Greenwood SK200A, SK200B2, SK200MA, SK200T Installation Instructions Manual

SK200A for Continuous Applications SK200B2, MA & T Centrifugal Fans for Kitchens & Utility Rooms
Greenwood Air Management Ltd
Greenwood House
Brookside Avenue
Rustington, West Sussex BN16 3LF
Email: info@greenwood.co.uk
Internet: www.greenwood.co.uk
Environmental
Slotvent
Installation Instructions
SK200 install AW 3.6.10 4/6/10 01:58 Page 1
32
Read all instructions before commencing installations
WARNING NOTES:
The appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely. Young children should be supervised to ensure that they do not play with the appliance.
Siting Notes: Where an open-flued oil or gas- fuelled appliance is installed in the kitchen, extract ventilation can cause the spillage of flue gases. Care must be taken to ensure ventilation is reduced appropriately, as set out in the Building Regulations. Kitchens with solid-fuel appliances should not have extract fans fitted.
The fan should not be sited where it is subject to a direct source of heat in excess of 40˚C.
Operation
The S200 range of fans are available with various control options suited to kitchen, bathroom and toilet applications
SK200A – Dual speed operation, continuous at low speed, boost via remote switch, light switch or pull cord.
SK200B2 – Dual speed operation by pull cord, remote switch or light switch.
SK200MA – Dual speed operation with humidistat to low speed with adjustable overrun timer to further reduce humidity. Manual operation by pull cord, remote switch or light switch to full speed, without overrun timer.
SK200T – Single speed operation by pull cord, remote switch or light switch with overrun timer for adjustable time period.
To clean or service fan and filter
WARNING: Fan must be isolated from mains electricity supply before carrying out any maintenance.
Wall Mounting rear exit
1
2
The fan and grille may now be cleaned using a brush or damp cloth. Do not immerse in water
.
The filter may be cleaned in warm soapy water –
ensure filter is dry before re-fitting to fan.
NOTE: CLEANING OF THE SK200MA MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Ducting
External Grille
The unit can be mounted to the
wall either by rear entry or side entry depended on mounting position and access to the outside.
The unit can be mounted in any
orientation to suit the room space.
When installing wall mounted fans,
ensure that there are no buried cables or pipes in the way. It is recommended that this fan is mounted 2.3m above floor level.
SK200 install AW 3.6.10 4/6/10 01:58 Page 2
Select supply cable entry
See page 10 for wiring instructions
54
Wall Mounted with rear exit installation
Wall Mounted with side exit installation
9
11
2
10
1
3
8
A
A
Inside
Outside
>1˚
2
4
5
1
Ø
= 125mm
Ø
6
7
3
4
DO NOT DISTORT BACKPLATE WHEN FITTING
C
ut out for surface
m
ounted cabling
A
B
Remove 2 screws. Release cover with flat blade
screwdriver A then apply thumb pressure to release
catch in position B and gently pull free.
Fit 2 cover screws and tighten, ensure corners
clip into place
T
ighten 3 screws to secure
Slide the top of the cover mounting clip into alignment. Push cover in centre to engage centre clip.
Replace grille
A
B
A
B
12
SK200 install AW 3.6.10 4/6/10 01:58 Page 4