LOW PRESSURE
TRANSMITTERS
LP3 Series
LP3 c/w LCD
LP3 c/w integrated
static probe
Precision low pressure
control/sensing
FEATURES:
• Jumper selectable 2 wire current and 3 wire
voltage outputs
• 24 Vac/dc power supply
• Six variable jumper selectable pressure ranges, W.C. & Pa.
• Available options include LCD display and
integrated static probe
Peace of mind
through reliable
pressure monitoring
GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM

APPLICATIONS:
• HVAC/VAV
• Process Control
• Air Flow Monitoring
• Drop Across Air Filters
• Hydraulic Pressures
• Pneumatic Pressures
SPECIFICATION:
Accuracy................................................. ±1% F.S.O.
Measurement Type............................. Dierential (two port)
Response Time .....................................250 ms
Stability................................................... < ±1% F.S.O. per year
Thermal Eects.....................................< ±3% over compensated range
Compensated Range .........................0 - 50˚ C (32 - 122˚F)
Proof Pressure....................................... 40” W.C. (100“ for 12” and 20“ models)
Burst Pressure....................................... 60” W.C. (200” for 12” and 20” models)
Operating Conditions........................ 0 - 70˚C (32 - 158˚F), 10 - 90 %RH, non-condensing
Media Compatibility...........................Non-corrosive, non-ionic uids such as clean dry air or inert gases
Power Supply........................................20 - 28 Vac/dc (non-isolated half-wave rectied)
Supply Current .....................................< 4 mA
Input Voltage Eect............................ Negligible over specied operating range
Protection Circuitry.............................Reverse voltage protected and out limited
Output Signal........................................4-20 mA (2-wire), 0-5 or 0-10 Vdc (3-wire), switch selectable
Output Drive Capabilities................. Current: 400 ohms max @ 24 vdc
Voltage: 10K ohms min
Zero Adjustments................................Pushbutton auto-zero
Wiring Connections............................ Screw terminal block (14 to 22 AWG)
Pressure Connection.......................... Barbed ports for 5 mm (0.170“) ID exible tubing
Conduit Connection........................... Access hole for ½” NPT conduit or cable gland
Optional Display.................................. 3½ digit LCD, 0.4“ digit height
Enclosures.............................................. ABS, UL94-5VB, IP61 (NEMA 2)
127mm x 84mm x 53mm (5.00” W x 3.3“ H x 2.1” D )
Weight..................................................... 159 grams (5.6 oz)
ACCESSORIES:
FPP & SPP Series
Pitot Tube
The FPP and SPP series are used to sense
velocity pressure or static pressure respectively.
Constructed of 304 stainless steel probes with
an ABS mounting bracket, they available in 150
mm (6”) or 300 mm (12”) lengths. Kits are
available for dierential and static that are
complete with pneumatic tubing.
DPFS Series
Dierential Pressure Probe
The DPFS series Averaging Flow Sensor is ideal
for sensing dierential pressure in the inlet
section of variable air volume terminal units
and fan terminal units. Units can also be used
to sense dierential pressure at other locations
in the main or branch duct systems. They are
made of ABS/polycarbonate (UL94-5V) and
available in lengths from 100 mm (4”) to 560
mm (22”)
MP Series
Dierential Pressure Probes
The MP series Air Velocity Pitot Tubes are used
in conjunction with a DP transmitter to
calculate airow in larger ducts or in areas of
turbulent airow. The units come in pairs in
either ABS or 316 S/S and are available in
various lengths from 610mm (24”) to 2000 mm
(80”). Gasketed mounting collars for both
probes are included.