Grieve Corporation S7820 Installation Manual

65-0095-2
7800 SERIES
S7820 Remote Reset Module
PRODUCT DATA

FEATURES

• Capability to reset 7800 SERIES Relay Module from a remote location.
• Reset button can be installed up to 1000 feet away.
• Can be installed directly onto the front of a 7800 SERIES Relay Module.
NOTE: Many jurisdiction restrict remote resetting of any
appliance and require a location that provides line­of-sight viewing of the appliance. Install the S7820 Remote Reset Module in accordance with local requirements.

APPLICATION

The S7820 Remote Reset Module serves as a link between a remote reset switch and the Relay Module. Similar to the S7800 Keyboard Display Module, it allows the 7800 SERIES Burner Control to be reset from a remote switch, but provides none of the other Keyboard Display Module or Data Controlbus Module™ features.
Contents
Application............................................................................. 1
Features ................................................................................ 1
Specifications ........................................................................ 2
Ordering Information ............................................................. 2
Installation ............................................................................. 2
Checkout ............................................................................... 3
® U.S. Registered Trademark Copyright © 1998 Honeywell Inc. • All Rights Reserved
7800 SERIES S7820 REMOTE RESET MODULE

SPECIFICATIONS

Electrical Connectors (included):
Part no. 203541 ControlBus 5-Wire Electrical Connector,.
Environmental Ratings:
Ambient Temperature:
Operating: -40°F to 140°F (-40°C to 60°C). Storage: -40°F to 150°F (-40°C to 66°C).
Humidity:
Operating: 85% RH continuous, noncondensing.
Vibration: 0.5 G environment.
Dimensions:
See Fig. 1.
Weight:
3 ounces (86 grams) unpacked.
BURNER CONTROL
2-3/4 (69)
29/32
4-27/32
M1986A
Fig. 1. Remote Reset Module dimensions in in. (mm).
(123)
5/32 (4)
(23)

INSTALLATION

When Installing this Product…
1. Read these instructions carefully. Failure to follow them
could damage the product or cause a hazardous condition.
2. Check the ratings given in the instructions and marked
on the product to make sure the product is suitable for the application.
3. The installer must be a trained, experienced, flame
safeguard control technician.
4. Disconnect the power supply before beginning
installation to prevent electrical shock and equipment damage. More than one power supply disconnect may be involved.
5. Wiring must comply with all applicable codes,
ordinances and regulations.
6. After installation is complete, check out the product
operation as provided in these instructions.
Humidity
Install the S7820 Remote Reset Module where the relative humidity never reaches the saturation point. The S7820 Remote Reset Module is designed to operate in a maximum 85% relative humidity (RH) continuous, noncondensing, moisture environment.
Vibration
Do not install the S7820 Remote Reset Module where it can be exposed to vibration in excess of 0.5G continuous maximum vibration.

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer Logistics Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386
3. www.honeywell.com/bbc
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
65-0095—2
2
Loading...