Greenwood EL100 SELV Installation Instructions Manual

Installation Instructions
EL100 SELV (Safety Extra Low Voltage) Axial Fans for Bathroom & Toilets
Greenwood Air Management Ltd
Brookside Industrial Estate
Rustington, West Sussex BN16 3LH
Tel: 01903 771021. Fax: 01903 782398
Internet: www.greenwood.co.uk
Environmental
Slot vent
Elite SELV Inst 26/8/04 3:36 pm Page 1
32
NOTES:
Where an open-flued oil or gas- fuelled
appliance is installed in the kitchen, extract ventilation can cause the spillage of flue gases. Care must be taken to ensure ventilation is reduced as appropriate, as set out in the building regulations. The guide to the regulations suggests that the reduced provision should be an extract rate of 20 l/s (72 m
3
/h) maximum. Kitchens with solid-fuel appliances should not have extract fans fitted.
The fans should not be sited where
it would be subject to a direct source of heat in excess of 40ºC.
For window mounting do not install fans in
opening windows. Use the correct thickness of glass for the size of window (at least 4 mm thick) if in doubt, contact a glazier.
A clearance of 75 mm to be allowed on both
sides of fan for the removal of the internal grille.
Operation
The Airvac Elite range of fans are single speed SELV 12V axial flow extract fans to exceed Building Regulation requirements for bathroom and toilet ventilation. The remotely mounted controller contains switch line control.
Types of controls and operation
as follows:
TYPE ‘T’
Operation by pull cord, light switch or remote switch.
Integral pull cord will activate the fan for pre-set overrun timer operation. If wired into room light or remote switch the fan will operate whilst the switch is on. Switching off will activate the overrun timer.
TYPE ‘TR’
Operation by light switch or remote switch.
When wired into room light or remote switch the fan will operate whilst the switch is on. Switching off will activate the overrun timer.
TYPE ‘HTR’
Automatic operation by light switch or remote switch.
The fans integral humidity sensor will operate the fan whilst the RH exceeds the pre-set activation point, When the RH is reduced back to the activation point the linked overrun timer continues to operate the fan for the pre-set time period to ensure the RH level is further reduced within the room to prevent ‘hunting’.
When wired into room light or remote switch the fan will operate whilst the switch is on. Switching off will activate the overrun timer.
See Sensor / Timer Adjustments section for further details.
The Airvac Elite range of fans are fitted with electrical operated anti-backdraught shutters which have a time delay to open or close.
Read all instructions before commencing installations
Elite SELV Inst 26/8/04 3:36 pm Page 2
54
7
1
3
5
8
4
6
Window Mounting
EL100 SELV Ø = 118 mm ± 1 mm
Make sure rubber cable grommet is fitted onto cable before threading cable through fan back plate.
Ø
EL100 SELV
EW100
For window mounting do
not install fans in opening windows. Use the correct thickness of glass for the size of window (at least 4 mm thick) if in doubt, contact a glazier.
The components supplied are
suitable for the installation of fans in windows from 4 mm single glaze to 28 mm thick double­glazing.
To aid assembly, smear the spigot of the fan or lip of seal with silicone lubricant or silicone polish.
2
SEE PAGE 8 FOR WIRING INSTRUCTIONS
25 mm long screws – Single glazing 38 mm long screws – 20 mm & 24 mm double glazing 50 mm long screws – 28 mm double glazing