win­dow.
OFF Button: When pushed, the current going to the magnetic field coil is cut, which opens the contactor and cuts power to the motor.
Parts Breakdown
3
4
8
6
7
9
5
2
12
1 SWITCH BOX 7 PHLP HD SCR M3-.5 X 10 2 SWITCH BOX COVER ASSEMBLY 8 CAPTURED GROUND SCR M4-.7 X 10 3 CONTACTOR TECO CU-16 230V 9 PHLP HD SCR 10-24 X 1-1/2 4 FIELD SWITCH TECO CNA-1 10 LIQUID-TITE STRAIN RELIEF 5 OL RELAY TECO RHU-10K1 7.2-10A 11 RUBBER SEAL 6 GROUNDING PLATE 12 PLASTC SCREW M10-1.5 X 20 GRAY
-2-
T24103 Magnetic Switch