GREISINGER GMH 3221, GMH 3231, GMH 3211, GMH 3251 Operating Manual

H76.0.13.6C-03
GHM GROUP - Greisinger
GHM Messtechnik GmbH | Hans-Sachs-Str. 26 | 93128 Regenstauf | GERMANY Tel.: +49 9402 9383-0 | info@greisinger.de | www.greisinger.de
Operating manual
Quick-Response
Double / Difference Thermometer
as of version 4.0
GMH 3221
Please carefully read these instructions before use!
WEEE-Reg.-Nr. DE 93889386
Please consider the safety instructions!
Please keep for future reference!
H76.0.13.6C-03 Operating Manual GMH 3221 page 2 of 12
_____________________________________________________ _____________________________________________________________________________
Index
1 GENERAL NOTE ............................................................................................................... 2
2 SAFETY ................................................................................................................................ 3
2.1 INTENDED USE .................................................................................................................. 3
2.2 SAFETY SIGNS AND SYMBOLS ............................................................................................ 3
2.3 SAFETY GUIDELINES .......................................................................................................... 4
3 PRODUCT SPECIFICATION ........................................................................................... 5
3.1 SCOPE OF DELIVERY .......................................................................................................... 5
3.2 OPERATION AND MAINTENANCE ADVICE ........................................................................... 5
4 HANDLING ......................................................................................................................... 5
4.1 DISPLAY ............................................................................................................................ 5
4.2 BASIC OPERATION ............................................................................................................. 6
4.3 CONNECTIONS ................................................................................................................... 6
4.4 POP-UP CLIP ...................................................................................................................... 7
5 START OPERATION ......................................................................................................... 7
6 CONFIGURATION............................................................................................................. 8
7 REMARKS TO SPECIAL FEATURES ........................................................................... 8
7.1 TARE FUNCTION ................................................................................................................ 8
7.2 POWER OFF TIME ............................................................................................................... 8
8 ADJUSTMENT .................................................................................................................... 9
8.1 ZERO DISPLACEMENT SENSOR 1 ('OFS.1') OR SENSOR 2 ('OFS.2') ................................... 9
8.2 SCALE CORRECTION SENSOR 1 ('SCL.1') OR SENSOR 2 ('SCL.2') ...................................... 9
8.3 CALIBRATION SERVICES .................................................................................................... 9
9 FAULT AND SYSTEM MESSAGES .............................................................................. 10
10 RESHIPMENT AND DISPOSAL ................................................................................. 11
10.1 RESHIPMENT ................................................................................................................. 11
10.2 DISPOSAL ..................................................................................................................... 11
10.3 DECOMMISSIONING ...................................................................................................... 11
11 SPECIFICATION ........................................................................................................... 12
1 General Note
Read this document carefully and get used to the operation of the device before you use it. Keep this document within easy reach near the device for consulting in case of doubt.
H76.0.13.6C-03 Operating Manual GMH 3221 page 3 of 12
_____________________________________________________ _____________________________________________________________________________
2 Safety
2.1 Intended Use
This device is designed for temperature measurement. You can plug in up to 2 thermocouple sensors with Miniature-DIN-plug. If you use two sensors, you can measure two different temperatures as well as the difference between them. The device features a lot of useful features as for example min-/max-alarm, hold, correction factor for surface measurement, interface etc.
Personnel which starts up, operates and maintains the device has to have sufficient knowledge of the measuring procedure and the meaning of the resulting measured values, this manual delivers a valuable help for this. The instructions of the manual have to be understood, regarded and followed.
To be sure that there´s no risk arising due to misinterpretation of measured values, the operator must have further knowledge in case of doubt - the user is liable for any harm/damage resulting from misinterpretation due to insufficient knowledge.
The manufacturer will assume no liability or warranty in case of usage for other purpose than the intended one, ignoring this manual, operating by unqualified staff as well as unauthorized modifications to the device.
The safety requirements (see below) have to be observed. The device must be used only according to its intended purpose and under suitable
conditions. Use the device carefully and according to its technical data
(do not throw it, strike it, …). Protect the device from dirt.
2.2 Safety signs and symbols
Warnings are labelled in this document with the followings signs:
Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance.
Attention! This symbol warns of possible dangers or dangerous situations which can provoke damage to the device or environment at non-observance.
Note! This symbol point out processes which can indirectly influence operation, possibly cause incorrect measurement or provoke unforeseen reactions at non-observance.
H76.0.13.6C-03 Operating Manual GMH 3221 page 4 of 12
_____________________________________________________ _____________________________________________________________________________
2.3 Safety guidelines
This device has been designed and tested in accordance with the safety regulations for electronic devices. However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given in this manual will be adhered to when using the device.
1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under chapter 11 Specification.
2. If there is a risk whatsoever involved in running it, the device has to be
switched off immediately and to be marked accordingly to avoid re­starting. Operator safety may be a risk if:
- there is visible damage to the device
- the device is not working as specified
- the device has been stored under unsuitable conditions for a longer time. In case of doubt, please return device to manufacturer for repair or maintenance.
3. Do not use these products as safety or emergency stop devices or in
any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in death or serious injury and material damage.
4. This device must not be used at potentially explosive areas! The usage
of this device at potentially explosive areas increases danger of deflagration, explosion or fire due to sparking.
5. This device is not constructed for use in medical applications.
6. Temperature sensor:
There is a risk of stitch injury by using insertion probs. When measuring high temperatures there is a risk of burn, also due to residual heat of the sensor tube.
7. Consider when measuring in food:
The device housing is not construed for the permanent contact with food. Keep in mind to use temperature-probes witch are suitable for the use in food only.