Greenwood Unity CV3, Unity CV3 SELV Installation And Operating Instructions Manual

Unity CV3
Decentralised Mechanical Extract Ventilation (dMEV)
Installation and Operating Instructions
The Unity CV3 is a continuously running (dMEV) extract fan, designed to offer a simplistic approach to meet Building Regulations and provide an energy efficient domestic ventilation solution to improve indoor air quality in dwellings.
Please read instructions before commencing the installation.
Please make these instructions available for the user.
Overview
The Unity CV3 is a continuously running (dMEV) fan that revolves around ‘one product’, which has been designed to be flexible in application and t
o meet the performance requirements of all ‘wet’ rooms within a dwelling.
This product features on the Product Characteristics Database (PCDB), part of the process will require the Installation Checklist for dMEV products to be completed and submitted to building control, available at w
ww.ncm-pcdb.org.uk, along with all other relevant paperwork.
Your Unity CV3 may have the following features activated:
* Intelligent sensing via the Greenwood TimerSMART
automatic integral delay / over-run timer and humidity functions) which monitor the homeowners’ environment.
* Delay-on-timer, set between 1-60 minute period.
* A 'do not disturb' night mode where your fan will not boost for a period of time upon activation of the
light switch.
Note: These functions only affect the higher extract boost mode, your fan will continue to ventilate at the lower trickle mode.
Key: Installer Information pages 2 - 9 User Information pages 10 - 11
TM
and Greenwood HumidiSMARTTMtechnology (fully
Important:
Please read these instructions before commencing the installation
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision. Ensure
the fan is switched off from the mains supply before cleaning commences.
Where an open-flued oil or gas-fuelled appliance is installed, precautions must be taken to
avoid a back-flow of gases into the room.
When installing wall mounted fans, ensure that there are no buried cables or pipes in the way.
It is recommended that this fan is mounted >1.8m above floor level and within 400mm of the finished ceiling.
The fan should not be sited where it would be subject to a direct heat source in excess of 40°C,
e.g. at least 600mm distance from cooker hob.
Observe appropriate safety precautions if working on steps or ladders.
Wear eye protection when breaking out wall or ceiling materials, etc.
To disassemble the unit, disconnect from mains supply and use a screwdriver to segregate the
electronic components and motor from the plastic housing. Dispose items in accordance with WEEE.
WEEE Statement
This product may not be treated as household waste. Instead it should be handed to an appropriate collection point for the recycling of electrical and electronic equipment. For more detailed information about the recycling of this product, please contact your local council office or your household waste disposal service.
2
Installation Preparation
CV3 Cover Ø 197mm
126mm
Ø 99mm
4
8mm
6
8mm
Ø 178mm
5
8mm
Installation Preparation
Electrical installation must only be carried out by
qualified Electrician and in accordance with the
a current editions of Building Regulations and BS7671: IEE Wiring Regulations.
The Unity CV3 fan is supplied with a 100mm nominal spigot for connection of ducts for installation - 100mm diameter rigid duct should be used to provide the best performance levels required for compliance with Building Regulations.
Technical Services can be contacted on
Main body
+44 (0) 1276 408402 should you have any questions in respect of this.
Outer cover
Preparing your fan for installation
Upon removal from packaging, rotate ‘outer cover’ anticlockwise until retaining clips are released and place the cover to one side.
Loosen retaining screw in main body cover and rotate anticlockwise to remove.
The unit can be installed on a wall, window (with separate adaptor kit) or ceiling mounted and ducted.
Wall Preparation
Ceiling Preparation
Ø = 105mm
Window Preparation
Retaining screw
Ø = between 102mm - 117mm (to suit ducting dimensions)
Allow a clearance of 50mm from wall/ceiling edges around the fan
Cut the duct to depth of the plasterboard or tiled wall with slight fall to exterior (Make provisions for cable).
Fill in any gaps with mortar or foam and make good internal and external walls. Make sure that ducting retains its original shape.
Cut an opening through the
.
ceiling for the fan and electrical cable.
Cut circular hole within window pane.
• minimum Ø = 118mm
• maximum Ø = 130mm
X
Ø
See instructions
X = 65 Ø = 105mm
with window kit for installation details.
3
Installation
Installation
STEP 1
Connect ducting to the spigot on the back of the Unity CV3
Note: If using flexible ducting, ensure this is pulled taut (to a min. 90% stretch capacity) between fan and termination
STEP 2
Loosen retaining screw until you can rotate main body cover of the fan anticlockwise to ‘unlock position’ and remove cover
Lock position Unlock position
Retaining screw
4