Grid Tied TE-300W-WV, TE-500W–WV User Manual

1
TE- 300/500W –WV Series Inverters
User Manual
2
System Function
z Display function
1AC voltage display
When the 125VAC LED lit up, it means the AC output is 125V. When the 230VAC LED lit up, it means the AC output is 230V.
2Outage display
When the Fault LED lit up, is means there is no electricity or the output is fail, and the inverter restart.
3Power shows
Power output LED: The 5 red LEDS take turns lighting, the quicker the lights move, the more power output.
4AC frequency display
When the 50Hz LED lit up, it means the input frequency is 50Hz. When the 60Hz LED lit up, it means the input frequency is 60Hz.
5DC over-voltage display
When the Fault LED and the “HIGH” LED lit up, it means the DC input is over 62VDC
6DC under- voltage display
When the Fault LED and the “LOW” LED lit up, it means the DC input is low 22VDC.
7Power adjust display
1) When “ST” LED flashing, it means power is in adjusting condition. a. When the “ST” LED and “HIGH” LED lit up, it means the power is increase. b. When the “ST” LED and “LOW” LED lit up, it means the power is decrease.
2) When “ST” LED long on time, is means the power is locked, and the inverter works.
z 6-grade power search
In overcast weather,the solar battery’s output current is extremely tiny, then inverter will automatic open 6-grade power search function.
2The program can automatically open power adjustment for 6 times. 3The current direction can adjust from the maximum to the minimum. 4In automatic adjustment process, we will see the LOW light flashing.And the power will keep as a
starting point, from 0 to the maximum output power, and it will restart at most for 6 times, then locked in the maximum power, the ST lamp long bright.
5、It need 10 minutes for 6-grade power search.
z Wide voltage input(22-60VDC
Achieve wide voltage input. 1DC voltage input22-60VDC 2Second level power variable voltage conversion
z High-frequency two-way and one-way grid function
1High frequency direct modulation, AC half wave synthesis 2Two-way grid means: Load consume directly. And can reverse AC current transmission. 3One-way grid means: Load consume directly. And banned reverse AC current transmission.
z Kinds of frequency output function.
It can apply to 50Hz and 60Hz frequency of AC. Frequency range: 45Hz ~53Hz/55Hz~ 63Hz
z directly connected to the solar panels (do not need to connect the battery)
Using precise Dynamic differential pressure type MPPT function, APL functions, the inverter automatically adjust the solar panels of maximum output powersimply connect the solar panel to the grid inverters. Do not need to connect the battery. 1Differential pressure type MPPT: 0.1 V accuracy
3
2Power lock: 10W (AC output)
z AC 0 angle with high precision auto-detection
AC phase angle of 0 through isolation amplifier then input to the MCU for high-precision detection and analysis. The phase shift rate is less than 1%, thus achieve high-precision with phase modulation AC output together. 1AC phase shift: < 1% 2Over-zero protection: 0.2 VAC 3AC switching: 50Hz / 60Hz
Synchronous High-frequency Modulation
In the process of the grid, usually adapt the same phase angle in parallel. (ie, When the two-phase alternating current total is equal to 0.Use switch to combination the two AC fusion) and the product is rectified AC half-frequency AC to 100Hz first, then the machine use the high frequency current in the circuit and semi-100Hz frequency alternating current generated combination, to achieve high-frequency modulation. 1Modulation synthesis: half wave and full-bridge modulation synthesis (100Hz / 120Hz) 2Synthetic way: MOSFET full-bridge 3High frequency: 50KHz
Pure Sine Wave Output
Use SPWM directly to make pure sine wave output.
1Output waveform: Adopt complementary PWM to push-pull pure sine wave.
2Generate means: enhancement-mode SPWM
z Automatic Sensing Function Solar Luminosity
Use the latest luminosity perception operation technology. The different illuminate angle and intensity of the solar panel will produce different current output. Use advanced CPU to operate the different illuminance and the data can be directly displayed on the LCD. Then you can visually see the sense of the strength of the sun unit. Used more convenient. 1Luminosity sampling point power sampling point 2High precision AD sampling: integral AD sampling method
Power Automatically Locked (APL)
In different current fluctuations, we should use the MPPT function. When the MPPT function adjusted to the maximum power point, the product automatically powers locked in maximum power point, then made the output power more stable. 1Power lock: The biggest sampling point of MPPT.
Automatically Adapt To Different Load Power Factor
Adapt to any of the power load.
z Constant Current, Constant Power
This product is constant current, constant output power, without any overload, over-current phenomenon.
z Automatically Shut Down When The Power Output Of a Fault
When the city power system is in failure, the inverter will automatically turn off the output.
Current Limit Protection
Current limit
z Stack Multiple Machines z Multiple small power inverters in parallel can achieve large output power. z High-Frequency High Conversion Rate
Adapt high frequency converter, the output more efficient.
Maximum Power Point Tracking (MPPT)
Because the current intensity and the voltage changes at any time, if there is no power point tracking, there
will be a lot of problems. In the past time, usually adopt a solar controller, but this product uses high-precision
Loading...